• Title/Summary/Keyword: Protective relay

Search Result 237, Processing Time 0.065 seconds

Analysis on the Operational Characteristic between the Protective devices and Superconducting Fault Current Limiter with a Peak Current Limiting Function in the Power Distribution System (피크전류 제한 기능을 갖는 초전도한류기의 계통 적용에 따른 보호기기간 동작특성 분석)

  • Cho, Yong-Sun;Kim, Jin-Seok;Kim, Jae-Chul;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.11
    • /
    • pp.75-80
    • /
    • 2012
  • In this paper, the operational characteristics due to the introduction of the superconducting fault current limiter(SFCL) with a peak current limiting function were analyzed in the power distribution system. The parallel structure of the superconducting element can operate the peak current limiting function depending on the transient amplitude of fault current. We studied the operating characteristics of the introduction of the SFCL with a peak current limiting function in the power distribution system. Furthermore, we were analyzed between the SFCL with a peak current limiting function and the protection devices in the power distribution system, through the short circuit experiments.

Distance Relaying Algorithm Using a DFT-based Modified Phasor Estimation Method (DFT 기반의 개선된 페이저 연산 기법을 적용한 거리계전 알고리즘)

  • Lee, Dong-Gyu;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1360-1365
    • /
    • 2010
  • In this paper, we propose a distance relaying algorithm using a Discrete Fourier Transform (DFT)-based modified phasor estimation method to eliminate the adverse influence of exponentially decaying DC offsets. Most distance relays are based on estimating phasors of the voltage and current signals. A DFT is generally used to calculate the phasor of the fundamental frequency component in digital protective relays. However, the output of the DFT contains an error due to exponentially decaying DC offsets. For this reason, distance relays have a tendency to over-reach or under-reach in the presence of DC offset components in a fault current. Therefore, the decaying DC components should be taken into consideration when calculating the phasor of the fundamental frequency component of a relaying signal. The error due to DC offsets in a DFT is calculated and eliminated using the outputs of an even-sample-set DFT and an odd-sample-set DFT, so that the phasor of the fundamental component can be accurately estimated. The performance of the proposed algorithm is evaluated for a-phase to ground faults on a 345 kV, 50 km, simple overhead transmission line. The Electromagnetic Transient Program (EMTP) is used to generate fault signals. The evaluation results indicate that adopting the proposed algorithm in distance relays can effectively suppress the adverse influence of DC offsets.

Performance Analysis of the GOOSE Transmission of an IED Considering Network Redundancy (네트워크 이중화를 고려한 IED GOOSE 전송에 관한 성능 분석)

  • Lee, Nam-Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.75-80
    • /
    • 2009
  • In order to prevent loss of communication packets and drop of transmission speed owing to the network fault occurrence, it should be considered network redundancy. That is why a messages of IED GOOSE is the critical signal in charge of protection and control of the substation. So most of users implement the substation automation system with Hybrid network topology ant IED supporting double ethernet ports. Because IEC 61850 GOOSE conformance test is limited in the functional test, this paper suggests how to test the performance of IED GOOSE transmission considering Network redundancy, and describes the analysis of an example test on real IEDs and how to impact the IED GOOSE performance to the substation automation system.

Development of ACL Modul For Agent Communication in Auto-Adaptive OCR Agent (자율적응형 과전류계전기 에이전트의 통신을 위한 ACL모듈 개발)

  • Oh, T.W.;Lee, S.J.;Choi, M.S.;Kim, K.H.;Lim, S.I.;Min, B.W.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.193-195
    • /
    • 2002
  • In this paper, a communication module is proposed to be applied to communication between over current relay (OCR) agents in multi agent protection system. A multi agent system can achieve a global goal beyond the ability of each individual agent by working together, in which it is the prerequisite for each agent to be able to exchange or share information or processing status with other agent. The proposed communication module is purposed to enable not only each agent to bring about its own goal, but also the whole protective system to provide much improved coordinated protection. It is applied to a self adaptive protection system for a distribution network using multi agent concept to show its effectiveness.

  • PDF

Arc-Flash Detection Sensor Based on Surface Coupling of Plastic Optical Fiber (플라스틱 광섬유 표면 입사 현상을 이용한 아크플래시 검출 광센서)

  • Jeong, Hoonil;Kim, Myoung Jin;Kim, Young Ho;Kim, Youngwoong;Rho, Byung Sup
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.208-212
    • /
    • 2016
  • In this work, a loop sensor for Arc-Flash detections has been developed in order to trip a circuit breaker within 2.5 ms after an Arc-Flash event. For an efficient capturing of the flash light, plastic optical fibers, where light attenuations are larger than those in silica-based ones, with different diameters and surface conditions were utilized. The performance was comparatively analyzed with those of a point sensor and a commercialized product. The point sensor module was designed for hemisphere-like capturings of Arc-Flashes larger than 3 kA at 2 meters from the sensor. On the other hand, the loop sensor allowed 360-degree-detections around the fiber axis and the measurement range was dependent on the length of the fiber connected to the sensor module. The trip-level-dependent brightness measurement results showed that the fabricated point sensor and loop sensor satisfied a brightness condition, 10~40 klux, and the responses of the system to Arc-Flashes were completed within 2.5 ms.

