• Title/Summary/Keyword: Pt$P_2S_2$

Search Result 193, Processing Time 0.027 seconds

Cryogenic Behavior of Perovskite Materials

  • Paik, D.S.;Shin, H.Y.;Yoon, S.J.;Kim, H.J.;Park, C.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.126-129
    • /
    • 1999
  • Dielectric and piezoelectric properties of perovskite materials such as La modified $Pb(Zr,Ti)O_3$ ceramics and $Pb(Zn_{1/3}Nb_{2/3})O_3-PbTiO_3$ single crystals were investigated for cryogenic capacitor and actuator applications. Enhanced extrinsic contributions resulted in piezoelectric coefficient (d33) as high as 250 pC/N at 30 K, superior to that of PZT ($d_{33}$ ~ 100 pC/N). This cryogenic property enhancement was associated with retuning the MPB (or cryogenic temperatures. PZN-PT single crystals exhibited dramatic property improvements such as $d_{33}$ > 500 pC/N at 30 K as a result of an engineered domain state.

  • PDF

Comparison of shaping ability between single length technique and crown-down technique using Mtwo rotary file (Mtwo 전동 파일을 사용한 single length technique과 crown-down technique의 근관성형 효율 비교)

  • Lim, Yoo-Kyoung;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.385-396
    • /
    • 2007
  • The aims of this study were to compare the shaping effect and safety between single length technique recommended by manufacturer and crown-down technique using Mtwo rotary file and to present a modified method in use of Mtwo file. Sixty simulated root canal resin blocks were used. The canals were divided into three groups according to instrument and the manner of using methods. Each group had 20 specimens. Group MT was instrumented with single length technique of Mtwo, group MC was instrumented with crown-down technique of Mtwo and group PT was instrumented with crown-down technique of ProTaper. All of the rotary files used in this study were operated by an electric motor. The scanned canal images of before and after preparation were superimposed. These superimposed images were evaluated at apical 1 to 8 mm levels Angle changes were calculated. The preparation time, weight loss, instrument failure and binding, canal aberrations, and centering ratio were measured. Statistical analysis of the three experimental groups was performed with ANOVA and Duncan's multiple range tests for post-hoc comparison and Fisher's exact test was done for the frequency comparison. In total preparation time, group MT and group MC were less than group PT. In the aberrations, group MT had more elbows than those of group MC and group PT. The binding of group MC was least and group MT was less than group PT (P < 0.05). Under the condition of this study, crown-down technique using Mtwo rotary file is better and safer method than single length technique recommended by the manufacturer.

Magnetic Properties and the Order-disorder Phase Transformation of (Fe1-XCoX) Pt Magnetic Thin Films

  • Na, K.H.;Park, C.H.;Na, J.G.;Jang, P.W.;Kim, C.S.;Lee, S.R.
    • Journal of Magnetics
    • /
    • v.4 no.4
    • /
    • pp.119-122
    • /
    • 1999
  • Magnetic properties and crystal structures of (Fe1-XCoX) Pt (X = 0, 0.2, 0.4, 0.5, 0.6, 0.8 and 1.0) ternary thin films were investigated. The order-disorder phase transformation of FePt thin films during annealing was also studied by x-ray diffraction and M ssbauer spectroscopy. The magnetic thin films were deposited on glass substrates using a dc sputtering method and were subsequently annealed at 400~$700^{\circ}C$ in a high vacuum. The as-deposited films exhibited a high degree of the <111> preferred orientation and the preferred orientation was not destroyed even after the subsequent post annealing. The coercivity of the ($Fe_xCo_{1-x}$) Pt thin films annealed at $700^{\circ}C$ showed a minimum value at the equiatomic composition of the Fe and Co atoms. The ordered structure of the FePt alloy was thought to have formed from the disordered structure by an inhomogeneous process, which was confirmed by the asymmetric peak shapes and M ssbauer spectra.

