• Title/Summary/Keyword: Protection system

Search Result 5,910, Processing Time 0.035 seconds

Evaluation of Seismic Performance of 2-Story Fire Protection Sprinkler Piping System (화재방호계통 복층구조 스프링클러 파이프라인 내진성능 평가)

  • Jeon, Jun-Tai;Jung, Woo-Young;Ju, Bu-Seog
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.3
    • /
    • pp.458-464
    • /
    • 2014
  • Fire protection (sprinkler) piping system is an essential element for the energy supply and for the protection against the seismic-induced fire during and after an earthquake. The primary objective of this study was to understand the seismic performance of complex two-story piping system installed in a low-rise building subjected to bi-directional and three-directional earthquakes. The result of current study revealed that the displacement of the piping system in accordance with floor level was significantly different due to acceleration-sensitivity but the effect of the piping system due to the vertical direction earthquake was not significant.

Consideration on Royal Guards of Early Chosun Dynasty (조선전기(朝鮮前期) 호위제도(護衛制度)에 관(關)한 고찰(考察))

  • Song, Sang-wk;Kwon, Jeong-hoon
    • Journal of the Society of Disaster Information
    • /
    • v.6 no.2
    • /
    • pp.67-85
    • /
    • 2010
  • The purpose of this consideration is to present fundamental data for understanding and development the historical approach of Korea Protection by re-examining Royal guarding system through the history in Early Chosun Dynasty. This paper initiated from this critical mind seeking to understand the changing phase of Korea Guarding system, and fundamentally to find the future-oriented ways for the Guarding system. The main materials of history in Early Chosun Dynasty were re-examined, investigated and analyzed and the main references are a code of laws and official as well as private documents such as Kukjo-Oreyeui. Guards system for Royal prince has been found in Byung-jeon of Kyungguk-daejon. he Guards organization has dual system, one was Gumgun which was a private military man and the other was Wuibyung which was a Central military man. On the contrary, central military man were normally protected the royale palaces, but when the King come and go they accompanied and protected the King in safety zone. But just in case they did a job as a member of capital protection military affairs. A question of finance was the reason why there had been dual protection system due to financial matter. If it increased number of man it would pay much money, therefore central military man who has no relevance to national finance were supplied as members of military affairs for the protection of king.

A Development of Power Transmission System Protection Database for Korea Electric Power Company (한국전력 송전계통 보호 데어터베이스 구축)

  • An, Yeong-Tae;Lee, Seung-Jae;Choi, Myeon-Song;Kang, Sang-Hee;Kim, Ho-Pyo;Lee, Woon-Hee;Choi, Hong-Suk
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.7
    • /
    • pp.847-854
    • /
    • 1999
  • The setting of protective relays, which is critical to the power system security and reliability, requires a huge volume of data processing and repetitive calculation. Since it has been performed by relay engineers manually, it is vulnerable to human errors, its computerization has been pursued, in which the efficient management of the data is the key to the success. The database for power system protection must accommodate not only the power system network data but also a variety of protective devices. Also its information should be able to be viewed and updated with easy by operators and by computer programs. This paper describes several existing database designs for power system protection, their advantages and disadvantages. Also this paper has identified the required function and designed the database for the KEPCO power system data structure for the benefit of the relay setting process, etc..

  • PDF

Improved Coordination Method for Back-up Protection Schemes Based on IEC 61850 (IEC 61850 기반 후비보호계전시스템 보호협조 개선방안)

  • Kim, Hyung-Kyu;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.43-49
    • /
    • 2011
  • A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome this problem clearly, this paper describes an improved backup protection coordination scheme using an IEC 61850-based distance relay for transformer backup protection. IEC 61850-based IED(Intelligent Electronic Device) and the network system based on the kernel 2.6 LINUX are realized to verify the proposed method. And laboratory tests to estimate the communication time show that the proposed coordination method is reliable enough for the improved backup protection scheme.

The Design of the DC traction Protection system and Device for the test line of Light Rail Transit (경전철 시험선로의 직류 보호시스템 및 보호계전기 설계)

  • Jeon, Y.J.;Kim, J.H.;Baek, B.S.;Kim, N.H.;Lee, B.S.;Ahn, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1229-1231
    • /
    • 2002
  • This paper presents the design of DC protection system of Light Rail Transit system. Especially, the composition and interface for DC Switchgear. Digital protection unit and sort of protection algorithm are focused. DC Switchgear (DCSWGR) for LRT testline consist of 5 different panels with peculiar characteristics are examined. Also Basic actuation principle for DC fault select relay (50F), Line Test Device (LTD), DC Overcurrent(OCR) relay are introduced.

