• Title/Summary/Keyword: Protective System

Search Result 1,329, Processing Time 0.026 seconds

An Expert System for Protection Coordiantion in 22.9KV Distribution System Design (22.9KV 배전설게 보호협조을 위한 전문가 시스템)

  • 김호용;고윤석;손수국;남기영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.2
    • /
    • pp.119-132
    • /
    • 1990
  • To design protection coordination for an electric power distribution system, an expert system is developed, using both the veteran expert's heuristics and the guide book for the distribution facility operation considering feeder configuration, service route, load characteristics fault current and load current. The expert system developed in this papaer determines the type of protective device(clearing current and sequence). The location and rating change of protective device in the old feeder is realized by using old database. Current(T-C) curves of various kinds of protective devices are stored in Knowledge Base (KB). The expert system is developed on a 32 bit personal computer using PROLOG, AutoCAD,dBASEIIIPLUS and FORTRAN. To compute the fault current and loadflow, FORTRAN is used.

  • PDF

Development of Web-based Protection Relay Setting Program in Power System (전력시스템 보호를 위한 웹기반 계전기 정정 프로그램 개발)

  • Bok, Jeong-Song;Jeong, Ho-Sung;Shin, Myong-Chul;Cho, In-Suk;Seo, Hee-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.246-248
    • /
    • 2001
  • For protection of power system, it is a prerequisite to action characteristics of protective relay about a changing environment in power system and correcting the setting value. A substation operator always reside to correct of a relay, however there are problem of efficiency. Recently, power system operation become manless and supervision and control of incident is required anywhere, introduction of new concept as a intellectual manless protective relay is a recent trend. This paper is the web-based protective relay setting program that a manager make an analysis of operation and incident of power system through the web at a remote place corresponding recent manless of system and approach the protection relay and then can correct the error.

  • PDF

Application of Multi-Agent System to Over Current Protective Relaying System (과전류 보호계전 시스템에의 Multi-Agent System 응용)

  • Chang, Choong-Koo;Min, Byung-Un;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.209-211
    • /
    • 2000
  • This paper presents a Multi-Agent system for setting and coordination of overcurrent protective devices in the distribution system. The simulation model shows its feasibility in which KQML is used for communication among agents. The proposed system could make it possible to keep the protection system in the optimal state all the time.

  • PDF

Comparison of classical and reliable controller performances for seismic response mitigation

  • Kavyashree, B.G.;Patil, Shantharama;Rao, Vidya S.
    • Earthquakes and Structures
    • /
    • v.20 no.3
    • /
    • pp.353-364
    • /
    • 2021
  • Natural hazards like earthquakes, high winds, and tsunami are a threat all the time for multi-story structures. The environmental forces cannot be clogged but the structures can be prevented from these natural hazards by using protective systems. The structural control can be achieved by using protective systems like the passive, active, semi-active, and hybrid protective systems; but the semi-active protective system has gained importance because of its adaptability to the active systems and reliability of the passive systems. Therefore, a semi-active protective system for the earthquake forces has been adopted in this work. Magneto-Rheological (MR) damper is used in the structure as a semi-active protective system; which is connected to the current driver and proposed controller. The Proportional Integral Derivative (PID) controller and reliable PID controller are two proposed controllers, which will actuate the MR damper and the desired force is generated to mitigate the vibration of the structural response subjected to the earthquake. PID controller and reliable PID controller are designed and tuned using Ziegler-Nichols tuning technique along with the MR damper simulated in Simulink toolbox and MATLAB to obtain the reduced vibration in a three-story benchmark structure. The earthquake is considered to be uncertain; where the proposed control algorithm works well during the presence of earthquake; this paper considers robustness to provide satisfactory resilience against this uncertainty. In this work, two different earthquakes are considered like El-Centro and Northridge earthquakes for simulation with different controllers. In this paper performances of the structure with and without two controllers are compared and results are discussed.

A Study of Verification on Application of Directional OCR and OCGR for Power System with Small Scale Cogeneration (소형 열병합 발전소의 계통연계시 방향성 과전류 및 지락과전류 계전기의 적용 검증 연구)

  • Lee, Hee-Tae;Cho, Man-Young;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.944-950
    • /
    • 2008
  • When small cogenerators are operated in connected with power system, there are many positive aspects such as the reduction of power plant construction, making a improvement of power security etc. At the same time, there are some negative effects or difficulties such as we should make sure of protective coordination, especially, Actually these are not fault, but it is likely to consider the current as the fault. This is one of major causes of malfunctions for protective relays in power distribution system which is including interconnection point. Thus, in this paper, We showed that the directional protection is necessary to the dispersed generation system which is including connection point. We also executed contingency analysis to find out the magnitude of fault current and direction which are classified by fault points, length of line and kinds of faults using ETAP power system analysis program.