  • PDF

Fabrication and Sensing Properties of Pt-electrode/NASICON Solid Electrolyte/ Carbonate(Na2CO3-K2CO3-CaCO3system ) Electrode for CO2gas sensor (CO2용 Pt전극/NASICON고체전해질/Carbonate (Na2CO3-K2CO3-CaCO3 계) 전극의 가스 센서제작 및 특성)

  • Choi, Jin-Sam;Bae, Jae-Cheol;Bang, Yeong-Il;Lee, Deok-Dong;Huh, Jeung-Su
    • Korean Journal of Materials Research
    • /
    • v.12 no.4
    • /
    • pp.269-273
    • /
    • 2002
  • The NASICON solid electrolyte films, $Na_{1+x}Zr_2Si_xP_{3-x}O_{12}$(1.5< x < 2.3), was prepared from ceramic slurry by modified doctor-blade process. The NASICON solid electrolyte and fabricated sensors, Pt-electrode/NASICON/Carbonate$(Na_2CO_3-K_2CO_3CaCO_3\; system)$ electrode, were investigated to measure phase, microstructure and e.m.f variation for sensing $CO_2$ concentration. The uniform grain size of $2-4{\mu}m$ and major phase of sodium zirconium silicon phosphate phase, $Na_{1+x}Zr_2Si_xP_{3-x}O_{12}$was identified with X-ray diffraction patterns and scanning electron microscopy, respectively. The Nernst's slope of 84 mV/decade for $CO_2$ concentration from 500 to 8000 ppm was obtained at operating temperature of $400^{\circ}C$.

The Development of Electronic Transformer(CT/PT) for Intelligent GIS Based on IEC 60044 (IEC 60044 기반 Intelligent GIS용 전자식 변성기 개발)

  • Kim, M.S.;Jung, J.R.;Kim, J.B.;Song, W.P.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2262-2264
    • /
    • 2005
  • 지금까지 변전소나 개폐소에서 전류, 전압을 계측하는 수단으로서 주로 철심과 권선으로 구성되어진 변류기(CT), 계기용 변압기(PT, PD)가 사용되어져 왔다. 최근, 2차측의 계측기나 보호 Relay의 Digital화가 진전되어 또한 이것을 Digital Network으로 총합한 Intelligent 변전소의 구축이 검토되어지고 있으며, Digital Network에 대응한 변성기 관련규격인 IEC 60044가 근래 제정되어짐에 따라 이에 적합한 전자식 변성기가 요구되어지고 있다. 상기와 같은 요구로 인해 당사에서는 IEC 60044를 기반으로 한 전자식변성기 Layout을 구성하였으며, CT는 검출부에 Rogowski Coil을 적용하며 그 후단에 적분기를 설치하였으며, VD는 검출부에 중간 전극을 이용해서 분압하는 방식인 Capacitive Voltage Divider를 사용하고 증폭기를 삽입하여, 각각 요구되는 전압 신호를 얻었다. 이러한 신형 CT/VD의 적용으로 종래의 CT/PT가 차지하는 공간이 필요없게 되어 컴팩트한 GIS의 구조가 가능하게 되어 있다.

  • PDF

Hematologic Changes and Factors Related to Postoperative Hemorrhage Following Cardiopulmonary Bypass (체외순환에 따른 혈액학적 변화와 술후 출혈에 관계하는 인자에 관한 연구)

