Pulse Wave Velocity Measured by Radial Artery Clip-type Pulsimeter Equipped with a Hall Device and Electrocardiogram (홀소자가 구비된 요골동맥 집게형맥진기와 심전도로 측정된 맥파전달속도)

  • Lee, Kyu-Hwan;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.130-134
    • /
    • 2013
  • The clip-type pulsimeter equipped with a magnetic sensing Hall device and the most popular body sign of the electrocardiogram (ECG) were investigated in order to analyze the pulse wave velocity (PWV). The PWV simultaneously calculated by means of time difference between the maximum peak of ECG pulse wave and the starting point of radial artery pulse wave, and distance difference between the heart position and the radial wrist position. The PWV analyzed from the clinical data was a wider scope of 5~7 m/s with an average value of 6 m/s. By the prediction of blood vessel's elasticity from the analysis of PWV, it may be useful for developing an oriental-western diagnostic medical signal device for a U-health-care system in the future.

Analysis of Both Hands' Two Pulse Waveforms using a Clip-type Pulsimeter Equipped with Magnetic Sensing Hall Device

  • Rhee, Jin-Kyu;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.183-187
    • /
    • 2013
  • Two concurrent signals of the pulse wave measured from both hands' radial artery in un-pressurization condition using the prototype model of two clip-type pulsimeters with a permanent magnet and Hall device are investigated. The phase differences of two pulse waves from 22 subjects have some distinct points according to the handedness. Thus, the propagation of the pulse wave calculated from phase difference is both fast and slow to each other. It is confirmed that this phenomenon comes from the difference of blood vessel hardness between right- and left-hand of each subject rather than a quantity of muscle.

Fabrication and Identification of Marx Generator for the Design of High Power Backward Wave Oscillator (대 전력 후진파 발진기의 설계를 위한 마르크스 발생기의 제작 및 검증)

  • Kim, Won-Seop;Hwang, Nak-Hun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.391-399
    • /
    • 1999
  • We have designed the backward wave oscillator, a power-pulsed generator oscillated at 20 GHz has higher frequency than current one. An absolute instability linear analysis was used for the purpose of designing the slow wave structure. A large diameter (D/$\lambda$=4.8) of the slow wave structure was adopted to prevent the breakdown brought about by the increase of power density. We have fabricated a marx generator, pulse forming line and diode. And the development of a compact pulsed power generator with short period and low amplitude is expected.

  • PDF

Corrosion visualization under organic coating using laser ultrasonic propagation imaging

  • Shi, Anseob;Park, Jinhwan;Lee, Heesoo;Choi, Yunshil;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.29 no.2
    • /
    • pp.301-309
    • /
    • 2022
  • Protective coatings are most widely used anticorrosive structures for steel structures. The corrosion under the coating damages the host material, but this damage is completely hidden. Therefore, a field-applicable under-coating-corrosion visualization method has been desired for a long time. Laser ultrasonic technology has been studied in various fields as an in situ nondestructive inspection method. In this study, a comparative analysis was carried out between a guided-wave ultrasonic propagation imager (UPI) and pulse-echo UPI, which have the potential to be used in the field of under-coating-corrosion management. Both guided-wave UPI and pulse-echo UPI were able to successfully visualize the corrosion. Regarding the field application, the guided-wave UPI performing Q-switch laser scanning and piezoelectric sensing by magnetic attachment exhibited advantages owing to the larger distance and incident angle in the laser measurement than those of the pulse-echo UPI. Regarding the corrosion visualization methods, the combination of adjacent wave subtraction and variable time window amplitude mapping (VTWAM) provided acceptable results for the guided-wave UPI, while VTWAM was sufficient for the pule-echo UPI. In addition, the capability of multiple sensing in a single channel of the guided-wave UPI could improve the field applicability as well as the relatively smaller size of the system. Thus, we propose a guided-wave UPI as a tool for under-coating-corrosion management.

A Study on Arterial Characterization using Finger-Toe Index (FTI) (지첨-족지 지수에 의한 동맥 혈관 특성화 연구)

  • Byeon, M.K.;Han, S.W.;Huh, W.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.777-785
    • /
    • 2007
  • In this paper, Finger-Toe Index (FTI) is proposed as an analytic parameter for the characterization of arterial vessel. Different from the currently being employed pulse wave velocity (PWV) information of the volume pulse wave measured from 4 arterial channels, the proposed FTI uses the ratio of the shorter of the two up-stroke time of PPG from fingers ($UT_{finger}$) and that of PPG (Photoplethysmography) from toes ($UT_{toe}$). To verify the usefulness of the proposed method, Finger-Toe Indexes were derived from the volume pulse waves acquired from 50 people under examination aged from 12 to 81 years old, and they were then compared with blood pressure ankle-brachial index (ABI). It was successfully demonstrated that the arterial stiffness can be estimated with respect to age and FTI is more strongly correlated with the pulse transit time than ABI. From the regression analysis, we also found that FTI has significant correlation PWV for a quantitative index of arterial stiffness and provides more accurate information than ABI for the characterization of arterial vessel.

