• Title/Summary/Keyword: Pulse on time

Search Result 1,708, Processing Time 0.029 seconds

The Classification and Frequency Analysis in Radial Pulse (맥파의 인식상의 분류와 주파수 해석)

  • Kil, S.K.;Han, S.H.;Kwon, O.S.;Park, S.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.263-264
    • /
    • 1998
  • In this paper, we present the result of feature points recognition and classification of radial pulse by the shape of pulse wave. And we analyze radial pulse in frequency domain. The recognition algorithm use the method which runs in parallel with both the data of ECG and differential pulse simultaneously to recognize the feature points. Also fie specified 3-time elements of pulse wave as main parameters for diagnosis and measured them by execution of algorithm, then we classify the shape of radial pulse by existence and position of feature points. lastly we execute frequency analysis on the feature points and get the power spectrum of radial pulse.

  • PDF

The Impulse Output Characteristics using Cascading Method of Compact Transformer (소형트랜스의 Cascading 방식을 적용한 임펄스 출력특성)

  • Joung, Jong-Han;Kim, Whi-Young;Hong, Jung-Hwan;Park, Koo-Ryul;Kim, Hee-Je;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1865-1867
    • /
    • 2000
  • The pulse power system has been widely used to many applications. such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, ozon generator. etc. A pulse energy efficiency for load depend on the rising time, peak value, pulse duration, impedance matching. etc. The pulse generator generally required for short pulse duration, high peak value was forced to consider its size and economy. In this study, developing a compact pulse generator that applied for Cascading method to be made of two pulse transformer, we compared cascading voltage with no cascading one by applying the pulse energy to load.

  • PDF

Estimating blood pressure using the pulse transit time of the two measuring from pressure pulse and PPG

  • Kim, Gi-Ryon;Ye, Soo-Young;Kim, Jae-Hyung;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2008
  • Blood pressure (BP), one of the most important vital signs, is used to identify an emergency state and reflects the blood flow characteristics of the cardiovascular system. The conventional noninvasive method of measuring BP is inconvenient because patients must wear a cuff on their arm and the measurement process takes time. This paper proposes an algorithm for estimating the BP using the pulse transit time (PTT) of the photoplethysmography (PPG) and pressure pulse from finger at the same time as a more convenient way to measure the BP. After recording the electrocardiogram (ECG), measuring the pressure pulse, and performing PPG, we calculated the PTT from the acquired signals. Then, we used a multiple regression analysis to measure the systolic and diastolic BP indirectly. Comparing the BP measured indirectly using the proposed algorithm and the real BP measured with a sphygmomanometer, the systolic pressure had a mean error of ${\pm}3.240$ mmHg and a standard deviation of 2.530 mmHg, while the diastolic pressure had a satisfactory result, i.e., a mean error of ${\pm}1.807$ mmHg and a standard deviation of 1.396 mmHg. These results are more superior than existing method estimating blood pressure using the one PTT and satisfy the ANSI/AAMI regulations for certifying a sphygmomanometer i.e., the measurement error should be within a mean error of ${\pm}5$ mmHg and a standard deviation of 8 mmHg. These results suggest the possibility of applying our method to a portable, long-term BP monitoring system.

Ultra fast Marx Generator of N2, SF6, N2-SF6 Mixture Gas based on Research Output Characteristics (초고속 Marx Generator의 N2, SF6, N2-SF6 혼합가스에 따른 출력 특성 연구)

  • Doo, Jin-Suk;Han, Seung-Moon;Huh, Chang-Su;Choi, Jin-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1850-1855
    • /
    • 2010
  • The application field of the pulse power is very wide. Recently, Pulse power technologies take a large place in several applications. Then, many civil and military applications proceed. Marx generator is widely used in high voltage applications. Marx generator is widely used in high voltage applications, such as eletromagnetic wave and power lasers. This paper, we described about the high voltage pulse generator. A compact size high voltage pulse generator with nanosecnd rise time has been fabricated and investigated experimentally. The marx generator has 2 stages. Each stage was constructed one charging capacitor, two electrodes and one charging resistor. A inductance structure is used in order to improve the switching performances fo the whole generator. The experiments of rise time in pure gas and mixtures of gases were described. We tested the Marx generator at different insulation gas. the results show that the dielectric strength of the $N_2-SF_6$ mixture was significantly increased compared with pure nitrogen gas. The experimental results show that the rise time characteristics of the Marx generator can be controlled through varying insulation gas.

