• 제목/요약/키워드: Protective System

검색결과 1,336건 처리시간 0.027초

저압차단기의 차단보호협조 특성연구 (A study of coordination under short-circuit conditions between circuit-breakers)

  • 오준식;나칠봉;함길호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.476-478
    • /
    • 2001
  • Coordination under short-circuit conditions is a systematic application of protective devices in the electrical power system, which, in response to a fault, will remove only a minimum amount of equipment from service. The objective is not only to minimize the equipment damage and process outage costs, but also to protect personnel from the effects of these failures. The coordination study of an electric power system consists of an organizes time-current study of all devices in series from the utilization device to the source. This study is a comparison of the time it takes the individual devices to operate when certain levels of normal or abnormal current pass through the protective devices. The objective of a coordination study is to determine the characteristics, ratings, and settings of overcurrent protective devices that will ensure that the minimum unfaulted load is interrupted when the protective devices isolate a fault or overload anywhere in the system. At the same time, the devices and settings selected should provide satisfactory protection against overloads on the equipment and interrupt short-circuit as rapidly as possible.

  • PDF

강우에 의한 풍력 발전기 블레이드 전연부 침식 시험에 관한 연구 (A Study on the Erosion of Wind Turbine Blade Leading Edge by Rain)

  • 김태원;문기웅;손진혁;김보중;유시홍;윤창번
    • 풍력에너지저널
    • /
    • 제14권3호
    • /
    • pp.43-53
    • /
    • 2023
  • To improve AEP, wind turbine blade lengths are increasing every year. As the length of blades increases, the blade tip speed also increases. Because of the increased tip speed, the impact energy between the leading edge and raindrops also increases. The increased impact energy is the primary factor contributing to erosion of the blade's leading edge. Blade leading edge erosion reduces aerodynamic performance, increases repair costs, and causes downtime. Therefore, numerous studies are being conducted on protective solutions and RET systems to prevent and delay erosion of the blade's leading edge. However, few institutions in Korea research protective solutions and RET systems. In this study, we aim to develop a laboratory-scale RET system. The developed RET system was based on the ASTM G73-10 standard. As a result of the RET, it was confirmed that the erosion tendency was similar to that of overseas institutions. In addition, the effectiveness of the RET system was verified by a maximum erosion rate of 0.0023 for an epoxy-based protective solution.

중용량 전동기보호를 위한 전류형 디지털 보호계전기 개발 (Development of Current-based Compact Digital Protective Relay for Induction Motor Protection)

  • 정종진;김중표;신종한;박장수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.140-142
    • /
    • 2005
  • This paper describes the current- based compact digital motor protective relay for low and high voltage induction motors, which are widely used in industrial and commercial power systems. The existing protective relays for motor protection had only overload, short circuit, reverse phase, open circuit and grounding protective elements, and measurement, start/stop control function. But in present day, for automation system, various functions are required, especially motor management and sequence control function and more. To meet these requirements, we developed an economic current-based compact digital motor protective relay which had various function to control, manage and monitor the induction motor.

  • PDF

Improvement of Protective Properties of Top Coatings Applied on Zinc-Rich Primer by 3-Aminopropyl-Triethoxysilan and 2-(Benzothialylthio) Succinic acid

  • Trinh, Anh Truc;To, Thi Xuan Hang;Vu, Ke Oanh;Nguyen, Tuan Dung
    • Corrosion Science and Technology
    • /
    • 제3권3호
    • /
    • pp.107-111
    • /
    • 2004
  • Corrosion resistance of coating system consisting of zinc-rich primer (ZRP) and topcoat based on polyurethane resin with the presence of 3-aminopropyl-triethoxysilan (APS) and 2-(benzothialylthio) succinic acid (BSA) was studied by electrochemical impedance and wet adhesion. The interface metal/primer/topcoat was analyzed by scanning electronic microscopy. It was found that the presence of APS and BSA improved adhesion and barrier property of the topcoats.

파형 비교를 이용한 데이터 압축 기법 (Data Compression using Waveform Comparison)

  • 성성만;임성일;이승재;배영준;진용우;김정한;김병진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.151-153
    • /
    • 2003
  • This paper was studied on using data of the protective relay by Power Quality Monitor. The protective relay will have problem to save data for PQM(Power Qualify Monitoring) analysis because the protective relay memory is limited. So this paper was proposed new data compression of the data was get from the protective relay. The scheme is compared each cycle after DFT(Discrete Fourier Transform). And scheme is verified through simulation of protective relay data was from real distribution system.

