• Title/Summary/Keyword: Pull test

Search Result 586, Processing Time 0.038 seconds

Pull-out Resistance Behavior of the Anchor with the Bump Type Resistors (돌기형 저항체를 설치한 앵커의 인발저항거동)

  • You, Min-Ku;Lee, Sang-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.11
    • /
    • pp.35-43
    • /
    • 2017
  • In this study, the pull-out resistance behavior of the anchor with the bump type resistors at the anchor body was experimentally investigated. In the model tests, the pull-out resistance was measured by pulling out the anchor at a constant speed. Anchor body was installed in the center of the circular sand tank. Pull-out tests were conducted for 10 conditions. The anchor type (existence of the resistor), the friction conditions of the anchor body surface ($1/3{\phi}$, $2/3{\phi}$, ${\phi}$), the bump type resistor set number (1set, 2set, 4set), and the height of resistors (0.05d, 0.10d, 0.20d) were varied. The load-displacement relationship for each conditions was measured during the pull-out tests at a constant speed (1 mm/min). Maximum pull-out length was 80 mm. As a result, the pull-out behavior of the friction type anchor and the expansion type anchor was different. As the number of resistor increased, the maximum pull-out resistance increased and the residual pull-out resistance ratio increased significantly, which were at 171~591 percent larger than that of the friction type anchor.

Characteristics of Asphalt Concrete Mixed with Polyethylene Aggregate (폐비닐 골재 혼합 아스콘의 성질)

  • Kim, Youngchin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.12
    • /
    • pp.5-11
    • /
    • 2017
  • The 19 mm-sized aggregate was produced by melting vinyl waste (waste polyethylene film) generated from vinyl greenhouses in rural areas. It was mixed with As'cone at various weight ratios, and then insulation effect test, tension test after repeated freezing and thawing, ice pull-out strength test and field density test were conducted for the mixtures. These results demonstrated that as the mixing ratio of polyethylene aggregate increased, the insulation effect increased, due to the many pore spaces that existed in the polyethylene aggregate. After repeatedly freezing and thawing As'cone, the tensile strength significantly increased at 2.5% of the polyethylene aggregate content rather than 0% of polyethylene aggregate content but it also slightly decreased at 5% and 10% of polyethylene aggregate content in comparison to 2.5% of its polyethylene aggregate content. As'cone added with polyethylene aggregate by 2.5% resulted in lower ice pull-out strength than that of normal As'cone. As a result of the porosity test for the samples taken at the site, porosity of the As'cone, which added polyethylene aggregate, was smaller than that of the general As'cone.

Evaluation of Long-Term Behaviors of the Cone Nailing System using Geotechnical Centrifuge Guidelines (원심모형실험을 이용한 방추형 콘 네일링 시스템의 장기거동 특성 평가)

  • Park, Si-Sam;Bae, Woo-Seok;Jung, Woo-Chul;Kim, Hong-Taek;Kim, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.744-751
    • /
    • 2006
  • In case of the Soil Nail System applied to a slope, effects of vibrations from blasting, earthquake and creep of long term behaviors cause reductions of adhesion between grout and soil-nail. There are some reports of nail's pull-out failure by those reasons. In this paper it is suggested that the Cone Nailing System is enable to diminish effects of vibrations and creep. In this study on Cone Nailing System, the cones are installed to each nail by 2m. By such installing cones, the adhesion between nail and grout will increase and the long term creep behavior will decrease. In this study, the centrifuge test is performed to understand the behaviors of the Cone Nail System. For the centrifuge test, the soil tank is 52cm in width, 17cm in length and 35cm in height. In comparison with general soil nail, the centrifuge test of general soil nail(without cone) is performed equally. Additionally, the interface between cone nail and soil through the pull-out test is applied to FLAC 2D version 3.3. and the evaluation of application for the Cone Nail System in slope is performed.

  • PDF

Evaluation of Skin Friction Using Tensile Load Testing of CPR Piles (CPR 말뚝의 인발재하시험을 통한 주면마찰력 평가)

  • Ko, Chin-Surk;Kim, Jung-Han;Noh, Jeongdu;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.30 no.1
    • /
    • pp.59-69
    • /
    • 2020
  • Pull-out load tests were performed on a CPR (Compaction grouting compound Pile with Reinforce) test pile, with skin friction being evaluated by the yield load and allowable bearing capacity after analyzing load-displacement curves and load-settlement curves. Results of the CPR test piles analyzed from the load-displacement curves show that the yield load and allowable bearing capacity of the large-diameter CPR test pile were about 1.4 times larger than that of the small-diameter pile. Results of the load-settlement curves reveal that the allowable bearing capacity of the CPR test pile with diameter of D500 was 1.2~2.1 times greater than that of the pile with diameter of D400. However, the allowable bearing capacity calculated using Fuller's analysis differed substantially from that determined using the P (Pull-out load) - S (Settlement) and log P - log S curves. Therefore, calculation of the allowable bearing capacity using Fuller's analysis is shown to be inappropriate.

