• 제목/요약/키워드: Protection facility

검색결과 406건 처리시간 0.031초

LNG를 사용하는 설비에서의 폭발위험장소 적용 및 구분에 대한 제도/기술적 접근방안 (Technical/Systemic Approach to Safety Assesment of Thermoprocessing Equipment Consuming LNG for Classification of Hazardous Area)

  • 최상원
    • 한국안전학회지
    • /
    • 제26권5호
    • /
    • pp.33-40
    • /
    • 2011
  • In the hazardous areas where explosive liquids, vapors and gases exist, electrical apparatus/equipment should have explosion-proof construction. The consuming of liquefied natural gas(LNG) has markedly increased in the industrial field, especially in aspect of some thermoprocessing equipment, boiler, dryer, furnace, annealer, kiln, regenerative thermal oxidizer(RTO) and so on. Because it has many merits, clean fuel, safety, no transportation/storage facility and so on. It is strongly recommend that the classification of hazards has to be decided to prevent and protect explosion which may occur in thermoprocessing equipment. In this paper, the operated thermoprocessing equipments in industrial area investigated and explosion risk assessment about LNG leakage from its facilities was performed through numerical calculation and computer simulation. Finally, we suggest the systemic/technical approach for safety assessments of thermoprocessing equipments consumed LNG fuel which are specially subjected to classification of hazardous area.

철도 선로변 유지보수 작업자 및 모터카 안전을 위한 양방향 안전설비 동작 메커니즘 연구 (A Study on Bidirectional Detection Safety Equipment Mechanism for Casualty Accidents Protection of Railroad Workers and Motorcars)

  • 황종규;조현정
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.384-389
    • /
    • 2010
  • Workers maintaining at the railroad trackside may collide with the train since they cannot recognize the train approaching because of the sensory block phenomenon occurred due to their long hours of continued monotonous maintenance work. To reduce these casualty accidents of maintenance workers working at the trackside of railroad, we developed the wireless communication-based safety equipment for preventing accidents. The motor-cars for maintaining trackside facility have unique operational patterns suitable for urban environment. The several mechanism for developed safety equipment are represented in this paper.

정보통신설비용 서지보호기의 적절한 설치방법 (Proper Installation Methods of SPDs for Information-Oriented and Computerized Equipments)

  • 이복희;강성만;이동문;구본완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.194-196
    • /
    • 2002
  • This paper deals with a proper installation methods of SPDs for information-oriented and computerized equipments. Since the information and computerized equipments have AC power lines and communication lines, the potential difference by lightning surge occurs between grounding points of the AC power lines and subscriber protectors, and it causes the flashover and damage. So, we have investigated the effect of the installation methods of surge protectors on the control of overvoltages, using a real-sized test circuit with a customer's facility. As a consequence, it was confirmed that the protection methods by installation of SPDs on the neighbor branch circuit was effective.

  • PDF

폐기물 처리시설 홍보실내 화재 및 피난에 관한 연구 (A Study on Fire and Evacuation in the Public Relations Room of Waste Treatment Facilities)

  • 이재영;전용한
    • 대한안전경영과학회지
    • /
    • 제23권1호
    • /
    • pp.17-22
    • /
    • 2021
  • The public relations room of the waste disposal facility is a space that can be visited by a large number of unevaluated personnel. Therefore, it is essential to design against fire, and research on fire and evacuation is essential. In this study, in order to evaluate the safety of the occupants in the event of fire and evacuation based on the life safety standards of occupants, the increase in risk due to heat, visible distance, and toxic gases on a plane 1.8m from the floor, which is the limit of breathing of the evacuee, over time. It was analyzed by location. As a result, the RSET of the P-01 exit was 93.0 seconds and the ASET was 272.6 seconds, the RSET of the P-02 exit was 45.8 seconds, the ASET was 147.7 seconds, the RSET of the P-03 exit was 106 seconds, and the ASET was 182.9 seconds.

강섬유 종류에 따른 시멘트 복합체의 전기전도도 측정에 대한 실험적 연구 (An Experimental Study on the Measurement of Electrical Conductivity of Cementitious Composites According to the Type of Steel Fiber)

  • 이예찬;김규용;남정수;이상규;서동균;유하민
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.191-192
    • /
    • 2020
  • The purpose of this study is to measure the electrical conductivity of cementitious composites as an early step to obtain shielding performance by mixing various type of steel fiber into cementitious composites, the main building material of protection facility, to shield electromagnetic pulse (EMP) damage. Fiber such as conductors as amorphous metallic fiber, hooked steel fiber, and smooth steel fiber are mixed into cementitious composites to give electrical conductivity and measure the impedance of concrete using LCR meter. By doing this, the electrical conductivity of each type of steel fiber reinforced cementitious composites (FRCC) is compared.