Implementation of High Accurate Level Sensor System using Pulse Wave Type Magnetostriction Sensor (펄스파 자왜 센서를 이용한 고정밀 액위 센서 시스템의 실현에 관한 연구)

  • Choi, Woo-Jin;Lee, John-Tark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.395-400
    • /
    • 2013
  • In this paper, we introduce the implementation of high accurate level sensor system using the pulse wave type magnetostriction sensor. When a current pulse flows along the waveguide, the magnetic field also propagates towards the end of waveguide. When this magnetic field just passes the position of the magnet for level detection, the resultant magnetic field by these two magnetic fields makes a torsional reflected signal. This is used to calculate the time difference between a interrogation pulse wave and this torsional reflected signal. The key elements and characteristics were investigated to implement level sensor system based on this principle. We introduce a method to calculate the speed of ultrasonic reflected signal and how to make a model of sensing coil. In particular, we experiment with the characteristics of the torsional reflected signal according to the changes of the interrogation voltage and displacement. To make high accurate level sensor system, two methods were compared. One is to use the comparator and time counter, the other is STFT(Short Time FFT) which is capable of the time-frequency analysis.

Analysis of Magnetic Field Variation for Pulse Wave by Using Finite Element Method (유한 요소법을 이용한 맥진 파형의 자기장 변화 분석)

  • Park, Tae-Young;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.3
    • /
    • pp.90-96
    • /
    • 2014
  • The magnetic field variation by the permanent magnet fluctuation positioned on a "Chwan" of wrist according to the movement of radial artery was generated. The clip-type pulsimeter equipped with a Hall device sensing magnetic field pulse movement analyzed the characteristics of pulse wave as output signals. The magnetic field curve and pulse waveform simulated by the finite element method were compared and analyzed with each other. Also, the variation of magnetic field distribution one permanent magnet investigated by the fabrication of clip-type pulsimeter simulator. This result suggests that the clip-type pulsimeter can be used the reproducible and efficacious oriental diagnostic medical instrument.

A Effect of Photo Dynamic Therapy for LAZER Wave Mode (방사모드에 따른 레이저 치료 효과)

  • Choi, Deog Su;Lim, Hyun Soo;Lee, Byung Koo;Kenar, Necla
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.134-139
    • /
    • 2016
  • US Food and Drug Administration (FDA) approved as a innovative cure for cancer, 1996. The effect is death of cancer cells through necrosis, apoptosis. Mainly the Continuous Wave mode (CW) use for PDT Laser. It sting, the question including itch, and etc. Reportedly, the increase of temperature with the perforated edema, ulcer, necrosis. The Thermal relaxation time and Oxygen recovery time is necessary. To give a normal oxygen recovery time of the cell, used Pulse mode. Progress, it was Burst Pulse mode when easing the thermal wake, the simplicity was secured, the PDT effect is good. Excepted in control group CW, Pulse, Burst pulse mode were incubated with various concentrations of 5-aminolevulinic acid hydrochloride (ALA-5). The tumor size reduction CW mode (44%), Pulse mode (48%), Burst pulse mode (53%) at 4 week after PDT with 0.3, 0.3, 0.3 mg/ml of ALA-5. After 4 hours, investigation of 100, 100, $100J/cm^2$ laser irradiation. The pulse mode was superior in expirimental data analysis. And it was the Burst pulse mode edge head of a family effect.

Analysing of pulse wave parameter and typical pulse pattern for diagnosis in floating and sinking pulses (${\cdot}$ 침맥 진단에 유용한 맥상 파라메터 및 대표맥상 분석)

  • Lee, Yu-Jung;Lee, Jeon;Choi, Eun-Ji;Lee, Hae-Jung;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.2 s.17
    • /
    • pp.93-101
    • /
    • 2006
  • Pulse feeling is one of the most important diagnosis method in Oriental medicine. But it is not easy to make an objective and standardized diagnosis. In this study, we found how to quantify diagnosis. Specially dally the high practicality in clinic, we search some parameters especially well-related to floating and sinking pulse by statistic analysis. By extension, we find the pulse patterns of the floating and sinking pulse. We choose 15 subjects diagnosed as floating pulse and 15 subjects diagnosed as sinking pulse by oriental doctors. And their pulse signals were acquired by Pulse analyzer which has piezoresistive pressure sensor. For the quantification of the floating and sinking pulse, at first, we examined the parameters which were highly correlated with oriental doctor's diagnosis. And then we derived pulse patterns of the floating-sinking pulse from preprocessed signal and its ensemble average. We also looked trend variation (PH-Curve) between contact and pulse pressure. As a result, statistically there is the biggest difference between contact pressure, the maximum pulse pressure, diastolic area (Ad) and floating and sinking data. Through the PH-Curve, which represented the relationship between contact and pulse pressure, we could divide the floating and sinking pulse clearly. As a basic research of pulse diagnosis algorithm, we can contribute to select essential parameters in diagnosis algorithm And using these diagnosis method, we expect to find typical pulse patterns and some useful parameters about other pulses like slow/rapid, large/fine pulse and so on. We hope that this study will contribute pulse objectification.

  • PDF

A study on the insulation detection for electrical machnes by corona pulse technique (Corona pulse 검출에 의한 전력기기절연진단에 대한-고찰)

  • 성영권;정성계;김왕곤
    • 전기의세계
    • /
    • v.16 no.5
    • /
    • pp.15-18
    • /
    • 1967
  • This paper shows the analysis for mechanisms of corona pulse caused by dielectric breakdown, and for the results of observed values on an actual machines with the this corona pulse technique. Although the above results are not directly related with the generation, numbers or wave of the corona pulse, it may possibly be chanced a judgement of dielectric breakdown and one of better synthetic judgement methods for actual electrical machines.