• Title/Summary/Keyword: Protection performance

Search Result 2,157, Processing Time 0.033 seconds

A Study on the Development of an Electrostatic Eliminator and Evaluating Method of Explosion-Protection Construction (방폭형 제전기의 개발 및 평가방법에 관한 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.49-54
    • /
    • 2014
  • Electrostatic eliminators are essential in various areas of manufacturing industries to protect electrostatic hazards and to reduce inferior products. For ion sources used in the charge neutralizers, there are corona discharge, soft X-ray, and ultraviolet and glow discharge. Among them, corona discharge is generally used, because the corona discharge can easily and economically produce positive and negative ions including electrons in air at atmospheric pressure. But it is necessary to equip explosion-protection electrostatic eliminators wherever hazardous atmosphere. The electrostatic eliminators and their testing method of explosion-protection type have been developed in this research. The contents and scope of the research as follows; developing the type 'Ex s IIB T4' electrostatic eliminator of explosion-protection; developing the type 'Ex s d IIB T4' electrostatic eliminator of explosion-protection; developing the explosion-protection performance testing method of electrostatic eliminator for using AC power source.

Design of Envelope Protection Algorithm for Helicopters (헬리콥터의 비행영역제한 알고리즘 설계)

  • Ko, Joon Soo;Park, Sungsu;Kim, Kyungmok
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.23 no.2
    • /
    • pp.63-68
    • /
    • 2015
  • This paper presents the algorithm for envelope protection of helicopters. The algorithm consists of two feedback control loops: inner loop and outer loop. As an inner loop control, model following control is designed to meet the ADS-33 handling qualities specification by minimizing the tracking errors between the responses of the actual model and those of the command filter. In order to implement envelope protection, saturation limiter is imposed to command channels in command filter, whose limits are computed corresponding to the envelope limit. Fast model predictive control is designed as an outer loop control to deal with saturation constraints generated by the inner loop envelope protection and also imposed by outer loop envelope protection variables. Simulation results show that the proposed algorithm yields good envelope protection performance.

In Situ Rockfall Tests for Evaluation of Rockfall Protection Fences (국내 낙석방지울타리의 적정성 파악을 위한 현장 실물 실험 및 설계기준 제시)

  • 구호본;박혁진;이경미;김규한;이재욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.629-634
    • /
    • 2000
  • Rockfall protection fence which is used for mitigation of rockfall hazard, has been constructed without consideration of lithology, height and dip angle of rock slope. However, those factors should be considered for the construction of the protection fence. In addition, the protection fence should be evaluated its performance by in-situ test in order to utilize the fence effectively. This is the first full sized rockfall test in Korea. For this test, the rock cut slope whose height is about 20 m and dip angle is 65 $^{\circ}$ has been chosen. Based on the preliminary simulation procedure, four different concrete balls (0.5 ton, 1.0 ton, 2.0 ton and 5.0 ton) were prepared and four different types of protection fence were constructed. The results of this test will be utilized in the establishment of rockfall protection fence construction manual.

  • PDF

Energy Absorbing Capacity for New Rockfall Protection Fence (신개념 낙석방지울타리의 낙석 지지능력 평가)

  • 문영종;정형조;박기준;이인원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.293-298
    • /
    • 2003
  • The rockfall protection fences are installed to reduce rockfall damage in roads side slopes. The energy absorbing capacity of widely used rockfall protection fences is about 50kJ, But in many cases, rockfall protection fences are easily damaged even by a low level of rockfall energy. The objective of this paper is to verify the energy absorbing capacity of rockfall protection fences and investigate the behavior of them by rockfall. The LS-DYNA3D, a finite elements analysis program for dynamic movement of three dimensional objects, is used to perform the numerical simulations. In the result it is shown that rockfall protection fences absorb half of standard absorbing energy or less than it. It is inadquate for the rockfall protection fences to perform the principal function. To improve the performance of the fences, new rockfall proctection fence is proposed and numerical simulation is performed.

  • PDF

Characteristics and Energy Absorbing Capacity for New Rockfall Protection Fence (신개념 낙석방지울타리의 특성 및 성능평가)

  • 문영종;정형조;박기준;이인원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.461-466
    • /
    • 2003
  • The rockfall protection fences are installed to reduce rockfall damage in roads side slopes. The energy absorbing capacity of widely used rockfall protection fences is about 50kJ. But in many cases, rockfall protection fences are easily damaged even by a low level of rockfall energy. The objective of this paper is to verify the energy absorbing capacity of rockfall protection fences and investigate the behavior of them by rockfall. The LS-DYNA3D, a finite elements analysis program for dynamic movement of three dimensional objects, is used to perform the numerical simulations In the result, it is shown that rockfall protection fences absorb half of standard absorbing energy or less than it. It is inadquate for the rockfall protection fences to perform the principal function. To improve the performance of the fences, new rockfall proctection fence is proposed and numerical simulation is performed.

