• Title/Summary/Keyword: Pulse Detector

Search Result 207, Processing Time 0.031 seconds

3 Dimensional Pulse Detector Using SMA Connector (SMA 커넥터를 이용한 3축 펄스 탐지기)

  • Lee, Sangsu;Park, Yong Bae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.9
    • /
    • pp.707-712
    • /
    • 2017
  • In this paper, the performance characteristic of 3 dimensional pulse detector using SMA connector is analyzed. Modeling of 3D pulse detectors is done in a commercial simulator. When a pulse is incident on the detector, we analyze the performance characteristics of the detector and verify the feasibility of the pulse detector.

Pulse Radiation Dose Measurement using the Peak Detector (Peak Detector를 이용한 펄스방사선 선량 측정)

  • Jeong, Sang-hun;Lee, Nam-ho;Oh, Seong-chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1020-1022
    • /
    • 2013
  • In this paper, proposed peak detector for the measurement of pulse radiation dose. The speed of the pulse radiation signal is the between a few ns and tens ns. Therefore, it is difficult to measure peak voltage. Peak Detector maintains the peak voltage generated from the sensor for a few ms and the converted signals can be easily measured using the ADC. The peak detector simulation results peak value remained of more than 1ms. Pulse radiation irradiation test results, a dose of $1.95{\times}10^6rad/s$ was measured.

  • PDF

Development of a Bipolar Pulse Conductometric Detector for Environmental Monitoring and Electrochemical Experiments (환경수질오염 검증과 전기화학실험을 위한 양극펄스형 전기전도성검출기의 개발)

  • Kim, Haidong;Kim, Sun Tae;Kim, Taek-Jae;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.79-82
    • /
    • 1992
  • A bipolar pulse conductometric detector has been developed for continuous on-line monitroring of the flowing sample streams. The conductometric detector was fast and easy to use due to the free of interferences by serial or parallel capacitances. The performance of the bipolar pulse conductometric detector was tested using dummy cells with $10^1{\sim}10^8$ ohm resistance range and found a linear response with a 0.01% relative standard deviation. The possible applications of the bipolar pulse conductometric detector was discussed.

  • PDF

A scintillation detector configuration for pulse shape analysis

  • Van Chuan, Phan;Hoa, Nguyen Duc;Hai, Nguyen Xuan;Anh, Nguyen Ngoc;Dien, Nguyen Nhi;Khang, Pham Dinh
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1426-1432
    • /
    • 2018
  • This paper presents a neutron detector configuration using EJ-301 scintillation liquid, a R9420 photo-multiplier and a homemade preamplifier. The detector qualities which include the energy linearity, efficiency response and neutron/gamma discrimination are guaranteed for neutron detection in the energy range from 0 to 3000 keVee. Regarding the neutron/gamma discrimination capability, four pulse shape discrimination (PSD) methods which are the threshold crossing time (TCT), pulse gradient analysis (PGA), charge comparison (CC) and correlation pattern recognition (CPR), were evaluated and discussed; among of these, the CPR method provides the best neutron/gamma discrimination.

Voltage dependent pulse shape analysis of Geiger-Müller counter

  • Almutairi, B.;Akyurek, T.;Usman, S.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1081-1090
    • /
    • 2019
  • Detailed pulse shape analysis of a Geiger-$M{\ddot{u}}ller$ counter is performed to understand the pulse shape dependence on operating voltage. New data is presented to demonstrate that not all pulses generated in a GM counter are identical. In fact, there is a strong correlation between the operating voltage and the pulse shape. Similar to detector deadtime, pulse shapes fall in three distinct regions. For low voltage region, where deadtime was reported to reduce with increasing voltage, pulse generated in this region was observed to have a fixed pulse width with a variable tail. The pulse width and fall time of the tail was observed to be a function of applied voltage; exponentially reducing with increasing voltage with an exponent of negative 6E-04 and 2E-03 respectively. The second region showed a pulse without any significant tail. During this time the detector deadtime was earlier reported to be at its minimum. The highest voltage region demonstrated a different deadtime mechanism where the second pulse was reduced in width. During this time the deadtime seemed to be increasing with increasing voltage. This data allows us to gain some unique insight into the phenomenon of GM detector deadtime not reported thus far.