  • PDF

IEC 60364 적용 및 TN-S 시스템에서 보호 도체 산정 및 적정성에 관한 연구 (Assessment Method and Calculations for Protective Conductor of TN-S System and IEC 60364 Application)

  • 김기현;이주철;최영규;김한수;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.86-91
    • /
    • 2012
  • A conductor has been produced according to IEC standard and low voltage electrical facility has been installed according to IEC 60364. So we must comply with international standard for design, construction and inspection. But because of many related and varied standards, it is difficult to apply to design and inspect for electrical equipment. We researched the necessity of design guide which is detailed and systematization from survey. For detailed design guide, we suggest calculation method of protective conductor cross-sectional area at TN-S system according to BS 7671 regulation and KS C IEC 60364 standard.

Evaluation of Corrosion Protection for Epoxy and Urethane Coating by EIS under Various Cyclic Corrosion Tests

  • Hyun, Jonghun;Shon, Minyoung
    • Corrosion Science and Technology
    • /
    • 제10권3호
    • /
    • pp.95-100
    • /
    • 2011
  • Protective coatings play an important role in the protection of metallic structures against corrosive environment. The main function of anticorrosive coating is to prevent the materials from corrosive agents, such as water, oxygen and ions. In the study, the corrosion protection properties of urethane and epoxy coating systems were evaluated using EIS methods exposed to the corrosion acceleration test such as Norsok M501, Prohesion and hygrothermal cyclic test. AFM analysis of the coating systems was carried out to monitor the change of roughness of coatings. Urethane coating system was more stable than the epoxy coating under given cyclic conditions. Water uptake into the urethane coatings was less than that into the epoxy coating. The urethane coating system showed better corrosion protection than epoxy coating system based on the changes of the impedance modulus at low frequency region with exposure time. Consequently, the corrosion protection properties of the epoxy and urethane coatings was well correspond with their surface roughness changes and water uptakes.

배전보호협조를 고려한 초전도 한류임피던스 제한에 필요성 연구 (Study on the Necessity for Limiting Impedance of Superconducting Fault Current Limiter Considering Protective Coordination of power distribution)

  • 안재민;김진석;문종필;임성훈;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.34-36
    • /
    • 2008
  • In this paper, we study on the necessity for limiting impedance of Superconducting Fault Current Limiter(SFCL) considering protective coordination. Several countermeasures have been proposed to protect the power system effectively from the larger fault current. Among them, the SFCL has been expected as one of the most effective solutions. However, the application of SFCL into power system can cause some problems, such as non-operation of instantaneous elements, of protective coordination because of limiting fault current. So we suggest that impedance of SFCL is must limited for operation of instantaneous elements. 'This method is essential to introduce application of SFCL into power distribution system.

  • PDF

Adaptive Protection Algorithm for Overcurrent Relay in Distribution System with DG

  • Sung, Byung Chul;Lee, Soo Hyoung;Park, Jung-Wook;Meliopoulos, A.P.S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1002-1011
    • /
    • 2013
  • This paper proposes the new adaptive protection algorithm for inverse-time overcurrent relays (OCRs) to ensure their proper operating time and protective coordination. The application of the proposed algorithm requires digital protection relays with microcontroller and memory. The operating parameters of digital OCRs are adjusted based on the available data whenever system conditions (system with distributed generation (DG)) vary. Moreover, it can reduce the calculation time required to determine the operating parameters for achieving its purpose. To verify its effectiveness, several case studies are performed in time-domain simulation. The results show that the proposed adaptive protection algorithm can keep the proper operating time and provide the protective coordination time interval with fast response.

배전자동화 적용선로 보호기기 자동정정 프로그램 개발 (The Development Plan of the Protection Device Auto-coordination Program in the Distribution Automation System)

  • 강문호;하복남;임성일;조남훈;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.129-131
    • /
    • 2001
  • In order to improve the reliability of power service and the effective management of distribution power system. DAS (Distribution Automation system) is widely used in KEPCO(Korea Electric Power Corporation) branch offices. Based on the present protective device coordination program which used in KEPCO. this study presents the new concept about both protective device coordination program maximizing the characteristics of DAS and development plan of protective device auto-coordination program with the merits of DAS.

  • PDF