• Title/Summary/Keyword: Protection net

Search Result 315, Processing Time 0.018 seconds

IDENTIFICATION OF SAFETY CONTROLS FOR ENGINEERING-SCALE PYROPROCESS FACILITY

  • MOON, SEONG-IN;SEO, SEOK-JUN;CHONG, WON-MYUNG;YOU, GIL-SUNG;KU, JEONG-HOE;KIM, HO-DONG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.7
    • /
    • pp.915-923
    • /
    • 2015
  • Pyroprocess technology has been considered as a fuel cycle option to solve the spent fuel accumulation problems in Korea. The Korea Atomic Energy Research Institute, Daejeon, Korea has been studying pyroprocess technology, and the conceptual design of an engineering-scale pyroprocess facility, called the Reference Engineering-scale Pyroprocess Facility, has been performed on the basis of a 10 ton heavy metal throughput per year. In this paper the concept of Reference Engineering-scale Pyroprocess Facility is introduced along with its safety requirements for the protection of facility workers, collocated workers, the off-site public, and the environment. For the identification of safety structures, systems, and components and/or administrative controls, the following activities were conducted: (1) identifying hazards associated with operations; (2) identifying potential events associated with these hazards; and (3) identifying the potential preventive and/or mitigative controls that reduce the risk associated with these accident events. This study will be used to perform a safety evaluation for accidents involving any of the hazards identified, and to establish safety design policies and propose a more definite safety design.

ESTIMATION OF THE POWER PEAKING FACTOR IN A NUCLEAR REACTOR USING SUPPORT VECTOR MACHINES AND UNCERTAINTY ANALYSIS

  • Bae, In-Ho;Na, Man-Gyun;Lee, Yoon-Joon;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.41 no.9
    • /
    • pp.1181-1190
    • /
    • 2009
  • Knowing more about the Local Power Density (LPD) at the hottest part of a nuclear reactor core can provide more important information than knowledge of the LPD at any other position. The LPD at the hottest part needs to be estimated accurately in order to prevent the fuel rod from melting in a nuclear reactor. Support Vector Machines (SVMs) have successfully been applied in classification and regression problems. Therefore, in this paper, the power peaking factor, which is defined as the highest LPD to the average power density in a reactor core, was estimated by SVMs which use numerous measured signals of the reactor coolant system. The SVM models were developed by using a training data set and validated by an independent test data set. The SVM models' uncertainty was analyzed by using 100 sampled training data sets and verification data sets. The prediction intervals were very small, which means that the predicted values were very accurate. The predicted values were then applied to the first fuel cycle of the Yonggwang Nuclear Power Plant Unit 3. The root mean squared error was approximately 0.15%, which is accurate enough for use in LPD monitoring and for core protection that uses LPD estimation.

Cyber Security Risk Evaluation of a Nuclear I&C Using BN and ET

  • Shin, Jinsoo;Son, Hanseong;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.517-524
    • /
    • 2017
  • Cyber security is an important issue in the field of nuclear engineering because nuclear facilities use digital equipment and digital systems that can lead to serious hazards in the event of an accident. Regulatory agencies worldwide have announced guidelines for cyber security related to nuclear issues, including U.S. NRC Regulatory Guide 5.71. It is important to evaluate cyber security risk in accordance with these regulatory guides. In this study, we propose a cyber security risk evaluation model for nuclear instrumentation and control systems using a Bayesian network and event trees. As it is difficult to perform penetration tests on the systems, the evaluation model can inform research on cyber threats to cyber security systems for nuclear facilities through the use of prior and posterior information and backpropagation calculations. Furthermore, we suggest a methodology for the application of analytical results from the Bayesian network model to an event tree model, which is a probabilistic safety assessment method. The proposed method will provide insight into safety and cyber security risks.

