• Title/Summary/Keyword: Pulse on time

Search Result 1,706, Processing Time 0.039 seconds

A study on the pulse forming of pulsed $CO_2$ laser using active multi-pulse superposition (능동적 다중 펄스 중첩법(AMPS)을 적용한 펄스형 $CO_2$ 레이저의 펄스 성형에 대한 연구)

  • Chung, Hyun-Ju;Park, Sung-Joon;Jung, Yong-Ho;Song, Gun-Ju;Kim, Hee-Je;Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1631-1633
    • /
    • 2001
  • In manufacturing processes, various and suitable pulse shapes are required for the purpose of material processing and the pulseshape is regarded as a dominant factor due to the specific property of processing materials. Therefore, in this study, a variable pulse width, high duty cycle Pulse Forming Network(PFN) is constructed by time sequently. The power supply for this experiment consists of three switching circuits. The PFN elements operate at low voltage and drive the primary of HV leakage transformer. The secondary of the transformer has a full-wave rectifier, which passes the pulse energy to the load in a continuous sequence of properly phased and nested increments. We investigated laser pulse width as various delay time among three switching circuit. As a result, we tan obtain various laser pulse width from about 4ms to 10ms. The maximum laser pulse width obtained at this experiment was about 10ms at delay time of 4ms among each switching circuit.

  • PDF

Investigation of EDM Characteristics of Nickel-based Heat Resistant Alloy

  • Kang, Sin-Ho;Kim, Dae-Eon
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.10
    • /
    • pp.1475-1484
    • /
    • 2003
  • The EDM processing characteristics of one of the nickel-based heat resistant alloys, Hastelloy- X, were investigated under the various EDM conditions and analyzed in terms of surface integrity. This alloy is commonly used as a material for the hot gas path component of gas turbines and it is difficult to machine by conventional machining methods. The primary EDM parameter which was varied in this study were the pulse-on time. Since the pulse-on time is one of the main factors that determines the intensity of the electrical discharge energy, it was expected that the machining ratio and the surface integrity of the specimens would be proportionally dependent on the pulse-on duration. However, experimental results showed that MRR (material removal rate) and EWR (electrode wear rate) behaved nonlinearly with respect to the pulse duration, whereas the morphological and metallurgical features showed rather a constant trend of change by the pulse duration. In addition the heat treating process affected the recast layer and HAZ to be recrystallized but softening occurred in recast layer only. A metallurgical evaluation of the microstructure for the altered material zone was also conducted.

A study on the output characteristics of long-pulse Nd:YAG laser of sequential discharge of method (Multi-discharge 방식의 long-pulse 고체 레이저의 출력 특성에 대한 연구)

  • Song, K.Y.;Kwak, S.Y.;Hong, J.H.;Noh, K.K.;Kim, H.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.168-171
    • /
    • 2002
  • In this study. a solid-state laser system adopting a sequential discharge method in which three flashlamps are turned on sequently was designed and fabricated to examine the pulse width and the pulse shape of the laser beams depending upon the changes in the lamp turn-on time. That is, this study shows a technology that makes it possible to make various pulse shapes by turning on three flashlamps sequently with the aid of a PIC one-chip microprocessor. With this technique, the lamp turn-on delay time can be varied more diversely from a to lamp and the real-time control is possible with an external keyboard, enabling various pulse shapes. In addition, longer pulses can be more widely used for industrial processing and lots of medical purposes.

  • PDF

Time-dependent Characteristics of Pulse Modulated rf Plasma (펄스모듈레이션 된 고주파 플라즈마의 시변특성)

  • Lee Sun-Hong;Park Chung-Hoo;Lee Ho-Jun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.11
    • /
    • pp.566-571
    • /
    • 2004
  • Pulse modulation technique provide additional controling method for electron temperature and density in rf and microwave processing plasma. Transient characteristics of electron density and temperature have been measured in pulse modulated rf inductively coupled argon plasma using simple probe circuit. Electron temperature relaxation is clearly identified in the after glow stage. Controllability of average electron temperature and density depends on the modulation frequency and duty ratio. Numerical calculation of time-dependent electron density and temperature have been performed based on the global model. It has been shown that simple langmuir probe measurement method used for continuous plasma is also applicable to time-dependent measurement of pulse modulated plasma.

Study on the Waveform Analysis of Radial Artery Pulse Diagnosis Using Pulse Meter and Analyzer - the Waveform Analysis of Left KWAN Pulse Dignosis - (맥상기를 통한 요골동맥 맥진법의 맥파분석 - 좌관부위 맥파요인을 중심으로 -)

  • Kim, Gyeong-Cheal;Lee, Jeong-Won;Ryu, Kyeong-Ho;Park, Dong-Il;Shin, Woo-Jin;Kang, Hee-Jung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.186-191
    • /
    • 2009
  • In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundaments of contemporary pulse diagnosis research. As we will to do experimental research on the difference of pulse waveform on the radial artery with applied variations of pressure(5 stage-pressure) and measuring position(CHON, KWAN, CHEOG). First of all, in this research, we did the experiment of the study on the waveform analysis of radial artery(left KWAN) pulse dignosis by using 3 dimension pulse meter and analyzer (3D MAC). As a result. we extracted the seven measurement fluents : energy(E), size of cycle(h1), size of reflection cycle(h2), time of reflection cycle(t2), time of contraction (t4), width of cycle(w), area of waveform(A) by the statistically reasonable differences. We expect that the seven measurement fluents contribute to divide the situation through the results of waveform analysis of radial artery.