  • PDF

효과적인 중성자 차폐를 위한 경량 연자성 물질 활용방안 연구 (Study on the Application of Soft Magnetic Material for Effective Neutron Shielding)

  • 김영찬;강창우
    • 방사선산업학회지
    • /
    • 제17권1호
    • /
    • pp.93-100
    • /
    • 2023
  • This study analyzes the neutron shielding performance of Soft Magnetic Material and proposes a military application. In general, the military protection facility has been constructed with thick concrete, so Soft Magnetic Material, consisting of boron, was used with concrete in this study. To do so, Monte-Carlo N-Particle (MCNP) was applied to simulate the Watt-fission neutron spectrum of 235U and 239Pu. As a result, a configuration of polyethylene and Soft Magnetic Material is evaluated about four times better than borated polyethylene concerning the atomic weight of boron inside each shielding material. Also, when a nuclear weapon explosion is simulated in MCNP, 1 mm of Soft Magnetic Material with 20 cm of concrete shows about 55% more additional neutron shielding performance compared to when Soft Magnetic Material is not used. In this work, the neutron shielding performance of Soft Magnetic Material could be identified and Soft Magnetic Material would be useful for neutron shielding if applicable to concrete structure.

침수지역에서 수·변전설비 침수방지시설에 관한 현장실태 조사 및분석 (The Investigation and Analysis of Field Condition on Flood Protection Equipment of Transformer Vault in Flood Area)

  • 김기현;김종민;김선구;황광수
    • 조명전기설비학회논문지
    • /
    • 제19권4호
    • /
    • pp.85-90
    • /
    • 2005
  • 매년 집중 호우 및 태풍${\cdot}$해일 등에 의해 도심 저지대 및 해안가 저지대의 수${\cdot}$변전설비 침수가 많이 발생을 하고 있다. 수${\cdot}$변전설비가 침수되면 전력 수급에 큰 문제를 발생시키고, 복구 시간이 많이 걸리기에 그에 따른 경제적 손실 발생과 침수된 설비에 의한 감전사고 발생 및 물적 피해가 발생을 한다. 따라서 이를 방지하기 위한 상습 침수지역에서의 수${\cdot}$변전설비 시설에 대한 시설 방안이 제시되어야 할 것이다. 이미 외국의 경우 전기설비의 중요성을 인식하여 침수지역에서의 전기설비 시설에 대하여 규정을 하고 있다. 본 논문은 국내에서 가장 많이 분포되어 있는 22.9[kV] 수${\cdot}$변전설비 시설 현황 및 침수방지 대책에 대한 현장실태조사를 하였고, 미국, 영국 등 국외 전기설비 침수방지 대책에 관한 규정들을 비교${\cdot}$분석하였다. 분석 결과 국내의 침수방지 대책이 현장 및 제도적으로 미비하였다. 따라서 본 논문은 현장실태조사 결과와 국외 침수방지대책에 관한 규정 분석을 토대로 상습침수지역에서의 수${\cdot}$변전설비 침수방지 대책을 제시하였다. 또한 본 연구 내용은 국내 관련 법 개정(안)을 제시하는데 근거 자료로 사용될 것이다.

분산전원이 연계된 배전계통의 양방향 구간개폐기의 동작 알고리즘에 관한 연구 (A study on the Operation Algorithm for Bi-directional Sectonalizer in Distribution System Interconnected with Distributed Generations)

  • 윤기갑;정점수;안태풍;노대석
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.1802-1809
    • /
    • 2009
  • 기존의 배전계통은 전원 측인 배전용변전소에서 부하 측인 수용가로 전력을 단 방향으로 공급하는 것이 일반적이지만, 태양광과 풍력 등과 같은 분산전원이 배전계통에 연계되는 경우에는 분산전원에서 발생하는 전력이 계통으로 공급되는 역 조류가 발생하여 기존의 시스템과 달리 양방향으로 전력이 공급되게 된다. 이러한 양방향 전력공급은 기존의 시스템에 악 영향을 끼칠 수 있는데, 배전선로에 설치되어 있는 보호협조기기에 심각한 문제점을 발생시킬 수 있다. 특히 기존의 구간 개폐기는 주 전원 측의 전력만 감지할 뿐, 분산전원 측의 역 조류 감지 및 보호를 하지 못해 오동작을 일으킬 가능성이 존재한다. 이러한 경우 분산전원의 단독 운전뿐만 아니라 배전계통과 분산전원의 비동기 투입에 의하여 배전계통에 악영향을 끼칠 수도 있다. 따라서 본 논문에서는 이에 대한 대책으로서 역 조류를 감지하는 구간 개폐기의 양방향 동작 알고리즘을 제시하고, 이에 대한 성능을 확인하기 위하여, 배전계통의 대표적인 해석 S/W인 PSCAD/EMTDC를 이용하여 시뮬레이션을 수행하였다. 또한 보호기기 모의시험 장치를 제작하여 하드웨어적인 시험 결과를 분석하여, 본 논문에서 제안한 구간개폐기의 양방향 동작 알고리즘에 대한 효용성과 타당성을 확인하였다.

