• Title/Summary/Keyword: Pulse Sampling

Search Result 139, Processing Time 0.024 seconds

A real-time sorting algorithm for in-beam PET of heavy-ion cancer therapy device

  • Ke, Lingyun;Yan, Junwei;Chen, Jinda;Wang, Changxin;Zhang, Xiuling;Du, Chengming;Hu, Minchi;Yang, Zuoqiao;Xu, Jiapeng;Qian, Yi;She, Qianshun;Yang, Haibo;Zhao, Hongyun;Pu, Tianlei;Pei, Changxu;Su, Hong;Kong, Jie
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3406-3412
    • /
    • 2021
  • A real-time digital time-stamp sorting algorithm used in the In-Beam positron emission tomography (In-Beam PET) is presented. The algorithm is operated in the field programmable gate array (FPGA) and a small amount of registers, MUX and memory cells are used. It is developed for sorting the data of annihilation event from front-end circuits, so as to identify the coincidence events efficiently in a large amount of data. In the In-Beam PET, each annihilation event is detected by the detector array and digitized by the analog to digital converter (ADC) in Data Acquisition Unit (DAQU), with a resolution of 14 bits and sampling rate of 50 MS/s. Test and preliminary operation have been implemented, it can perform a sorting operation under the event count rate up to 1 MHz per channel, and support four channels in total, count rate up to 4 MHz. The performance of this algorithm has been verified by pulse generator and 22Na radiation source, which can sort the events with chaotic order into chronological order completely. The application of this algorithm provides not only an efficient solution for selection of coincidence events, but also a design of electronic circuit with a small-scale structure.

Preliminary Study on Rapid Measurement of Gross Alpha/Beta and 90Sr Activities in Surface Soil by Mobile ZnS(Ag)/PTV Array and Handheld PVT Rod with Gated Energy Channels

  • Lee, Chanki;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.194-203
    • /
    • 2021
  • Background: Surface soil radiation monitoring around nuclear facilities is important to classify and characterize the contaminated areas. A scanning and direct measurement technique can survey the sites rapidly before starting sampling analysis. Materials and Methods: Regarding this, we test and suggest a measurement technique for gross alpha/beta and 90Sr activities in surface soil based on a mobile ZnS(Ag)/PVT (polyvinyltoluene) array and a handheld PVT rod, respectively. To detect 90Sr selectively in soil mixed with naturally occurring radioactive materials, chosen energy channel counts from the multichannel analyzers were used instead of whole channel counts. Soil samples contaminated with exempt liquid 90Sr with 1 Bq·g-1, 3 Bq·g-1, and 10 Bq·g-1 were prepared and hardened by flocculation. Results and Discussion: The mobile ZnS(Ag)/PVT array could discriminate gross alpha, gross beta, and gamma radiation by the different pulse-shaped signal features of each sensor material. If the array is deployed on a vehicle, the scan minimum detectable concentration (MDC) range will be about 0.11-0.17 Bq·g-1 at 18 km·h-1 speed, highly sensitive to actual sites. The handheld PVT rod with 12 mm (Φ) × 20 mm (H) size can directly measure 90Sr selectively if channels on which energies are from 1,470 and 2,279 keV are gated, minimizing crossdetection of other radionuclides. These methods were verified by measuring soil samples fabricated with homogeneous 90Sr concentrations, showing static MDC of 2.16 Bq·g-1 at a measurement time of 300 seconds. Conclusion: Based on the results, comprehensive procedures using these detectors are suggested to optimize soil sites survey.

Block-Based Transform-Domain Measurement Coding for Compressive Sensing of Images (영상 압축센싱을 위한 블록기반 변환영역 측정 부호화)

  • Nguyen, Quang Hong;Nguyen, Viet Anh;Trinh, Chien Van;Dinh, Khanh Quoc;Park, Younghyeon;Jeon, Byeungwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.12
    • /
    • pp.746-755
    • /
    • 2014
  • Compressive sensing (CS) has drawn much interest as a new sampling technique that enables signals to be sampled at a much lower than the Nyquist rate. By noting that the block-based compressive sensing can still keep spatial correlation in measurement domain, in this paper, we propose a novel encoding technique for measurement data obtained in the block-based CS of natural image. We apply discrete wavelet transform (DWT) to decorrelate CS measurements and then assign a proper quantization scheme to those DWT coefficients. Thus, redundancy of CS measurements and bitrate of system are reduced remarkably. Experimental results show improvements in rate-distortion performance by the proposed method against two existing methods of scalar quantization (SQ) and differential pulse-code modulation (DPCM). In the best case, the proposed method gains up to 4 dB, 0.9 dB, and 2.5 dB compared with the Block-based CS-Smoothed Projected Landweber plus SQ, Block-based CS-Smoothed Projected Landweber plus DPCM, and Multihypothesis Block-based CS-Smoothed Projected Landweber plus DPCM, respectively.

