• 제목/요약/키워드: Protein array

검색결과 195건 처리시간 0.031초

Protein Array Fabricated by Microcontact Printing for Miniaturized Immunoassay

  • Lee Woo-Chang;Lim Sang-Soo;Choi Bum-Kyoo;Choi Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권8호
    • /
    • pp.1216-1221
    • /
    • 2006
  • A protein array was fabricated for a miniaturized immunoassay using microcontact printing ($\mu$CP). A polydimethylsiloxane (PDMS) stamp with a 5 $\mu$m$\times$5 /$\mu$m dimension was molded from a silicon master developed by photolithography. Under optimal fabrication conditions, including the baking, incubation, and exposure time, a silicon master was successfully fabricated with a definite aspect ratio. An antibody fragment was utilized as the ink for the $\mu$CP, and transferred to an Au substrate because of the Au-thiol (-SH) interaction. The immobilization and antibody-antigen interaction were investigated with fluorescence microscopy. When human serum albumin (HSA) was applied to the protein array fabricated with an antibody against HSA, the detection limit was 100 pg/ml of HSA when using a secondary antibody labeled with a fluorescence tag. The fabricated protein array maintained its activity for 14 days.

Recent Development of Protein Microarray and Proteogen Platform

  • Han, Moon-Hi;Kang, In-Cheol;Lee, Yoon-Suk;Cho, Yong-Wan;Lee, Eun-Kyoung
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVI)
    • /
    • pp.47-47
    • /
    • 2005
  • There are many different surface technologies currently applied for preparation of protein chips. However, it requires innovative surface chemistry for capture proteins to be immobilized on chip surface keeping their conformation and activity intact and their orientation right, while they bind tightly and densely in a given array spot. Proteogen has developed 'ProteoChip BP' coated with novel proprietary linker molecules $(ProLinker^{TM})$ for efficient and robust immobilizations of capture proteins by improving surface properties of molecular captures. It was demonstrated that $ProLinker^{TM}$ gave the best surface performance in preparation of protein microarray chip base plates among others currently available on the market. In particular, the $ProLinker^{TM}-based$ surface chemistry has demonstrated to provide excellent performance in preparation of 'Antibody Chip' for analysis of biomarkers as well as proteome expression profiles. The linker molecule has also shown to be well applicable for development of biosensors and micro-beads as well as protein microarray and nano-array. ProteoChip BP can be used either for preparation of high-density array by using a microarrayer or for preparation of 'Well-on-a-Chip' with low density array, which is better applicable for quantitative analysis of biomarkers or protein-protein interactions. The biomarker assay can be performed either by direct or sandwich methods of fluorescence immunoassay. Application of ProteoChip BP has been well demonstrated by the extensive studies of 1) tumor-marker assays, 2) new drug screening by using 'Integrin Chip' and 3) protein expression profile analysis. Some of experimental results will be presented.

  • PDF

퍼지적분을 이용한 단백질패턴에 관한 특징추출 (Feature Extraction for Protein Pattern Using Fuzzy Integral)

  • 송영준;권혁봉;김미혜
    • 한국콘텐츠학회논문지
    • /
    • 제7권1호
    • /
    • pp.40-47
    • /
    • 2007
  • 단백질 매크로 어레이 영상에서 단백질 칩 각각의 특징을 규명하는 것은 중요한 것이다. 사람의 시각에 의한 판단은 많은 단백질 칩 영상을 실험할 경우, 장시간의 관찰과 그로 인한 오류가 발생할 수 있다. 따라서 시뮬레이터를 통한 특성 파악이 필요하게 되고, 매크로 어레이 스캔 영상에 대해 특성 분석을 할 경우 효율을 극대화할 수 있다. 형광 스캔 영상에 있어서, 각 셀의 반응도는 컬러 영상의 R, G, B 분포에 의존하여 왔다. 그러나 중첩되는 영상의 경우는 한쪽으로 구분하여 분류하기가 어렵다. 본 논문은 이러한 단점을 극복하기 위해 사용자가 원하는 색상에 대한 퍼지 측도 값을 적용한 퍼지 적분 값으로서 단백질 칩의 반응색상을 구분 지었다. Scan Array 5000에 의해 구성된 매크로 어레이 형광 영상들에 대해 실험한 결과, 퍼지 적분을 사용한 제안 방법이 모호한 색상에 대해 결정을 내릴 수 있는 요소가 됨을 보여 주었다.

