• Title/Summary/Keyword: Pulse To Pulse Stability

Search Result 229, Processing Time 0.029 seconds

Phase Change Characteristics of Aux(Ge2Sb2Te5)1-x (x=0, 0.0110, 0.0323, 0.0625) Thin Film for PRAM (PRAM을 위한 Aux(Ge2Sb2Te5)1-x (x=0, 0.0110, 0.0323, 0.0625) 박막의 상변환 특성)

  • Shin, Jae-Ho;Baek, Seung-Cheol;Kim, Byung-Cheul;Lee, Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.404-409
    • /
    • 2011
  • An amorphous $Ge_2Sb_2Te_5$ thin film is one of the most commonly used materials for phase-change data storage. In this study, $Au_x(Ge_2Sb_2Te_5)_{1-x}$ thin film amorphous-to-crystalline phase-change rate were evaluated in using 658 nm laser beam. The focused laser beam with a diameter <10 ${\mu}m$ was illuminated in the power (P) and pulse duration (t) ranges of 1-17 mW and 10-460 ns, respectively, with subsequent detection of the responsive signals reflected from the film surface. We also evaluated the material characteristics, such as optical absorption and energy gap, crystalline phases, and sheet resistance of as-deposited and annealed films. The result of experiments showed that the thermal stability of the $Ge_2Sb_2Te_5$ film is largely improved by adding Au.

The study on oriental and western medicine of esophagitis (식도염(食道炎)에 대(對)한 동서의학적(東西醫學的) 고찰(考察))

  • Choi, Chang-woo;Son, Chang-gyu;Cho, Chong-kwan
    • Journal of Haehwa Medicine
    • /
    • v.10 no.2
    • /
    • pp.91-96
    • /
    • 2002
  • We arrived at the following conclusions after we have studied esophagitis through the literatures of oriental and western medicine. 1. The western medical causes of acute esophagitis are corrosiveness chemical material, esophageal or gastric disease, trauma, blister stomatitis, filamentous fungus infection and uremia of chronic patient etc, and the oriental medical causes are qi and blood stagnation, blood stasis and stagnation, stagnant phlegm by coldness, heating, dyspepsia and food poisoning etc. 2. The western medical causes of chronic esophagitis are malfunction of lower esophageal sphincter, esophageal tom chink and hernia, increase of gastric pressure by overeating, fatness, pregnancy and ascites etc, and the oriental medical causes are asthenic cardiac qi, hepatic qi attacking stomach by seven kinds of depression, cold-damp stagnation and insufficiency of gastric qi by overeating, excessive drinking and sexual indulgence etc. 3. The main symptoms of acute esophagitis are severe chest pain, instantly vomiting, swallowing pain etc, and chronic esophagitis are occasionally light chest pain, heart bum, anorexia, dysphagia, dizziness, general body weakness etc. These symptoms are come under thoracic obstruction, acid regurgitation, vomiting and chest pain of oriental medicine. 4. The western medical diagnoses of acute and chronic esophagitis have used radiation test, esophageal endoscopy, esophageal pressure test and biopsy etc, and the oriental medical diagnoses have used syndrome differentiation by four examination of inspection, listening and smelling examination, inquiring, pulse-taking and palpitation. 5. The western medical treatments of acute esophagitis have regarded preservation stability of esophagus as a principle, and the oriental medical treatments mainly have used expelling pathogen of expelling cold and regulating qi, cooling and removing stasis, promoting blood circulation to remove blood stasis, eliminating phlegm and regulating qi. 6. The western medical treatments of chronic esophagitis have regarded decrease flowing backward of gastric juice as a purpose, and the oriental medical treatments mainly have used strengthening body resistance of replenishing and strengthening cardioqi, dispersing stagnated hepatoqi, expelling cold and dehygrosis, invigorating stomach and nourishing qi.

  • PDF

Determination of Ascorbic Acid, Acetaminophen, and Caffeine in Urine, Blood Serum by Electrochemical Sensor Based on ZnO-Zn2SnO4-SnO2 Nanocomposite and Graphene