  • PDF

Flush Optimizations to Guarantee Less Transient Traffic in Ethernet Ring Protection

  • Lee, Kwang-Koog;Ryoo, Jeong-Dong
    • ETRI Journal
    • /
    • v.32 no.2
    • /
    • pp.184-194
    • /
    • 2010
  • Ethernet ring protection (ERP) technology, which is defined in ITU-T Recommendation G.8032, has been developed to provide carrier grade recovery for Ethernet ring networks. However, the filtering database (FDB) flush method adopted in the current ERP standard has the drawback of introducing a large amount of transient traffic overshoot caused by flooded Ethernet frames right after protection switching. This traffic overshooting is especially critical when a ring provides services to a large number of clients. According to our experimental results, the traditional FDB flush requires a link capacity about sixteen times greater than the steady state traffic bandwidth. This paper introduces four flush optimization schemes to resolve this issue and investigates how the proposed schemes deal with the transient traffic overshoot on a multi-ring network under failure conditions. With a network simulator, we evaluate the performance of the proposed schemes and compare them to the conventional FDB flush scheme. Among the proposed methods, the extended FDB advertisement method shows the fastest and most stable protection switching performance.

Pspice Simulation Model of a ZnO Varistor for Lightning Surge Current (뇌서지 전류에 대한 산화아연바리스터의 Pspice 시뮬레이션 모델)

  • Lee, B.H.;Kong, Y.H.;Lee, K.O.;Kang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1675-1677
    • /
    • 1998
  • It is currently increasing to use surge protection devices in the protection of various electronic circuits from the transient overvoltages such as lightning strikes and switching surges. For this reason, the simulation methods, which can easily predict the protection performance of the devices, are strongly required in order to design the adequate surge protection circuits in lightning surge cut-off performance and economic aspects. This paper deals with ZnO varistor modeling method for designing a surge protection circuit and suggests the Pspice simulation model which takes the characteristic of varying clamping voltage into consideration during the time-to-crest, in range of $8{\sim}30{\mu}s$, of surge current applied to a ZnO varistor. The ZnO varistor Pspice simulation data introduced in this paper has produced almost same values as the measured results experimentally.

  • PDF

A Study for the Designing and Efficiency Measuring Methods of Integrated Multi-level Network Security Domain Architecture (Multi-level 네트워크의 보안 도메인을 위한 통합 아키텍쳐 설계 및 효율성 측정방법 연구)

  • Na, Sang Yeob;Noh, Si Choon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.4
    • /
    • pp.87-97
    • /
    • 2009
  • Internet network routing system is used to prevent spread and distribution of malicious data traffic. This study is based on analysis of diagnostic weakness structure in the network security domain. We propose an improved integrated multi-level protection domain for in the internal route of groupware. This paper's protection domain is designed to handle the malicious data traffic in the groupware and finally leads to lighten the load of data traffic and improve network security in the groupware. Infrastructure of protection domain is transformed into five-stage blocking domain from two or three-stage blocking. Filtering and protections are executed for the entire server at the gateway level and internet traffic route ensures differentiated protection by dividing into five-stage. Five-stage multi-level network security domain's malicious data traffic protection performance is better than former one. In this paper, we use a trust evaluation metric for measuring the security domain's performance and suggested algorithm.

Design of ESD Protection Circuits for High-Frequency Integrated Circuits (고주파 집적회로를 위한 ESD 보호회로 설계)

  • Kim, Seok;Kwon, Kee-Won;Chun, Jung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.8
    • /
    • pp.36-46
    • /
    • 2010
  • In multi-GHz RF ICs and high-speed digital interfaces, ESD protection devices introduce considerable parasitic capacitance and resistance to inputs and outputs, thereby degrading the RF performance, such as input/output matching, gain, and noise figure. In this paper, the impact of ESD protection devices on the performance of RF ICs is investigated and design methodologies to minimize this impact are discussed. With RF and ESD test results, the 'RF/ESD co-design' method is discussed and compared to the conventional RF ESD protection method which focuses on minimizing the device size.

Measurements and Assessments on Shielding Performance of FCTC10 60Co Transport Container

  • Zhuang, Dajie;Zhang, Guoqing;Li, Guoqiang;Wang, Renze
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.310-314
    • /
    • 2016
  • Background: FCTC10 container is designed to transport $^{60}Co$ radioactive sources used in irradiation industry. It belongs to Type B(U) Category III (yellow) package when being loaded with a $^{60}Co$ source of $1.8{\times}10^5$ Ci. Materials and Methods: The container is constituted of shielding container, basket, protective cover and bracket. Shielding ability is provided mainly by stainless steel shells, tungsten alloy and lead among steel shells. Radiation level around the container has been calculated with both Monte Carlo simulations and measurements. Results and Discussion: It is proven that the shielding performance of the container fulfills the requirements in GB11806-2004 (Regulations for the safe transport of radioactive material, China Standard Press). Exposure doses to workers and to critical groups of public were calculated based on hypothetical exposure scene according to transport practice experience. Conclusion: The results show that doses to workers and public are less than the constraint dose considered in design, and the radiation level would be increased less than a factor of 2 under design basis accidents.