• 제목/요약/키워드: Pulse Detector

검색결과 207건 처리시간 0.028초

MAP Estimation을 이용한 QRS Detection (QRS detection based on maximum a-posteriori estimation)

  • 정희교;신건수;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.709-712
    • /
    • 1987
  • In this paper, a mathematical model for the purpose of QRS detection is considered in the case of the occurrence of nonoverlapping pulse-shaped waveforms corrupted with white noise. The number of waveforms, the arrival times, amplitudes, and widths of QRS complexes are regarded as random variables. The joint MAP estimation of all the unknown quantities consists of linear filtering followed by an optimization procedure. Because of time-consuming, the optimization procedure is modified so that a threshold test is obtained. The model formulation with nonoverlapping waveforms leads to a standard procedure covering a segment before as well as after an accepted event. Adaptivity of the detector is gained by utilizing past signal properties in determining threshold for QRS detection.

  • PDF

변압기내 부분방전 탐지 및 위치검출 (Detection and Location of Partial Discharge in Transformers)

  • 곽희노;김재철;황선주;권태원;윤용범
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권4호
    • /
    • pp.53-59
    • /
    • 1992
  • This paper describes an instrument for the detection and geometric location of partial discharge (PD) source in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulses and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used for detecting and locating PD in the transformer.

  • PDF

가스절연기기 내부의 금속 이물질에 의한 초고속 부분방전량 및 전류 측정 (Ultra-fast meseurement of partial discharge current due to conducting particle in Gas-insulated System (GIS))

  • 박기준;구선근;윤진열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.160-164
    • /
    • 2002
  • A special discharge cell containing a free conducting particle was used to generate the discharges in $SF_6$. The analog bandwidth of the measurement system exceeded 5 GHz. The measured signals were processed to compensate for the response of the measurement system. The discharge current rise time was in the range of 70 ps, while its full-width half-maximum was 120 ps. Single and double current pulses of positive and negative polarities were measured. Likewise, these pulses were compared with the measurement obtained using a conventional partial discharge detector of the IEC60270 type

  • PDF

교육용 로보트의 설계에 관한 연구 -DC써어보모타의 위치 및 속도제어기를 중심으로 (A Study on the Design of an Educational Robot System -On a Speed and Position Controller of DC Servo Motor-)

  • 고명삼;권욱현;이장규;이상욱;권순학
    • 대한전기학회논문지
    • /
    • 제33권9호
    • /
    • pp.327-339
    • /
    • 1984
  • In this paper we present how to design the software-based speed and position controller of a DC servo drive system for an educational robot. The controller designed by fully digital scheme consists of a CPU, drive unit, encoder pulse coding unit, speed and position detector. The control algirithm of the controller is a hybrid one such that speed control and position control are switched at some instant to get more accuracy. The experimental resusts of the proposed DC servo-controller show good performances for the position and speed control of the proposed educational robot system.

  • PDF

Nonconstrained Blood Pressure Measurement by Photoplethysmography

  • Yoon Young-Zoon;Yoon Gil-Won
    • Journal of the Optical Society of Korea
    • /
    • 제10권2호
    • /
    • pp.91-95
    • /
    • 2006
  • Blood pressure was predicted from photoplethysmography (PPG). To obtain PPG, backscattered light from a fingertip was measured and its waveform was analyzed. Systolic upstroke time and diastolic time in the pulse waveform were used as parameters to predict blood pressure. The experiment was carried out with five subjects on five different days. The systolic upstroke time had a correlation coefficient of -0.605 with respect to systolic blood pressure and the diastolic time had a correlation coefficients of -0.764 for diastolic pressure. This PPG method does not require an air-cuff installation on the arm and can predict blood pressure continuously. This simple LED/photo detector setup can be a good candidate for nonconstrained monitoring of blood pressure variations.

13.56MHz RF시스템에서의 필터 설계 및 시뮬레이션 (Design and Simulation for the Filter of RFID System Operated at 13.56MHz)

  • 류형선;진인수;양경록;송성호;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3145-3147
    • /
    • 2000
  • A passive RFID system consists of reader and tag. Reader is required the filter to modulate the data from backscattering signal which is transmitted by tag. The filter in the reader consists of envelope detector, amplifier, filter, and pulse shaping circuit, In this paper, design and analysis of filter in the RFID system which is operated at l3.56MHz carrier and 70KHz backscattering signal frequency is presented and is confirmed by simulation using Pspice.

  • PDF

Spectral-Domain 광 계측을 위한 CCD 이미지 센서 드라이버 제작 (Realization of CCD Image Sensor Driver for Spectral-Domain Optical Measurement System)

  • 김훈섭;이정렬;엄진섭
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.125-128
    • /
    • 2007
  • This paper presents Spectral-Domain optical measurement system using self-fabricated CCD sensor driver. The light source is a high brightness white LED and the detector is a 2048 array typed CCD image sensor. I have fabricated the CCD sensor driver to generate four pulse signals, which are the CCD-driving pulses. Using this Spectral Domain optical measurement system, the distance value between the reference mirror and the sample mirror can be obtained successfully.

  • PDF

다층 저항판 검출기용 신호 검출 전자 회로 설계 (Design of a Front-End Electronic Circuit for Signal Detection on Multi-gap Resistive Plate)

  • 이승욱;김종태;채종서
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2552-2554
    • /
    • 2001
  • This paper presents a front-end electronic circuits for signal detection on multi-gap resistive plate. The input to the circuit is the signal(voltage : -800mv, frequency : 20${\sim}$40MHZ, noise : 50mv, 1GHz) from the multi-gap resistive plate chamber and the output is the 5v pulse signal. The front-end electronic circuit consists of preamplifier, peak-detector, and comparator. Spice simulation show that the circuit has the better response time than the one of the conventional measuring instruments.

  • PDF

광변조를 이용한 다채널 무선 통신에 관한 연구 (Multi-channel wireless communication using light modulation)

  • 조성민;이혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.382-384
    • /
    • 1994
  • Wireless communication has become a hot issue for its simplicity. Using light wave instead of micro wave has many advantages. It is simple to design a circuit because we can make a circuit with discrete components such as photo diode, photo detector, OP Amp[2]. And we can have many communication channels for we can use every frequency domain. In this paper, we design the wireless communication system and analyze the pulse signal. Then using ray tracing technology we simulate the distribution of light beam.

  • PDF

대전입자형 디스플레이의 응답특성 (Response Characteristics of Charged Particle Type Display)

  • 이동진;김영조
    • 한국전기전자재료학회논문지
    • /
    • 제22권2호
    • /
    • pp.169-173
    • /
    • 2009
  • We studied driving characteristics according to the ratio of mass and charging (m/q) value for charged toner particles with black and yellow color in charged particle type display panel. After biasing rectangle pulse to the transparency electrodes of putted panel with toner particles, its response time and contrast ratio are simultaneously measured using a laser as a optical source, photodiode as a detector and reflective system. As a results, contrast ratio is largest at the shortest response time region which is different to the particle because of m/q. We proposed relational equation for response time, m/q, cell gap and biasing voltage. It has not been studied and reported to analyze the relationship of response time, biasing voltage, lumping phenomena, cell gap, and contrast ratio for toner particle type display.