  • PDF

Fuzzy Petri-net Approach to Fault Diagnosis in Power Systems Using the Time Sequence Information of Protection System

  • Roh, Myong-Gyun;Hong, Sang-Eun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1727-1731
    • /
    • 2003
  • In this paper we proposed backward fuzzy Petri-net to diagnoses faults in power systems by using the time sequence information of protection system. As the complexity of power systems increases, especially in the case of multiple faults or incorrect operation of protective devices, fault diagnosis requires new and systematic methods to the reasoning process, which improves both its accuracy and its efficiency. The fuzzy Petri-net models of protection system are composed of the operating process of protective devices and the fault diagnosis process. Fault diagnosis model, which makes use of the nature of fuzzy Petri-net, is developed to overcome the drawbacks of methods that depend on operator knowledge. The proposed method can reduce processing time and increase accuracy when compared with the traditional methods. And also this method covers online processing of real-time data from SCADA (Supervisory Control and Data Acquisition)

  • PDF

An Over Current Protection Scheme for Hybrid Active Power filter

  • Lee Woo-Cheol;Chae Beom-Seok;Hyun Dong-Seok;Lee Taeck-Kie
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.571-575
    • /
    • 2001
  • A protection scheme for hybrid active power filters, which is combined shunt passive filter and small rated series active filter, is presented and analyzed in this paper. The proposed series active power filter operated as a high impedance 'k($\Omega$)' to the fundamental component when over current occurs in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame (SRF) and the third is the method by detecting the input voltage. When the over current occurs in the power distribution system, the proposed scheme protects the series active power filter without additional protection circuits. The validity of proposed protection scheme is investigated through experimental result for the prototype hybrid active power filter system.

  • PDF

Comparison & Analysis of Intrusion Detection System System Protection Profile of NSA and MIC (NSA IDS System PP와 국가기관용 IDS PP 가정사항 비교분석)

  • 김남기;박종오;김지영
    • Convergence Security Journal
    • /
    • v.3 no.2
    • /
    • pp.57-65
    • /
    • 2003
  • A protection profile is the required specification document by consumer groups to specify what security purpose they would like to have in their specialized products. A protection profile assumption is the document that specifies consumer environment in the physical, artificial, network perspective and the contents of intended usage which include usage limitation, the value of latent asset, and additional applications for a TOE (Target of Evaluation). In this paper, we compare the assumptions of the NSA IDS PP and the IDS PP for government.

  • PDF

Ubiquitous Disaster Protection Infrastructure for Underground Space (지하공간 u-방재시스템 구축을 위한 기반 기술)

  • You Chang-Ho;Park Seung-Yeob;Choi Yun-Soo;Kwon Kie-Wook
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.495-499
    • /
    • 2006
  • While the use of large scale underground complex space is increasing currently, this research suggests the methodology of servicing advanced service for civilian and constructing active disaster protection system in order to be free from danger problem of underground complex space by applying new ubiquitous technology. Synchronization between virtual space and real space and construction of ubiquitous disaster protection system arc the core technology. Based on RFID, USN technology, usually, user centered spatial information services are presented. it can be convert to disaster protection system on emergency situation without delay. Through these technology. we can ensure the safety of underground space where the floating population is concentrated in, moreover, utilize for infrastructure that presents various civilian services. Then we can satisfy the increasing civilians desire for safety and welfare and finally, it will contribute to construction of productive city and creation of new conceptual market.

  • PDF

Development of the Digital Protection System for Customer Substation (수용가 변전소의 디지탈 보호 계전 시스템 개발)

  • Kim, Y.N.;Heo, N.J.;Baek, J.H.;Kim, J.K.;Kim, H.Y.;Lee, J.;Kim, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.629-632
    • /
    • 1992
  • This paper deals with Digital Protection System which has been developed at R & D Center of HYUNDAI Electrical Engineering Co.. This system consists of supervisory control part and digital measuring are protection units. RS-485 network connects the units to supervisory control part. This paper go into detail about the specification of each part and the analysis results of digital measuring and protection unit.

  • PDF