• Title/Summary/Keyword: Pulse Input Method

Search Result 242, Processing Time 0.037 seconds

A NEW CONTROL METHOD FOR CURRENT SHARING IN THE 12-PULSE PHASE-CONTROLLED RECTIFIER

  • Min, Byoung-Gwon;Baek, Byung-San;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.581-585
    • /
    • 1998
  • This paper presents the new current sharing control method of a 12-pulse phase-controlled rectifier(PCR) for a UPS. The control circuit of the 12-Pulse PCR with a parallel operating rectifier system is proposed to balance input currents and to reduce the harmonics of input current. The PCR is used widely in the industrial world, since its cost is much lower than that of the PWM converter and the composition of control circuits is simple. This system is developed and tested for a 3-phase 400KVA UPS system and the experimental results in this application are included.

  • PDF

A readout method using pulse peak-time capture for radiation detectors (펄스의 피크시각 포착을 이용한 방사선 검출기의 신호처리 방법)

  • Kim, Jong-ho;Kwon, Young-mok;Hong, Hyoung-pyo;Che, Gyu-shik
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.6
    • /
    • pp.651-658
    • /
    • 2017
  • There were many studies on the development of radiation measuring instruments to detect the presence of radiation. In particular, the signal processing method and treatment without loss of the detection signal are very important. The common feature for these studies is the peak-hold method that keeps the peak value of input signal uniform for a short time, readouts its value, discharges electrical value, and then waits for next signal. We propose the new methodology to capture the pulse peak value from the radiation detector and read the value directly other than peak-hold method. This method has merit of accurate reading the input signal pulse peak value without complicate process of holding for a period or initializing of input signal, and then be verified to be adequate through simulation of actual example.

Welding Parameters Optimization of Pleated Type Metallic Filter Using response surface methodology (반응표면 분석법을 이용한 Pleated Type Filter의 용접조건 최적화에 관한 연구)

  • 박형진;강문진;최병구;이세헌
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.39-41
    • /
    • 2004
  • This study is to optimize the condition of pulse parameters using the response surface method in micro pulse TIG welding of pleated type metallic filter. The input parameters used were pulse current, base current, pulse duty, frequency and welding speed and the hydraulic pressure was used as the output parameter. The central composite design was designed using second order regression model, As the results, the optimal welding condition to manufacture the pleated type metallic filter was obtained.

  • PDF

Comparison of the harmonic reduction by using harmonic passive fitters and technique of intervene firing method at the pulse of the 6-pulse phase controlled converter.

  • Wongtongdee, Surached W.;Laohasongkram, Pipat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.782-785
    • /
    • 2005
  • This article introduces technique to reduce harmonic by using the $5^{th}$ and $7^{th}$ harmonic tune filter and line reactor in the comparison to the technique of intervening firing method at the pulse of the 6-pulse phase-controlled converter in every 1/6 period. The design of the technique introduced in this article is to reduce the harmonic distortion of the current and the voltage resulted from three-phase thyristor phase-controlled converter. The waveform obtained from the experiment was analyzed on the spectrum of the current, voltage and the total harmonic distortion. The double firing method causes zero vectors of output voltage and input current. Designing the mechanism of the converter based on the idea of Park Vector Theory, the number of harmonic distortion in the intervening firing method were compared to those in normal firing method.

  • PDF

Approximation of Pulse Transfer Function of Impulse Response Data (임펄스응답 데이타의 펄스전달함수의 근사)

  • Lee, Dong-Cheol;Bae, Jong-Il;Chung, Hyeng-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.683-685
    • /
    • 1999
  • As a method of obtaining pulse transfer function. transfer function of discrete-time from input-output data, there are method of obtaining unknown parameter of pulse transfer function from estimated impulse response before(1-3). There is no need to approximate to several meanings because of not being established algebraical relations between impulse response for estimation error and parameter of transfer function exactly. In this paper, I inquire the method[4] of obtaining the optimal pulse transfer function as a meaning of Hankel norm approximation from impulse response data and examine estimated property as computer simulation from this method.

  • PDF

A New Converter System of Reducing Harmonics by 2-3 Switching Taps on Interphase Reactor (2-3 ? 변환방식에 의한 새로운 고조파 저감형 컨버어터 시스템)

  • Lee, Seong-Ryong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.4
    • /
    • pp.658-666
    • /
    • 1987
  • In this paper, a new mehtod of reducing harmonics that involved in input AC line currents or in output DC voltage of the converter system is presented. which is due mainly to the quipment of 2-3 switching taps on interphase reactor. In case that the 3 tap method is applicable to conventional 12 pulse converter, it could not bring to an effect of reducing harmonics under firing angle 15\ulcorner To solve these problems, 24 pulse or 36 pulse converter is controlled by microprocessor. The former is performed in 2 tap method when \ulcorneris less than 15\ulcorner the latter in 3 tap method when it is more then 15\ulcorner Therefore the originality of this paper liea in microprocessor based equipment of the 2-3 switching taps on interphase reactor. I applied this method to the 12 pulse converter, and proved validity of that theoretically and experimentally.

