• Title/Summary/Keyword: Public Drinking Water

Search Result 199, Processing Time 0.023 seconds

Studies on the Mineral Water in Seoul Area (서울시 일원 약수의 수질에 관한 조사연구)

  • Choi Han-Young
    • Journal of environmental and Sanitary engineering
    • /
    • v.3 no.1 s.4
    • /
    • pp.69-74
    • /
    • 1988
  • This study was carried out to investigate water quality and pollution in the mineral water located in Seoul area. 15 sites were pointed out by random sampling and tested monthly for 14 items from July to December in 1986. 1. 14 sites were suitable for the drinking water standards but 1 site was not suitable for its pH (5.4). 2. The range of mineral element and concentration were as follows: $$K\;(1.1\pm0.19\~2.38\pm0.45ppm)$$ $$Na\;(5.14\pm0.32\~11.2\pm0.58ppm)$$ $$Ca\;(4.36\pm0.53\~14.44\pm0.53ppm)$$ $$Mg(1.58\pm0.32\~6.34\pm0.77ppm)$$ 3. Among the heavy metals, Fe, Zn, Mn, Cu, were detected small amount but Pb was not detected in all sample. 4. Fluoride concentrations were the range of $0.13\pm0.03\~0.42\pm0.03ppm$.

  • PDF

Cryptosporidium and Giardia (oo)cysts in Korean Rivers and the Effect of Sample Matrix (국내 주요 수계 내 원생동물의 분석과 매질의 영향)

  • Chung, Hyenmi;Oh, Dukwha
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.271-276
    • /
    • 2006
  • The outbreak cases of Cryptosporidium or Giardia from drinking water in abroad have drawn attentions on the public health. It is well known that Cryptosporidium is the most resistant organism against chlorine disinfection. To guesstimate the levels of Cryptosporidium and Giardia in Korean surface water, 1~2 samples from 22 drinking water sources in four Korean major rivers of Han, Keum, Nakdong, and Youngsan were monitored. In addition, two sites in Kyunganchon, a contaminated river were monitored for comparison. In source waters, detection rates of Cryptosporidium and Giardia were 15% (6/39) and 21% (5/24) with the range of 1~3 oocysts/10 L and 1~6 cysts/10 L, respectively. In Kyunganchon, they were 60% (6/10) and 70% (7/10) in the range of 1~9 oocysts/10 L and 10~72 cysts/10 L, respectively. When one of the source waters in Han river was monitored monthly, Cryptosporidium were found mostly in cold season. Matrix of the samples gave influence on the recoveries of the spiked protozoa. The recoveries of both Cryptosporidium and Giardia increased in the samples of Kyunganchon, known as contaminated area. However, protozoan recovery did not show significant relation with turbidity, the index of matrix contamination, which implies that there are additional unveiled features of matrix affecting the recoveries of the protozoa. The protozoan distribution in Kyunganchon showed significant relations with Cl. perfringens, anaerobic and spore forming indicator bacteria of fecal contamination by regression analysis, but not with turbidity, the general indicator of water quality.

The Dynamic Modeling of Conflicting Issues in Public Organization : The System Simulation of Dynamic Interaction Between Environmental System and Regional Development System. (조직의 상충적 이슈에 관한 동태적 모델링 : 환경 시스템과 경제 시스템 간의 동태적 상호작용 분석과 시스템 시뮬레이션)

  • 홍민기
    • Korean System Dynamics Review
    • /
    • v.1 no.1
    • /
    • pp.159-183
    • /
    • 2000
  • How to protect the environment without sacrificing the human environment and economy at the level of region is on of the most difficult issues of recent times. The dynamic Interactions between economic activities and environmental pollution control activities determine whether social welfare is increased of decreased by such activities and provides a basis for saying whether they help or hurt the economy. Bureaucratic Approach of Local government has failed, and an Impetus has arisen to develop new tools of analysis, useful for finding policy leverages focused on sustainability. This paper focus on understanding dynamic relationships between regional economic system and environmental system, and presenting possible framework for finding policy leverages in dynamic interaction behaviors. The case, selected in this study, is Nacdong river regions case, which is related many meaningful issues about sustainable development: two big metropolitan government and dwellers have different opinion with regard to construction of large scale Industrial pack, drinking water supply, and environment model consisting of three sectors: regional economy sector, river pollution and drinking water sector, environmental protection and investment policy sector Finally, this paper deal with how to link policy leverage to causal loop structure for the sustainable development of two regions.

