• Title/Summary/Keyword: Pulsation

Search Result 589, Processing Time 0.033 seconds

A Study on the Eddy Diffusion in a Pulsed Turbulent System (脈動渦流裝置에 있어서의 渦流擴散)

  • Woong Ki Kang;Yung Wook Kim
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.3
    • /
    • pp.203-206
    • /
    • 1963
  • The eddy diffusion in the pulsed wetted wall column, where the spherical balls are consecutively arrayed along the axis of the column and turbulence is caused around the balls by pulsation, has been studied both theoretically and experimentally. A diffusion equation is solved for a longitudinal column where a concentration impulse is given at the top of the column, and the experimental results, which are the impulse response measurements at the half of the total height of the column, have shown a good agreement with the developed theory. A method of measuring the eddy diffusivity, which is based on the slope of concentration vs. time in the particular interval of concentration, is proposed and the measured diffusivity is used as a criterion of comparing the theory and the experiment. The eddy diffusion is remarkably increased as the amplitude and the frequency of the pulsation increase but the increasing rate is decreased as the pulsation increases.

  • PDF

Dust Shells around OH/IR Stars

  • Suh, Kyung-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.5 no.2
    • /
    • pp.81-96
    • /
    • 1988
  • We have made new models for mass-losing OH/IR stars to explain the properties of the dust shells around them using more accurate information about the material in the shell and the physical precesses including pulsations. We have applied our dust opacity which has been deduced from observations and experimental data to various density distributions, calculated the model emergent spectra, and compared with observations. Contrary to previous suggestions, we could fit observations fairly well using density distribution $\rho\propto r^{-2}$, which is physically plausible, with proper choice of opacities. The time scales for dust formation, growth, and movement are calculated to be compared with pulsation periods. The change of the emergent spectrum depending on the phase of pulsation can be explained fairly well by changing dust condensation radius(for fixed dust condensation temperature) in step with the change in stellar luminosity. The effects of stellar wind models and pulsation models on dust shells with attention to emergent spectra are discussed.

  • PDF

The Analysis of Discharge Pressure Noise Characteristics Of Vane Pump for Automatic Transmission (자동변속기용 베인펌프의 토출압 노이즈 특성 해석)

  • Choi, Y.Y.;Choi, H.J.;Lee, S.H.;Jung, W.J.
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.33-38
    • /
    • 2010
  • As for an oil hydraulic vane pump of vehicle hydraulic systems, the highest of planning technique required by the acquisition of optimum profile data which can be available to predict noises and vibrations. Pressure pulsation may result in considerable vibration and noise of pump component as well as cavitation in hydraulic system. The influences of the discharge pressure and rotating speed of the vane on the dynamic pressure in chamber surrounding a vane have been investigated. It is very important to predict pressure pulsation in vane pump. This paper presents analysis of technique of vane pump for automatic transmission. The predicted result using AMESim model were good agreement with the experimentally obtained results.

  • PDF

Flow Control and Heat Transfer Enhancement from a Heated Block by an Inflow Pulsation (II) Thermal Field Computation (입구 유동 가진에 의한 사각 발열체 주위의 유동제어 및 열전달촉진 (II) 온도장 수치해석)

  • 리광훈;김서영;성형진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.599-606
    • /
    • 2002
  • uniform temperature. The surfaces of the block are taken at a constant higher temperature. The channel walls are assumed to be adiabatic. Results on the time-dependent temperature field are obtained and averaged over a cycle of pulsation. The effect of the important governing parameters, such as the Strouhal number on the flow and the heat transfer is investigated in detail. The results indicate that the recirculating flow behind the block are substantially affected by the pulsation frequency. These, in turn, have a strong influence on the thermal transport from the heated element to the pulsating flow. The frequency at which the enhancement is maximum is determined.

A Study on the Gas Pulsation in a Horizontal Scroll Compressor (횡형 스크롤 압축기의 가스 맥동에 관한 연구)

  • Choi, Jin Sub;Kim, Hyun Jin
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.41-45
    • /
    • 1999
  • Analytical and experimental investigations have been carried out on the gas pulsations in the discharge paths of a high-side horizontal scroll compressor, where the gas discharged from compression chamber is made to pass through several chambers inside the compressor shell. Model of Helmholtz resonators in series has been applied to this configuration to predict gas pulsation phenomena along the passages, and the calculation results have been compared with measured pressure time traces. Good agreements between the analytical and experimental results have been obtained. It has also been found that the compressor performance is somewhat affected by the size of individual chambers Inside the compressor shell.

  • PDF

Evalution of Hemolysis in Axial Flow Blood Pump with Computational Fluid Dynamics Analysis (전산유체해석을 이용한 축류형 혈액펌프의 용혈평가)

  • 임상필;김동욱
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.256-259
    • /
    • 2003
  • Artificial heart is divided pulsation style and nonpulsation style greatly according to flowing of blood. nonpulsation pump is advantage of miniaturization avaliable because it is simple and non-volumic-pump than pulsation pump. Non pulsation pump is derided axial flow style and centrifugal style accordig to rotating style. An axial flow blood pump can be made smaller than a centrifugal blood pump because of its higher specific speed. A hemolysis is an important factor for the development of an axial flow blood pump. It is difficult to identify the areas where hemolysis nun. Evaluation of hemolysis both in in vitro and in vivo require a long time and are costly. Computational fluid dynamics(CFD) analysis enables the engineer to predict hemolysis on a computer. The aims of this study is Computational fluid dynamics in the whole axial flow pump and to verify the accuracy of prediction results of CFD analysis compare with in vitro experimental results.