Radiation testing of low cost, commercial off the shelf microcontroller board

  • Fried, Tomas;Di Buono, Antonio;Cheneler, David;Cockbain, Neil;Dodds, Jonathan M.;Green, Peter R.;Lennox, Barry;Taylor, C. James;Monk, Stephen D.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3335-3343
    • /
    • 2021
  • The impact of gamma radiation on a commercial off the shelf microcontroller board has been investigated. Three different tests have been performed to ascertain the radiation tolerance of the device from a nuclear decommissioning deployment perspective. The first test analyses the effect of radiation on the output voltage of the on-board voltage regulator during irradiation. The second test evaluated the effect of gamma radiation on the voltage characteristics of analogue and digital inputs and outputs. The final test analyses the functionality of the microcontroller when using an external, shielded voltage regulator instead of the on-board voltage regulator. The results suggest that a series of latch-ups occurs in the microcontroller during irradiation, causing increased current drain which can damage the voltage regulator if it does not have short-circuit protection. The analogue to digital conversion functionality appears to be more sensitive to gamma radiation than digital and analogue output functionality. Using an external, shielded voltage regulator can prove beneficial when used for certain applications. The collected data suggests that detaching the voltage regulator can extend the lifespan of the platform up to approximately 350 Gy.

An investigation of the nuclear shielding effectiveness of some transparent glasses manufactured from natural quartz doped lead cations

  • Kassem, Said M.;Ahmed, G.S.M.;Rashad, A.M.;Salem, S.M.;Ebraheem, S.;Mostafa, A.G.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.2025-2037
    • /
    • 2021
  • The influence of lead cations on natural quartz (QZ) from Egypt as a glass shielding material for the composition with nominal formula (10Na2O - (90 - x) QZ - xPbO (where x = 30, 35, 40, 45 and 50 mol %)) was examined. The studied samples are synthesized via the melt quenching method at 1050 ℃. The X-ray diffraction XRD patterns were confirmed the glass nature for studied samples. Moreover, the optical properties, and the transparency for all compositions were examined by UV-Vis spectroscopy. Also, the major elemental composition of the natural quartz were estimated via the X-ray fluorescence (XRF) technique. Further, the density and molar volume were determined. Furthermore, the nuclear shielding parameters such as, mass attenuation coefficient, effective atomic number, electronic density, the total atomic, and electronic cross sections as well as the mean free path, and the half value layer with different gamma ray energies (81 keV-1407 keV) were calculated. Besides, the results showed that the shielding behavior towards the gamma ray radiation for all glass samples was increased as the increment in PbO concentration in the glass system.

Performing angiographic intervention with a femoral entry shield: Element analysis microscopy and hand dose reduction for interventional radiologist

  • Law, Martin;Ng, Dickon H.L.;Yoon, Do-Kun;Djeng, Shih-Kien
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1318-1322
    • /
    • 2021
  • To unveil and delineate the elements applicable to the radiation protection of a femoral entry shield, calculate its mass attenuation coefficient, and demonstrate its dose reduction efficacy for interventional radiologist performing transarterial embolization (TAE) of ruptured hepatocellular carcinoma (rHCC). The lead equivalency of the shield was firstly validated. Electron microscopy was used to confirm the femoral entry shield being lead-free and to analyze the elemental content, with which the mass attenuation coefficient of the shield was calculated. An adult phantom, irradiated at the upper abdomen to simulate the TAE of rHCC, was used together with a dosimeter attached to the palm of a hand phantom. The dose rates at the hand phantom were measured, with the rHCC clinical protocol, without and with the femoral entry shield placed over the right femoral access site of the adult phantom. Without using the shield, the average hand dose rate was measured to be 0.325 µSv/sec. While using the shield, it was determined to be 0.110 µSv/sec. There was significant 66% dose reduction to the hand dose of IRs performing angiographic intervention with the femoral entry shield.

A new perspective towards the development of robust data-driven intrusion detection for industrial control systems

  • Ayodeji, Abiodun;Liu, Yong-kuo;Chao, Nan;Yang, Li-qun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2687-2698
    • /
    • 2020
  • Most of the machine learning-based intrusion detection tools developed for Industrial Control Systems (ICS) are trained on network packet captures, and they rely on monitoring network layer traffic alone for intrusion detection. This approach produces weak intrusion detection systems, as ICS cyber-attacks have a real and significant impact on the process variables. A limited number of researchers consider integrating process measurements. However, in complex systems, process variable changes could result from different combinations of abnormal occurrences. This paper examines recent advances in intrusion detection algorithms, their limitations, challenges and the status of their application in critical infrastructures. We also introduce the discussion on the similarities and conflicts observed in the development of machine learning tools and techniques for fault diagnosis and cybersecurity in the protection of complex systems and the need to establish a clear difference between them. As a case study, we discuss special characteristics in nuclear power control systems and the factors that constraint the direct integration of security algorithms. Moreover, we discuss data reliability issues and present references and direct URL to recent open-source data repositories to aid researchers in developing data-driven ICS intrusion detection systems.