  • PDF

Water quality analyses between tap water and treated water by point-of-use water dispenser systems (정수기 공급수인 수돗물과 정수기 통과수의 수질차이 분석)

  • Park, Keun-Young;Park, Ji-Won;Kim, Jae-Hyeok;Na, Yeong;Maeng, Sung-Kyu;Kim, Sung-Pyo;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.395-404
    • /
    • 2019
  • The point-of-use water dispenser systems are widely used because of convenience in handling and demand for high-quality drinking water. The application has been increased recently in the public places such as department stores, universities and the rest areas in express ways. Improvement of water qualities by the dispenser systems was compared with tap water in this study. The tap water is supplied to the dispenser as the influent of the dispenser system. The twelve dispensers in the public places were used. The five dispensers used reverse osmosis as the main filter and other dispensers used various filters such as ultrafiltration, nanofiltration, and alumina filter. The water quality indicators for sanitation safety, i.e., turbidity and total coliforms, were evaluated. Other water qualities such as pH, residual chlorine, heterotrophic plate count (HPC), and total cell counts were also analyzed. By the point-of-use water dispenser, the turbidity, residual chlorine and pH were decreased and the HPC and total cell counts were increased. The t-test results revealed that the HPC of the tap waters were not significantly different from the treated waters but the total cell counts of the two groups were significantly different. The low pH of the RO filter treatment was also significantly different from the tap waters. This study will contribute to understand the role of the point-of-use water dispenser in improving water quality and to identify key water quality for the proper maintenance of the dispenser systems.

Analysis of Domestic Water Consumption Characteristics for Water Usage Purpose (가정용수의 사용 목적별 소비경향 특성분석)

  • Choi, Sun-hee;Son, Mi-na;Kim, Sang-hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.23-29
    • /
    • 2008
  • Throughout the analysis of field data from water distribution system, valid parameters were determined that can be included in the water service and design plan. This study investigates water consumption patterns to understand the variation of water-demand structures utilizing the pattern analysis of domestic purpose water. Water use data were collected by a public water resources management firm in Korea, Kwater, for 140 houses monitored during three years. Flow meters were installed at the faucet for drinking water, the shower booth, the laundry machine, bathroom sink, toilet, and garden faucet. Data was filtered using multiple physically meaningful criteria to improve analysis credibility. Mann Kendall and Spearman's Rho tests were used to carry out the analysis. Distinct factors of water consumption patterns can be determined for both increasing and decreasing trends of water use. Throughout the data analysis, the characterization of terms was classified and analyzed by the condition of the location of water-demand. Analysis of this data provide a physical basis for the parameter configuration of a reasonable design for a domestic water demand prediction model.

General Factors of the Korean Exposure Factors Handbook

  • Jang, Jae-Yeon;Kim, So-Yeon;Kim, Sun-Ja;Lee, Kyung-Eun;Cheong, Hae-Kwan;Kim, Eun-Hye;Choi, Kyung-Ho;Kim, Young-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.47 no.1
    • /
    • pp.7-17
    • /
    • 2014
  • Risk assessment considers the situations and characteristics of the exposure environment and host. Various physiological variables of the human body reflects the characteristics of the population that can directly influence risk exposure. Therefore, identification of exposure factors based on the Korean population is required for appropriate risk assessment. It is expected that a handbook about general exposure factors will be used by professionals in many fields as well as the risk assessors of the health department. The process of developing the exposure factors handbook for the Korean population will be introduced in this article, with a specific focus on the general exposure factors including life expectancy, body weight, surface area, inhalation rates, amount of water intake, and soil ingestion targeting the Korean population. The researchers used national databases including the Life Table and the 2005 Time Use Survey from the National Statistical Office. The anthropometric study of size in Korea used the resources provided by the Korean Agency for Technology and Standards. In addition, direct measurement and questionnaire surveys of representative samples were performed to calculate the inhalation rate, drinking water intake, and soil ingestion.

