• 제목/요약/키워드: Pulse injection

검색결과 245건 처리시간 0.029초

기본간호학 실습교육현황과 실습내용 개선을 위한 조사 연구 (A Study on the Contents of Fundamental Nursing Practice)

  • 이영휘;서화숙
    • 대한간호학회지
    • /
    • 제28권3호
    • /
    • pp.650-661
    • /
    • 1998
  • The purpose of this study was to provide fundamental data for determining contents of Fundamental Nursing Practice and developing desirable bedside nursing techniques for clinical nursing areas. Subjects for this study were 86 nurses who were employees of two university hospitals located in Seoul and a district area. Data were collected by questionnaires. Items of Fundamental Nursing Practice were classified into 72 items according to the result from content analysis of 9 textbooks of Fundamental Nursing. The results are as follows : 1) Items which above 80% of respondents practiced during the school inside practice or clinical nursing practice course were axillary temperature measurement, radial pulse measurement, respiratory rate measurement, application of oral hygiene, hand-washing technique, application of hot and cold bags, intramuscular injection technique, open bed-making, soap enema method, application of nelaton catheterization and oral and nasal suction methods. 2) Above 90% of respondents replied that all items except temperature measurement and bed-making were requisite contents for Fundamental Nursing Practice. Above 10% of respondents replied oral and rectal temperature measurement and bed-making were unnecessary content. 3) Above 90% of respondents replied that operating methods of all items except isolation technique, admission and discharge procedures, and retention enema in the Fundamental Nursing Practice course and clinical situation were consistent. The main reasons that respondents did not apply methods which they learned in the Fundamental Nursing Practice course to the clinical situation were 'insufficient time', 'colleagues were using different methods', 'insufficient supply of instuments' or 'inappropriate appliances'.

  • PDF

반응기 설계인자에 따른 과산화수소 단일추진제 추력기의 응답속도 및 압력특성 (Response/Pressure Characteristics of $H_2O_2$ Monopropellant Thruster with the Reactor Design)

  • 안성용;이정섭;이재원;조승환;권세진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.49-52
    • /
    • 2009
  • 과산화수소 단일추진제 추력기의 설계인자에 따른 펄스 응답속도에 대한 연구를 실험적으로 수행하였다. 서로 다른 다섯 개의 50 Newton 급 추력기를 이용하여 인젝터 분사 방향/균일도, 반응기 세장비, 매니폴더 및 챔버부피의 변화에 따른 응답속도를 측정하였으며, 가압압력에 따른 차이 또한 살펴보았다. 그 결과 다른 요소에 비해 반응기 세장비 및 매니폴더 부피가 응답속도에 직접적인 관련이 있었다. 또한 반응기 직경/길이비가 증가하여 압력 손실이 크거나 반응챔버의 압력이 낮게 형성되는 경우 압력 불안정성이 나타났다.

  • PDF

Cathode Side Engineering to Raise Holding Voltage of SCR in a 0.5-㎛ 24 V CDMOS Process

  • Wang, Yang;Jin, Xiangliang;Zhou, Acheng;Yang, Liu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권6호
    • /
    • pp.601-607
    • /
    • 2015
  • A set of novel silicon controlled rectifier (SCR) devices' characteristics have been analyzed and verified under the electrostatic discharge (ESD) stress. A ring-shaped diffusion was added to their anode or cathode in order to improve the holding voltage (Vh) of SCR structure by creating new current discharging path and decreasing the emitter injection efficiency (${\gamma}$) of parasitic Bipolar Junction Transistor (BJT). ESD current density distribution imitated by 2-dimensional (2D) TCAD simulation demonstrated that an additional current path exists in the proposed SCR. All the related devices were investigated and characterized based on transmission line pulse (TLP) test system in a standard $0.5-{\mu}m$ 24 V CDMOS process. The proposed SCR devices with ring-shaped anode (RASCR) and ring-shaped cathode (RCSCR) own higher Vh than that of Simple SCR (S_SCR). Especially, the Vh of RCSCR has been raised above 33 V. What's more, their holding current is kept over 800 mA, which makes it possible to design power clamp with SCR structure for on chip ESD protection and keep the protected chip away from latch-up risk.