함안 용산리 함안층 새발자국 화석산지의 보존과학적 진단 및 평가 (Conservation Scientific Diagnosis and Evaluation of Bird Track Sites from the Haman Formation at Yongsanri in Haman, Korea)

  • 이규혜;박준형;이찬희
    • 헤리티지:역사와 과학
    • /
    • 제52권3호
    • /
    • pp.74-93
    • /
    • 2019
  • 함안 용산리 함안층 새발자국 화석산지(천연기념물 제222호)에서는 Koreanaornis hamanensis와 Jindongornipes kimi로 명명된 두 종의 새발자국이 발견되었으며, 용각류 발자국과 생흔화석 Cochlichnus도 보고되었다. 특히 Koreanaornis hamanensis는 세계에서 두 번째로 기록된 새발자국 화석종으로 학술적 가치가 매우 뛰어나다. 이 일대는 구들장용 판석의 채석장이었으며, 1969년에 세계적 희귀 화석지로 알려지면서 크게 훼손되어, 현재는 지정 당시의 25% 정도가 잔존한다. 함안층은 경상누층군의 하양층군에 속하며 주로 적회색의 미사암과 흑색의 이암이 교호하는 암상을 보인다. 미사암과 이암의 경계는 점이적이며, 연흔과 건열 등의 퇴적 구조가 뚜렷하다. 연구 지역의 퇴적암은 퇴적순서와 구조 및 암상에 따라 총 7개의 지층으로 구분되며, 새발자국 화석은 최상부층에서 나타난다. 비파괴 손상도 평가 결과, 화학적 생물학적 손상은 7개 지층에서 모두 매우 낮게 나타났다. 물리적 손상도의 경우 박락 0.49%, 박리 0.04%, 탈락 0.28%로 매우 낮은 손상률을 보였다. 그러나 절리 등 불연속면의 균열지수는 6.20으로 비교적 높으며, 배면과 북서측의 표면은 하등생물의 피복이 심하여 지층의 단면을 중심으로 염에 의한 백화현상이 관찰된다. 화석산지의 초음파 물성은 전반적으로 중간풍화단계(MW)를 보였다. 특히 공룡발자국이 있는 남서측 부근이 상대적으로 신선하며, 보호각 기둥 주위로 풍화가 진전된 양상을 보였다. 이 화석산지에 발달한 불연속면은 5종류로서 가장 높은 점유율을 보이는 불연속면은 층리면이다. 평사투영으로 사면의 안정성을 분석한 결과, 평면 및 쐐기파괴에는 안정적이지만 전도파괴의 가능성이 있는 것으로 나타났다. 이 화석산지의 종합적인 손상 정도 및 안정성은 양호한 것으로 판단되나, 화석층의 물리화학적 풍화와 보호각 기둥과 접하는 모르타르의 백화현상 등은 제어하기 어려운 상태로 보여, 지속적인 모니터링과 보존처리 및 관리가 수행되어야 할 것이다.

PWR 사용후핵연료 중간저장시설의 몬테칼로 차폐해석 방법에 대한 계산효율성 개선방안 연구 (Development for Improvement Methodology of Radiation Shielding Evaluation Efficiency about PWR SNF Interim Storage Facility)

  • 김태만;서명환;조천형;차길용;김순영
    • Journal of Radiation Protection and Research
    • /
    • 제40권2호
    • /
    • pp.92-100
    • /
    • 2015
  • 경수로 사용후핵연료 건식 중간저장시설의 방사선영향평가 효율성 개선을 목적으로 '선원항 지정방법에 따른 민감도 평가', '2-Step 계산'기법 개발 및 '냉각기간 이득효과' 적용에 따른 방사선 영향평가를 수행하였다. 본 연구에서는 저장건물의 용기배열 순서에 따라 순차적으로 선원항을 지정하여 직접선량에 미치는 민감도를 평가하였으며, 차폐건물 외벽에서의 방사선량은 내벽과 인접한 최근접 2개 열에 의한 영향이 지배적임을 확인하였다. 또한, 저장시설에 차폐 건물이 도입될 경우, 막대한 전산해석 시간을 감소시키기 위해 '2-Step 계산'기법을 수립하여 평가한 결과는 절반가량의 해석시간으로 직접(1-Step) 계산결과와 유사한 결과를 도출하였다. 마지막으로, 저장시설에 순차적으로 저장되는 저장용기의 보관기간을 사용후핵연료의 실제 냉각기간을 적용하면 건물 외벽에서의 방사선량이 냉각기간을 모두 동일하게 설정한 계산값에 비해 40% 정도 낮게 평가됨을 확인하였다. 본 연구는 중간저장시설의 방사선 영향평가를 위한 몬테칼로 차폐해석 방법의 효율성을 향상시키고자 수행되었으며, 좀 더 다양한 사례에 대한 평가를 통하여 신뢰성을 향상시킨다면 저장시설의 설계 및 부지경계 기준설정에 활용할 수 있을 것이다.