An I/O Interface Circuit Using CTR Code to Reduce Number of I/O Pins (CTR 코드를 사용한 I/O 핀 수를 감소 시킬 수 있는 인터페이스 회로)

  • Kim, Jun-Bae;Kwon, Oh-Kyong
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.47-56
    • /
    • 1999
  • As the density of logic gates of VLSI chips has rapidly increased, more number of I/O pins has been required. This results in bigger package size and higher packager cost. The package cost is higher than the cost of bare chips for high I/O count VLSI chips. As the density of logic gates increases, the reduction method of the number of I/O pins for a given complexity of logic gates is required. In this paper, we propose the novel I/O interface circuit using CTR (Constant-Transition-Rate) code to reduce 50% of the number of I/O pins. The rising and falling edges of the symbol pulse of CTR codes contain 2-bit digital data, respectively. Since each symbol of the proposed CTR codes contains 4-bit digital data, the symbol rate can be reduced by the factor of 2 compared with the conventional I/O interface circuit. Also, the simultaneous switching noise(SSN) can be reduced because the transition rate is constant and the transition point of the symbols is widely distributed. The channel encoder is implemented only logic circuits and the circuit of the channel decoder is designed using the over-sampling method. The proper operation of the designed I/O interface circuit was verified using. HSPICE simulation with 0.6 m CMOS SPICE parameters. The simulation results indicate that the data transmission rate of the proposed circuit using 0.6 m CMOS technology is more than 200 Mbps/pin. We implemented the proposed circuit using Altera's FPGA and confimed the operation with the data transfer rate of 22.5 Mbps/pin.

  • PDF

A Study for 8 Constitution Medicine Diagnosis Expert System Development(2) (8체질 진단을 위한 전문가 시스템 개발에 관한 연구(2))

  • Shin, Yong-Sup;Park, Young-Bae;Park, Young-Jae;Kim, Min-Yong;Lee, Sang-Chul;Oh, Hwan-Sup
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.2
    • /
    • pp.107-126
    • /
    • 2008
  • Background : There was seldom study about method that diagnose 8 Constitution beside method of pulse diagnosis in 8 Constitution Medicine. Objectives : This study is to make out 8 Constitution Medicine Diagnosis Expert System Development used CBR(Case based Reasoning). Methods : First, at case base construction process we constructed case base for CBR embodiment because gathering 925 cases all to patient who constitution is verified, and second, at study model establishment process superior expert system development by purpose CBR of reasoning process dividing fundamental type CBR that spend basis data value and expert type CBR that reflect weight in basis data value accordin I II III to advice expert opinion, and third, system embodiment process explained about way to give process and weight that diagnose constitution through Nearest Neighbor Method sampling process of CBR techniques, and fourth, at system estimation process we selected superior CBR model because comparing and estimate the diagnosis rate of expert system with fundamental type system (GECBR) model and expert type I II III CBR system (AVCBR, AACBR, AGCBR) model that reflect expert opinion in fundamental type system. GECBR and AGCBR chose on superior study model. Through such 4 study process, we developed 8 constitution diagnosis expert system lastly. Results : 1. When we select GECBR that is fundamental type by reasoning system, diagnosis rate 78.91% of 8 constitution diagnosis expert system is expected, and the constitution diagnosis rate Hepatonia 90.4%, Cholecystonia 63.0%, Pancreotonia 91.1%, Gastrotonia 0%, Pulmotonia 71.2%, Colonotonia 74.4%, Renotonia 37.5%, Vesicotonia 67.1% expect. 2. When we select AGCBR that is expert type III by reasoning system, diagnosis rate 77.51% of 8 constitution diagnosis expert system is expected, and the constitution diagnosis rate Hepatonia 93.4%, Cholecystonia 58.5%, Pancreotonia 91.1%, Gastrotonia 0%, Pulmotonia 73.1%, Colonotonia 64.4%, Renotonia 41.7%, Vesicotonia 72.2% expect. Conclusion : Based on this study, 8 constitution diagnosis expert system may give help to diagnose 8 constitution, and it is going to utilize as objective estimation tool of 8 constitution diagnosis, and further study for 8 Constitution Medicine Diagnosis Expert System Development used CBR(Case based Reasoning) is needed to supplement this study.