  • Nikpanje, Elham;Bahmaei, Manochehr;Sharif, Amirabdolah Mehrdad
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.173-187
    • /
    • 2021
  • In the present research, a simple electrochemical sensor based on a carbon paste electrode (CPE) modified with ZnO-Zn2SnO4-SnO2 and graphene (ZnO-Zn2SnO4-SnO2/Gr/CPE) was developed for the direct, simultaneous and individual electrochemical measurement of Acetaminophen (AC), Caffeine (Caf) and Ascorbic acid (AA). The synthesized nano-materials were investigated using scanning electron microscopy, X-ray Diffraction, Fourier-transform infrared spectroscopy, and electrochemical impedance spectroscopy techniques. Cyclic voltammetry and differential pulse voltammetry were applied for electrochemical investigation ZnO-Zn2SnO4-SnO2/Gr/CPE, and the impact of scan rate and the concentration of H+ on the electrode's responses were investigated. The voltammograms showed a linear relationship between the response of the electrode for individual oxidation of AA, AC and, Caf in the range of 0.021-120, 0.018-85.3, and 0.02-97.51 μM with the detection limit of 8.94, 6.66 and 7.09 nM (S/N = 3), respectively. Also, the amperometric technique was applied for the measuring of the target molecules in the range of 0.013-16, 0.008-12 and, 0.01-14 μM for AA, AC and, Caf with the detection limit of 6.28, 3.64 and 3.85 nM, respectively. Besides, the ZnO-Zn2SnO4-SnO2/Gr/CPE shows an excellent selectivity, stability, repeatability, and reproducibility for the determination of AA, AC and, Caf. Finally, the proposed sensor was successfully used to show the amount of AA, AC and, Caf in urine, blood serum samples with recoveries ranging between 95.8% and 104.06%.

The Effect of Dynamic Balance on Cyber Motion Sickness of Full Immersion Virtual Reality (완전 몰입형 가상현실로 인한 사이버 멀미가 동적 균형에 미치는 영향)

  • Kim, Na-Eun;Kim, Yu-lim;Moon, Sang-cheol;Lee, Dong-hung;Lim, Ho-jeong;Jang, Eun-kyung;Hung, Ji-eun;Kang, Jong-ho
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.1
    • /
    • pp.131-138
    • /
    • 2018
  • The purpose of the study was to explore whether the Cyber Motion sickness used VR causes a change in the dynamic balance and fall. For 39 people who voluntarily participated in this study, this study measured the motion sickness questionnaires, the heart rate and stability of limit test in BioRescue. The study used Samsung Gear VR and applied the games to the To the homeland. The game proceeded 20minutes. Although the value of the stability after a VR application is slightly reduced, it did not reach statistical significance. The motion sickness questionnaires increased, and it had a statistical significant impact. Also Heart rate increased and it had a statistically significant impact. A virtual reality game affect for getting motion sickness but it did not affect the dynamic balance. So, cyber motion sickness caused by virtual reality wear does not result in decreased balance and falls.

Feasibility of Ocean Survey by using Ocean Acoustic Tomography in southwestern part of the East Sea (동해 남서해역에서 해양음향 토모그래피 운용에 의한 해양탐사 가능성)

  • Han, Sang-Kyu;Na, Jung-Yul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.75-82
    • /
    • 1994
  • The ray paths and travel times of sound wave in the ocean depend on the physical properties of the propagating media. Ocean Acoustic Tomography(OAT), which is inversely estimate the travel time variations between fixed sources and receivers the physical properties of the corresponding media can he understood. To apply ocean survey technology by using the OAT, the tomographic procedure requires forward problem that variation of the travel times be identified with the variability of the medium. Also, received signals must be satisfied the necessary conditions of ray path stability, identification and resolution in order for OAT to work. The canonical ocean has been determined based on the historical data and its travel time and ray path are used as reference values. The sound speed of canonical ocean in the East Sea is about 1523 m/s at the surface and 1458 m/s at the sound channel axis(400m). Sound speeds in the East Sea are perturbed by warm eddy whose horizontal extension is more than 100 km with deeper than 200 m in depth scale. In this study, an acoustic source and receiver are placed at the depth above the sound channel axis, 350 m, and are separated by 200 km range. Ray paths are identified by the ray theory methed in a range dependent medium whose sound speeds are functions of a range and depth. The eigenray information obtained from interpolation between the rays bracketing the receiver are used to simulate the received signal by convolution of source signal with the eigenray informations. The source signal is taken as a 400 Hz rectangular pulse signal, bandwidth is 16 Hz and pulse length is 64 ms. According to the analysis of the received signal and identified ray path by using numerical model of underwater sound propagation, simulated signals satisfy the necessary conditions of OAT, applied in the East Sea.

