• Title/Summary/Keyword: Pulse injection

Search Result 245, Processing Time 0.038 seconds

A Study on the Contents of Fundamental Nursing Practice (기본간호학 실습교육현황과 실습내용 개선을 위한 조사 연구)

  • 이영휘;서화숙
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.3
    • /
    • pp.650-661
    • /
    • 1998
  • The purpose of this study was to provide fundamental data for determining contents of Fundamental Nursing Practice and developing desirable bedside nursing techniques for clinical nursing areas. Subjects for this study were 86 nurses who were employees of two university hospitals located in Seoul and a district area. Data were collected by questionnaires. Items of Fundamental Nursing Practice were classified into 72 items according to the result from content analysis of 9 textbooks of Fundamental Nursing. The results are as follows : 1) Items which above 80% of respondents practiced during the school inside practice or clinical nursing practice course were axillary temperature measurement, radial pulse measurement, respiratory rate measurement, application of oral hygiene, hand-washing technique, application of hot and cold bags, intramuscular injection technique, open bed-making, soap enema method, application of nelaton catheterization and oral and nasal suction methods. 2) Above 90% of respondents replied that all items except temperature measurement and bed-making were requisite contents for Fundamental Nursing Practice. Above 10% of respondents replied oral and rectal temperature measurement and bed-making were unnecessary content. 3) Above 90% of respondents replied that operating methods of all items except isolation technique, admission and discharge procedures, and retention enema in the Fundamental Nursing Practice course and clinical situation were consistent. The main reasons that respondents did not apply methods which they learned in the Fundamental Nursing Practice course to the clinical situation were 'insufficient time', 'colleagues were using different methods', 'insufficient supply of instuments' or 'inappropriate appliances'.

  • PDF

Response/Pressure Characteristics of $H_2O_2$ Monopropellant Thruster with the Reactor Design (반응기 설계인자에 따른 과산화수소 단일추진제 추력기의 응답속도 및 압력특성)

  • An, Sung-Yong;Lee, Jeong-Sub;Lee, Jae-Won;Cho, Seung-Hwan;Kwon, Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.49-52
    • /
    • 2009
  • The response times of monopropellant thrusters at a pulse mode were investigated experimentally as design parameters and feed pressure conditions. Five different model thrusters as injection direction/uniformity, aspect ratio of reactor, volumes of manifold and chamber were designed. As a results, two parameters, aspect ratio and manifold volume, were directly related to response characteristics. Additionally, chugging instability at reaction chamber was observed when pressure drop across the catalyst bed was increased due to high aspect ratio or when low pressure was built at reaction chamber.

  • PDF

Cathode Side Engineering to Raise Holding Voltage of SCR in a 0.5-㎛ 24 V CDMOS Process

  • Wang, Yang;Jin, Xiangliang;Zhou, Acheng;Yang, Liu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.6
    • /
    • pp.601-607
    • /
    • 2015
  • A set of novel silicon controlled rectifier (SCR) devices' characteristics have been analyzed and verified under the electrostatic discharge (ESD) stress. A ring-shaped diffusion was added to their anode or cathode in order to improve the holding voltage (Vh) of SCR structure by creating new current discharging path and decreasing the emitter injection efficiency (${\gamma}$) of parasitic Bipolar Junction Transistor (BJT). ESD current density distribution imitated by 2-dimensional (2D) TCAD simulation demonstrated that an additional current path exists in the proposed SCR. All the related devices were investigated and characterized based on transmission line pulse (TLP) test system in a standard $0.5-{\mu}m$ 24 V CDMOS process. The proposed SCR devices with ring-shaped anode (RASCR) and ring-shaped cathode (RCSCR) own higher Vh than that of Simple SCR (S_SCR). Especially, the Vh of RCSCR has been raised above 33 V. What's more, their holding current is kept over 800 mA, which makes it possible to design power clamp with SCR structure for on chip ESD protection and keep the protected chip away from latch-up risk.

