Pullout Characteristics of Waste Fishing Net Reinforced Bottom Ash using Pullout Test (인발시험에 의한 저회에 보강된 폐어망의 인발특성 연구)

  • Kwon, Soon-Jang;Kim, Yun-Tae
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.4
    • /
    • pp.57-66
    • /
    • 2013
  • In this study, pullout tests were carried out to evaluate pullout characteristics of waste fishing net (WFN), which added into bottom ash for recycling both bottom ash and WFN. Three different mesh size of WFN (WFN20:$20mm{\times}20mm$, WFN30:$30mm{\times}30mm$, WFN40:$40mm{\times}40mm$) and geogrid were added as a reinforcement. Pullout characteristics of waste fishing net were compared with those of the geogrid. Pullout test results showed that pullout strength and stiffness of WFN20 are a little less than those of geogrid. However, the pullout friction angle of WFN20 is similar to that of geogrid due to bearing resistance induced from transverse rib because thickness of WFN20 is greater than geogrid. Pullout test results also indicated that distribution of residual strain along reinforcement after test depends on overburden stress. Residual strain at the tip of reinforcement increased with an increase in overburden stress due to concentration of pullout force on the tip of reinforcement.

Variation of Pull-out Resistance of Geogrid with Degree of Saturation of Soil

  • Yoo, Chungsik;ALI, TABISH
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2020
  • This paper presents the results of experimental investigation on the effect of degree of saturation of soil on the pullout behavior of a geogrid. Different test variables were taken into account while performing the experiment including the soil physical conditions based on water content and external loading applied. The soil used was locally available weathered granite soil. The tests included variations in saturation of about 90%, 80%, 70% and 45% (optimum moisture content). The pullout tests were performed according to ASTM standard D 6706-01. The results indicate that increasing the degree of saturation in the soil decreases the pull-out capacity, which in turn decreases the interface friction angle and interaction coefficient. The decrease in the pullout interface coefficient was observed to be around 12.50% to 33.33% depending on the normal load and degree of saturation of the soil. The test results demonstrated the detrimental effect of increasing the degree of saturation within the reinforce soil on the pullout behavior of reinforcement, thus on the internal stability. The practical inferences of the outcomes are analyzed in detail.

Improvement in uplift capacity of horizontal circular anchor plate in undrained clay by granular column

  • Bhattacharya, Paramita;Roy, Anamitra
    • Geomechanics and Engineering
    • /
    • v.10 no.5
    • /
    • pp.617-633
    • /
    • 2016
  • A numerical study has been conducted to examine the improvement achieved in the ultimate pullout capacity of horizontal circular anchor plates embedded in undrained clay, by constructing granular columns of varying diameter over the anchor plates. The analysis has been carried out by using lower bound theorem of limit analysis and finite elements in combination with linear programming. The improvement in uplifting capacity of anchor plate is expressed in terms of an efficiency factor (${\xi}$). The efficiency factor (${\xi}$) has been defined as the ratio of ultimate vertical pullout capacity of anchor plate having diameter D embedded in soft clay reinforced by granular column to the vertical pullout capacity of the anchor plate with same diameter D embedded in soft clay only. The variation of efficiency factor (${\xi}$) for different embedment ratios and different diameter of granular column has been studied considering a wide range of softness of clay and different value of soil internal friction angle (${\phi}$) of the granular material. It is observed that ${\xi}$ increases with an increase in diameter of the granular column ($D_t$) and increase in friction angle of granular material. Also, the effectiveness of the usage of granular column increases with decrease in cohesion of the clay.

