Assessment of Equipotential Bonding and Electrical Continuity in Buildings (건축물의 등전위 본딩 및 전기적 연속성 평가)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.385-386
    • /
    • 2009
  • This paper deals with assessment of equipotential bonding and electrical continuity in Buinding by investigation on the spot at construction site. The assessment was carried out for continuity of steelwork in reinforced concrete structure, bonding conductor, protective conductor. A new grounding system based on international standards includes unity grounding system, structure grounding utilizing steel reinforced concrete, equipotential bonding, use of surge protective device.

  • PDF

The Welfare Mix Structure in Korea: an Expenditure Study of 2000 (한국 복지혼합의 구조: 2000년도 지출추계를 중심으로)

  • Kim, Jin-Wook
    • 한국사회복지학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.387-411
    • /
    • 2005
  • The purpose of this article is to analyse the expenditure structure of the welfare mix; in order to grasp the holistic feature of the Korean social welfare. Most of all, the article attempts to elaborate the estimation methods of social welfare expenditure by including the components from which has been excluded so far - indirect tax expenditure of the government, nursery payments of households, life insurance pay-outs for survivors, inter-household private income transfers and the value of caring work of the family. In so doing, the article estimates that the total social welfare expenditure including state, enterprise, market, NPOs and family reached at 24.7% of GDP in 2000, which is approximately 2.5 times more than public social welfare expenditure. It implies that non-state, private sectors dominates the structure of social welfare provisions in Korea. In addition, based on the analyses of the expenditure structure, the article defines the main feature of Korea's welfare mix as the 'mixed structure of the welfare mix dominated by the protective family', or 'expanded public sector, relatively limited market, and protective family'. Such a family-dominated welfare mix structure in Korea indicates that the fundamental source of solidarity of the Korean social welfare system is family and, therefore, the welfare regime of Korea can be classified as 'Conservative'.

  • PDF

Screening and Molecular Cloning of a Protective Antigen from the Midgut of Haemaphysalis longicornis

  • Hu, Yonghong;Zhang, Jincheng;Yang, Shujie;Wang, Hui;Zeng, Hua;Zhang, Tiantian;Liu, Jingze
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.3
    • /
    • pp.327-334
    • /
    • 2013
  • Vaccination is considered a promising alternative for controlling tick infestations. Haemaphysalis longicornis midgut proteins separated by SDS-PAGE and transferred to polyvinylidene difluoride (PVDF) membrane were screened for protective value against bites. The western blot demonstrated the immunogenicity of 92 kDa protein (P92). The analysis of the P92 amino acid sequence by LC-MS/MS indicated that it was a H. longicornis paramyosin (Hl-Pmy). The full lenghth cDNA of Hl-Pmy was obtained by rapid amplification of cDNA ends (RACE) which consisted of 2,783 bp with a 161 bp 3' untranslated region. Sequence alignment of tick paramyosin (Pmy) showed that Hl-Pmy shared a high level of conservation among ticks. Comparison with the protective epitope sequence of other invertebrate Pmy, it was calculated that the protective epitope of Hl-Pmy was a peptide (LEEAEGSSETVVEMNKKRDTE) named LEE, which was close to the N-terminal of Hl-Pmy protein. The secondary structure analysis suggested that LEE had non-helical segments within an ${\alpha}$-helical structure. These results provide the basis for developing a vaccine against biting H. longicornis ticks.

A Study on the Characteristic for Abnormal Tension of Overhead Optical Communication Line (가공 광통신선의 이상 장력에 대한 특성 연구)

  • Cho, Hyun-Seob;Han, Kun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.658-663
    • /
    • 2008
  • In this study, we estimated the influence of electrical pole by FEM(Finite Element Method) and developed protective system by designing and interpreting protective system for electrical pole and overhead optical communication line when abnormal strength worked on messenger wire. Protective system did not shed messenger wire under wind pressure and discontent load but did assign a part to preventing rupture of electrical pole and disconnection of optical communication line through automatically shed messenger wire over fixed strength. Structure of protective system analysis by FEM and prove property by measuring tensile strength for practical product.