Development of Few-second 40 kV, 280 kW High Voltage Pulse Power Supply (수 초 지속 40 kV, 280 kW 고전압 펄스전원장치 개발)

  • Kim, S.C.;Nam, S.H.;Heo, H.;Heo, H.;Moon, C.;Kim, J.H.;Oh, S.S.;Yang, J.W.;Sho, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.990-991
    • /
    • 2015
  • To drive a magnetron injection gun, thsi paper decribes a design, fabrication and analysis results of proposed compact capacitor charging power supply (CCPS) formed resonant full-bridge inverter for electron gun power supply (EGPS). EGPS needs the -40 kV output voltage and 280 kW output power for few seconds continuously and have to be designed for the rise and fall time to be less than 1 ms with the ripple stability of output voltage of lower than 1%. In order to meet the requirements, we used eight resonant full-bridge modules operated in parallel. Each resonant full-bridge module can supply the current of 0.9 A and the voltage of 40 kV, and is operated by N-phase shift switching pattern. In this paper, we present the design, simulation and test results of interleaved CCPS.

  • PDF

Novel Scanning Tunneling Spectroscopy for Volatile Adborbates

  • Choi, Eun-Yeoung;Lee, Youn-Joo;Lyo, In-Whan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.58-58
    • /
    • 2010
  • Reactive or unstable adsorbates are often difficult to study spectroscopically. They may have, for instance, resonance states lying close to the Fermi level, inducing them to desorb or decompose by the probe itself, low-energy tunneling electrons. In order to overcome this limitation, we developed a novel method, which we call x-ramp scan. The method sweeps the bias voltage, with the simutaneous scan along the imaging direction, in a constant current mode. This mapping yields the tip-height variation as a function of bias, or Z(V), at nominally always fresh surface. We applied this method to the investigation of methanol-induced molecular features, attributed to methoxy, found on NiAl(110) surface. These were produced by methanol molecules deposited by a pulse injection method onto the metallic surface. Our study shows adsorbed methoxy are very reactive to the bias voltage, rendering the standard spectroscopy useless. Our new x-ramp scan shows that the decomposition of adsorbates occurs at the sample bias of 3.63 V, and proceeds with the lifetime of a few milliseconds. The details of the method will be provided at the discussion.

  • PDF

Accidental High Epidural Block -A case report- (우발성 고위경막외차단 경험 1예 -증례보고-)

  • Park, Jung-Goo;Cheun, Jae-Kyu
    • The Korean Journal of Pain
    • /
    • v.8 no.1
    • /
    • pp.159-163
    • /
    • 1995
  • Accidental high epidural block is a rare but serious complication. It can result from many factors, which include the volume and concentration of drug, posture, puncture site, age, pregnancy or intra-abdominal mass, and patients' height and weight. We had a case of accidental high epidural block recently. This is a case report which was confirmed by an epiduragram. A healthy 50-year-old woman with a huge uterine myoma was scheduled for a total abdominal hysterectomy under continous epidural analgesia. Epidural catheterization was carried out smoothly. However, an unexpected hypotension was noticed after an epidural injection of 2% lidocaine 25 ml. Thereafter, the patient was intubated and her respiration was controlled during the operation. Using the 5mg of ephedrine, her blood pressure and pulse were well maintained. The scheduled operation was carried out for one hour uneventfully, but after the operation, she felt paresthesia on her hands in the recovery room. To differentiate between the high epidural and the subdural blocks. We injected 5 ml of a water soluble Niopam 300 through the catheter postoperatively. It was observed on the epiduragram that the catheter was placed in the epidural space. It was suggested that the high epidural block was induced from the widespread diffusion through the narrowed epidural space due to the engorgement of the epidural venous plexus by the patient's huge uterine myoma.

  • PDF

Subarachnoid Morphine for Perianal Postoperative Pain Control (미양(微量) Morphine 지주막하(蜘蛛膜下) 주입(注入)에 의(依)한 항문각위술후(肛門脚圍術後) 제통효과(除痛效果)에 대(對)한 임상연구(臨床硏究))

  • Rhim, Hwa-Taeg;Lee, Yeong-Sik;Oh, Hung-Kun
    • The Korean Journal of Pain
    • /
    • v.1 no.1
    • /
    • pp.98-102
    • /
    • 1988
  • In order to control the pain after hemorrhoidectomy and anal fistulectomy, 6 mg of 0.5% hyperbaric tetracaine without(control, group I) or wilt 0.3 mg(group II) or 0.5 mg (group III) of 0.1% morphine was injected with a 22 gauge spinal needle into the subarachnoid space through L 3-4 interspace of patients in lateral position. About 30 minutes in Fowler' sposition after injection, operation was performed in lithotomy position. All the patients who ha4 morphine showed remarkable relief of postoperative pain for an average of 27 hours. However, the dosage(0.3 or 0.5 mg) of morphine administered did not affect the duration of pain relief. Blood pressure, pulse rate and pupil size were unchanged in all patients. Dysuria after block developed for on average of 5,6, 13.2 and 14.6 hours in group I, II and III respectively. Most of these cases required urethral catheterization. Minor complications such as nausea, vomiting, itching, fever, burning sensation and paresthesia were observed 16.7, 20 and 20% of cases in group I, II and III respectively; however, no treatment was required.

