• Title/Summary/Keyword: Pulse Control

Search Result 2,238, Processing Time 0.038 seconds

Independent PRF Generation and Control for Frequency Phase Calibration on Mono-pulse Radar at a Remote Location (원격지에서 모노펄스 레이더의 주파수 위상 교정을 위한 독립된 펄스반복주파수 생성 및 제어)

  • Yang, Jaewon;Yoo, Seungoh;Yoon, Jaehyuk;Lee, Dongju
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.368-373
    • /
    • 2021
  • This paper presents a method of independent pulse repetition frequency(PRF) generation and control for frequency phase calibration on mono-pulse radar at a remote location. In order to generate an independent PRF signal of 320[Hz], pulse width modulation(PWM) of 16-bit timer/counter was applied. For a precision control of PRF signal, 16-bit timer/counter interrupt was changed for each period. Therefore, average frequency of PRF could be controlled by 0.0001[Hz]. To calibrate a frequency phase of mono-pulse radar at a remote location, the proposed PRF generator with a precision control of frequency was used regardless of receiving PRF signal from a radar. For the verification of the proposed PRF generator, theoretical analysis and experimental results are included.

3 Stage 2 Switch Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.234-239
    • /
    • 2011
  • Transcranial magnetic stimulation utilizes the method of controlling applied time and changing pulse by output pulse through power density control for diagnosis purposes. Transcranial magnetic stimulation can also be used in cases where diagnosis and treatment are difficult since output pulse shape can be changed. As intensity, pulse range, and pulse shape of the stimulation pulse must be changed according to lesion, the existing sine wave-shaped stimulation treatment pulse poses limitations in achieving various treatments and diagnosis. This study actualized a new method of transcranial magnetic stimulation that applies a 3 Stage 2 Switch( power semiconductor 2EA) for controlling pulse repetition rate by achieving numerous switching control of stimulation coil. Intensity, pulse range, and pulse shape of output can be freely changed to transform various treatment pulses in order to overcome limitations in stimulation treatment presented by the previous sine wave pulse shape. The method of freely changing pulse range by using 3 Stage 2 Switch discharge method is proposed. Pulse shape, composed of various pulse ranges, was created by grafting PFN (Pulsed Forming Network) through AVR AT80S8535 one-chip microprocessor technology, and application in transcranial magnetic stimulation was achieved to study the output characteristics of stimulation treatment pulse according to delaying time of the trigger signal applied in section switch.

Development of a Pulse Light System for Treating Skin Pigmentation (피부의 색소치료를 위한 펄스 광 시스템의 개발)

  • Jeun, Jong-Baeg;Tack, Han-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.1
    • /
    • pp.81-87
    • /
    • 2021
  • In this study the skin care system was designed and tested by introducing V-IPL(Variable-Intense Pulse Light) methods that allow various skin treatments. The discharge method, a new method of switching on the flash lamp sequentially according to the lesions, was used. Pulse shape control is implemented in the system using the conventional LC variable method and the switching method control method of the switching element. As a result, the pulse width could be varied up to 1[㎛] by using a microprocessor, and by turning on the flash lamp sequentially along the lesions the depth and width, the pulse shape and pulse shape could be more diverse. We could also make long pulses of up to 1~100[ms] in various pulse width. And the special differences between the existing system and the proposed system in this study are as follow. Existing system is one pulse(pulse width : 1~40ms) and proposed system is three pulse(pulse width : 1~100ms).

Pulse Laser Power Stabilization Using PID Control Method (PID 제어기법을 이용한 펄스 레이저 출력 안정화에 관한 연구)

  • Ryoo, Hoon-Chul;Kwak, Seung-Woo;Kang, Dong-Won;Kim, Kyoung-Sik;Hahn, Jae-Won
    • Laser Solutions
    • /
    • v.9 no.2
    • /
    • pp.17-22
    • /
    • 2006
  • In this study, PID control method was applied to decrease the power fluctuation of the pulse laser which is one of the major processing variables in laser machining process. To stabilize the power fluctuation of the pulse laser, we averaged 10 pulse outputs of Nd:YAG laser operating in 10Hz using boxcar averager, and with taking this averaged output as an input signal, we conducted PID control using optical attenuator which is consisted of half wave plate attached on the stepping motor and polarizer. When PID control was not enabled, the power fluctuation was 4.71% and with PID control, the power fluctuation was 1.86% for 2 hours and 1 hour respectively. As a result, we stabilized the power fluctuation of the pulse laser by 60.5%

  • PDF

Pulse Laser Power Stabilization Using PID Control Method (PID 제어기법을 이용한 펄스 레이저 출력 안정화에 관한 연구)

  • Ryu, Hoon-Chul;Kwak, Seung-Woo;Kang, Dong-Won;Kim, Kyoung-Sik;Hahn, Jae-Won
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2006.06a
    • /
    • pp.89-96
    • /
    • 2006
  • In this study, PID control method was applied to decrease the power fluctuation of the pulse laser which is one of the major processing variables in laser machining process. To stabilize the power fluctuation of the pulse laser, we averaged 10 pulse outputs of Nd:YAG laser operating in 10Hz using boxcar averager, and with taking this averaged output as an input signal, we conducted PID control using optical attenuator which is consisted of half wave plate attached on the stepping motor and polarizer. When PID control was not enabled, the power fluctuation was 4.71% and with PID control, the power fluctuation was 1.86% for 2 hours and 1 hour respectively. As a result, we stabilized the power fluctuation of the pulse laser by 60.5%