The Evaluation for Pullout Performance of Steel Strip Reinforcements with Deformed-Bars as Transverse Members (지지부재로 이형철근을 설치하는 띠형 강보강재의 인발성능 평가)

  • Jung, Sung-Gyu;Kim, Juhyong;Cho, Samdeok;Lee, Kwangwu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.4
    • /
    • pp.77-86
    • /
    • 2013
  • Laboratory pullout tests were conducted to evaluate pullout performance of steel strip reinforcements with deformed steel bars as transverse members. The steel strip reinforcement has an installation hole to assemble a deformed steel bar. Jumunjin standard sand is used to form a relative density of ground model to 80%. Frictional resistance of steel strip reinforcement without transverse member increases sharply at the initial displacement and quickly decreases with displacement. Maximum frictional resistance increases linearly as normal pressure increasing, and soil-reinforcement interaction friction angle(${\rho}_{peak}$) of a steel strip reinforcement is estimated to $14.64^{\circ}$. Passive resistance increases with displacement and converge into maximum passive resistance in most cases. Maximum passive resistance increases linearly as normal pressure increasing irrespective of shape of the steel reinforcement. Pullout force of steel strip reinforcements with installation holes or transverse members largely increases about 4 to 7 times compared to frictional resistance force of steel strip reinforcements when embedment length($L_e$) of steel strip reinforcements is 500 mm. In the case of using 2 transverse members, interference effect is observed due to the spacing of 2 transverse members and location of assembly holes and transverse members.

Friction Features of Geosynthetics Through the Pullout Test (인발실험을 통한 토목섬유의 마찰특성 평가)

  • Shin, Eun-Chul;Yun, Sock-Ho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.2 no.1
    • /
    • pp.3-13
    • /
    • 2003
  • Recently, construction of the reinforced earth structures, which adopts reinforcing materials of geosynthetic, is rapidly increasing due to its good economic advantages, beautiful appearance, and convenient construction. Nonetheless, the most important factor of interpretation and design of the reinforced earth structures, which is assessment ways of friction features between earth and geosynthetic, has not been standardized yet. It has great difference of interpretation and design methods which suggested to the design engineer. This study is to present the way how to assess more reasonably friction features between geogrid and weathered granite soil through the pullout test. Based on a large-scale pullout test of geogrid, the maximum shear stress, interface fricton angle, and friction efficiency are presented with consideration of various test condition.

  • PDF

Evaluation of Geogrid-Reinforced Track substructure Effectiveness Using A Large-Scale Pullout Device (대형인발시험기를 이용한 지오그리드로 보강된 궤도하부구조층의 효율성 평가)

  • Oh, Jeongho
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.1
    • /
    • pp.40-48
    • /
    • 2014
  • A number of attempts has been made to reinforce ballasted track substructure to meet the requirement of high-speed operation and effective rehabilitation of existing railroads. For the purpose of this, the use of geogrid has been applied, and the benefit of its use has been recognized via previous studies. In this study, an experimental pullout test was carried out to investigate the influence of normal stress on pullout strength of geogrid using different types of soil and geogrid. The results revealed that the pullout resistance generally tends to increase proportional to normal stress while the pullout coefficient interaction decreases, which is a function of material interface properties, such as the friction angle of soil, and interlocking condition between soil and geogrid. In addition, a methodology based on work-energy concept was proposed to evaluate effectiveness of geogrid and limitedly verified using test results.

Analysis of Shear Resistance Characteristics in Pile-Soil Interface using Large-Scale Direct Shear Test (대형직접전단시험을 통한 말뚝과 지반 경계면의 전단특성 분석)

  • You, Seung-Kyong;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.3
    • /
    • pp.61-69
    • /
    • 2022
  • In this study, a large-scale direct shear test was performed to evaluate the shear characteristics of the pile-soil interface according to the fines content and confining pressure conditions as a reasonable evaluation method of the pullout resistance performance of pile considering the soil conditions. It was found that the shear stress was greatly generated under the conditions of high normal stress and low fines content. In addition, the maximum shear stress was found to be rather large under the conditions of the same normal stress and fines content, when pile surface had high roughness. The internal friction angle decreased at the pile-soil interface, when the fines content in the ground increased. On the other hand, the cohesion decreased under the condition of high fines content. And the internal friction angle and cohesion were large regardless of the fines content in the model ground, when the roughness of the pile surface was high.