Properties of a SiC-$ZrB_2$ Composite by condition of SPS on/off Pulse Time (SPS on/off Pulse Time 조건에 따른 SiC-$ZrB_2$ 복합체 특성)

  • Shin, Yong-Deok;Ju, Jin-Young;Lee, Hee-Seung;Park, Jin-Hyoung;Kim, In-Yong;Kim, Cheol-Ho;Lee, Jung-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.314-314
    • /
    • 2010
  • The SiC-$ZrB_2$ composites were fabricated by combining 40vol.% of Zirconium Diboride(hereafter, $ZrB_2$) powders with Silicon Carbide(hereafter, SiC) matrix. TheSiC+40vol.%$ZrB_2$ composites were manufactured through Spark Plasma Sintering(hereafter, SPS) under argon atmosphere, uniaxial pressure of 50MPa, heating rate of $100^{\circ}C$/min, sintering temperature of $1,500^{\circ}C$ and holding time of 5min. But one on/off pulse sequence(one pulse time: 2.78ms) is 10:9(hereafter, SZ10), and the other is 48:8(hereafter, SZ48). The physical and mechanical properties of the SZ12 and SZ48 were examined. Reactions between $\beta$-SiC and $ZrB_2$ were not observed via X-Ray Diffraction(hereafter, XRD) analysis. The apparent porosity of the SZ10 and SZ48 composites were 9.7455 and 12.2766%, respectively. The SZ10 composite, 593.87MPa, had higher flexural strength than the SZ48 composite, 324.78MPa, at room temperature. The electrical properties of the SiC-$ZrB_2$ composites had Positive Temperature Coefficient Resistance(hereafter, PTCR).

  • PDF

Analysis of free field for Acoustic Anechoic Chamber based on Time Stretched Pulse (Time Stretched Pulse를 이용한 무향실 자유음장 분석)

  • Kim, Keon-Wook
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.4
    • /
    • pp.111-119
    • /
    • 2012
  • Time Stretched Pulse (TSP) is used for transmitting and analyzing the impulse signal over the designated spatial place. However, if transfer functions of transmitter and receiver are unknown, performance investigation of free field in temporal domain is barely possible due to the overlap between the direct and indirect signal from the space. Generally, the free field or hemi-free field is evaluated by the Annex A of ISO 3745 in which utilizing the inverse square law with one-third octave band signals. In this paper, the author performs analysis of free field via applying TSP with inverse square law and the results are compared with the one-third octave band signals. According to the analysis of deviation between the corresponding signal and inverse square law model, the proposed TSP method provides the comparable performance index to the one-third octave band signal with reduced measuring time. Provided that the pre-whitening can be implementable by employing the speaker and microphone transfer function, further analyses from TSP compression are able to be performed such as multipath separation from time domain data. The anechoic chamber used in this experiment is verified conformance with ISO 3745 for free field and hemi-free field condition for limited frequency of the signal.