  • PDF

Experimental Evaluation of an Analytical Method for Chlorofluorocarbons (CFSs) in Air and Water Using Gas Chromatography (가스 크로마토그래피를 이용한 대기와 물시료의 CFCs(chlorofluorocarbons) 분석법의 실험적 평가)

  • Koh, Dong-Chan;Choi, Beom-Kyu;Kim, Yong-Je
    • Economic and Environmental Geology
    • /
    • v.40 no.1 s.182
    • /
    • pp.129-140
    • /
    • 2007
  • CFC(CFC-12, CFC-11 and CFC-113) analytical system for air and water was constructed using a customized purge and trap extraction device and a gas chromatograph with an electron capture detector. Sampling methods of air and water for CFCs were also established. The analytical system was experimentally optimized to result in reproducibilities of triplicates less than 2% for current air samples and less than 5% for groundwater samples with CFC-12 concentration of 160 to 180 pg/kg, and verified with respect to the CFC system in USGS, which showed analytical results were in agreement within 10%. CFCs in air were monitored at three sites over 19-month period in the central part of South Korea, and the result indicates no significant local sources of CFCs in those areas. For groundwater in Jeju Island, CFCs were measured over a year with a two-month interval. The time-series data showed seasonal fluctuations which could be interpreted by the effect of recharge pulse derived from large amount of rainfall during monsoon period with a few month delay, which indicates high permeability of basaltic rocks in Jeju Island.

Study of Cross Correlation Using DRS(Delayed Reference Sample) for Precision Time Measurement of Input Signal on Multilateration (다변측정감시시스템 신호 입력 시각 정밀 측정을 위한 DRS(Delayed Reference Sample)를 이용한 Cross Correlation 방안 연구)

  • Chang, Jae-Won;Lee, Sang Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.3
    • /
    • pp.244-250
    • /
    • 2018
  • Multilateration acquires the transponder signal of target from receivers installed on the ground and calculates the position of the target using the difference of the signal acquisition time of each receiver. One of the factors that influence the positioning accuracy of Multilateration using the TDOA calculation method is the error due to the precision measurement of signal input time. When measuring the signal input time at the receiver, the input signal is sampled using the reference clock of the receiver and a reference sample having the same sampling rate is applied to the cross correlation technique. Therefore, the accuracy of the signal input time is proportional to the reference clock. In this paper, the algorithm for precisely measuring the signal input time by performing cross correlation between the input signal of the receiver and DRS(Delayed Reference Sample) is proposed. In order to verify this, we implemented the pulse signal of the transponder that is transmitted from the target using Matlab. Through the simulation, cross correlation between the proposed DRS and the input signal was performed. From this result, the performance of the precise measurement of signal input time was analyzed.

A Study for 8 Constitution Medicine Diagnosis Expert System Development (8체질의학을 위한 진단 전문가 시스템 개발 및 고찰)

  • Shin, Yong-Sup;Park, Young-Bae;Park, Young-Jae;Kim, Min-Yong;Oh, Hwan-Sup
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.142-184
    • /
    • 2008
  • Background: There was seldom study about method that diagnose 8 Constitution beside method of pulse diagnosis in 8 Constitution Medicine. Objectives: This study is to make out 8 Constitution Medicine Diagnosis Expert System Development used CBR(Case based Reasoning). Methods: First, at case base construction process we constructed case base for CBR embodiment because gathering 925 cases all to patient who constitution is verified, and second, at study model establishment process superior expert system development by purpose CBR of reasoning process dividing fundamental type CBR that spend basis data value and expert type I II III CBR that reflect weight in basis data value according to advice expert opinion, and third, system embodiment process explained about way to give process and weight that diagnose constitution through Nearest Neighbor Method sampling process of CBR techniques, and fourth, at system estimation process we selected superior CBR model because comparing and estimate the diagnosis rate of expert system with fundamental type system (GECBR) model and expert type I II III CBR system (AVCBR, AACBR, AGCBR) model that reflect expert opinion in fundamental type system. GECBR and AGCBR chose on superior study model. Through such 4 study process, we developed 8 constitution diagnosis expert system lastly. Results: 1. When we select GECBR that is fundamental type by reasoning system, diagnosis rate 78.91% of 8 constitution diagnosis expert system is expected, and the constitution diagnosis rate Hepatonia 90.4%, Cholecystonia 63.0%, Pancreotonia 91.1%, Gastrotonia 0%, Pulmotonia 71.2%, Colonotonia 74.4%, Renotonia 37.5%, Vesicotonia 67.1% expect. 2. When we select AGCBR that is expert type III by reasoning system, diagnosis rate 77.51% of 8 constitution diagnosis expert system is expected, and the constitution diagnosis rate Hepatonia 93.4%, Cholecystonia 58.5%, Pancreotonia 91.1%, Gastrotonia 0%, Pulmotonia 73.1%, Colonotonia 64.4%, Renotonia 41.7%, Vesicotonia 72.2% expect. Conclusion: Based on this study, 8 constitution diagnosis expert system may give help to diagnose 8 constitution, and it is going to utilize as objective estimation tool of 8 constitution diagnosis, and further study for 8 Constitution Medicine Diagnosis Expert System Development used CBR(Case based Reasoning) is needed to supplement this study.

