• Title/Summary/Keyword: Pulse Load

Search Result 530, Processing Time 0.028 seconds

The influence of load pulse shape on pressure-impulse diagrams of one-way RC slabs

  • Wang, Wei;Zhang, Duo;Lu, Fangyun
    • Structural Engineering and Mechanics
    • /
    • v.42 no.3
    • /
    • pp.363-381
    • /
    • 2012
  • This study is aimed at providing an efficient analytical model to obtain pressure- impulse diagram of one-way reinforced concrete slabs subjected to different shapes of air blast loading using single degree of freedom method (SDOF). A tri-linear elastic perfectly plastic SDOF model has been used to obtain the pressure-impulse diagram to correlate the blast pressure and the corresponding concrete flexural damage. In order to capture the response history for the slab, a new approximately SDOF method based on the conventional SDOF method is proposed and validated using published test data. The influences of pulse loading shape on the pressure-impulse diagram are studied. Based on the results, a pressure-impulse diagram generation method using SDOF and an analytical equation for the pressure-impulse diagram is proposed to different damage levels and different blast loading shapes.

A New High Efficiency Half Bridge Converter with Improved ZVS Performance

  • Lee Sung-Sae;Han Sang-Kyoo;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.187-194
    • /
    • 2006
  • A new asymmetrical pulse width modulation (PWM) half bridge converter with improved ZVS performance is proposed. The ZVS operation of the proposed converter can be maintained from no load to full load conditions since the magnetizing current of the transformer contributes to the ZVS operation at light loads without considerable conduction loss of the transformer and switch. Synchronous rectification is employed to reduce the rectification loss. Operational principles, large signal modeling, ZVS analysis and design equations are presented. Experimental results demonstrate that the proposed converter can achieve a large ZVS range and significant improvement in efficiency for a 100W (5V, 20A) prototype converter.

On the Analysis of Dynamic Characteristics of Pipe Supporting Hydraulic Snubber in Electric Power Plant with State-space Model and Impulse Testing (상태공간 모델과 임펄스 시험에 의한 발전소 배관지지용 유압완충기의 동특성 해석)

  • Lee, Jae-Cheon;Hwang, Tae-Yeong
    • 연구논문집
    • /
    • s.31
    • /
    • pp.89-99
    • /
    • 2001
  • This paper presents the modeling and analysis of dynamic characteristics of hydraulic snubber in electric power plant. The nonlinear state-space model of 14th order to describe the dynamics of the snubber was established by Simulink. The simulation results show that the hydraulic snubber reacts as like the conventional shock absolvers against the high pulse shock load. The snubber also shows the peculiar characteristics to the small step load, which temporarily lock the control valves up, however maintain same steady-state pressures of all internal chambers in the long run. Two case studies for the analysis of the snubber are addressed. Practical pulse testing method was also proposed to identify the frequency response of the snubber.

  • PDF

Rapid Dynamic Response Flyback AC-DC Converter Design

  • Chang, Changyuan;Wu, Menglin;He, Luyang;Zhao, Dadi
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1627-1633
    • /
    • 2018
  • A constant voltage AC-DC converter based on digital assistant technology is proposed in this paper, which has rapid dynamic response capability. The converter operates in the PFM (Pulse Frequency Modulation) mode. According to the load state, the compensation current produced by the digital compensation module was injected into the CS pin to adjust the switching pulse width dynamically and improve the dynamic response. The control chip is implemented based on NEC $1{\mu}m$ 5V/40V HVCMOS process. A 5V/1.2A prototype has been built to verify the proposed control method. When the load jumps from idle to heavy, the undershoot time is only 7.4ms.