DNA and Protein Array

  • 이충식
    • 대한생식의학회:학술대회논문집
    • /
    • 대한불임학회 2001년도 제2차 연수강좌
    • /
    • pp.229-235
    • /
    • 2001
  • PDF

Lab-on-a-Chip for Monitoring the Quality of Raw Milk

  • Choi Jeong-Woo;Kim Young-Kee;Kim Hee-Joo;Lee Woo-Chang;Seong Gi-Hun
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권8호
    • /
    • pp.1229-1235
    • /
    • 2006
  • A lab-on-a-chip (LoC) was designed for simultaneous monitoring of microorganisms, antibiotic residues, somatic cells, and pH in raw milk. The LoC was fabricated from polydimethylsiloxane (PDMS) using microelectromechanical system (MEMS) technology, which consisted of two parts; a protein array and microchannel. The protein array was fabricated by immobilizing five types of antibodies corresponding to two microorganisms, two antibiotic residues, and somatic cells. A sol-gel film was deposited on a glass substrate to immobilize the antibodies. The target analytes in raw milk could be bound with the corresponding antibody by an immunoreaction, and the antigen-antibody complex was detected using fluorescence microscopy. SNARF-dextran was used as a pH indicator, and the SNARF-entrapped hydrogel was attached to the microchannel in the chip. After injecting the milk sample into the channel, the pH was measured by monitoring the change in fluorescence intensity by fluorescence microscopy. The on-chip simultaneous assay of two microorganisms (E. coli O157:H7 and Streptococcus agalactiae), two antibiotic residues (penicillin G and dihydrostreptomycin), and neutrophils was successfully accomplished using the proposed LoC system.

카드뮴이 흰쥐 뇌기저핵의 유전자 발현에 미치는 영향 (Effects of Cadmium on the Gene Expression Profile in the Rat Basal Ganglia)

  • 이채관
    • 한국산업보건학회지
    • /
    • 제20권1호
    • /
    • pp.29-40
    • /
    • 2010
  • This study was aimed at investigating the gene expression profile in basal ganglia of cadmium exposed rat based on cDNA array analysis. For cDNA array analysis, adult Sprague-Dawley male rats (350 ${\pm}$ 25 g) were intraperitoneally injected with 2.0 mg/kg body weight/day of CdCl2 (0.3 ml) for 5 days. For doserelated gene expression analysis rats were intraperitoneally injected with 0.0, 0.1, 0.3, 1.0 mg/kg body weight/day of CdCl$_2$ for 5 days. Control rats were injected with equal volume of saline. Cadmium concentration of brain was analyzed by atomic absorption spectrophotometer. For cDNA array, RNA samples were extracted from basal ganglia and reverse-transcribed in the presence of [${\alpha}$32P]-dATP. Membrane sets of the Atlas Rat 1.2 array II and Toxicology array 1.2 (Clontech, Palo Alto, CA) were hybridized with cDNA probe sets. RT-PCR was employed to validate the relative gene expression patterns obtained from the cDNA array. Northern blot hybridization methods were employed to assess the dose-related gene expression. Among the 2352 cDNAs, 671 genes were detected in both array sets and 63 genes of 38 classes showed significant (more than two fold) changes in expression. Thirty five of these genes were up-regulated and twenty eight were down-regulated in the cadmium exposed group. According to the dose-related gene expression analysis, heat shock 27 kDa protein (HSP27), neurodegeneration-associated protein 1 (Neurodap 1) genes were significantly up-regulated and melatonin receptor 1a (Mel1a), Kinesin family member 3C (KIF3C), novel kinesinrelated protein (KIF1D) genes were significantly downregulated even in the low-dose of cadmium exposed group (0.1 mg/kg body weight/day). Conclusions Sixty three genes detected in this study can give some more useful informations about the cadmium-induced neurotoxicity in the basal ganglia. As well as, HSP27, Neurodap1, Mel1a, KIF3C and KIF1D genes may be useful for the study of the cadmium-induced neurotoxicity because these genes showed dramatic changes of mRNA levels in response to the low dose of cadmium exposure.