  • PDF

A Study on Characteristics of Injected Fuel Pressure Waves of a Solenoid Type Diesel Common Rail Injector with Controlling Current Wave for Driving the Injector (솔레노이드 타입 디젤 커먼레일 인젝터 구동을 위한 전류 파형 변화에 따른 분사 연료 압력파 특성)

  • Kim, Kil Tae;Lee, Choong Hoon
    • Journal of ILASS-Korea
    • /
    • v.21 no.3
    • /
    • pp.155-161
    • /
    • 2016
  • Injected fuel pressure waves of a common rail injector with various current profiles supplied to the injecor were measured using Bosch method. In order to drive the common rail injector, the current in the solenoid should be controlled using what is known as a peak and hold pattern, which consists of a high current level with a short time duration (peak) in the first step and a low current level with a long time duration (hold) in the subsequent step. The current profile can be shaped by swithcing an injector driving power source with the peak and hold waves. The capture, compare and PWM (CCP) pin in the microprocessor was used to generate the combined peak and hold waves. The PWM square wave generated from the CCP pin has a duty ratio of 100% for the peak current and 10% or 30% for the hold pattern. Five patterns of the current profile were generated by combining the peak and hold wave. The common rail pressure is controlled at 75, 100, and 130 MPa. As the fuel rail pressure increases, the variations of the measured fuel injection pressure wave according to the current profiles decrease.

Hot-Fire Test and Performance Evaluation of Small Liquid-Monopropellant Thrusters under a Vacuum Environment (단일액체추진제 소형 추력기의 진공환경 연소시험 및 성능특성 평가)

  • Kim Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.4
    • /
    • pp.84-90
    • /
    • 2004
  • A performance evaluation is made in terms of thrust, impulse bit. and specific impulses for a set of mono-propellant hydrazine thrusters producing 0.95 lbf of nominal thrust at an inlet pressure of 350 psia. With a brief description on the hot-firing test configuration and procedures. a typical data obtained from steady-state firing mode is given directly showing the variational behavior of propellant supply pressure, mass flow rate, vacuum condition, and thrust. The performance features are successfully compared to the reference criteria of 1-lbf standard mono-propellant rocket engine. Additionally. a statistical inter-thruster treatment is concisely depicted for the justification of selected thrusters as a grouped member of flight model for spacecraft propulsion system.

Effects of Ethanol Extracts of Aconite Root on Respiration, Arterial Blood Pressure and Pressor Responses Elicited by Electrical Stimulation of the Hypothalamus in Cats (백부자(白附子)가 혈압(血壓), 호흡(呼吸) 및 시상하부(視床下部)의 전기자극(電氣刺戟)에 의(依)한 심맥관계반응(心脈管系反應)에 미치는 영향(影響))

  • Shin, Hong-Kee;Kim, Kee-Soon;Lee, Pyung-Hee
    • The Korean Journal of Physiology
    • /
    • v.7 no.2
    • /
    • pp.31-37
    • /
    • 1973
  • The effects of ethanol extacts of aconite root (Aconitum koreanum) on mean arterial pressure, heart rate, pulse pressure, and respiration were investigated and also studied the effect on electrical activation of the hypothalamus in cats. From the present experiment the following results were obtained. 1) On administering 5 mg or 10 mg aconite extracts per kg of body weight, the mean arterial blood pressure declined markedly possibly as the result of negative inotropic and chronotropic effects of aconite. 2) From the enhanced pressor responses to intravenously injected epinephrine, the existance of vasodilatory effect of the aconite was suggested. 3) After administration of aconite extract, no significant differences were observed in the presser responses to carotid occlusion and to electrical stimulation of the hypothalamus. It is, therefore, concluded that the aconite extract exerts no significant effect on the excitability of hypothalamus as well as medullary cardiovascular center of cats. 4) After administration of $5{\sim}10$ mg/kg aconite extracts, respiratory rate was increased while depth of respiration decreased. On the otherhand, respiratory rate was markedly decreased by injection of 20 mg/kg aconite into animal.

  • PDF