Methods of Improving Operational Reliability of Oil Well Casing

  • Sergey A. Dolgikh;Irek I. Mukhamatdinov
    • Corrosion Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • Oil well casing leak is caused by contact of casing outer surface with formation electrolyte. It is usually associated with an aquifer with a high salt content or absence of a cement ring behind the casing. The only way to reduce external casing corrosion is through cathodic protection. Through cathodic polarization of casing structure, electron content in crystal lattice and electron density will increase, leading to a potential shift towards the cathodic region. At Tatneft enterprises, cathodic protection is carried out according to cluster and individual schemes. The main criterion for cathodic protection is the size of protective current. For a casing, the protective current is considered sufficient if measurements with a two-contact probe show that the electric current directed to the casing has eliminated all anode sites. To determine the value of required protective current, all methods are considered in this work. In addition, an analysis of all methods used to determine the minimum protective current of the casing is provided. Results show that the method of measuring potential drop along casing is one of the most reliable methods for determining the value of protective current.

The evaluation of penetration protective performance using applied element method for reinforced concrete lining (AEM을 이용한 철근콘크리트 라이닝의 관입 방호성능 평가)

  • Joo, Gun-Wook
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.3
    • /
    • pp.377-396
    • /
    • 2019
  • Explosion after penetration of a warhead in an underground structure generally causes considerable displacement, breakage and extensive damage to the target. Therefore, in order to reduce the damage effect, it is required to design an underground structure protection against penetration. In this study, major factors for improvement of penetration protection performance of reinforced concrete underground structures using applied element method are divided into strength (concrete UCS) and density (concrete thickness, reinforcement layers, reinforcement diameters, reinforcement spacings). Based on these major factors, this study performed numerical analysis of simulation of dynamic response by penetrators under various conditions and analyzed the results. The results of this study are expected to be used as basis materials to improve penetration protection performance of reinforced concrete underground structures.

Effect of Amino Acids on Anoxia-induced Cell Injury

  • Jung, Soon-Hee
    • Biomedical Science Letters
    • /
    • v.7 no.3
    • /
    • pp.127-131
    • /
    • 2001
  • This study was undertaken to examine the effect of amino acids on anoxia-induced cell injury in rabbit renal cortical slices. In order to induce anoxic cell injury, slices were exposed to a 100% $N_2$ atmosphere and control slices were exposed to 100% $O^2$. Irreversible cell injury was estimated by measuring lactate dehydrogenase (LDH) release and alterations in renal cell function were examined by measuring p-aminohippurate (PAH) uptake. Anoxia caused the increase in LDH release in a time-dependent manner. Glycine and glutathione almost completely prevented anoxia-induced LDH release. Of amino acids tested, glycine and alanine exerted the protective effect against anoxia-induced cell injury. However, asparagine with amide side chain, leucine and valine with hydrocarbon side chain, and basic amino acids (lysine, histidine, and arginine) were not effective. Anoxia-induced inhibition of PAM uptake was prevented by glycine. ATP content was decreased by anoxia, which was not affected by glycine. Anoxia-induced depletion of glutathione was significantly prevented by glycine. These results suggest that neutral amino acids with simple structure exert the Protective effect against anoxia-induced cell injury the involvement of specific interaction of amino acids and cell structure.

  • PDF

Ultimate capacity evaluation of Vessel protective structure by quasi-static analysis (의사정적해석을 통한 선박충돌방호공의 극한성능평가)

  • Lee, Gye-Hee;Hong, Kwan-Young;Kim, Se-Jeong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.731-734
    • /
    • 2011
  • 본 연구에서는 강재로 구성된 선박충돌방호공의 최대방호능력을 산정하기 위하여 선박과 충돌방호공을 모델링하고 충돌거동을 해석하였다. 이러한 비선형충돌해석은 매우 큰 요소망과 고도의 비선형성을 려해야하기 때문에 이의 해석비용이 일반적인 해석에 비하여 매우 크므로 해석의 경제성을 확보하기 의사정적해석방법을 이용하여 해석을 수행하였다. 이 과정에서 효율적인 해석을 위한 수치 해석기법이 추가되었다. 해석결과 얻어진 선박과 방호공의 에너지소산곡선을 바탕으로 충돌선박이 교량하부구조에 도달하는 시점을 추정하고 이를 바탕으로 대상선박의 최대충돌속도를 산정하였다.

  • PDF