• Title/Summary/Keyword: Public facility

Search Result 1,214, Processing Time 0.03 seconds

A Study on Evaluation Plan of Fire Safety Performance for Public Building (공동주택의 화재안전성능 평가방안에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2019
  • From the viewpoint of fire-fighting activities, public building have structural and management problems in fire, so evacuation disturbance and risk of expanding combustion are high. As a result of analyzing various fire fragile factors of public building, The evaluation areas were derived from safety systems, fire-fighting facility, structure safety, general safety and the evaluation factors were presented. Also, the characteristics of domestic and foreign certification systems were analyzed by comparing and analyzing the status of fire safety performance certification system for 6 domestic and overseas apartment houses. In conclusion, the 5 convergence directions of certification system and 22 evaluation items by 4 evaluation fields were derived, and based on this, we have established 3 convergence introduction plans of fire safety performance certification system of public building.

Utilities Market: The Sphere of Protection of Subjects

  • Dzhumageldiyeva, Gulnara;Zablodska, Inna;Yukhymenko-Nazaruk, Irina;Dovgaliuk, Vita;Suprunova, Irina;Gylka, Ulyana
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.3
    • /
    • pp.266-274
    • /
    • 2021
  • The study covers three components of the facility for protecting public utilities market participants in the public utilities market: prevention of potential poverty, reduction of existing poverty and compensation to the injured party in a case of tort that exacerbates or threatens to exacerbate its poverty. The analysis is based on official statistical information on the activities of the public utilities sector. Operational information of public utility service providers regarding certain indicators of their activity in the work was not studied. This approach narrows the empirical basis of the study, but at the present stage in the context of different rates of implementation of changes in regions, sectors and at the level of individual entities, as well as lack of uniformity in the structure of indicators published by service providers, analysis allows to identify «bottlenecks» of legal regulation, which are systemic in nature and largely independent of the subjective factor.

Associations between Use of Single-Parent Facility Programs and Public Support Programs and the Mental Health for Adolescent Single-Parent (청소년 한부모의 입소시설 프로그램 및 한부모가족 정책사업 수혜경험과 정신건강과의 관련성 탐색)

  • Lee, Yoon-Jung
    • Journal of Families and Better Life
    • /
    • v.35 no.2
    • /
    • pp.93-112
    • /
    • 2017
  • The adolescent birth rate has doubled in the recent decade. As a result, the Korean government has implemented support for adolescent single-parent families by expanding the scope of coverage of the Single-parent Family Support Act in 2010. In order to understand whether experiences of facility entry programs and the Single-parent Family Support Act for adolescent single-parents were helpful or not, this study verified the relationship to mental health. This study utilized a part of the National Youth Policy Institute's 'Research on the Actual Condition of the Adolescent Pregnancy, Birth and Rearing Children.' Participants of the study were 218 adolescent single-parents at the age of 24 and younger. This study used the research methods of descriptive statistical analysis, ${\chi}^2$test, t-test, and one-way analysis of variance. The findings and discussion of this study are as below: Firstly, the depression level of adolescent single-parents who had been raised by grandparents was higher than other family types to a meaningful standard and adolescent single-parent's cognition of the original family's economic level was related to self-esteem and parenting efficacy. Secondly, the practical single-parent family support policy for adolescent single-parent's pregnancy, birth and rearing children has shown a higher reception rate, and medical service of facility entry programs has a higher satisfaction level. However, some of the facility entry programs and the Single-parent Family Support Act have a low reception rate and it should be considered whether to maintain them or not.Lastly, parts of facility entry programs and the Single-parent Family Support Act for adolescent single-parents have increased self-esteem and parenting efficacy and reduced parenting stress and depression's levels.

Improvement Direction of Facility Management System(FMS) through Related Systems Analysis (유관 시스템 분석을 통한 시설물정보관리종합시스템 개선방향)

  • Jung, In-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6751-6758
    • /
    • 2015
  • The Special Act on Safety Control for Infrastructure was enacted in 1995 to contribute to ensuring the public safety and welfare improvement of Korean people. In addition, the FMS has been developed and operated to manage facilities effectively. However, several problems of the FMS have also occurred. Thus, this study aimed to analyze the FMS and related systems scrutinizingly to suggest improvement directions such as (1) extension of the FMS into the national facility information management system including small-size facilities other than Types 1 and 2 facilities, (2) development and promote standardized inspection and diagnosis systems as per facility type, (3) development of the database utilization system including decision making support function for management body, and (4) providing the FMS performance improvements and stable operating environment utilizing latest information technologies. If the improvement directions suggested in this study are adopted, they can improve services for Korean people by providing facility safety and maintenance work parties with optimum information services.

Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings (다중이용시설에서의 실내공기중 미생물 분포에 관한 연구)

  • Kim Yoon Shin;Lee Eun Gyu;Yup Moo Jong;Kim Key Young
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.1
    • /
    • pp.85-92
    • /
    • 2002
  • A measurement of indoor microorganism using Reuter Centrifugal Air Sampler(RCS) was undertaken during October 1991 - February 1999 and 6-Stage Cascade Air Sampler was undertaken during May 2001 - June 2001 in Seoul. Sites including book store, department store, theater, subway station, underground shopping center, hospital, office building, sports facility, and eduationa institutio were chosen to measure indoor microorganism. The results were as follows: 1. The average of total microorganism collected on the agar strip GK-A media were, in the order, subway station, hospital, underground shopping center, department store, book store, theater, sports facility, educational institution, office building in sites. The highest concentration of 711cfu/m$^3$ was found in the subway station and the lowest concentration of 44cfu/m$^3$ was found in office building. 2. The average of staphylococci collected on the agar strip GK-S media, in the order, were subway station, underground shopping center, hospital and department store, department store, theater, office building, sports facility and educational institution in sites. The highest concentration of 502cfu/m$^3$ was found in the subway station and the lowest concentration of 14cfu/m$^3$ was found in sports facility and educational institution. 3. The average of fungus collected on the agar strip GK-HS media, in the order, were underground hospital, shopping center, theater, subway station, department store, book store, sports facility, educational institution, and office building in sites. The highest concentration of 252cfu/m$^3$ was found in the hospital and the lowest concentration of 32cfu/m$^3$ was found in office building. 4. Ratio of Indoor/Outdoor, determined by site was 1.12-2.38 in total count, 1.00-2.35 in staphylococci, and 0.99-1.34 in fungus. 5. The positive results of test were 12-24% in indoor and 9-43% in outdoor. 6. By gram staining gram positive cocci were 59.9%, gram positive bacill 24.4%, gram negative bacilli 10.4%, and gram negative cocci 0.5%.

The Policy Proposal for Selecting Facility-stems of Rural Living Environment Renewal Program (농촌생활환경정비 대상 시설항목의 선정: 정책적 제안)

  • 윤원근;이상문
    • Journal of Korean Society of Rural Planning
    • /
    • v.4 no.2
    • /
    • pp.8-19
    • /
    • 1998
  • The problem of outdated and surplus facility-items in existing Rural Living Environment Renewal Program(RLERP) makes this study focus on restricting the range of facility sorts for the purpose of coㅁins with the changing rural living environment. In the four aspects of plan establishment, project implementation, comprehensiveness and linkage between programs, this study made an analysis of the existing RLERP that has 4-stage hierarchy, namely, Gun(county), Myun(primary administrative district), village and project site level Firstly, Myun and upper level policy programs fulfill the comprehensiveness and planning aspects, but have defects in the implementation and linkage aspects. Secondly, the village level programs satisfies more or less the four condition, but give rise to the problems of equity between the project target village and the non-target, and of generalization of the planning method applying to a specific village. At last, project level programs, controlled by several ministries, have defects in comprehensiveness and linkage aspects, exposing the sectoralism of central government. Above all, the existing RLERP has so many facility items, which have led to inefficient investment till now. Therefore, it's necessary that the environmental facilities should be selected(simultaneously reduced ), referring to following 5 criteria. (1) Exception of facilities relating to agricultural production. (2) Confined to public facilities to be constructed by government support. (3) Common-use facilities located in small town and below level area. (4) Consideration of not only the present need but also the future need of rural residents. (5) Reflection of a regional difference of mountain, plane and suburban area. Just 13 kinds of living environmental facilities are finally selected as the result of the selecting work, which can be an new alternative for RLERP. Concludingly, the selected facility items should be integrated into a designated project site by the prepared plan in order to enhance the efficiency of RLERP, investment and also to satisfy the four analytic aspects mentioned above.

  • PDF

Basic Study for User-centered Kindergarten Planning and Design Standards -Focusing on Case Studies and Advice- (사용자 중심의 단설 유치원 계획 및 설계기준을 위한 기초연구 -사례조사와 자문의견을 중심으로-)

  • Meang, Joon-Ho;Kim, Sung-Joong;Song, Byung-Joon;Kim, Jae-Young
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.20 no.4
    • /
    • pp.1-12
    • /
    • 2021
  • This study aims to propose a planning direction based on the results of domestic case studies and expert advice as a basic research to establish a specific implementation model for kindergarten education space in response to changes in future society and future education by escaping from the issues and facility limitations of existing kindergarten education space. To this end, it is intended to contribute to the positive effect of future education policies by being used as basic data for building specific implementation models through review of the 'Nuri' course, domestic case analysis, and revision of specific standards for kindergarten facility planning. The main research results were case analysis and advisory consultations to derive facility standards and planning directions divided into layout plans, general classrooms, support facilities, public spaces, and external spaces, and a process for identifying and systematizing space-influencing factors based on the facility standards derived in this basic study is needed hereafter.