  • PDF

Performance Analysis of Pulse Positioning Using Adaptive Threshold Detector (ATD)

  • Chang, Jae Won;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.1
    • /
    • pp.25-35
    • /
    • 2018
  • This paper describes the measurement of pulse positioning (input time) to calculate a time of arrival (TOA) that takes from transmitting a signal from the target of multilateration (MLAT) system to receiving the signal at the receiver. In this regard, this paper analyzes performances of simple threshold method and level adjust system (LAS) method, which is one of the adaptive threshold detector (ATD) methods, among many methods to calculate pulse positioning of signal received at the receiver. To this end, Cramer-rao lower bound (CRLB) with regard to pulse positioning, which was measured when signals transmitted from a transponder mounted at the target were received at the receiver, was induced and then deviation sizes with regard to pulse positioning, which was measured with simple threshold and LAS methods through MATLAB simulations, were compared. Next, problems occurring according to a difference in amplitude of signals inputted to each receiver are described when pulse positioning is measured at multiple receivers located at a different distance from the target as is the case in the MLAT system. Furthermore, LAS method to resolve the problems is explained. Lastly, this study analyzes whether a pulse positioning error occurring due to the signal noise satisfies the requirement (6 nsec. or lower) recommended for the MLAT system when using these two methods.

A New input-filtering method for High Speed Counter module of PLC using embedded timer pulse function of general purpose MPU (범용 MPU 내장 타이머 펄스 출력을 이용한 PLC 고속 카운터 모듈의 입력 필터링 기능 개선)

  • Park, Kang-Hee;Lee, Sang-Beak;Han, Kyoung-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1798-1799
    • /
    • 2011
  • In this paper, A new cost-effective and accurate input noise rejection method for High Speed Counter module of PLC (Programmable Logic Controller) is proposed. By using combination of simple additional logic circuit and the Timer Pulse function of general purpose MPU, Cost-effectiveness and improvement of accuracy of filtering function can be achieved. This proposed method is verified by simulation. This proposed method is much useful for simple industrial controller based on simple microprocessor because of simplicity, accuracy and low cost.

  • PDF

Single-Phase Inverter System Using New Modulation Method (새로운 변조방식을 사용한 단상 인버터 시스템)

  • Lee, Hyoung-Ju;Won, Hwa-Young;Lim, Seung-Beom;Hong, Soon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.29-36
    • /
    • 2010
  • In this paper, we propose a single-phase inverter system using new modulation method. The proposed system is composed of a buck-boost converter and an inverter and controlled by PWAM scheme. PWAM method is a new modulation method which is the incorporation of PWM(Pulse Width Modulation) and PAM(Pulse Amplitude Modulation) methods. The DC voltage which is the input voltage of buck-boost converter is converted into a variable DC voltage by buck-boost converter. Also, the variable DC voltage which is the output voltage of buck-boost converter is converted into a sinusoidal AC voltage by inverter. The input voltage of inverter is processed by PWM switching in PWM section and bypassed in PAM section. By using PWAM method, switching action is not existed in PAM section and thus the times of switching is reduced. As a result, the switching loss can be reduced.

Analysis of Magnetic Circuit and Static Thrust of a Double-sided Linear Pulse Motor (양측식 선형펄스모터의 자기회로 및 정추력해석)

  • 박한석;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.49-55
    • /
    • 1996
  • In this paper, the characteristics of a double-sided linear pulse motor (DLPM) with permanent magnet are analysed using the method which combined the coenergy method and the equivalent magnetic circuit method. In the process of computation, the magnetic material nonlinealities of the permanent magnet, the primary and the secondary core are interpolated by the cubic spline method. Then, the equivalent magnetic circuit modelled by the permeance method including airgap reluctance, which is a function of displacement, is obtained. The static thrust which is the derivative of coenergy is computed by Newton Raphson method at each dispacement. And, in order to investigate the characteristics of the DLPM, the thrust shows as a function of displacement, input current and air gap. The simulation resuls are compared with experimental ones obtained from the DLPM with 2 phase and 4 poles.

  • PDF