Synchronous Carrier-based Pulse Width Modulation Switching Method for Vienna Rectifier

  • Park, Jin-Hyuk;Yang, SongHee;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.604-614
    • /
    • 2018
  • This paper proposes a synchronous switching technique for a Vienna rectifier that uses carrier-based pulse width modulation (CB-PWM). A three-phase Vienna rectifier, similar to a three-level T-type converter with three back-to-back switches, is used as a PWM rectifier. Conventional CB-PWM requires six independent gate signals to operate back-to-back switches. When internal switches are operated synchronously, only three independent gate signals are required, which simplifies the construction of gate driver circuits. However, with this method, total harmonic distortion of the input current is higher than that with conventional CB-PWM switching. A reactive current injection technique is proposed to improve current distortion. The performance of the proposed synchronous switching method and the effectiveness of the reactive current injection technique are verified using simulations and experiments performed with a set of Vienna rectifiers rated at 5 kW.

Pulse Multiplication in Autotransformer Based AC-DC Converters using a Zigzag Connection

  • Singh, Bhim;Gairola, Sanjay
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.191-202
    • /
    • 2007
  • This paper deals with pulse multiplication in zigzag connected autotransformer based 12-pulse AC-DC converters feeding vector controlled induction motor drives (VCIMD) for improving the power quality at the point of common coupling (PCC) without using a Zero-Sequence-Blocking-Transformer (ZSBT). The proposed 24-pulse AC-DC converter is based on the principle of DC ripple re-injection technique for pulse multiplication and harmonic mitigation. The design of the autotransformer is carried out for the proposed AC-DC converter and the effect of load variation on VCIMD is also studied to demonstrate the effectiveness of the proposed AC-DC converter. Test results from a laboratory developed prototype, along with simulated results, are presented to validate the design and model of the proposed 24-pulse AC-DC converter.

2차 가진 제어 변조분사 특성 및 액체제트의 분무특성 (Spray Characteristics of a Modulated Liquid Jet through 2nd Pulsed Control)

  • 강영수;이인철;구자예
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.672-675
    • /
    • 2010
  • 본 연구에서는 저주파영역의 가진분무에 대하여 추가적인 내부가진을 수행함으로써 변조분사되는 분무특성에 대한 연구를 수행하였다. 회전식 가진장치를 사용하여 1차 가진을 생성한 후 2차 가진원인 마그네틱 밸브를 사용하여 변조하였다. 변조분무의 FFT결과와 분무패턴의 가시화를 통하여 관찰한 결과, 2차 가진 제어가 있는 변조분사의 경우 1차 가진만 있는 분사보다 분무의 상하 운동 진폭이 작으며 분무 하단류의 침투깊이가 증가하는 경향성이 발견되었다.

  • PDF

Characterization of ZnO for Transparent Thin Film Transistor by Injection Type Delivery System of ALD

  • Choi, Woon-Seop
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.860-863
    • /
    • 2007
  • ZnO nano film for transparent thin film transistors is prepared by injection type source delivery system of atomic layer deposition. By using this delivery system the source delivery pulse time can dramatically be reduced to 0.005s in ALD system. ZnO nanofilms obtained at $150^{\circ}C$ are characterized.

  • PDF

Analysis of the Phase Current Measurement Boundary of Three Shunt Sensing PWM Inverters and an Expansion Method

  • Cho, Byung-Geuk;Ha, Jung-Ik;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.232-242
    • /
    • 2013
  • To obtain phase currents information in AC drives, shunt sensing technology is known to show great performance in cost-effectiveness and therefore it is widely used in low cost applications. However, shunt sensing methods are unable to acquire phase currents in certain operation conditions. This paper deals with the derivation of the boundary conditions for phase current reconstruction in three-shunt sensing inverters and proposes a voltage injection method to expand the measurable areas. As the boundary conditions are deeply dependent on the switching patterns, they are typically analyzed on the voltage vector plane for space vector pulse width modulation (SVPWM) and discontinuous pulse width modulation (DPWM). In the proposed method, the voltage injection and its compensation are conducted within one sampling period. This guarantees fast current reconstruction and the injected voltage is decided so as to minimize the current ripple. In addition to the voltage injection method, a sampling point shifting method is also introduced to improve the boundary conditions. Simulation and experimental results are presented to verify the boundary condition derivation and the effectiveness of the proposed voltage injection method.

Comparative efficacy of three topical anesthetics on 7-11-year-old children: a randomized clinical study

