The evaluation of penetration protective performance using applied element method for reinforced concrete lining  

Joo, Gun-Wook (Agency for Defense Development)
Publication Information
Journal of Korean Tunnelling and Underground Space Association / v.21, no.3, 2019 , pp. 377-396 More about this Journal
Abstract
Explosion after penetration of a warhead in an underground structure generally causes considerable displacement, breakage and extensive damage to the target. Therefore, in order to reduce the damage effect, it is required to design an underground structure protection against penetration. In this study, major factors for improvement of penetration protection performance of reinforced concrete underground structures using applied element method are divided into strength (concrete UCS) and density (concrete thickness, reinforcement layers, reinforcement diameters, reinforcement spacings). Based on these major factors, this study performed numerical analysis of simulation of dynamic response by penetrators under various conditions and analyzed the results. The results of this study are expected to be used as basis materials to improve penetration protection performance of reinforced concrete underground structures.
Keywords
Penetration; Protective design; Reinforced concrete underground structure; AEM(Applied element method); ELS(Extreme loading for structure);
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 ASI (2010), Extreme loading for structures theoretical manual, Applied Science International, pp. 6-27.
2 Asprone, D., Nanni, A., Salem, H., Tagel-Din, H. (2010). "Applied element method analysis of porous GFRP barrier subjected to blast", Advances in Structural Engineering, Vol. 13, No. 1, pp. 153-169.   DOI
3 Ramancharla, P.K., Meguro, K. (2002). "Non-linear static modeling of dip-slip faults for studying ground surface deformation using applied element method", Structural Engineering/Earthquake Engineering of JSCE, Vol. 19, No. 2, pp. 169-178.   DOI
4 Ramancharla, P.K., Meguro, K. (2006). "3D Numerical modelling of faults for study of ground surface deformation using applied element method", Current Science, Vol. 91, No. 8, pp. 1026-1037.
5 Ristic, D., Yamada, Y., Iemura, H. (1986), Stress-strain based modeling of hysteretic structures under earthquake induced bending and varying axial loads, Research Report No. 86-ST-01, School of Civil Engineering, Kyoto University.
6 Salem, H., Mohssen, S., Nishikiori, Y., Hosoda, A. (2016). "Numerical collapse analysis of Tsuyagawa bridge damaged by Tohoku Tsunami", Journal of Performance of Constructed Facilities, Vol. 30, No. 6, pp. 04016065-1-04016065-12.   DOI
7 Seo, G.S. (2005), Protective Engineering, Chung Moon Gak, Paju, pp. 320-334.
8 TM 5-855-1 (1986), Fundamentals of protective design for conventional weapons, Department of Army.
9 Young, C.W. (1997), Penetration equations, SAND97-2426, Sandia National Laboratories.
10 MND (1998), Design criteria for protective structures, Ministry of National Defense.
11 Okamura, H., Maekawa K. (1991). Nonlinear analysis and constitutive models of reinforced concrete, Gihodo Co. Ltd, Tokyo.
12 Kernicky, T.P., Whelan, M.J., Weggel, D.C., Rice, C.D. (2014). "Structural identification and damage characterization of a masonry infill wall in a full-scale building subjected to internal blast load", Journal of Structural Engineering, Vol. 141, No. 1, D4014013-1-D4014013-13.   DOI
13 Cismasiu, C., Ramos, A.P., Moldovan, I.D., Ferreira, D.F., Filho, J.B. (2017). "Applied element method simulation of experimental failure modes in RC shear walls", Computers and Concrete, Vol. 19, No. 4, pp. 365-374.   DOI
14 Hanchak, S.J., Forrestal, M.J., Young, E.R., Ehrgott, J.Q. (1992). "Perforation of concrete slabs with 48 MPa (7 ksi) and 140 MPa (20 ksi) unconfined compressive strengths", International Journal of Impact Engineering, Vol. 12, No. 1, pp. 1-7.   DOI
15 Johns, R.V., Clubley, S.K. (2016). "The influence of structural arrangement on long-duration blast response of annealed glazing", International Journal of Solids and Structures, Vol. 97-98, pp. 370-388.   DOI
16 Meguro, K., Tagel-Din, H. (2000). "Applied element method for structural analysis: Theory and application for linear materials", Structural Engineering/Earthquake Engineering of JSCE, Vol. 17, No. 1, pp. 21-35.
17 Khalil, A., Helmy, H., Tageldin, H., Salem, H. (2017). "Ship impact and nonlinear dynamic collapse analysis of a single well observation platform", In Structures Congress 2017 ASCE, pp. 668-680.
18 Krauthammer, T. (2008), Modern protective structures, CRC Press, pp. 24-38.
19 Ma, S.J., Jang, P.S. (2006), "An investigation into the actual condition of cast in place concrete lining in domestic tunnel", Journal of the Korean Society of Civil Engineers, Vol. 54, No. 12, pp. 68-79.
20 Meguro, K., Tagel-Din, H. (2001). "Applied element simulation of RC structures under cyclic loading", Journal of Structural Engineering, Vol. 127, No. 11, pp. 1295-1305.   DOI