Echolocation Signals of Pipistrellus abramus in Relation to Environmental Type (환경특성에 따른 집박쥐의 반향정위(Echolocation) 시그널 분석)

  • Chung, Chul-Un;Han, Sang-Hoon;Kim, Sung-Chul;Lee, Chong-Il
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.6
    • /
    • pp.553-563
    • /
    • 2009
  • This study was conducted to analyze the changes in the echolocation of Pipistrellus abramus according to environmental characteristics. The survey was conducted in the day-roosting site of P. abramus located in Gyeongju City (North Gyeongsang Province) from April to August, 2009. The environmental characteristics during the research were classified in six categories: the emergence time after sunset moving time from day roost to feeding areas; rice fields; forest edges; open spaces; and residential areas. Analysis results showed that there are differences in environmental characteristics and also differences between the moving time to the habitat and the moving time to capture preys. At the emergence time from day roost, Pipistrellus abramus used a FM signal with a short pulse-duration. In open spaces, however, they used a CF signal with a long pulse-duration. In different environmental situations, they used both FM and CF signals, although the types of pulse which they used were different. Except pulse-duration, there were significant differences in pulse-interval, peak-frequency, starting-frequency and ending-frequency between the movement among habitats and the movement to capture preys. Except the emergence time from day-roost, they showed a narrow band FM signal and a long pulse-duration that are suitable to search for insects by sensing echoes of insects when they moved among their habitats. When they were out to capture their preys, they showed a broad band FM signal and a short pulse-duration which enabled them to widely search and accurately locate their preys.

An Algorithm for De-Interleaving of Wobble and Sinusoidal PRIs for Unidentified Radar Signals (미상 레이더의 Wobble 및 Sinusoidal PRI 식별 알고리즘)

  • Lee, Yongsik;Lim, Joongsoo;Lim, Jaesung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.12
    • /
    • pp.1100-1107
    • /
    • 2015
  • In this paper, we propose an algorithm to identify Wobble PRI and Sinusoidal PRI among Radar pulses. We applied not only the DTOA(Difference Time Of Arrival) concept of radar pulse signals incoming to antennas but also a rising and falling cub characteristic of those PRIs. After making a program by such algorithm, we input each 40 data to Wobble PRI's and Sinusoidal PRI's identification programs and in result, those programs fully processed the data the according to expectations. In the future, those programs can be applied to the ESM, ELINT system.

Measurement of Cardiac Pulse Transit Time using Photoplethysmography Sensor (광전용적맥파 센서를 이용한 맥파전달시간의 측정)

  • Choi, Byeong-Cheol;Jung, Dong-Keun;Jeong, Do-Un;Ro, Jung-Hun;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.383-391
    • /
    • 2004
  • In this study, we implemented the pulse transit time (PTT) system to examine usefulness of the monitoring method of distensibility and elasticity using photoplethysmography sensor in vivo. PTT is defined as the time interval between the peak of QRS complex in ECG signal and the maximum slope point of photoplethysmography. these two signals were converted to digital data by means of AID converter, then PTT was evaluated by heartbeat using PC. Results of analysis were displayed as a graph using spline interpolation method. The variance of PTT was measured repetitiously to verify efficiency of PTT system in resting state and hyperemic state. Repeated measurement of PTT was not same value but showed that coefficients of correlation were related with each other as 0.8302 (P<0.01) in resting state. And also repeated measurement of PTT showed significant correlation as 0.868 (P<0.01) in the hyperemic state. These result showed that PTT is reflect on transient pressure variance in the artery and is very useful method for the evaluation of prognosis of the hypertension and arteriosclerosis.

On Study of Pulse Wave Signal According to Postural Change Using Finger Plethysmography (손가락 끝 용적맥파를 이용한 자세변화에 따른 맥파 신호에 관한 연구)

  • Choi, B.C.;Kim, C.H.;Jung, D.K.;Suh, D.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.125-126
    • /
    • 1998
  • Pulse conduction velocity is determined by areterial compliance, which is changed by lateral pressure of arterial wall. Hydrostatic pressure of the limb vessel is changed by body position, especially in elevated arm. The arterial pulse in the finger causes the blood volume to change, changing the optical density of the blood. Photoplethysmograph of index finger was obtained by LED and phototransistor. Pulse transmission time(PTT) was measured by the interval between the peak of ECG R wave and the peak of the finger plethysmogram. PTT was increased by upward position of arm, and decreased by downward position of the arm compared to horizontal position. This result suggests that relationship between finger plethysmography and postural change could be applied to evaluate clinical cardiovascular status.

  • PDF

Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields (균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성)

  • Kim, Tae-Ki;Kim, Seung-Min;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.