  • 김하늘루;황윤호;최석철;최국렬;김승우;조광현
    • Journal of Chest Surgery
    • /
    • v.31 no.10
    • /
    • pp.952-963
    • /
    • 1998
  • Background: Cardiopulmonary bypass(CPB)-induced hemostatic defects may result increased possibility of excessive hemorrhage and additional multiple transfusion reactions or reoperation. Particularly, fibrinolytic activation and decreased platelet count and function by CPB were proposed as a predictor of hemorrhage during postoperative periods in several reports. Materials and methods: Present study, which was conducted in 20 adult patients undergoing CPB, was prospectively designed to examine the hematologic changes, including fibrinolytic activation during and after CPB and to clarify the relationships between these changes and the magnitude of the postoperative nonsurgical blood loss. The serial blood samples for measurment of hematologic parameters were taken during operation and postoperative periods. Blood loss was respectively counted via thoracic catheter drainage at postoperative 3, 6, 12, 24, 48 hours and total period. Results: The results were obtained as follows:Platelet count rapidly declined following CPB(p<0.01), which its decreasing rate was an inverse proportion to total bypass time(TBT, r=0.55, p=0.01), And platelet count in postoperative 7th day was barely near to its control value. Fibrinogen degradating product(FDP) and D-dimer level significantly increased during CPB(p<0.0001, p<0.0001, respectively), and both of fibrinogen and plasminogen concentration correlatively decreased during CPB(r=0.57, p<0.01), implying activation of fibrinolytic system. Postoperative bleeding time (BT), postoperative activated partial thromboplastin time(aPTT) and postoperative prothrombin time (PT) were significantly prolonged as compare with each control value (p=0.05, p<0.0001, p<0.0001, respectively). Total blood loss was positively correlated with patient's age, aortic clamping time (ACT) and TBT, while there was negative correlation between platelet count and blood loss at pre-CPB, CPB-off and the 1st postoperative day, and in some periods. Postoperative aPTT and postoperative PTwere positively related to postoperative 6 hr and 48 hr blood loss(r=0.53, p=0.02; r=0.43, p=0.05) but not to total blood loss, whereas there was no relationship between postoperative BT and blood loss at any period. Conclusions: These observations suggest that CPB results various hematologic changes, including fibrinolytic activation and severe reduction in platelet count. Diverse factors such as age, platelet count, ACT, TBT and postoperative aPTT and PT may magnify the postoperative bleeding. This study will be a basic reference in understanding CPB-induced hemostatic injuries and in decreasing the postoperative hemorrhage

  • PDF

Characterization and bacterial anti-adherent effect on modified PMMA denture acrylic resin containing platinum nanoparticles

  • Nam, Ki-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.207-214
    • /
    • 2014
  • PURPOSE. This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material. MATERIALS AND METHODS. Polymerized PMMA denture acrylic disc ($20mm{\times}2mm$) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transmission electron microscopy), SEM/EDX (scanning electron microscope/energy dispersive X-ray spectroscopy), thermogravimetric and atomic absorption spectrophotometer analysis. In antimicrobial assay, specimens were placed on the cell culture plate, and $100{\mu}L$ of microbial suspensions of S. mutans (Streptococcus mutans) and S. sobrinus (Streptococcus sobrinus) were inoculated then incubated at $37^{\circ}C$ for 24 hours. The bacterial attachment was tested by FACS (fluorescence-activated cell sorting) analysis after staining with fluorescent probe. RESULTS. PtN were successfully loaded and uniformly immobilized into PMMA denture acrylic with a proper thermal stability and similar surface morphology as compared to control. PtNC expressed significant bacterial anti-adherent effect rather than bactericidal effect above 50 mg/L PtN loaded when compared to pristine PMMA (P=.01) with no or extremely small amounts of Pt ion eluted. CONCLUSION. This is the first report on the synthesis and its antibacterial activity of Pt-PMMA nanocomposite. PMMA denture acrylic loading PtN could be a possible intrinsic antimicrobial denture material with proper mechanical characteristics, meeting those specified for denture bases. For clinical application, future studies including biocompatibility, color stability and warranting the long-term effect were still required.