Relationships of Food Habits & Life Style and Skin Health of Young Females (젊은 여성의 식습관 및 건강관련 생활습관과 피부건강과의 관련성 연구)

  • Kim, Jong-Gyu;Park, Bong-Seon;Kim, Joong-Soon
    • Korean Journal of Human Ecology
    • /
    • v.20 no.2
    • /
    • pp.449-465
    • /
    • 2011
  • This study was performed to investigate the effects of food habits and life style on the skin health of young Korean females in their late teens and twenties. The study focused on facial skin and used a self-administered questionnaire survey, an examination of skin type, and pH tests. More than half of the females had combination skin type or pH level higher than 5.8 which is regarded as normal. The variables that turned out to significantly (p<0.05) effect their facial skin types were body mass index (BMI), the type of residence, the amount of water intake, whether or not they intake drinks, the frequency and amount of alcohol drinking, favorite foods as side dishes at meals, intake frequency of fruit, the dairy, seaweed, and fast food, the frequency of washing their faces per day, the method of how they used water during face washing, whether or not they had professional skin care, and whether or not they wore color make up. The variables of the females' age, BMI, the amount of alcohol drinking, the frequency and duration of exercise, the controlling methods of stress, their favorite foods as side dishes at meals, and the intake frequency of soy products or animal foods significantly affected their facial pH levels (p<0.05). The results of this study indicate that some food habits and life styles are significantly related with facial skin health. More importantly BMI and favorite foods as side dishes during daily food intake could have remarkable effects on facial skin health.

A Study on the Water Quality of Reservoir Tank in the Building Complex on Jeonnam Area (대형건축물 저수조의 수질실태 및 개선방안에 관한 연구)

  • Lee, J.H.;Lee, H.H.;Kim, H.B.;Ahn, G.W.;Park, K.N.;Kim, Y.K.;Bae, J.S.;Mun, H.;Park, C.U.;Oh, E.H.;Park, S.I.;Seo, Y.G.
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.59-77
    • /
    • 2000
  • This study was carried out to investigate on several factors, which contaminative the water quality through the water pipe during feeding water, in 42 largescaled apart-ments(total 84 cases) and assayed the Volatile Organic Compounds(VOCs) and concen-tration of heavy metals that inflow and outflow in reservior water in Jeonnam area(Mokpo, Suncheon, Yeosu) from January 1999 to December 1999. The results obtained were summarized as follows ; 1. The quality of the water pipe composition in the order of frequency in the quality of water pipes were Copper(45.2%)> Zinc(38.9%)> Stainless steel(9.5%)> PVC(4.8%)> PM(2.4%) in observing 42 sites. All of the drain pipes were used the cast iron quality. 2. The result of certification curve from 12 items(17kind) of VOCs was $1.0-4.0{\mu{g}}/{\ell}$ range, a coefficient of correlation was shown 0.99 over. A MDL of each substance range was within $0.1-1.0{\mu{g}}/{\ell}$. 3. The result of the assay, 5 kinds(Viny chloride, Dichloromethane, Ethylbenzene, M,P-xylene, Styrene) of the VOCs of 14 kinds was not detected and the other items were detected slightly. The detection rate of one item and over in total VOCs samples, were 25.9% in inflow and 27.9% in outflow. And frequency of detect in inflow/outflow of THM(Chloroform, Bromodichloro-methane, Dibromochloromethane, Bromoform) were shown higher than 94.1%, 97.0% each stages. It comes to the conclusion that all of the samples were reason able for drinking water standards. 4. The coefficient of correlation were reasonable, it shown 0.999 over in $0.1-1.0{\mu{g}}/{\ell}$ of a measuring range conditions of 4kinds in organic substance(Zn, Cu, Fe, Mn). 5. The results were showed suitability in 78 cases(92.9%) and unsuitability in 6 cases (7.1%), in 84 cases of in organic substances. Compare to inflow stage, mean concentrations of heavy metal, were increased slightly in Zn, Cu, Fe except Mn than outflow stage. The result of the mean concentration in organic substance inflow and outflow in the apartment water tank using Pair-compared T-test, in 95% reliance index, were $0.179mg/{\ell}(0.151-0.307mg/{\ell})$ in Zinc, $0.136mg/{\ell}(0.113-0.230mg/{\ell})$ in Copper, $0.052mg/{\ell}(0.048-0.098mg/{\ell})$ in Fe, and there was a bit growing tendency but there was no differece in Mn. 6. The mean concentration of Copper which used Cu pipe as a water supply pipe in apartment were $0.216mg/{\ell}(0.161-0.338mg/{\ell})$ in case of the Zine pipe were $0.286mg/{\ell}(0.204-0.435mg/{\ell})$. It shows that the detection rate was more higher than the other material used in Cu or Zn as the water supply pipe. We supposed to Cu and Zn substance were gushing out water supply pipe.