Bonding Strength of bonded Polymer Concrete on Cured Cement Concrete (경화된 콘크리트에 접착된 폴리머 콘크리트의 부착강도 특성)

  • 홍승호;권순민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.353-358
    • /
    • 2001
  • The cement concrete pavements are designed twenty years of performance life in Korea. At the present time, some expressways have been elapsed seventy percent of performance life which are detecting local failures. The most repair methods using to repair failures are partial depth repair and full section repair. These methods are most important bonding strength between rapid curing materials and substrate concrete pavements. This study was performed to evaluate bonding strength of the composites section made of rapid curing material and substrate concrete pavements. The pull-out tester was used to test bonding strength for the composites section made of each materials. In the results of the test, the bonding strength values of the epoxy mortar and acrylic mortar are higher than those of the other materials. The performance life of repaired section is affected by various factor. The bonding strength of bonded composites section may be affect the performance life, significantly.

  • PDF

A Experimental Study on the Friction Characteristics of the Fiber Glass Geogrid (유리섬유 지오그리드의 마찰특성에 관한 실험연구)

  • 채영수;박연준;유광호;송신석;강승문
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.496-503
    • /
    • 2000
  • The friction between soils and the geosynthetics varies depending upon the types and characteristics of the involved materials. Many engineers have studied the frictional characteristics between the two materials in may way but the results obtained so far is not satisfactory. In this study the frictional characteristics between the soil and the geogrid were examined through laboratory direct shear test and pull-out test. Tests were conducted on two different types of geogrid: Polyester grids(PET) which are currently used and newly developed fiber-glass grids(FG). Result showed that FG grid yielded smaller displacements and uniform displacement distribution mainly due to much higher stiffness. Therefore, it is expected that more efficientbfl support and displacement control can be achieved by the FG grid.

  • PDF

Tensile Fracture Behavior of Glass Fiber/Polypropylene Composites for Various Fiber Volume Fraction (섬유함유율에 따른 GF/PP 복합재료의 인장파괴거동)

  • Koh, Sung-Wi;Um, Yoon-Sung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.2
    • /
    • pp.161-165
    • /
    • 2004
  • The main goal of this work is to study the effect of glass fiber volume fraction on the result of tensile test with respect to glass fiber/polypropylene(GF/PP) composites. The tensile test and failure mechanisms of GF/PP composites were investigated in the fiber volume fraction range from 10% to 30%. The tensile strength and the fracture strength increased with the increasing of the fiber volume fraction in the tested range. Fiber pull-out and debonding of this composites increased with the fiber volume fraction in thc tested range. The major failure mechanisms were classified into the debonding, the fiber pull out, the delamination and the matrix deformation.

Test Pattern Generation for Detection of faults in BiCMOS Circuits (BiCMOS 회로의 고장 검출을 위한 테스트 패턴 생성)

  • Shin, Jae-Heung;Lee, Byung-Hyo;Kim, Il-Nam;Lee, Bok-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.113-116
    • /
    • 2003
  • BiCMOS circuit consist of CMOS part which constructs logic function, and bipolar part which drives output load. In this paper, proposes a method for efficiently generating test pattern which detect faults in BiCMOS circuits. In proposed method, BiCMOS circuit is divided into pull-up part and pull-down part, using structural property of BiCMOS circuit, and we generate test pattern using set theory for efficiently detecting faults which occured each divided blocks.

  • PDF

Laser Soldering and Inspection of the Solder Joint (레이저 솔더링과 접합부 평가)

  • 한유희;김인웅;방남주
    • Laser Solutions
    • /
    • v.2 no.1
    • /
    • pp.38-42
    • /
    • 1999
  • As very large scale integration technology has been developed, much more accurate, reliable technology is needed for outer lead bonding. Laser soldering has been researched as an alternative for fine pitch device bonding. This study is focused on how to select optimal laser soldering variables with which solder wets parent material, the microstructural results of laser soldering and the reliability test One of popular packages, QFP100 was soldered successfully with two kinds of solder. The inspection of the joint for reliability was carried out by optical microscope, SEM, EDAX and pull test, which demonstrated the superiority of laser soldering.

  • PDF

Extraction of Proper Mixture Ratio of SDS Solution as the Substitute of Soapy Water in a Slip Test (미끄럼시험에서 비눗물을 대체하기 위한 SDS 수용액의 적정 혼합비율 도출)

  • Kim, Dae-Kyu;Shin, Yun-Ho;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.83-84
    • /
    • 2016
  • For the slip resistance test of shower room floor, the "O-Y Pull Slip Meter method (O-Y·PSM)" regulated under KS M 3510. This test method uses cooking oil as a substitute of soapy water, and thus it does not reflect the real condition. In this study, on 10 types of floor material samples, the Coefficient of Slip Resistance Bath (CSR·B) on bare foot between 10 types of body wash solution and 6 types of SDS solution was compared. The body wash solution is a mixture of soap and water in 1:20 ratio. As a result, SDS 0.1% solution was the most suitable for a substitute of soapy water in shower.

  • PDF