• 제목/요약/키워드: Protection facility

검색결과 404건 처리시간 0.029초

Application on the New Technology of Construction Structures Disaster Protection Management based on Spatial Information

  • Yeon, Sangho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권3호
    • /
    • pp.136-145
    • /
    • 2018
  • The disaster monitoring technique by combination of the measurement method and the fine precision of the sensor collecting the satellite-based information that can determine the displacement space is available in a variety of diagnostic information and the GIS/GNSS by first sensor it is being requested from them. Be large and that the facility is operated nationally distributed torsional displacement of the terrain and facilities caused by such natural disasters progress of various environmental factors and the surroundings. To diagnose this spatial information, which contains the various sensors and instruments tracks the precise fine displacement of the main construction structures and the first reference in the Geospatial or more three-dimensional detailed available map and location information using the installed or the like bridges and tunnels produced to a USN/IoT change at any time, by combining the various positioning analysis of mm-class for the facility main area observed is required to constantly in the real time information of the USN/IoT environment sensor, and to utilize this as a precise fine positioning information by UAV/Drone to the precise fine displacement of the semi-permanent infrastructures. It managed to be efficient management by use of new technologies, analyzing the results presented to a method capable of real-time monitoring for a large structure or facility to construction disaster prevention.

Path planning in nuclear facility decommissioning: Research status, challenges, and opportunities

  • Adibeli, Justina Onyinyechukwu;Liu, Yong-kuo;Ayodeji, Abiodun;Awodi, Ngbede Junior
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3505-3516
    • /
    • 2021
  • During nuclear facility decommissioning, workers are continuously exposed to high-level radiation. Hence, adequate path planning is critical to protect workers from unnecessary radiation exposure. This work discusses recent development in radioactive path planning and the algorithms recommended for the task. Specifically, we review the conventional methods for nuclear decommissioning path planning, analyze the techniques utilized in developing algorithms, and enumerate the decision factors that should be considered to optimize path planning algorithms. As a major contribution, we present the quantitative performance comparison of different algorithms utilized in solving path planning problems in nuclear decommissioning and highlight their merits and drawbacks. Also, we discuss techniques and critical consideration necessary for efficient application of robots and robotic path planning algorithms in nuclear facility decommissioning. Moreover, we analyze the influence of obstacles and the environmental/radioactive source dynamics on algorithms' efficiency. Finally, we recommend future research focus and highlight critical improvements required for the existing approaches towards a safer and cost-effective nuclear-decommissioning project.

북한 우라늄 농축시설로 인한 한반도에서의 공기중 우라늄 입자 농도 예측 (Estimation of Uranium Particle Concentration in the Korean Peninsula Caused by North Korea's Uranium Enrichment Facility)

  • 곽성우;강한별;신중기;이정현
    • Journal of Radiation Protection and Research
    • /
    • 제39권3호
    • /
    • pp.127-133
    • /
    • 2014
  • 북한 우라늄 농축 시설은 국내외적으로 심각한 위협중 하나이다. 특히 우리나라 입장에서는 국가 안보에 관련된 사안이므로 항상 주시하고 대비를 하여야 한다. 북한 미신고 우라늄 농축시설 탐지 가능성을 평가하기 위해 시설로 부터 장 단거리에 따른 공기중 우라늄 농도를 예측하였다. 북한 농축시설에 대해 국제 사회에 알려진 정보와 다른 국가의 농축 시설 운영 데이터를 근거로 북한 시설로부터 공기중으로 누출되는 $UF_6$ 선원항(source terms)을 계산하였다. 계산된 선원항과 영변 주변 기상 자료를 바탕으로 장 단거리 대기 확산 모델 - Gaussian Plume and HYSPLIT Models -을 이용하여 북한 농축시설 주변과 멀리 떨어진 남한 지역에서의 공기중 우라늄 농도를 결정하였다. 최대 공기중 우라늄 농도와 위치는 기상 조건과 방출 높이에 따라 시설 바로 근처와 0.4 km 이내 이고, 농도 약 $1.0{\times}10^{-7}g{\cdot}m^{-3}$로 나타났다. 본 논문의 가정을 적용하였을 때, 수 십 ${\mu}g$ 정도의 우라늄 샘플을 채취할 수 있을 것으로 나타났다. 이 수십 ${\mu}g$ 우라늄 양은 현대 측정 장비로 어려움 없이 측정 가능한 양이다. 반면에 영변 농축시설에부터 수 백 km이상 떨어진 남한 지역의 농도는 $1.0{\times}10^{-13}{\sim}1.0{\times}10^{-15}g{\cdot}m^{-3}$이하로 자연 방사성 우라늄 농도보다 낮은 값이다. 따라서 본 논문에 의하면 북한 영변 농축시설 주변에서 공기포집에 의한 신고 및 미신고 핵활동 탐지는 가능하지만 장거리에서는 불가능할 것으로 예측된다.