  • PDF

The Effect of Aerobic Exercise on Body Composition, Cardiopulmonary Function, Serum Lipid and Antioxidants of Obese College Female Students (에어로빅운동이 비만여대생의 신체조성, 심폐기능, 혈청지질 및 항산화물질에 미치는 영향)

  • Jung Eun-Sook;Park Hyeong-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.1
    • /
    • pp.125-141
    • /
    • 1998
  • The purpose of this research is to analyze the effects of aerobic exercise on body composition, cardiopulmonary function, serum lipid level and antioxidants of obese and normal college female students. The subject group was made up of 13 normal students (below 30% body fat ratio) and 12 obese students (above 30% body fat ratio). After a pretest, the subjects were given an 8-week aerobic program. Then the subjects were given a posttest and analyzed of body composition, serum lipid level, antioxidants and cardiopulmonary function after the 6th and the 8th week of the program. The program schedule was made up of 4 days per week, 60 minutes per day. Test includes B.W., subscapular and triceps subcutaneous fat thickness, change of respiratory gas, and two blood sampling before treadmill exercise and post all out state, which analyzed serum lipid and antioxidants. The subjects performed treadmill exercise starting with 4km/hr of walking and then gradually increase the speed of 1km/hr per minute until all out state. The obtained data were analyzed using SAS program. The statistical methods employed here were one-way ANOVA with repeated measure, Duncan Multiple range test, paired-t test and t-test. The test results and conclusion of this research were as follows. 1. The effects of aerobic exercise on body composition were as follows ; Percent body fat was significantly reduced 6 weeks after the program and lean body mass was significantly increased 8 weeks after the program in both groups(obese group: F=3.44 P=.044, normal group: F=3.30 P=.048). subscapular skinfold of the obese group showed a remarkable decrease after the 6th week(F=4.33 P=.021) triceps skinfold of the normal group showed a remarkable decrease after the 6th and the 8th week(F=4.55 P=.017) compared with readings before the aerobic program, the aerobic program made a bigger difference concerning body fat, lean body mass, subscapular skinfold in the obese group than in the normal group(t=2.41 P=.024, t=2.40 p=.025, t=2.43 p=.028). 2. The effects of aerobic exercise on cardiopulmonary function were as follows ; Maximal $O_2$ uptake/kg was significantly increased 6 weeks after the program in the obese group(F=3.20 P=.054), but not much difference was observed in the normal group. Maximal pulse rate was significantly reduced in both groups after 6 weeks of the program(obese group: F=2.77 P=.087, normal group: F=7.17 P=.001). 3. The effects of aerobic exercise on serum lipid level were as follows ; In a resting period, total cholesterol, Triglyceride, and LDL-cholesterol were slightly higher in the obese group than in the normal group, but HDL-cholesterol was higher in the normal group. But, with the aerobic program, total-cholesterol, Triglyceride, LDL-cholesterol were reduced gradually and HDL-choleterol got increased in both groups, but not much change was noticed in the normal group. However, in the obese group, serum HDL-cholesterol level got increased significantly(F=5.12 P=.012). 4. The effects of aerobic exercise in serum antioxidants were as follows ; In a resting period, the obese group's serum Free Radical and GSSG content were higher than the normal group's and the normal group's serum GSH content was higher than the obese group's. After 6 weeks of the aerobic program, Free Radical was reduced significantly in both groups(obese group: F=13.87 P=.000, normal group: F=18.60 P=.000) In the obese group, 8 weeks after the program, GSH was increased significantly(F=13.78, P=.000). In the normal group, 6 weeks after the program, GSH was reduced but increased again after 8 weeks(F=6.07 P=.005). Plasma GSSG was significantly increased after 8 weeks of exercise in both groups(obese group: F=19.75 P=.000, normal group: F=22.42 P=.000,) Compared with readings before the aerobic program, the aerobic program made a bigger difference serum GSH in the normal group than in the obese group(t=3.37 p=.003). As this result shows, it is known that the regular aerobic exercise improves cardiopulmonary function, body composition, serum lipid effectively and through the serum Free Radical reduction and antioxidant system activation, oxidant stress was suppressed. This effect was higher in the obese group than in the normal one. At least 6weeks exercise period need for improvement of body composition, cardiopulmonary function and activation of antioxidant system. This result suggest that improvement of serum lipid profile was needed longer than 8weeks exercise period.

  • PDF