A method for setting coherent processing interval of continuous active sonar based on correlation of GSFM pulse (GSFM 펄스의 상관도에 기반한 연속 송수신 소나의 신호처리 구간 설정 방법)

  • Kim, Hyeon-su;Kim, Hyun-woo;Lee, Won-oh;Park, Song-hwa;Lee, Jung-hoon;Park, Gyu-tae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.5
    • /
    • pp.401-407
    • /
    • 2021
  • The continuous active sonar technology is effective for detecting and tracking targets because of short target revisiting rate. Generalized Sinusoidal Frequency Modulation (GSFM) pulses suitable for continuous active sonar systems are known to be capable of obtaining high time-bandwidth product while maintaining the orthogonality between pulses. However, it is unknown how to calculate an appropriate length of time to correlate received GSFM pulses in the presence of a target with acceleration. In this paper, we propose a method to calculate the appropriate time length based on the correlation when matching the received signal in the continuous active sonar system using GSFM pulse. The proposed method calculates the correlation according to the acceleration of the target and calculates the signal processing length according to the correlation. It is shown that stable detection performance can be obtained when the signal processing length calculated by the proposed method through the level of the sidelobe is applied.

The Tire Damage Classification by Pulse Interval Time Density Function of Ultrasonic Wave Envelope on Driving (주행 중 타이어 손상에 의해 발생하는 초음파 포락선 신호의 펄스 간격 시간밀도함수에 의한 손상 분별)

  • Shin, Seong-Geun;Kang, Dae-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.3
    • /
    • pp.41-46
    • /
    • 2011
  • The tire damage classification method is researched by periodicity detection of ultrasonic envelope signals to occur at the driving vehicle tire. Because periodic signals is generated by rotations of the damaged tire, it should convert to pulse for using the density function. After time intervals of pulses are represented by the density function, the dominant periodicity is detected. The threshold to make a pulse is calculated by moving average of envelope signals. The result of time density function in case of one damage material, the first peak's time is equals to tire's rotation period, 162ms and 102ms, about the speed of 50km/h and 80km/h. In case of more than one damage material, the sum of each peak's time is equals to tire's rotation period about the speed.

Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors (PPG 및 ECG 센서를 이용한 혈압추정 기법 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1257-1264
    • /
    • 2019
  • The traditional cuff-based method for BP(Blood Pressure) measurement is not suitable for continuous real-time BP measurement techniques. For this reason, the previous studies estimated various blood pressures by fusion with the electrocardiography (ECG) and photoplethysmogram (PPG) sensor signals. However, conventional techniques based on PPG bio-sensing measurement face many challenging issues such as noisy supply fluctuation, small pulsation, and drifting non-pulsatile. This paper proposed a novel BP estimation methods using PPG and ECG sensors, which can be derived from the relationship between PPG and ECG using PTT(Pulse Transit Time) and PWV(Pulse Wave Velocity). Unlike conventional height ratio features, which are extracted on the basis of the peaks in the PPG and ECG waveform. The proposed method can be reliably obtained even if there are missing peaks among the sensed PPG signal. The increased reliability comes from periodical estimation of the peak-to-peak interval time using ECG and PPG. After 250,000 times trials of the blood pressure measurement, the proposed estimation technique was verified with the accuracy of ±28.5% error, compared to a commercialized BP device.

The Application of the Poisson Cluster Rainfall Generation Model to the Flood Analysis (포아송 클러스터 강우생성 모형의 홍수 모의 적용성 평가)

  • Kim, Dongkyun;Shin, Ji Yae;Lee, Seung-Oh;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.5
    • /
    • pp.439-447
    • /
    • 2013
  • The applicability of the parameter map of the Modified Bartlett-Lewis Rectangular Pulse (MBLRP) model for the Korean Peninsula was assessed from the perspective of flood prediction. The design rainfalls estimated from the MBLRP model were smaller than those from observed values by 5% to 40%, and the degree of underestimation of design rainfall increases with the increase of the recurrence interval of the design rainfall. The design floods at a virtual watershed estimated using the simulated rainfall time series based on MBLRP model were also smaller than those derived from the observed rainfall time series by 20% to 45%. The degree of underestimation of design flood increases with the increase of the recurrence interval of the design flood.

Analysis of PRI Pattern with the Second Deviation of LASER Pulse Train (레이저 펄스열의 2차 차분을 이용한 PRI 패턴 분석)

  • Lim, Joong-Soo;Hong, Kyung-Ho;Jun, Gab-Song;Moon, Sung-Chul;Lee, Chang-Jae;Suh, Suhk-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.4
    • /
    • pp.63-70
    • /
    • 2008
  • This paper presents a method of PRI do-interleaving for LASER pulse signals. When the PRI of LASER pulse is periodically changed, the first deviation and the second deviation of TOA is used to calculate the PRI pattern of input LASER signals of receiver. If the standard deviation of the first difference of TOA is less than 5% of the average of the first difference of TOA, the PRI pattern of LASER signal is fixed or jittered type. If the standard deviation is larger than 5% of the average, those are triangular PRI patterns or sawtooth PRI patterns.