  • PDF

Development of the Hydraulic Gear Pump for an Elevator (엘리베이터용 기어펌프 개발)

  • Jeong, Seok-Hoon
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.117-124
    • /
    • 2011
  • A gear pump is a type of pump that displaces a volume of fluid by physical or mechanical action, or positive displacement pump. Power is applied to one of the gears and transmitted to a second driven gear via meshing teeth. This paper describes the hydraulic gear pump for an elevator. In gear pump, since geometrically special forms of gear tooth, 'Pulsations' is always caused in the delivery pressure and quantity. In other words, it is found that the number of delivery pressure pulsation per each revolution is always equal to that of the gear-teeth of the gear, which is coincident with the pulsation of the ideal delivery quantity. Some experimental results are given to verify the effectiveness of the developed pump.

Modification of acceleration signal to improve classification performance of valve defects in a linear compressor

  • Kim, Yeon-Woo;Jeong, Wei-Bong
    • Smart Structures and Systems
    • /
    • v.23 no.1
    • /
    • pp.71-79
    • /
    • 2019
  • In general, it may be advantageous to measure the pressure pulsation near a valve to detect a valve defect in a linear compressor. However, the acceleration signals are more advantageous for rapid classification in a mass-production line. This paper deals with the performance improvement of fault classification using only the compressor-shell acceleration signal based on the relation between the refrigerant pressure pulsation and the shell acceleration of the compressor. A transfer function was estimated experimentally to take into account the signal noise ratio between the pressure pulsation of the refrigerant in the suction pipe and the shell acceleration. The shell acceleration signal of the compressor was modified using this transfer function to improve the defect classification performance. The defect classification of the modified signal was evaluated in the acceleration signal in the frequency domain using Fisher's discriminant ratio (FDR). The defect classification method was validated by experimental data. By using the method presented, the classification of valve defects can be performed rapidly and efficiently during mass production.

Study on Breathing and Pulsation, Chongu and Inyeong of Healthy Man (평인(平人)의 호흡맥동(呼吸脈動)과 촌구인영(寸口人迎)에 대한 연구)

  • Lee, Hye-Yeon;Kang, Jung-Soo
    • Journal of Korean Medical classics
    • /
    • v.22 no.4
    • /
    • pp.1-13
    • /
    • 2009
  • When feeling the pulse, healthy man' pulse is the criterion for diagnosis whether you are a sick person. Healthy man is defined as one who is harmonious and not sick in sympathy with natural order. Among the factors for being Healthy man, breathing and pulsation, Chon-gu(寸口) and Inyeong(人迎) are most closely connected with the representative methods of feeling the pulse which are used currently. According to "Hwangjenaegyeong(黃帝內經)" on breathing and pulsation, the pulse beats twice per a breathing-in and a breathing-out each. And for a specific breathing, it beats 5 times including the remnant with a big breath. That the pulse beats twice means that it beats not only twice, but also regularly and repeatedly. The remnant is related to the meaning on a leap month, 5-time beating during a breath is connected with the contents of Osipyeong(五十營). A human is not always in stable and sticks to balance continuously with changes under the circumstances. So when it comes to a criterion how to measure the pulsation frequency, breathing is much more reasonable than pulsation and breathing calculated for a minute. According to "Hwangjenaegyeong(黃帝內經)", Healthy man is the person of whose Chon-gu and Inyeong are in order and much the same in response to each other. Although there is a minor difference in the meaning of term between Chon-gu and Gigu(氣口), Maekgu(脈口) in originally, it is used as almost same meaning when Chon-gu is used in opposition to Inyeong. Afterwards, depending on medical men, around neck or Chon-gu of the left hand are measured for Inyeong. However, Inyeong described in "Naegyeong(內經)" is Jokyangmyeong(足陽明) and it means the Hyeol(穴) around neck where the pulse beats, it looks like about the carotid area. Chon-gu is fall under Eum(陰) and Inyeong(人迎) is fall under Yang(陽). Therefore Chon-gu is continuous with eumgyeong(陰經) and Inyeong is continuous with yanggyeong(陽經). In addition, the pulse and the four seasons meet each other and Inyeong is a little stronger in spring summer and Chongu is a little stronger in fall winter.

  • PDF

Effect of the Reflectivity of Both Facets and the Phase of a Phase Tuning Section on the Yield Characteristics of a Multisection Complex-Coupled DFB Laser with Self-Pulsation Frequency of THz Region (양 단면 반사율과 위상 조정 영역의 위상이 Self-Pulsation 주파수가 THz 대역인 다중 영역 Complex-Coupled DFB 레이저의 수율 특성에 미치는 영향)

  • Kim, Tae-Young;Park, Jae-Woo;Kim, Boo-Gyoun
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.208-218
    • /
    • 2008
  • We investigate the effect in terms of yield of the reflectivity of both facets and of the phase of a phase tuning section on the self-pulsation (SP) characteristics of multisection complex-coupled (CC) DFB lasers with self-pulsation frequency of the THz region. When the grating phases on both facets of a multisection CC DFB laser are fixed as 0, the variation of SP frequency increases as the reflectivity of both facets increases, while that of SP frequency decreases as the coupling ratio (CR) and the coupling strength increase. For the coupling strength of 3, the range of the phase of a phase tuning section with yields greater than 80% decreases as the CR and the reflectivity of both facets increases. For the coupling strength of 4, the range of the phase of a phase tuning section with yields greater than 80% increases as the CR and the reflectivity of both facets increases.