The Study of Hydrometallurgical Process for Recovery of Zinc from Electric Arc Furnace Dust (습식산화법을 이용한 제강분진 내 아연회수에 관한 연구)

  • Moon, Dea-Hyun;Jeung, Jae-Hoon;Chang, Soon-Woong
    • Journal of Environmental Science International
    • /
    • v.25 no.2
    • /
    • pp.331-336
    • /
    • 2016
  • In this study the optimum conditions for recovery of valuable metal in Electric Arc Furnace Dusts were investigated. 2M of $H_2SO_4$, 1~5 of solid/liquid ratio, 0~180 min of leaching time has been established for leaching condition, and for electrowinning, each of Pt, C, Zn, Pb anode and Zn, Cu cathode was compared respectively at pH 2, 4 and 6. The result of elemental analysis of Zn crystal, a lagre quantity of Fe and H has been observed with Zn and other heavy metal, therefore, impurities removing process would be requir for enhancing purity of Zn. As the result, about 60% of Zn has been recovered under condition of 2 M of $H_2SO_4$, 1:2 of S/L ratio at 120 min, and Pt or Pb for anode, Zn for cathode has been shown the highest efficiency of electrowinning at pH 6.

Comparison of Epidermal Growth Factor Receptor Mutations between Primary Tumors and Lymph Nodes in Non-small Cell Lung Cancer: a Review and Meta-analysis of Published Data

  • Wang, Feng;Fang, Ping;Hou, Dan-Yang;Leng, Zai-Jun;Cao, Le-Jie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4493-4497
    • /
    • 2014
  • Background: Epidermal growth factor receptor (EGFR) mutations in non-small cell lung cancer (NSCLC) can predict the clinical response to tyrosine kinase inhibitor (TKI) therapy. However, EGFR mutations may be different in primary tumors (PT) and metastatic lymph nodes (MLN). The aim of this study was to compare EGFR mutations between PT and the corresponding MLN in NSCLC patients, and provide some guidelines for clinical treatment using TKI therapy. Materials and Methods: A systematic review and meta-analysis was performed with several research databases. Relative risk (RR) with the 95% confidence interval (CI) were used to investigate the EGFR mutation status between PT and the corresponding MLN. A random-effects model was used. Results: 9 publications involving 707 patients were included in the analysis. It was found that activation of EGFR mutations identified in PT and the corresponding MLN was 26.4% (187/707) and 19.9% (141/707), respectively. The overall discordance rate in our meta-analysis was 12.2% (86/707). The relative risk (RR) for EGFR mutation in PT relative to MLN was 1.33 (95%CI: 1.10-1.60; random-effects model). There was no significant heterogeneity between the studies ($I^2$=5%, p=0.003). Conclusions: There exists a considerable degree of EGFR mutation discrepancy in NSCLC between PT and corresponding MLN, suggesting that tumor heterogeneity might arise at the molecular level during the process of metastasis.

Development and Application of a Self-management Program based on Prothrombin INR Monitoring for Patients with Cardiac Valve Replacement (심장판막수술 후 프로트롬빈 INR 모니터링형 자가관리프로그램 개발 및 적용)

  • Jeon, Hyun Rye;Park, Jeong Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.4
    • /
    • pp.554-564
    • /
    • 2015
  • Purpose: The purpose of this study was to develop and evaluate a self-management program based on INR monitoring for patients with cardiac valve replacement. Methods: This program was comprised of five weekly sessions based on Sousa's Enhance-Behavior Performance Model. The first session included individual teaching, and the other four sessions included Prothrombin Time International Normalized Ratios (PT INR) self-monitoring, telephone counseling and self-management checklist recording. Participants were patients who had cardiac valve replacement. They were randomly assigned to the experimental or control group. Sixteen in the experimental group participated in the self-management program and seventeen in the control group participated in general care. Self-management knowledge, self-efficacy, self-management behavior and PT INR were measured as dependent variables. Data were analyzed using Mann Whitney U-test, t-test and ANCOVA. Results: The experimental group showed significantly higher post-test scores in self-management knowledge (t=5.86, p<.001), self-efficacy (F=18.32, p<.001), and self-management behavior (t=3.44, p=.002) compared to the control group. Also, the experimental group showed significantly higher frequency in maintaining the treatment range of PT INR compared to the control group (${\chi}^2=4.80$, p=.028). Conclusion: The results of the research on the self-management program based on PT INR monitoring showed that it is effective in improving self-management knowledge, self-efficacy, and self-management behavior as well as maintaining treatment range of PT INR of patients with cardiac valve replacement.