Comparison of nano/micro lead, bismuth and tungsten on the gamma shielding properties of the flexible composites against photon in wide energy range (40 keV-662 keV)

  • Asgari, Mansour;Afarideh, Hossein;Ghafoorifard, Hassan;Amirabadi, Eskandar Asadi
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4142-4149
    • /
    • 2021
  • In the radiation protection application, the metal-polymer composites have been developed for their radiation shielding properties. In this research, the elastomer composites doped by 10 ㎛ and 100nm size of lead, bismuth and tungsten particles as filler with 30 and 60 wt percentages were prepared. To survey the shielding properties of the polymer composites using gamma-ray emitted from 152Eu and 137Cs sources, the gamma flux was measured by using NaI(Tl) detector, then the linear attenuation coefficient was calculated. Also, the Monte Carlo simulation (MCs) method was used. The results showed a direct relationship between the linear attenuation coefficients of the absorbent and filler ratio. Also, the decrease in the particle size of the shielding material in each weight percentage improved the radiation shielding features. When the dimension of the particles was in the order of nano-size, more attenuation was achieved. At low energies used for medical diagnostic X-ray applications due to the predominance of the photoelectric effect, bismuth and lead were suitable selection as filler.

Pulsed laser welding of Zr-1%Nb alloy

  • Elkin, Maxim A.;Kiselev, Alexey S.;Slobodyan, Mikhail S.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.776-783
    • /
    • 2019
  • Laser welding is usually a more effective method than electron-beam one since a vacuum chamber is not required. It is important for joining Zr-1%Nb (E110) alloy in a manufacturing process of nuclear fuel rods. In the present work, effect of energy parameters of pulsed laser welding on properties of butt joints of sheets with a thickness of 0.5 mm is investigated. The most efficient combination has been found (8-11 J pulse energy, 10-14 ms pulse duration, 780-810 W peak pulse power, 3 Hz pulse frequency, 1.12 mm/s welding speed). The results show that ultimate strength under static loading can not be used as a quality criterion for zirconium alloys welds. Increased shielding gas flow rate does not allow to protect weld metal totally and contributes to defect formation without using special nozzles. Several types of imperfections of the welds have been found, but the major problem is branching microcracks on the surface of the welds. It is difficult to identify the cause of their appearance without additional research on improving the welding zone protection (gas composition and flow rate as well as nozzle configuration) and studying the hydrogen content in the welds.

The Financial Burden of Catastrophic Health Expenditure Among Older Women Living Alone (여성독거노인가구의 과부담 의료비 지출에 관한 연구)

  • Shin, Serah
    • Journal of Family Resource Management and Policy Review
    • /
    • v.23 no.1
    • /
    • pp.17-34
    • /
    • 2019
  • Older women who live alone are among society's most vulnerable people, since they experience increased risk of multiple chronic diseases and have limited financial protection. This can lead older women living alone to catastrophic health expenditure(CHE), which is defined as a healthcare expenditure that exceeds a certain portion of a household's ability to pay. Using the Korean Longitudinal Study of Ageing(KLoSA), this study investigated the incidence of CHE among older women living alone and identified the factors related to this incidence. Applying health expenditure thresholds of 10%, 20%, 30% and 40% of ability to pay, the proportions of those with CHE were 41.3%, 22.9%, 14.6%, and 9.4%, respectively. Logistic regression models were used to identify factors related to CHE incidence, which include demographics, income, the number of chronic diseases, perceived health status, and health insurance type. The results show that the health care safety net in South Korea is insufficient for older women living alone. The findings can guide policymakers in improving healthcare and welfare policies to protect people from catastrophic payments. Particularly, welfare policies should be established for poor non-recipients who are not included within the benefits scope of the National Basic Livelihood Security System due to the unrealistic criteria of income recognition and family support obligation.