A Study on the Pulse Generator using PFN (PFN을 이용한 펄스발생기의 연구)

  • Lee, B.H.;Joung, K.M.;Park, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1773-1775
    • /
    • 1998
  • This paper deals with the pulse generator using PFN(Pulse Forming Network), and its operation characteristics and application. Two kinds of pulse generator were composed of the best appropriate condition circuit. The output current of the one pulse generator has the rise time of 28 ns and the pulse duration of $7{\mu}s$. The other pulse generator has high current of about 2kA. By use of the former generator with rapid rise time, the impulse impedance characteristic of ground electrodes was investigated with measuring the ground potential rise when the pulse current was injected into the ground electrode.

  • PDF

Implementation of Intelligence Pulse Wave Detection System (지능형 맥진기 구현)

  • Hong, Y.S.;Yu, J.S.;Chang, S.J.;Sun, S.H.;Lee, W.B.;Nam, D.H.;Yu, M.S.;Choi, M.B.;Lee, S.S.
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.245-254
    • /
    • 2013
  • In oriental medicine, it is possible to classify and treat many diseases using the pulse wave detection system. Other problems may arise. As it is a very subjective way to analyze the pulse wave. One problem of the conventional pulse wave detection system is that the arterial pulse sensor is not located correctly at the radial artery. Threrefore measurement results can differ depending on the measurement position and the measurement procedure. This is mostly due to it's sensitivity to high reproducibility. In order to solve this problem this paper proposes an algorithm to analyze the weak pulse wave symptom and strong pulse wave symptom. It uses the portable pulse wave detection system which includes a Hall Sensor. As a final result, it analyzed the weak pulse wave symptom and strong pulse wave symptom by the SPSS statistics technique. It proves that N time (notch point time) and S Amp (rise waveform size) mean values are significantly different in 95% confidence interval.

Development of 60KV Pulsed Power Supply using IGBT Stacks (IGBT 직렬구동에 의한 60KV 펄스 전원장치 개발)

  • Ryoo, Hong-Je;Kim, Jong-Soo;Rim, Geun-Hie;Goussev, G.I.;Sytykh, D.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.88-99
    • /
    • 2007
  • In this paper, a novel new pulse power generator based on IGBT stacks is proposed for pulse power application. Because it can generate up to 60kV pulse output voltage without any step- up transformer or pulse forming network, it has advantages of fast rising time, easiness of pulse width variation and rectangular pulse shape. Proposed scheme consists of series connected 9 power stages to generate maximum 60kV output pulse and one series resonant power inverter to charge DC capacitor voltage. Each power stages are configured as 8 series connected power cells and each power cell generates up to 850VDC pulse. Finally pulse output voltage is applied using total 72 series connected IGBTs. To reduce component for gate power supply, a simple and robust gate drive circuit is proposed. For gating signal synchronization, full bridge invertor and pulse transformer generates on-off signals of IGBT gating with gate power simultaneously and it has very good characteristics of short circuit protection.

Influence of first sustain pulse width on equilibrium sustain current in AC-PDP with ramp reset pulse

  • 김성수
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.200-200
    • /
    • 2000
  • AC-PDP의 구동은 인가되는 Pulse의 파형에 의하여 결정된다. 이번 실험은 AC-PDP의 Subfield 파형중 Sustain 부분 첫 번째 Pulse의 폭(Width)에 변화를 주어 다음 Suatain Pulse 기간동안의 전기 광학적 특성을 구속 카메라와 전류의 변화를 통하여 측정하였으며 Sustain Pulse의 Rising Time을 변화 시켜 방전특성을 측정하였다. 이를 통하여 적합한 Sustain 구간의 초기조건을 예측하였으며, 적합한 Sustain Pulse를 찾아가는 실험 방법을 찾고자 하였다.

  • PDF

The effect of Er:YAG laser irradiation on the surface microstructure and roughness of hydroxyapatite-coated implant

  • Kim, Seong-Won;Kwon, Young-Hyuk;Chung, Jong-Hyuk;Shin, Seung-Il;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.6
    • /
    • pp.276-282
    • /
    • 2010
  • Purpose: The present study was performed to evaluate the effect of erbium:yttrium-aluminium-garnet (Er:YAG) laser irradiation on the change of hydroxyapatite (HA)-coated implant surface microstructure according to the laser energy and the application time. Methods: The implant surface was irradiated by Er:YAG laser under combination condition using the laser energy of 100 mJ/pulse, 140 mJ/pulse and 180 mJ/pulse and application time of 1 minute, 1.5 minutes and 2 minutes. The specimens were examined by surface roughness evaluation and scanning electron microscopic observation. Results: In scanning electron microscope, HA-coated implant surface was not altered by Er:YAG laser irradiation under experimental condition on 100 mJ/pulse, 1 minute. Local areas with surface melting and cracks were founded on 100 mJ/pulse, 1.5 minutes and 2 minutes. One hundred forty mJ/pulse and 180 mJ/pulse group had surface melting and peeling area of HA particles, which condition was more severe depending on the increase of application time. Under all experimental condition, the difference of surface roughness value on implant surface was not statistically significant. Conclusions: Er:YAG laser on HA-coated implant surface is recommended to be irradiated below 100 mJ/pulse, 1 minute for detoxification of implant surface without surface alteration.