Analysis of an Active Superconducting Current Controller (ASCC) Considering the Transient Stability and OCR Operation in Transmission and Distribution Systems

  • Gusheh, Ahmad Ghafari;Soreshjani, Mohsen Hosseinzadeh;Rahat, Omid
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.543-550
    • /
    • 2016
  • The Active Superconducting Current Controller (ASCC) is a new type of Superconducting Fault Current Limiters (SFCL) which can limit the fault current in different modes. It also has the particular abilities of compensating active and reactive powers for electrical networks. In this paper, it is confirmed that the performance of ASCC in different operating modes introduces a limiting impedance in series with the network which can even degrade the transient stability and the operation of the Over-Current Relays (OCR) employed in a power system. In addition, the model of a three-phase ASCC is simulated, and the effect of descriptive modes on the current limiting level is investigated. For the transient stability analysis, a single machine-infinite bus system is tested, and the effect of operation modes is studied based on an equal area criterion obtaining the critical time and the critical angle. Modifying the setting parameters of OCR such as time dial and pick-up current, the protective coordination is also studied in different operating modes.

Analysis of Inrush Current Reduction Rate According to Insertion Resistance of the Superconducting Fault Current Limiter (초전도 한류기 투입저항 변화에 따른 여자돌입전류 저감률 분석)

  • Park, Se-Ho;Seo, Hun-Chul;Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.257-258
    • /
    • 2008
  • The inrush current of a transformer is a high-magnitude and harmonic-rich current generated when the transformer core is driven into saturation during energizing. The inrush current usually leads to undesirable effects, for example potential damage to the transformer, misoperation of a protective relay, and power quality deterioration in the distribution power system. Inrush current reduction is therefore important for power system operation. In this paper, to reduce the inrush current, the insertion resistance of the Superconducting Fault Current Limiter (SFCL) that is connected in series with the transformer in the distribution system is used. This paper implements the SFCL by using the Electromagnetic Transient Program-Restructured Version (EMTP-RV) to model the SFCL in the distribution system. The simulation results show the beneficial effects of the SFCL for reduction of the inrush current.

  • PDF

Operational characteristics analysis of protective relay for utility application of HTS power cable (초전도 전력케이블의 계통 적용을 위한 보호계전기의 동작특성 분석)

  • Kim, Jae-Ho;Kim, Jin-Geun;Sim, Ki-Deok;Cho, Jeon-Wook;Yoon, Jae-Young;Lee, Seung-Ryul;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.57-58
    • /
    • 2008
  • Recently, several kinds of superconductivity applications are implemented and evaluated in the utility power networks. The protection system for HTS(High Temperature Superconducting) power devices safe operation has not been established yet. For the protection of the HTS apparatus, a better understanding of the quench properties against fault current and appropriate protection devices are required. In this study, an algorithm of protection system is developed with respect to HTS power cable. The protection system of HTS power cable was analyzed in the simulated power system. Results obtained from simulation will provide much more decisive data in order to design a certain superconducting power device, and can give a good information for the installation in power system.

  • PDF

Research on the Protective Relay considers the Power System interconnected to small scale Distributed Generation. (소규모 분산전원의 계통연계를 고려한 보호계전에 관한 연구)

  • Ko, Yeon-Seong;Lee, Jong-Su;Lee, Bock-Ku;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.506-507
    • /
    • 2008
  • 소규모 풍력에너지, 연료전지 및 태양에너지 등의 신 재생에너지원들이 소규모 분산전원으로 도입되고 있다. 이로 인해, 수용가 측의 전원이 대규모 전력사업자로부터만 공급받던 시스템방식에서, 분산전원과 연계하여 동시에 사용하는 방식으로 바뀌고 있다. 이러한 분산전원이 계통에 도입될 경우 이로 인해 평상시 기존 계통의 보호방식에 미치는 영향의 경우는 상시전압변동, Flicker, 병해열로 인한 순시전압변동, 고조파, 불평형 등이 고려 될 수 있다. 또한 이러한 경우로 인해 보호계전기의 오동작도 초래 할 수 있다. 이에 본 논문에서는 태양광시스템을 분산전원으로 하는 연계 계통을 모델링하여 발생하는 파형에 대해 분석한다. 또한 디지털 보호계전기의 디지털 필터링 기법을 비교하여 빠른 연산 속도와 주파수 응답 특성을 가지는 알고리즘을 선정하고 모델링하여 모델링 된 디지털 필터로 분산전원 연계를 통해 얻어진 파형을 필터링 한다. 본 논문에서 분산전원의 계통 모의는 전력계통에 모의에 높은 신뢰성을 가지는 PSCAD/EMTDC를 기반으로 하였으며, 디지털 보호계전기의 디지털 필터 알고리즘 모델링은 MATLAB을 사용하였다.

  • PDF

Commercial Grade Item Dedication of Digital Devices for Safety-related System in Nuclear Power Plant (원자력발전소 안전등급 계통 적용을 위한 디지털 상용기기 품질검증)

  • Hong, Young Hee;Bae, Byung Hwan;Park, Jaehyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1637-1639
    • /
    • 2014
  • In the past, the analog protection relays have been widely used for the safety-related systems in the nuclear power plants due to their stability and reliability. Meanwhile, as the high performance digital system has been developed, the digital systems have been adopted in the non-safety systems. However, since the digital systems currently used in the non-safety systems were not developed according to Q-class standard, Commercial Grade Item Dedication (CGID) procedure should be performed in order to apply them to the safety-related system. The purpose of this paper is to describe the CGID procedure including the analysis of the hardware architecture as well as the software embedded in protective relay to apply to the emergency diesel generator in the nuclear power plant. The entire CGID procedure was performed strictly according to the international standard and regulations.