Pullout Behavior of Mechanically Stabilized Earth Wall Abutment by Steel Reinforcement and Backfill Properties (금속 보강재와 채움재 특성에 따른 보강토교대의 인발거동 분석 연구)

  • Kim, Taesu;Lee, Soo-Yang;Nam, Moon S.;Han, Heuisoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.750-757
    • /
    • 2018
  • The mechanically stabilized earth wall abutment is an earth structure using a mechanically stabilized earth wall and it uses in-extensional steel reinforcements having excellent friction performance. In order to analyze the pullout behavior of in-extensional steel reinforcements usually applied on the mechanically stabilized earth wall abutment, effects of stiffness and particle-size distributions of backfills and also horizontal spacings were considered in this study. As a result of parametric analyses, the highest pulling force acted on the uppermost reinforcement, and the stiffness and the particle-size distributions of the backfill significantly affected the pulling resistance of the reinforced soils. The internal friction angle of backfills should be at least 25 degrees, the coefficient uniformity factor should be at least 4, and the horizontal spacing of the uppermost steel reinforcement should be less than 25cm. Therefore, in order to secure the pullout resistance of the reinforced soil, it is necessary a properly spacing of reinforcement and more strict quality control for the backfill.

Application of direct tension force transfer model with modified fixed-angle softened-truss model to finite element analysis of steel fiber-reinforced concrete members subjected to Shear

  • Lee, Deuck Hang;Hwang, Jin-Ha;Ju, Hyunjin;Kim, Kang Su
    • Computers and Concrete
    • /
    • v.13 no.1
    • /
    • pp.49-70
    • /
    • 2014
  • Steel fiber-reinforced concrete (SFRC) is known as one of the efficient modern composites that can greatly enhance the material performance of cracked concrete in tension. Such improved tensile resistance mechanism at crack interfaces in SFRC members can be heavily influenced by methodologies of treatments of crack direction. While most existing studies have focused on developing the numerical analysis model with the rotating-angle theory, there are only few studies on finite element analysis models with the fixed-angle model approach. According to many existing experimental studies, the direction of principal stress rotated after the formation of initial fixed-cracks, but it was also observed that new cracks with completely different angles relative to the initial crack direction very rarely occurred. Therefore, this study introduced the direct tension force transfer model (DTFTM), in which tensile resistance of the fibers at the crack interface can be easily estimated, to the nonlinear finite element analysis algorithm with the fixed-angle theory, and the proposed model was also verified by comparing the analysis results to the SFRC shear panel test results. The secant modulus method adopted in this study for iterative calculations in nonlinear finite element analysis showed highly stable and fast convergence capability when it was applied to the fixed-angle theory. The deviation angle between the principal stress direction and the fixed-crack direction significantly increased as the tensile stresses in the steel fibers at crack interfaces increased, which implies that the deviation angle is very important in the estimation of the shear behavior of SFRC members.

Friction Angle on the Surface of Vertical Ground Anchor in Sand (모래지반내의 연직 지반앵커 표면의 마찰각)

  • 임종철
    • Geotechnical Engineering
    • /
    • v.11 no.4
    • /
    • pp.99-110
    • /
    • 1995
  • In this study, friction angles on the surface of vertical rigid ground anchor in normally consolidated dry sand were measured by model pullout tests in laboratory. Friction angles were obtained from the normal and shear stresses measured along depth of the anchor stir face by attaching several 2-dimensional load cells. Model tests were conducted under the plane strain state and axial symmetric state. From the results of tests, it was concluded that the maximum friction angle on the anchor surface coincides nearly with the maximum angle of stress obliquity on the plane of zero-extension direction obtained by plane strain compression test. This result was made with regard to the strength anisotropy and stress dependency of sand. It showed that when angle of shear resistance of the sand is applied to the friction angle of the anchor surface, the design capacity could be less than the applied force, thus making the anchor unsafe.