Radiological Assessment of Environmental Impact of the IF-System Facility of the RAON

  • Lee, Cheol-Woo;Whang, Won Tae;Kim, Eun Han;Han, Moon Hee;Jeong, Hae Sun;Jeong, Sol;Lee, Sang-jin
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.2
    • /
    • pp.58-65
    • /
    • 2021
  • Background: The evaluation of skyshine distribution, release of airborne radioactive nuclides, and soil activation and groundwater migration were required for radiological assessment of the impact on the environment surrounding In-Flight (IF)-system facility of the RAON (Rare isotope Accelerator complex for ON-line experiment) accelerator complex. Materials and Methods: Monte Carlo simulation by MCNPX code was used for evaluation of skyshine and activation analysis for air and soil. The concentration model was applied in the estimation of the groundwater migration of radionuclides in soil. Results and Discussion: The skyshine dose rates at 1 km from the facility were evaluated as 1.62 × 10-3 μSv·hr-1. The annual releases of 3H and 14C were calculated as 9.62 × 10-5 mg and 1.19 × 10-1 mg, respectively. The concentrations of 3H and 22Na in drinking water were estimated as 1.22 × 10-1 Bq·cm-3 and 8.25 × 10-3 Bq·cm-3, respectively. Conclusion: Radiological assessment of environmental impact on the IF-facility of RAON was performed through evaluation of skyshine dose distribution, evaluation of annual emission of long-lived radionuclides in the air and estimation of soil activation and groundwater migration of radionuclides. As a result, much lower exposure than the limit value for the public, 1 mSv·yr-1, is expected during operation of the IF-facility.

Comparing Stakeholder Perceptions on the Reasons for Rural Underutilization of Common Facilities (농촌지역 개발사업 공동시설의 활용도 기준체계 정립을 통한 실태 파악 연구)

  • Kim, Eun-Sol;Lee, Jae Ho
    • Journal of Korean Society of Rural Planning
    • /
    • v.29 no.3
    • /
    • pp.53-67
    • /
    • 2023
  • In this study, the problem of the idleness of public buildings in rural areas is seriously emerging, but there are no clear standards for assessing the utilization of these buildings. Therefore, this study endeavors to investigate the actual state of idleness of buildings created by rural area development projects based on the criteria for each type. As part of this study, rural facilities were selected in two locations in Sangju City and Miryang City among the target areas of the Rural Agreement. Utilization evaluation criteria were developed to identify the conditions of underutilization. In order to determine the utilization pattern for each facility type, an in-depth interview with the operator and an inspection of the facility were conducted. Based on the analysis, the degree of utilization (e.g., low use, non-use, etc.) was different for each facility type, and among the four facility types (rural tourism, culture and welfare, exercise and recreation, income-based), rural tourism was rated as the least efficient. It has been found that the operating entity's capacity has a significant influence on the utilization of facilities. Socioeconomic factors, such as a decrease in utilization rates, are greatly influenced by the operating entity's capacity. Therefore, support from local governments as well as the national level is required to recycle idle facilities. Lastly, this study suggests the need for different standards for utilization, depending on the type of facility. This moves beyond checking the degree of idleness by the same standard that was previously implemented.

Development of underground facility information collection technology based on 3D precision exploration (3차원 정밀탐사 지하시설물 정보 수집 기술 개발)

  • Jisong RYU;Yonggu JANG
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.4
    • /
    • pp.56-66
    • /
    • 2023
  • Safety accidents are increasing, such as changes in groundwater levels due to construction work or natural influences, or ground cave-ins caused by soil runoff from old water supply and sewage pipes. In addition, underground facility management agencies must make efforts to improve the accuracy of underground information through continuous investigation and exploration in accordance with the Special Act on Enhanced Underground Safety Management. Accordingly, in this study, we defined the configuration of equipment and data processing method to collect 3D precise exploration underground facility information and developed 3D underground facility information collection technology to ensure accuracy of underground facilities. As a result of verifying the developed technology, the horizontal accuracy improved by an average of 6cm compared to the existing method, making it possible to acquire 3D underground facility information within the error range of the public survey work regulations.