  • PDF

Clinical Efficacy of Transdermal Clonidine (St 155 BS) for Anesthetic Management in Hypertensive Patients (고혈압 환자 마취시 Transdermal Clonidine (St 155 BS)의 임상적 유용성)

  • Lee, Hyun-Hwa;Kim, Dong-Ok;Kim, Keon-Sik;Choi, Young-Kyoo;Shin, Ok-Young;Kwon, Moo-Il;Lee, Doo-Ik
    • The Korean Journal of Pain
    • /
    • v.6 no.2
    • /
    • pp.231-236
    • /
    • 1993
  • Clonidine, a centrally-acting antihypertensive agent known to reduce central sympathetic outflow and modulate presynaptic transmitter's release, has shown to suppress central noradrenergic hyperactivity induced by immobilization stress in animals, by decreasing the MAC of halothane and the dose of narcotics required to prevent reflex cardiovascular response to noxious stimuli, and to have potent analgesic properties in humans. These characteristics suggest that clonidine might be a useful adjunct to the anesthetic management of patients with preexisting hypertension. Accordingly, we determined the clinical efficacy and safety on analgesia, sedation and hemodynamic stability in the perioperative period. Thirty patients(ASA physical status II-III) with a history of arterial hypertension, scheduled for elective orthopedic surgery were randomly assigned to two groups. We applied CPA-clonidine patch($6.9\;mg/cm^2$, 0.2 mg delivered daily) or placebo patch to each groups, 48 hours prior to induction of anesthesia. Antihypertensive medication was continued until the morning of the scheduled surgery. All patients received premedication of atropine and lorazepam, and induced anesthesia with thiopental and succinylcholine, and maintained with enflurane and 50% nitrous oxide, while sustaining the BP and pulse rate at acceptable range. For the relief of pain postoperatively, diclofenac and fentanyl were administered intramuscularly on demand. The results were as follows: 1) The change of hemodynamic responses in clonidine group was less compared to the placebo group. 2) Intraoperative anesthetic requirement for enflurane in clonidine group were significantly lower than placebo group. 3) Postoperative analgetic requirement in clonidine group were significantly lower than placebo group. In clonidine group, 5 cases out of 15 cases were required no analgetics, and the incidence of administration of additional fentanyl was decreased to 5 cases, comparing with 10 cases in placebo group.

  • PDF

Material Characteristics, Deterioration Evaluation and Crack Depth Estimation for Mulgyeseowon Stele in Changnyeong, Korea (창녕 물계서원 원정비의 재질특성 및 손상도 평가와 균열심도 측정)

  • Yoo, Ji Hyun;Lee, Chan Hee;Chun, Yu Gun
    • Journal of Conservation Science
    • /
    • v.30 no.4
    • /
    • pp.427-438
    • /
    • 2014
  • To measure the depth and extension on the surface cracks of the stone monument, ultrasonic pulse velocity targeted at the Mulgyeseowon Stele in Changnyeong was used in this research. Additionally, to establish a long-term countermeasure of management and conservation for this stele, we have investigated the material properties and damage on it and have conducted a precise diagnosis by a variety of non-destructive techniques. Our research has revealed that stones of the stele are composed mainly of three rock types according to the parts of it, alkali-feldspar granite, gabbro and diorite. The result of the deterioration evaluation has occurred that cracks, which are observed from every direction in the body of the stele, are the significant factors to reduce structural stability. The ultrasonic velocity for an evaluation on the properties of the stele has revealed that the speed was high in the order of body, pedestal and crown. Furthermore, to understand the present condition and occurrences of the cracks which have measured in many different forms on the stele quantitatively, we have estimated from 0.6 to 24.1cm deep of the cracks by To-Tc method using ultrasonic velocity.

The Effects of Singing Program Combined with Physical Exercise of Physiologic Changes, Perception Function and Degree of Depression in the Elderly Women (운동과 음악을 이용한 노래부르기가 노인의 생리적 변화, 인지기능 및 우울에 미치는 효과)

  • Jung, Young-Ju;Min, Soon
    • Journal of Korean Biological Nursing Science
    • /
    • v.3 no.2
    • /
    • pp.35-50
    • /
    • 2001
  • This study was conducted for the evaluation of the effects of singing program combined with physical exercise on the physiologic changes, perception function and degree of depression. The subjects were the members of elderly women's glee club in D care center for the elderly, who have been singing for more than 6 months. 30 members were allocated to study group and 30 to control group. The singing program designed for both physical therapy and music therapy was consisted of initial physical exercise, singing art songs and classical song and the finishing physical exercise. This program was performed twice a week and about forth minutes was consumed for one session. We checked the heart rate, peripheral arterial oxygen saturation, perception function and degree of depression before and after the program. We used a pulse oxymeter to check the heart rate to oxygen saturation and a questionnaire for the evaluation of perception function and degree of depression. We need SPSS program for data analysis. The results of the investigated personnel complying with general characteristics were analyzed by frequency, two groups by t-test, data before and after the program by paired t-test, respectively. The results were as follows. 1) Heart rate after the program was significantly lower than that before program in test group(p<0.05). 2) Peripheral oxygen saturation after the program was significantly higher than that before the program(p<0.05). 3) Ability to match the right sign with a certain predetermined number was improved after the program. The frequency of wrong matching the sign with number before program was 30. But the frequency was decreased to 8 after the program. 4) Ability to calculate was improved after the program. The frequency of wrong calculation before the program was $1.10{\pm}1.94$. But the frequency after the program was decreased to $0.97{\pm}1.84$. 5) The degree of depression after the program($2.07{\pm}0.49$) was significantly lower than that before program(p<0.001). These results show that singing program combined with physical exercise improves the oxygen delivery to peripheral circulation, stability of heart function, the perception function(calculating and matching ability) and decreases the degree of depression. In conclusion, singing program combined with physical exercise can be used for the effective measure to improve the health of elderly and prevent dementia.