Protective Management System followed Distance Relay characteristics for Transmission Line with the Unified Power Flow Controller (UPFC연계시 거리계전기 동작특성에 따른 보호 관리 시스템)

  • Suh, Jung-Nam;Jung, Chang-Ho;Cho, Jong-Man;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.296-298
    • /
    • 2001
  • This paper represents protective management system for transmission line involving the UPFC(Unified Power Flow Controller) device, which is the most vigorous component of FACTS. The presence of the UPFC significantly affects the line parameters of transmission system, which are also influenced by the distance relay setting. Moreover, depending on the UPFC location and its parameters, zones of setting the distance relay will be changed. Therefore, established protective system should be taken into account the variable injected voltage of the UPFC and constructed data base system.

  • PDF

Delphi Study on the Reduction of Cross-contamination and Improvement of Management System on Firefighting Protection Suit (소방 방화복 교차오염 저감 및 관리체계 개선을 위한 델파이 연구)

  • Kim, Soo Jin;Ham, Seunghon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.182-194
    • /
    • 2022
  • Objectives: This study evaluates and recommends the priority of policy implementation to improve the fire protection clothing management system used by firefighters and the reduction of cross-contamination from contaminated clothing at the scene of a fire. Methods: It consisted of 7 experts and conducted three interviews and two modified Delphi surveys. Through the results of previous research and interviews with experts, a plan to reduce cross-contamination of fire suits and improve the management system was first derived. An improvement plan was presented in the four areas including resources, management, fire protection related work, and laws and regulations, and the priority of policy implementation was derived by analyzing the importance and practicality of the policy at the same time. Results: As a result of the analysis, the first priority was education on the health effects of pollutants at the disaster scene for firefighters, and the second priority was the addition of SOP for the primary decontamination of on-scene personal protective equipment in preparation for the health effects of the disaster scene, and education for fire suppression and rescue workers. The next step was to improve the management system of personal protective equipment such as fire suits and develop a training course for systematic operation. Conclusions: This findings could be used in the implementation of mid- to long-term firefighting policies for the systematic operation and establishment of a systematic management system for personal protective equipment such as fire protective suits.

Power Quality Monitoring Algorithm Using the Protective Relay (보호계전기를 이용한 전기 품질 감시 기법 연구)

  • Choi In. S.;Lee Kang. S.;Choi Myeon. S.;Lim Seong. I.;Lee Seung. J.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.581-588
    • /
    • 2004
  • Power qualify monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. This paper was studied on using data of the protective relay by Power Quality Monitor. This paper was proposed the wave storage condition and monitoring clauses of the protective relay as a power quality monitoring device. The protective relay will have problem to save data for PQM analysis because the protective relay memory is limited. Therefore this paper was proposed new a data compression of data got from the protective relay. This method is wave compression comparison algorithm using the DFT. The compression rate is higher than any other established method. This method can be real time storage. This algorithm is verified using the comparison among other compression rate and proved by Real Time Digital Simulator (RTDS).

Design of digital relay controller on a single chip (디지털 보호 계전기 전용 제어 칩 설계)

  • Seo, Jong-Wan;Jung, Ho-Sung;Kweon, Gi-Beak;Suh, Hui-Suk;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.215-217
    • /
    • 2000
  • Protective relay play a crucial role in the proper operation of a power system, and the reliable transfer of electrical power. This paper deals with the design and implementation of a digital protective relay on a single chip. Implementation on the FPGA(Field Programmable Gate Array) of the chip of digital protective relay. This protective relaying chip monitors the frequency and the voltage and current of the power system. And report the voltage, the current. the frequency, active power and reactive power.

  • PDF

A Development of Software about Short-circuit Calculation and Protective-coordination (고장계산 및 보호협조 판정 소프트웨어 개발)

  • Park, S.C.;Choe, J.H.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.159-162
    • /
    • 2002
  • A software, called touch-one, is developed about the determination of short-circuit values and protective co-ordination in power system. The used solution algorithm reviewed intensively, and the protective co-ordination determination technique presented by using the circuit-breaker's current-limitation characteristic. The protective coordination concerns the behaviour of two devices placed in series in an electrical network, with a short-circuit downstream circuit-breaker. It has two basic principles: First, discrimination which is an increasing requirement of low voltage electrical distribution systems. Second, which is less well known: cascading, which consists of installing a device, whose breaking capacity is less than the three-phase short-circuit current at its terminals and helped by main circuit-breaker. With this software, we can construct a electric-power system which is reliable and economic according to user's purpose.

  • PDF