수 초 지속 40 kV, 280 kW 고전압 펄스전원장치 개발 (Development of Few-second 40 kV, 280 kW High Voltage Pulse Power Supply)

  • 김성철;남상훈;허훈;공형섭;문철;김정호;오승섭;양종원;소준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.990-991
    • /
    • 2015
  • To drive a magnetron injection gun, thsi paper decribes a design, fabrication and analysis results of proposed compact capacitor charging power supply (CCPS) formed resonant full-bridge inverter for electron gun power supply (EGPS). EGPS needs the -40 kV output voltage and 280 kW output power for few seconds continuously and have to be designed for the rise and fall time to be less than 1 ms with the ripple stability of output voltage of lower than 1%. In order to meet the requirements, we used eight resonant full-bridge modules operated in parallel. Each resonant full-bridge module can supply the current of 0.9 A and the voltage of 40 kV, and is operated by N-phase shift switching pattern. In this paper, we present the design, simulation and test results of interleaved CCPS.

  • PDF

Novel Scanning Tunneling Spectroscopy for Volatile Adborbates

  • Choi, Eun-Yeoung;Lee, Youn-Joo;Lyo, In-Whan
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.58-58
    • /
    • 2010
  • Reactive or unstable adsorbates are often difficult to study spectroscopically. They may have, for instance, resonance states lying close to the Fermi level, inducing them to desorb or decompose by the probe itself, low-energy tunneling electrons. In order to overcome this limitation, we developed a novel method, which we call x-ramp scan. The method sweeps the bias voltage, with the simutaneous scan along the imaging direction, in a constant current mode. This mapping yields the tip-height variation as a function of bias, or Z(V), at nominally always fresh surface. We applied this method to the investigation of methanol-induced molecular features, attributed to methoxy, found on NiAl(110) surface. These were produced by methanol molecules deposited by a pulse injection method onto the metallic surface. Our study shows adsorbed methoxy are very reactive to the bias voltage, rendering the standard spectroscopy useless. Our new x-ramp scan shows that the decomposition of adsorbates occurs at the sample bias of 3.63 V, and proceeds with the lifetime of a few milliseconds. The details of the method will be provided at the discussion.

  • PDF

우발성 고위경막외차단 경험 1예 -증례보고- (Accidental High Epidural Block -A case report-)

  • 박정구;전재규
    • The Korean Journal of Pain
    • /
    • 제8권1호
    • /
    • pp.159-163
    • /
    • 1995
  • Accidental high epidural block is a rare but serious complication. It can result from many factors, which include the volume and concentration of drug, posture, puncture site, age, pregnancy or intra-abdominal mass, and patients' height and weight. We had a case of accidental high epidural block recently. This is a case report which was confirmed by an epiduragram. A healthy 50-year-old woman with a huge uterine myoma was scheduled for a total abdominal hysterectomy under continous epidural analgesia. Epidural catheterization was carried out smoothly. However, an unexpected hypotension was noticed after an epidural injection of 2% lidocaine 25 ml. Thereafter, the patient was intubated and her respiration was controlled during the operation. Using the 5mg of ephedrine, her blood pressure and pulse were well maintained. The scheduled operation was carried out for one hour uneventfully, but after the operation, she felt paresthesia on her hands in the recovery room. To differentiate between the high epidural and the subdural blocks. We injected 5 ml of a water soluble Niopam 300 through the catheter postoperatively. It was observed on the epiduragram that the catheter was placed in the epidural space. It was suggested that the high epidural block was induced from the widespread diffusion through the narrowed epidural space due to the engorgement of the epidural venous plexus by the patient's huge uterine myoma.

  • PDF

미양(微量) Morphine 지주막하(蜘蛛膜下) 주입(注入)에 의(依)한 항문각위술후(肛門脚圍術後) 제통효과(除痛效果)에 대(對)한 임상연구(臨床硏究) (Subarachnoid Morphine for Perianal Postoperative Pain Control)

  • 임화택;이영식;오흥근
    • The Korean Journal of Pain
    • /
    • 제1권1호
    • /
    • pp.98-102
    • /
    • 1988
  • In order to control the pain after hemorrhoidectomy and anal fistulectomy, 6 mg of 0.5% hyperbaric tetracaine without(control, group I) or wilt 0.3 mg(group II) or 0.5 mg (group III) of 0.1% morphine was injected with a 22 gauge spinal needle into the subarachnoid space through L 3-4 interspace of patients in lateral position. About 30 minutes in Fowler' sposition after injection, operation was performed in lithotomy position. All the patients who ha4 morphine showed remarkable relief of postoperative pain for an average of 27 hours. However, the dosage(0.3 or 0.5 mg) of morphine administered did not affect the duration of pain relief. Blood pressure, pulse rate and pupil size were unchanged in all patients. Dysuria after block developed for on average of 5,6, 13.2 and 14.6 hours in group I, II and III respectively. Most of these cases required urethral catheterization. Minor complications such as nausea, vomiting, itching, fever, burning sensation and paresthesia were observed 16.7, 20 and 20% of cases in group I, II and III respectively; however, no treatment was required.