Comparative Studies of Protein Modification Mediated by Fenton-like Reactions of Iron, Hematin, and Hemoglobin: Generation of Different Reactive Oxidizing Species

  • Kim, Young-Myeong;Kim, Sung-Soo;Kang, Gu;Yoo, Yeong-Min;Kim, Ki-Mo;Lee, Mi-Eun;Han, Jeong-A;Hong, Sun-Joo
    • BMB Reports
    • /
    • 제31권2호
    • /
    • pp.161-169
    • /
    • 1998
  • TThe reactive oxygen species oxidatively modify the biological macromolecules, including proteins, lipids, and nucleic acids. Iron- and heme-mediated Fenton-like reactions produce different pro-oxidants. However, these reactive products have not been clearly characterized. We examined the nature of the oxidizing species from the different iron sources by measuring oxidative protein modification and spectroscopic study. Hemoglobin (Hb) and methemoglobin (metHb) were oxidatively modified in $O{\array-\\\dot{2}}$ and $H_{2}O_{2}$ generating systems. Globin and bovine serum albumin (BSA) were also modified by iron, iron-EDTA, hematin, and Hb in an $O{\array-\\\dot{2}}$ generating system. In a $H_{2}O_{2}$ generating system, the iron- and iron-EDTA-mediated protein modifications were markedly reduced while the Hb-and hematin-mediated modifications were slightly increased. In the $O{\array-\\\dot{2}}$ generating system, the iron- and iron-EDTA-mediated protein modifications were strongly inhibited by superoxide dismutase (SOD) or catalase, but heme- and Hb-mediated protein modifications were inhibited only by catalase and slightly increased by SOD. Mannitol, 5,5-dimethyl-l-pyrroline-N-oxide (DMPO), deoxyribose, and thiourea inhibited the iron-EDTA-mediated protein modification. Mannitol and DMPO, however, did not exhibit significant inhibition in the hematin-mediated modification. Desferrioxamine (DFO) inhibited protein modification mediated by iron, but cyanide and azide did not, while the hematin-mediated protein modification was inhibited by cyanide and azide, but not significantly by DFO. The protein-modified products by iron and heme were different. ESR and UV-visible spectroscopy detected the DMPO spin adduct of the hydroxyl radical and ferryl ion generated from iron-EDTA and metHb, respectively. These results led us to conclude that the main oxidizing species are hydroxyl radical in the iron-EDTA type and the ferry I ion in the hematin type, the latter being more effective for protein modification.

  • PDF

자성체 어레이를 이용한 단백질칩 (Protein Chip by Magnetic Array)

  • 최용성;이경섭;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.426-427
    • /
    • 2005
  • This research describes a new constructing method of multifunctional biosensor using many kinds of biomaterials. A metal particle and an array was fabricated by photolithographic. Biomaterials were immobilized on the metal particle. The array and the particles were mixed in a buffer solution, and were arranged by magnetic force interaction and self-assembly. A quarter of total Ni dots were covered by the particles. The binding direction of the particles was controllable, and condition of particles was almost with Au surface on top. The particles were successfully arranged on the array. The biomaterial activities were detected by chemiluminescence and electrochemical methods.

  • PDF