  • Dasarraju, Rupak Kumar;SVSG, Nirmala
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권1호
    • /
    • pp.29-37
    • /
    • 2020
  • Background: This study evaluated the efficacy of three intraoral topical anesthetics in reducing the injection needle prick pain from local anesthetic among children aged 7-11 years old. Methods: It is a prospective, Interventional, parallel design, single-blind, randomized clinical trial in which subjects (n=90) aged 7-11 years were included in the study based on an inclusion criteria. Subjects were divided into three groups based on computer-generated randomization with an allocation ratio of 1:1:1. Groups A, B, and C received benzocaine 20% jelly (Mucopain gel, ICPA health products Ltd, Ankleshwar, India), cetacaine anesthetic liquid (Cetylite Industries, Inc, Pennsauken, NJ), and EMLA cream (2% AstraZeneca UK Ltd, Luton, UK), respectively, according to manufacturer's instructions, for 1 minute prior to local anesthetic injection. After application of topical anesthetic agent, for all the groups, baseline pre-operative (prior to topical anesthetic administration) and post-operative scores (after local anesthetic administration) of pulse rate was recorded using Pulse oximeter (Gibson, Fingertip Pulse Oximeter, MD300C29, Beijing Choice Electronic). Peri-operative (i.e., during the administration of local anesthesia) scores were recorded using Face, Legs, Activity, Cry, Consolability (FLACC) Scale, Modified Children hospital of Eastern Ontario Pain Scale (CPS) behavior rating scale, and Faces Pain Scale (FPS-R) - Revised (For self-reported pain). Direct self-reported and physiological measures were ascertained using FPS-R - Revised and Pulse oximeter, respectively, whereas CPS and FLACC scales assessed behavioral measures. To test the mean difference between the three groups, a one way ANOVA with post hoc tests was used. For statistical significance, a two-tailed probability value of P < 0.05 was considered as significant. Results: The Cetacaine group had significantly lower pain scores for self-report (P < 0.001), behavioral, and physiological measures (P < 0.001) than the other two groups. However, there was no significant difference between the Benzocaine group and EMLA group during palatal injection prick. Conclusion: Cetacaine can be considered as an effective topical anesthetic agent compared to benzocaine 20% jelly (Mucopain gel) and EMLA cream.

메틸삼염화규소로부터 탄화규소 침착의 Pulse-CVI에 대한 수치모사 연구 (Studies on the Mathematical Modelling of the Pulse-CVI for the Infiltration of Siliconcarbide from Methyltrichlorosilane)

  • 김인구;김민기;정귀영
    • Composites Research
    • /
    • 제18권5호
    • /
    • pp.27-33
    • /
    • 2005
  • 본 연구에서는 펄스-CVI (Chemical Vapor Infiltration)에 의해 탄화규소/탄소 복합재료를 제조하는 공정에 대한 수치모사가 행해졌다. 각 펄스가 가스 주입시간, 반응시간, 배출시간으로 구성될 때, 반응시간과 배출시간의 영향이 관찰되었다. 또한 반응가스 농도와 압력의 영향이 연구되었다. 탄소프리폼에의 탄화규소의 균일한 침착과 반응시간 단축을 위한 펄스-CVI공정의 이점이 확인되었다.

산삼 약침이 정상 중년여성의 맥파요인에 미치는 영향 (Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture Original Articles)

  • 박상욱;김이순;황원덕;김경철
    • 대한약침학회지
    • /
    • 제14권1호
    • /
    • pp.35-49
    • /
    • 2011
  • Objectives: The aim of this experiment is to know about Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture. Methods: First 20 Middle Aged women are diagnosed by pulse diagnosis, and then Mountain Cultivated Ginseng Pharmacopuncture(1 injection 20cc) were injected. 30 minutes later, pulse diagnosis again performed. As a result, method of one-group pretest-posttes design were used for evaluation. Results: T(Total pulse cycle) time statistically significant increased on both left and right chon, kwan, cheok. T4 time statistically significant increased on both left and right chon, kwan, cheok. T4-T1/T indexs except left cheokmaek, Right cheokmaek observation area decreased significantly in four sites. Wm(indicating high pressure retention time) indexs increased significantly in the five sites were observed except right chon maek. Conclusions: Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture increased T, T4, Wm and decreased T4-T1/T indexs. The results of this experiment, Mountain Cultivated Ginseng Pharmacopuncture induced to increase the Pulse-wave's stability and strength.

충돌 분무의 성장에 미치는 분사압과 배압의 영향에 관한 연구 (A study on the effect of injection pressure and ambient pressure for the growth of impinging spray)

  • 차건종;서경일;김덕줄
    • 대한기계학회논문집B
    • /
    • 제21권11호
    • /
    • pp.1458-1465
    • /
    • 1997
  • This study investigated the effects of pressure on the growth of an impinging spray. We obtained the frozen images which were scattered by Nd ; YAG laser light (pulse width : 7 ns) using synchronization circuit made in the laboratory. For an impinging spray a growth of the penetration length was progressed with increase of the injection pressure but an ambient pressure restrained its growth. The effect of an ambient pressure on penetration was larger than that of an injection pressure. The pressure ratio had an effect on the penetration growth rate. The thickness growth rate depended on both the injection pressure and the ambient pressure compositively. A lower injection pressure or a higher ambient pressure was required for spatial distribution of impinging spray.

능동형 교류 전력 필터에 의한 고조파 보상전류의 새로운 주입방식 (A New Injection Method of Harmonic Compensation Current by Active AC Power Filter)

  • 박민호;최규하
    • 대한전기학회논문지
    • /
    • 제34권9호
    • /
    • pp.361-367
    • /
    • 1985
  • A new injection method is proposed for active power filters to eliminate AC harmonics in ac input current of nonlinear loads such as rectifiers. By injecting the PWM current determined by the proposed injection method, all the harmonics up to order nn can be eliminated to exactly zero. This PWM injection current can be generated by sampling total harmonic wave at the rate of M and the sampled values are converted into the proposed PWM wave with N pulse-width variables and adjustable current magnitude Im. These variables are deetermined by solving a set of N nonlinear harmonic equations and the harmonic-elimination characteristics of the new injection are investigated through digital computer sinmulation. Also by comparing between the simulated results and the ones synthesized by data stored in EPROM, the possibility of the suggested injection method can be shown.