Performance Analysis of Detector in Automobile Pulse Radar with Considering Interference (차량용 펄스 레이더에서 간섭영향에 대한 검출기의 성능 분석)

  • Lee, Jonghun;Ko, Seokjun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 2019
  • In this paper, we consider interferences from other automobile pulse radars using same frequency spectrum. In order to eliminate the interference, we propose the PN code modulation method. This method uses the cross-correlation between PN codes with different seed. The ROC performance is used for comparing the proposed detector to conventional method. And the proposed detector can decide the present or absent of targets and measure the range of the targets by using memory buffer of range gate. Especially, we use false alarm probability for all range gates. That is the false alarm if in any one range gate the false alarm occurs. From the simulation result, we can see that the proposed detector with using PN code is not influenced by interferences.

Fault Detector and Length Measurement of Electric Cables Based on Frequency Waves

  • Chawporn, Talerngkiat;Chaikla, Amphawan;Sriratana, Witsarut;Trisuwannawat, Thanit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.45-48
    • /
    • 2003
  • This research presents an approach to simultaneously detect the faults and measure the length of the electric cables. This approach is easy to use and inexpensive. Moreover, it can be applied to any kinds and sizes of the electric cable. This paper uses 750V $4{\times}4$ Sq.mm. cables. The concept is to send the 2 kHz pulse into the electric cable. When the pulse bumps into the fault, it bounces back. Then, the total time the pulse travels back and forth and the shape of the pulse after bumping are inspected using the pulse detector and pulse converter. Next, the signal obtained is modulated with 10 MHz carrier pulse to segregate into several small pulses before sending to 8-bit counter. The length of the electric cable can be obtained using microcontroller and the location of the faults can be seen on the LCD screen. This approach can be used to inspect the electric cables with the length of at least 15 m.

  • PDF

Performance Analysis of Pulse Positioning Using Adaptive Threshold Detector (ATD)

  • Chang, Jae Won;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.1
    • /
    • pp.25-35
    • /
    • 2018
  • This paper describes the measurement of pulse positioning (input time) to calculate a time of arrival (TOA) that takes from transmitting a signal from the target of multilateration (MLAT) system to receiving the signal at the receiver. In this regard, this paper analyzes performances of simple threshold method and level adjust system (LAS) method, which is one of the adaptive threshold detector (ATD) methods, among many methods to calculate pulse positioning of signal received at the receiver. To this end, Cramer-rao lower bound (CRLB) with regard to pulse positioning, which was measured when signals transmitted from a transponder mounted at the target were received at the receiver, was induced and then deviation sizes with regard to pulse positioning, which was measured with simple threshold and LAS methods through MATLAB simulations, were compared. Next, problems occurring according to a difference in amplitude of signals inputted to each receiver are described when pulse positioning is measured at multiple receivers located at a different distance from the target as is the case in the MLAT system. Furthermore, LAS method to resolve the problems is explained. Lastly, this study analyzes whether a pulse positioning error occurring due to the signal noise satisfies the requirement (6 nsec. or lower) recommended for the MLAT system when using these two methods.

Quadrature Phase Detector for High Speed Delay-Locked Loop

  • Wang, Sung-Ho;Kim, Jung-tae;Hur, Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05a
    • /
    • pp.28-31
    • /
    • 2004
  • A Quadrature phase detector for high-speed delay-locked loop is introduced. The proposed Quadrature phase detector is composed of two nor gates and it determines if the phase difference of two input clocks is 90 degrees or not. The delay locked loop circuit including the Quadrature phase detector is fabricated in a 0.18 urn standard CMOS process and it operates at 5 ㎓ frequency. The phase error of the delay-locked loop is maximum 2 degrees and the circuits are robust with voltage, temperature variations.

  • PDF

Performance Analysis of the Clutter Map CFAR Detector with Noncoherent Integration

  • Kim, Chang-Joo;Lee, Hyuck-Jae
    • ETRI Journal
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 1993
  • Nitzberg has analyzed the detection performance of the clutter map constant false alarm rate (CFAR) detector using single pulse. In this paper, we extend the detection analysis to the clutter map CFAR detector that employs M-pulse noncoherent integration. Detection and false alarm probabilities for Swerling target models are derived. The analytical results show that the larger the number of integrated pulses M, the higher the detection probability. On the other hand, the analytical results for Swerling target models show that the detection performance of the completely decorrelated target signal is better than that of the completely correlated target.

  • PDF