Propagation characteristic analysis and measurement of gaussian pulse signals on the microstrip line (마이크로스트립 선로상 가우시안 펄스신호의 전파특성 해석 및 측정)

  • Rhee, Seoung-Yeop;Shin, Ho-Sub;Kim, Nam;Kwan, Weon-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.6
    • /
    • pp.1425-1432
    • /
    • 1998
  • The propagation properties of Gaussian pulse signals on the microstrip line are investigated by the Kirschning & Jansen's approximated equation to meet the frequency range of a pulse, accuracy, and geometrical requiremtns of the microstrip line. The dispersion of pulse signals is analyzed regarding to the relative permittivity .epsilon.$_{r}$, substrate height h and strip width w of the microstrip line. To verify theoretical results, several samples of 50.OMEGA. microstrip lines are fabricated. And the characteristics of pulse propagation along these lines are simple measured using VNA(Vector Network Analyzer) with time-domain analysis function. A fairly good agreement has been found between the measured pulse waveforms and computer simulations.

  • PDF

Method for Feature Extraction of Radar Full Pulses Based on EMD and Chaos Detection

  • Guo, Qiang;Nan, Pulong
    • Journal of Communications and Networks
    • /
    • v.16 no.1
    • /
    • pp.92-97
    • /
    • 2014
  • A novel method for extracting frequency slippage signal from radar full pulse sequence is presented. For the radar full pulse sequence received by radar interception receiver, radio frequency (RF) and time of arrival (TOA) of all pulses constitute a two-dimensional information sequence. In a complex and intensive electromagnetic environment, the TOA of pulses is distributed unevenly, randomly, and in a nonstationary manner, preventing existing methods from directly analyzing such time series and effectively extracting certain signal features. This work applies Gaussian noise insertion and structure function to the TOA-RF information sequence respectively such that the equalization of time intervals and correlation processing are accomplished. The components with different frequencies in structure function series are separated using empirical mode decomposition. Additionally, a chaos detection model based on the Duffing equation is introduced to determine the useful component and extract the changing features of RF. Experimental results indicate that the proposed methodology can successfully extract the slippage signal effectively in the case that multiple radar pulse sequences overlap.

Analysis of Relations Between Physiologic Parameters and Pulse Transit Time on the Ultrasound Therapy (초음파 재활치료 시 PTT와 생리변수의 상관관계 분석)

  • Kim, Sung-Min;Choi, Sang-Hyuk;Lee, Man-Pyo;Choi, Byeong-Cheol;Jung, Whoi-Seong;Park, Sung-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1514-1520
    • /
    • 2007
  • Currently, the signal of the human body is measured with various methods, and a noninvasive investigation of various methods is useful diagnosis method. PTT(Pulse Transit Time) which is noninvasive investigation make use of to estimate the physiological phenomena. PTT has a latent information of cardiovascular system. So we have the experiments for analysis of the relations between PTT and physiological parameters. We examine to correlate to the physiological parameters, an age and degree of paralysis on the ultrasound therapy. The 40 patients who has a such paralysis join our experiment, and we obtain the PTT data that normal condition and states after ultrasound therapy. We study that PTT after the ultrasound therapy for patients who have a paralysis was related to an age and degree of paralysis.

Effect of thermal laser pulse in transversely isotropic Magneto-thermoelastic solid due to Time-Harmonic sources

  • Lata, Parveen;Kaur, Iqbal;Singh, Kulvinder
    • Coupled systems mechanics
    • /
    • v.9 no.4
    • /
    • pp.343-358
    • /
    • 2020
  • The present research deals with the time-harmonic deformation in transversely isotropic magneto thermoelastic solid with two temperature (2T), rotation due to inclined load and laser pulse. Generalized theory of thermoelasticity has been formulated for this mathematical model. The entire thermo-elastic medium is rotating with uniform angular velocity and subjected to thermally insulated and isothermal boundaries. The inclined load is supposed to be a linear combination of a normal load and a tangential load. The Fourier transform techniques have been used to find the solution to the problem. The displacement components, stress components, and conductive temperature distribution with the horizontal distance are computed in the transformed domain and further calculated in the physical domain using numerical inversion techniques. The effect of angle of inclination of normal and tangential load for Green Lindsay Model and time-harmonic source for Lord Shulman model is depicted graphically on the resulting quantities.