Analysis for Light Load Regulation of LLC Converter using Bode Plot (보드 선도를 이용한 LLC 컨버터의 경 부하 레귤레이션 특징 분석)

  • Yeon, Cheol-O;Moon, Gun-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.506-513
    • /
    • 2016
  • In general, LLC converters show great promise in applications that require high efficiency, especially under light load conditions. In particular, LLC converters feature wide gain capability with pulse-frequency modulation and zero voltage switching over entire load conditions. However, output voltage increases in light load conditions. In this study, Bode plot and impedance asymptotes analyses were conducted to obtain insights into the regulation characteristics of LLC converters under light load conditions. To improve the regulation characteristic of LLC converters, a new resonant tank with an additional capacitor is proposed. The design guideline for the proposed LLC converter is determined by the Bode plot and impedance asymptotes analyses. Therefore, the proposed LLC converter achieves the light load regulation while maintaining the advantages of typical LLC converters.

An effects of the Pulse Distortion due to Dispersion and Reflection on Tapered Microstrip Line (데이퍼형 마이크로 스트립 선로에서 분산과 반사가 펄스의 왜곡에 미치는 영향)

  • 김기래
    • Proceedings of the IEEK Conference
    • /
    • 2000.06a
    • /
    • pp.271-274
    • /
    • 2000
  • In this paper, the distortion of an electrical pulse with rise/fall time resulting from dispersion and reflection as it propagates along a tapered microstrip line is investigated, and the delay time and distortion rate with respect to input and load impedances are analyzed on triangular and exponential tapered lines and analyzed the influence of the reflection and frequency dispersion on the distorted voltage wave in the tapered lines. The observed overshoot in front of the distorted wave is caused due to the frequency dispersion and the sustained tail of that comes from the reflection in the tapered line.

  • PDF

A High-power Voltage Mode Buck Converter IC for Automotive Applications (자동차용 고출력 전압모드 벅컨버터 IC)

  • Park, Hyeon-Il;Park, Shi-Hong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.7
    • /
    • pp.555-558
    • /
    • 2009
  • This paper presents a step-down converter IC for automotive applications. This device was designed for a 40 V/1 A high-power output for voltage reference of automotive IC. It provides 250kHz PWM (pulse width modulation) and PFM(pulse frequency modulation) according to load conditions. This device was simulated spectre of IC-design-tools and fabricated Dong-bu Hitec 0.35um BD350BA process.

Optimum Design Study on 0.5 MJ-Class Superconducting Pulse Magnet (0.5MJ 초전도 펄스 마그네트의 최적화 설계에 관한 연구)

  • 노완수;한송엽;황석영;이승원;홍원표
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.8
    • /
    • pp.813-819
    • /
    • 1990
  • In this paper, a new design method for superconducting pulse magnet is presented. Given energy storage capacity, magnet shape parameters are determined to minimize superconducting material quantity. Once the shape parameters are determined, cooling channel is designed and degradation characteristics are confirmed. According to the proposed magnet design concept, relatively uniform and low field distribution is obtained. Therefore, both the quantity of superconducting material and the mechanical load over magnet are reduced.

  • PDF

Measurement of workload by cardiac arrhythmia (부정맥을 이용한 작업부하의 평가)

  • 박영택;박경수
    • Journal of the Ergonomics Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.3-10
    • /
    • 1983
  • While three subjects were running on treadmill at five different speeds, their heart beat interval times were measured and analyzed. From the analysis, we discovered some relation- ships between workload and cardiac response, especially cardiac arrhythmia. Using these relationships, a physioligical model for estimating workload was developed. Although pulse rate has been considered as a good measure of physical load, this study shows that it is highly subject dependent and therefore unsuitable for task evalution. It is recommended to use range of heart beat interval times rather than pulse rate in the evaluation of light work.

  • PDF

Analysis of Protection Circuits of Overcurent and Overvoltage on Transmission Line Induced by External Electromagnetic Pulse (외부 전자파 펄스에 의해 전송선로에 유기되는 과전류 및 과전압 보호회로의 해석)

  • 하헌태;김세윤;이경재;오명환
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.1
    • /
    • pp.8-14
    • /
    • 1991
  • A new algorithm for calculation of overcurrent and overvoltage at load for parallel two-wire transmission line with nonlinear protection circuits induced by and external electromagnetic pulse is suggested. The rigorous solution is obtained for a particular type of the incident waveform and protection circuit. The validity of our algorithm is checked by comparing numerical results to the analytic solution in the particular case.

  • PDF