패트리어트 (patriot) 미사일의 최적 배치 (Optimal deployment strategy of patriot missile)

  • 김영휘;김성인;오원민
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1994년도 춘계공동학술대회논문집; 창원대학교; 08월 09일 Apr. 1994
    • /
    • pp.29-37
    • /
    • 1994
  • It is reported that north Korea has already developed 1,500 to 2,000-km-range Scud missile. As a defensive strategy against Scud attack on military and civilian facilities the military authorities are considering deployment of Patriot missile. This paper deals with its optimal deployment strategy. In this problem a Patriot missile which has multiple-facility responsibility may be able to protect each of its assigned facilities only with a certain probability, not absolute protection, and it may not be adequate to have only a single missile protect a facility, either because of its operational reliability or because of its limited availability at any given point in time. We formulate this problem into the probabilistic partial set covering model developed by Sherali and Kim. The applicability, verification and validation of the model are tested via an abbreviated case study.

염산취급시설의 사고시 사업장외에 미치는 영향평가 (Offsite Risk Assessment on Chloric Acid Release)

  • 박교식
    • Korean Chemical Engineering Research
    • /
    • 제54권6호
    • /
    • pp.781-785
    • /
    • 2016
  • 위험물인 염산을 취급하는 사업장에서 발생할 수 있는 사고를 알아내고 사고시 인근에 미치는 영향을 평가하여 어느 정도 위험이 있는지 알아보며 이에 대한 대비책을 적용하고자 하였다. 취급 화학물질 정보와 공정정보로부터 사고 시나리오를 선정하고 염산 누출시 사업장외로 영향을 미치는 사고 시나리오를 선정하여 환경부의 지침에 따라서 ALOHA를 활용하여서 평가하였다. 최악의 사고 시나리오를 비롯한 사고 시나리오를 평가하였으며 이들의 사고시 피해완화대책도 살펴보았다. 평가결과 염산생산시설은 현재의 안전조치가 충분하여서 추가의 개선대책이 필요하지 않은 것으로 판명되었다.

독일 산업·기술문화재 한자 코크스 제조소 재생사례 분석 (Analysis on the Characteristics of the Precedents for Industrial/Technological Cultural Properties of the Hansa Coking Plant)

  • 김홍기;박창호
    • 한국가구학회지
    • /
    • 제27권1호
    • /
    • pp.59-68
    • /
    • 2016
  • The Industrial/Technological Cultural Properties are being protected, the rest facing with demolition and damages. In order to better cope with such situation, Korea has officially introduced the Registered Cultural Properties System since 2001 and began acknowledging the historical values of industrial buildings as modern cultural properties. In the Nordrhein-Westfalen, Germany, there are approximately 3,500 industrial buildings under the cultural asset protection and management not only in the Ruhr-region but also state-wide. Among these, this case study focuses on the Hansa Coking Plant, a large-scale Revitalization project to rehabilitate the old industrial complexes and facility buildings that have been shut down on December 15, 1992. Purpose of this study is to analyze main project plans of each facility in the Hansa Coking Plant and to bring out the main features of the plans, so that they can be utilized to find suggestions for Industrial/Technological Cultural Properties Revitalization in Korea.