  • PDF

Flash Lamp Annealing of Ag Organometallic Ink for High-Performance Flexible Electrode (플래시 기반 유기금속화합물 열처리를 통한 고성능 유연 전극 제조)

  • Yu Mi Woo;Dong Gyu Lee;Yun Sik Hwang;Jae Chan Heo;SeongMin Jeong;Yong Jun Cho;Kwi-Il Park;Jung Hwan Park
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.5
    • /
    • pp.454-462
    • /
    • 2023
  • Flash lamp annealing (FLA) of metal nanoparticle (NP) ink has provided powerful strategies to fabricate high-performance electrodes on a flexible substrate because of its rapid processing capability (in milliseconds), low-temperature process, and compatibility with to roll-to-roll process. However, metal NPs [e.g., gold (Au), silver (Ag), copper (Cu), etc.] have limitations such as difficulty in synthesizing fine metal NPs (diameter less than 10 nm), high price, and degradation during ink storage and FLA processing. In this regard, organometallic ink has been proposed as a material that can replace metal NPs due to their low-cost (usually 1/100 times cheaper than metal nano inks), low-temperature processability, and high material stability. Despite these advantages, the fabrication of flexible electrodes through FLA treatment of organometallic compounds has not been extensively researched. In this paper, we experimentally guide how to determine the optimal conditions for forming electrodes on flexible substrates by considering material parameters, and flashlight processing parameters (energy density, pulse duration, etc) to minimize the difficulties that may arise during the FLA of organometallic ink.

INVESTIGATION OF RUNNING BEHAVIORS OF AN LPG SI ENGINE WITH OXYGEN-ENRICHED AIR DURING START/WARM-UP AND HOT IDLING

  • Xiao, G.;Qiao, X.;Li, G.;Huang, Z.;Li, L.
    • International Journal of Automotive Technology
    • /
    • v.8 no.4
    • /
    • pp.437-444
    • /
    • 2007
  • This paper experimentally investigates the effects of oxygen-enriched air (OEA) on the running behaviors of an LPG SI engine during both start/warm-up (SW) and hot idling (HI) stages. The experiments were performed on an air-cooled, single-cylinder, 4-stroke, LPG SI engine with an electronic fuel injection system and an electrically-heated oxygen sensor. OEA containing 23% and 25% oxygen (by volume) was supplied for the experiments. The throttle position was fixed at that of idle condition. A fueling strategy was used as following: the fuel injection pulse width (FIPW) in the first cycle of injection was set 5.05 ms, and 2.6 ms in the subsequent cycles till the achieving of closed-loop control. In closed-loop mode, the FIPW was adjusted by the ECU in terms of the oxygen sensor feedback. Instantaneous engine speed, cylinder pressure, engine-out time-resolved HC, CO and NOx emissions and excess air coefficient (EAC) were measured and compared to the intake air baseline (ambient air, 21% oxygen). The results show that during SW stage, with the increase in the oxygen concentration in the intake air, the EAC of the mixture is much closer to the stoichiometric one and more oxygen is made available for oxidation, which results in evidently-improved combustion. The ignition in the first firing cycle starts earlier and peak pressure and maximum heat release rate both notably increase. The maximum engine speed is elevated and HC and CO emissions are reduced considerably. The percent reductions in HC emissions are about 48% and 68% in CO emissions about 52% and 78%; with 23% and 25% OEA, respectively, compared to ambient air. During HI stage, with OEA, the fuel amount per cycle increases due to closed-loop control, the engine speed rises, and speed stability is improved. The HC emissions notably decrease: about 60% and 80% with 23% and 25% OEA, respectively, compared to ambient air. The CO emissions remain at the same low level as with ambient air. During both SW and HI stages, intake air oxygen enrichment causes the delay of spark timing and the increased NOx emissions.