  • PDF

Molecular Typing in Public Health Laboratories: From an Academic Indulgence to an Infection Control Imperative

  • Allerberger, Franz
    • Journal of Preventive Medicine and Public Health
    • /
    • v.45 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • Using three Austrian case studies, the variegated applications of molecular typing in today's public health laboratories are discussed to help illustrate preventive management strategies relying on DNA subtyping. DNA macrorestriction analysis by pulsed field gel electrophoresis has become the gold standard for subtyping of food borne pathogens like listeria, salmonella, campylobacter and Bacillus cereus. Using a Salmonella Mbandaka outbreak from the year 2010 as example, it is shown how the comparison of patterns from human isolates, food isolates, animal isolates and feed isolates can allow to identify and confirm a source of disease. An epidemiological connection between the simultaneous occurrence of tuberculosis in cattle and deer with cases of human tuberculosis due to Mycobacterium caprae in 2010 was excluded using mycobacterial interspersed repetitive units variable-number tandem repeats subtyping. Also in 2010, multilocus sequence typing with nonselective housekeeping genes, the so-called sequence based typing protocol, was used to elucidate connections between an environmental source (a hospital drinking water system) and a case of legionellosis. During the last decades, molecular typing has evolved to become a routine tool in the daily work of public health laboratories. The challenge is now no longer to simply type microorganisms, but to type them in a way that allows for data exchange between public health laboratories all over the world.

A Study on the Water Pollution of Mountain Wells and Mineral Wells around Seoul Area (서울근교(近郊)의 산악수(山岳水) 및 약수(藥水)에 관(關)한 연구(硏究))

  • Park, Yang-Won;Lee, Pyong-Kap;Kim, Hyung-Suk;Park, Soon-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.5 no.1
    • /
    • pp.37-42
    • /
    • 1972
  • Mountain Wells are very important water source for the most of the climbers in Seoul area. But the facilities around the wells are not modernized to prevent from contamination of microorganism and the other pollutants. We focussed our intention on the detection of some harmful chemical ingredients and contaminants. A total of 58 wells were examined according to the Standard Methods(APHA) and the following results were obtained: 1) Among the examined 58 wells, only 10 wells were adequate to the drinking water standard, 2) 7.9mg of liberated $CO_2$ was found in the Tchun-Ho-Dong Mineral Well, 3) Chemically harmful ingredients were not found, 4) The Mountain Wells were contaminated by Coliform groups as many as 18 times than rural wells.

  • PDF