폐기물 소각시설 내부 소음에 관한 연구 (A Study on Noise in Waste Facilities)

  • 서병석;박노국;전용한
    • 대한안전경영과학회지
    • /
    • 제22권2호
    • /
    • pp.15-21
    • /
    • 2020
  • Industrial facilities need design to predict and reduce noise from design to prevent and reduce noise. The purpose of this study is to predict worker's environment and evaluate safety by analyzing noise inside underground blower room and air compressor room with fluid machinery in waste facility. This waste incineration facility was analyzed based on the ground floor, ground floor blower chamber, and air compressor chamber. The results of SPL(Sound Pressure Level) analysis at 1.5m away, which are frequently used to measure the SPL as a noise source, are as follows. SPL of basement level: 46.80[dB], SPL of ground layer: 48.57[dB]. As a result, it was expected that the noise level would be considerably lower than the 8 hours 50[dB] noise exposure per day.

해양플랜트의 방화대책 및 설계기술 소개 (Introduction of Fire Protection Technology and Its Design Method of Offshore Facilities)

  • 구명준;최재웅;윤호병
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제1권1호
    • /
    • pp.49-57
    • /
    • 2013
  • 해양플랜트의 설계는 위험요인을 정량적 위험성평가를 통해 계량화하여 그 결과를 설계에 반영하는 것이 일반화되어 있다. 대표적인 위험요소인 화재 위험에 대해서도 이는 마찬가지다. 계량화된 화재 위험에 대해 작업자들이 탈출하는 동안 안전설비의 기능을 유지하고 발생된 화재가 더 크게 전이(escalation)되는 것을 방지하는 것이 방화대책의 궁극적인 목적이다. 본 논문에서는 대표적인 방화대책인 능동방화대책과 수동방화대책의 적용사례를 살펴보고 수동방화대책의 설계기법들을 소개한다. 수동방화대책은 효과적인 방화기법이지만 초기 투자비가 많이 소요되고 운용과 유지보수에 애로사항이 크다. 따라서, 최근 들어 발주자들은 수동방화대책을 최적화하도록 해양플랜트 설계자에게 요청하는 추세이다.

수장고에 설치된 소방시설의 실태 및 개선방안에 관한 연구 (Study of the Real Condition and Improvement Plans of a Fire Protection System Installed at Museum Storage)

  • 박종아;주승호;강은수;이대건
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.60-66
    • /
    • 2018
  • 근래 박물관에 대한 변화 중 주목할 부분으로 학예사 및 관리자 등 전문가의 고유영역이었던 수장고가 점차 관람객에게 공개되는 형태로 바뀌고 있어 관람객의 부주의 등에 따른 화재 위험도는 증가할 것이며, 그에 따른 소방시설 또한 변화하는 수장고에 적응할 수 있는 알맞은 대책 마련이 필요하다고 사료된다. 이에 본 논문에서는 문화체육관광부의 지원을 받아 국내 40개소 공립박물관의 답사를 통해 수장고에 적용된 소방시설의 현황을 분석하였으며, 수장고에 적응성이 떨어지는 소방시설 혹은 관리가 미흡하거나 우수한 소방시설의 사례들을 도출하여 그에 따른 소방시설의 설치방향을 제시하였고, 수장고에 개선하여 적용할 수 있도록 방향을 제시하였다.

소방전원계통의 전원용량과 간선의 전압강하에 대한 문제점 분석 (Problem Analysis of Power Capacity and Main Line Voltage Drop of Electric Power System for Fire Protection)

  • 최승규;손봉세
    • 한국화재소방학회논문지
    • /
    • 제29권3호
    • /
    • pp.53-58
    • /
    • 2015
  • 최근 소방대상물의 대형화는 소방전기계통의 용량과 간선길이를 급격하게 증가시키고 있어, 과거의 소규모 소방대상물에서는 문제가 되지 않았던, 소방전원의 용량부족과 간선의 전압강하 증가로 규정전압을 벗어나는 문제점를 발생시키고 있다. 이러한 문제점은 소방용 전원전압이 규정전압에 미달되어 각종 전기설비가 동작하지 못하는 심각한 결과를 초례할 수 있다. 이에 본 논문에서는 실제 준공된 소방대상물을 대상으로 전원공급장치의 용량 및 소방전기간선의 전압강하를 이론적으로 계산하여 문제점을 도출하고 분석하여, 소방전원계통에서 소방용 전원의 안정적이고 합리적인 설계와 운용에 대한 대책이 요구됨을 확인하였다.