  • PDF

솔레노이드 타입 디젤 커먼레일 인젝터 구동을 위한 전류 파형 변화에 따른 분사 연료 압력파 특성 (A Study on Characteristics of Injected Fuel Pressure Waves of a Solenoid Type Diesel Common Rail Injector with Controlling Current Wave for Driving the Injector)

  • 김길태;이충훈
    • 한국분무공학회지
    • /
    • 제21권3호
    • /
    • pp.155-161
    • /
    • 2016
  • Injected fuel pressure waves of a common rail injector with various current profiles supplied to the injecor were measured using Bosch method. In order to drive the common rail injector, the current in the solenoid should be controlled using what is known as a peak and hold pattern, which consists of a high current level with a short time duration (peak) in the first step and a low current level with a long time duration (hold) in the subsequent step. The current profile can be shaped by swithcing an injector driving power source with the peak and hold waves. The capture, compare and PWM (CCP) pin in the microprocessor was used to generate the combined peak and hold waves. The PWM square wave generated from the CCP pin has a duty ratio of 100% for the peak current and 10% or 30% for the hold pattern. Five patterns of the current profile were generated by combining the peak and hold wave. The common rail pressure is controlled at 75, 100, and 130 MPa. As the fuel rail pressure increases, the variations of the measured fuel injection pressure wave according to the current profiles decrease.

단일액체추진제 소형 추력기의 진공환경 연소시험 및 성능특성 평가 (Hot-Fire Test and Performance Evaluation of Small Liquid-Monopropellant Thrusters under a Vacuum Environment)

  • 김정수
    • 한국추진공학회지
    • /
    • 제8권4호
    • /
    • pp.84-90
    • /
    • 2004
  • 추진제 주입압력 350 psia 에서 0.95 lbf 의 정상상태 공칭추력을 내는 단일액체추진제 하이드라진 추력기의 성능평가 결과를 추력, 임펄스 비트, 비추력 등을 통하여 제시한다. 연소시험 형상과 절차에 대한 간략한 묘사와 더불어 정상상태 연소모드로부터 얻어지는 추진제 공급압력. 질량유량, 추력기 작동환경 진공도, 그리고 추력 등의 변이거동에 대한 전형적인 결과를 검토한다. 제시된 추력기 성능은 1-lbf급 표준형 단일추진제 로켓엔진의 기준성능에 성공적으로 비교된다. 선별된 추력기군을 위성체 추진시스템의 비행모델로 채택하기 위한 추력기간 성능편차에 대해 부연한다.

백부자(白附子)가 혈압(血壓), 호흡(呼吸) 및 시상하부(視床下部)의 전기자극(電氣刺戟)에 의(依)한 심맥관계반응(心脈管系反應)에 미치는 영향(影響) (Effects of Ethanol Extracts of Aconite Root on Respiration, Arterial Blood Pressure and Pressor Responses Elicited by Electrical Stimulation of the Hypothalamus in Cats)

  • 신홍기;김기순;이병희
    • The Korean Journal of Physiology
    • /
    • 제7권2호
    • /
    • pp.31-37
    • /
    • 1973
  • The effects of ethanol extacts of aconite root (Aconitum koreanum) on mean arterial pressure, heart rate, pulse pressure, and respiration were investigated and also studied the effect on electrical activation of the hypothalamus in cats. From the present experiment the following results were obtained. 1) On administering 5 mg or 10 mg aconite extracts per kg of body weight, the mean arterial blood pressure declined markedly possibly as the result of negative inotropic and chronotropic effects of aconite. 2) From the enhanced pressor responses to intravenously injected epinephrine, the existance of vasodilatory effect of the aconite was suggested. 3) After administration of aconite extract, no significant differences were observed in the presser responses to carotid occlusion and to electrical stimulation of the hypothalamus. It is, therefore, concluded that the aconite extract exerts no significant effect on the excitability of hypothalamus as well as medullary cardiovascular center of cats. 4) After administration of $5{\sim}10$ mg/kg aconite extracts, respiratory rate was increased while depth of respiration decreased. On the otherhand, respiratory rate was markedly decreased by injection of 20 mg/kg aconite into animal.

  • PDF