  • PDF

Development of the Switching Mode Conversion Type Pulse Charger for the Lead Battery of Solar Cell Generator Equipment by Fly-Back Converter Method (플라이백 컨버터방법에 의한 태양광발전설비의 납축전지 스위칭모드 전환형 펄스충전기 개발)

  • Shin, Choon-Shik;An, Young-Joo;Kim, Dong-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.20-26
    • /
    • 2009
  • In this paper, the switching mode conversion type pulse charger by fly-back converter method for lead battery of the solar cell generator equipment is proposed. And we propose the control circuit and design method of insulated switching mode convert type pulse charger by fly-back convert method in the lead battery. The proposed system can minimize the current consumption by digital pulse. Also the proposed system can generate the constant 10[KHz] frequency, transmit the signal with main control system in the power control system. And it supervises the state of lead battery using one chip micro processor. The proposed the switching mode conversion type pulse charger by the fly-back converter method can charge fast and stabilize lead battery with nominal value 12[V], 20[AH]. Also we propose the design procedure of the power control circuit for turn ratio of fly-back inductor and determining method of values such as the charging current, bulk current, partial current, over current value and fixed charging voltage. The experiment results for the voltage and current wave for partial, bulk, over and fixed charging period show the good charging effect and performance. And the PCB and internal coupling diagram of the switching mode conversion type pulse charger by fly-back converter method is presented.

Analysis of Blood Pressure Pulse in Female High School Students with Menstrual Disorders (월경장애를 가진 여고생의 맥진분석)

  • Kim, Soo-Hyun;Cho, Hye-Sook;Lee, In-Seon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.1
    • /
    • pp.82-91
    • /
    • 2013
  • Objectives: The purpose of this study is to find out the patterns of teenage girls who is easy to suffer from Menstrual Disorders. Methods: The data from the 1681 participants were collected using a structured menstrual history questionnaire. Based on the survey responses, we had 97 adolescents with menstrual disorder as the test group and 97 adolescents without menstrual disorder as the control group. The clinical trials subjects were asked to respond to another questionnaire for identifying Blood Pressure Pulse Analyzer tests. We identified significant variables for dysmenorrhea from comparison between the test and control group; a binary response variable from the test group's responses for ever experiencing dysmenorrhea and explanatory variables from Blood Pressure Pulse Analyzer. Results: The reselts of Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower in dysmenorrhea group than the control group. The reselts of Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower, and T4_R were higher in hypomenorrhea group than the control group. The reselts of Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower in Irregular Menstruation group than the control group. Conclusions: Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower in the test group than the control group.

Pressure Control of a Variable Thrust Solid Propulsion System Using On-Off Controllers (On-Off 제어기를 이용한 가변추력 고체추진 기관의 압력제어)

  • Kwon, Soon-Kyu;Kim, Young-Seok;Ko, Sang-Ho;Suh, Seok-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.942-948
    • /
    • 2011
  • Solid propulsion systems have simple structures compared to other propulsion systems and are suitable for long-term storage. However the systems generally have limits on control of thrust levels. In this paper we introduce controllers for combustion chamber pressure using on-off control techniques which have been known for relatively easy implementation and energy efficiency. For this, we use a simple pressure change model by considering only mass conservation within the combustion chamber and we design a classical controllers and on-off controllers with are Pulse Width Modulation(PWM) and Pulse Width Pulse Frequency Modulation (PWPFM). Then we compare the performance results of the controllers through numerical simulations.

  • PDF

A Study on the Pulsed $CO_2$ Laser by the Switching Control of Leakage Transformer Primary (누설변압기 1차측의 스위칭 제어에 의한 펄스형 $CO_2$레이저에 관한 연구)

  • Chung, Hyeon-Ju;Lee, Dong-Hoon;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.9
    • /
    • pp.541-545
    • /
    • 2000
  • We propose a pulsed $CO_2$laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantages of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5 Hz to 60 to Hz control laser output. In this laser a low voltage open loop control for high voltage pulse discharge circuit is employed to aviod the Hv sampling or switching and high voltage leakage transformer is used to convert low voltage pulse rectified from AC to high voltage one. A ZCS(Zero Crossing Switch) circuit and a PIC(programble one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leadkage inductance. The maximum laser output was about 23 W at pulse repetition rate of 60Hz total gas mixture of $CO_2$ : $N_2$ : He=1: 9: 15 and total pressure of 18 Torr

  • PDF

Power Tracking Control of Domestic Induction Heating System using Pulse Density Modulation Scheme with the Fuzzy Logic Controller

  • Nagarajan, Booma;Sathi, Rama Reddy;Vishnuram, Pradeep
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1978-1987
    • /
    • 2014
  • Power requirement to the induction heating system varies during the heating process. A closed loop control is required to have a smooth control over the power. In this work, a constant frequency pulse density modulation based power tracking control scheme for domestic induction heating system is developed using the Fuzzy Logic Controller. In the conventional power modulation schemes, the switching losses increase with the change in the load. The proposed pulse density modulation scheme maintains minimum switching losses for the entire load range. This scheme is implemented for the class-D series resonant inverter system. Fuzzy logic controller based power tracking control scheme is developed for domestic induction heating power supply for various power settings. The open loop and closed loop simulation studies are done using the MATLAB/Simulink simulation tool. The control logic is implemented in hardware using the PIC16F877A microcontroller. Fuzzy controller tracks the set power by changing the pulse density of the gate pulses applied to the inverter. The results obtained are used to know the effectiveness of the fuzzy logic controller to achieve the set power.