Development of Fully Integrated Broadband MMIC Chip Set Employing CSP(Chip Size Package) for K/Ka Band Applications (CSP(Chip Size Package)를 이용한 완전집적화 K/Ka 밴드 광대역 MMIC Chip Set 개발)

  • Yun Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.102-112
    • /
    • 2005
  • In this work, we developed fully integrated broadband MMIC chip set employing CSP(Chip Size Package) for K/Ka band applications. By utilizing an ACF for the RF-CSP, the fabrication process for the packaged amplifier MMIC could be simplified and made cost effective. $STO(SrTi_{3})$ capacitors were employed to integrate the DC biasing components on the MMIC, and LC parallel circuits were employed for DC feed and ESD protection. A pre-matching technique and RC parallel circuit were used to achieve a broadband matching and good stability fer the amplifier MMIC in K/Ka band. The amplifier CSP MMIC exhibited good RF performance over a wide frequency range in K/Ka band. This work is the first report of a fully integrated CSP amplifier MMIC successfully operating in the K/Ka band.

Arc Fault Circuit Interrupter Design using Microprocessor (마이크로프로세서를 이용한 아크결함 차단기 설계)

  • Yoon, Kwang-Ho;Ban, Gi-Jong;Lee, Hyo-Jik;Park, Byung-Suk;Nam, Moon-Hyon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.12-18
    • /
    • 2007
  • As an arc fault interrupter, the AFCI mentioned in this paper has been designed to detect and interrupt arc faults due to wire deterioration, insulation, wire damage, loose connection, and excessive mechanical damage. Since AFCI is digital and uses mechanical and electric stress, the length of interruption against overload and over-current is much shorter than the current bi-metal method. Therefore, the risk of electrical fires has been reduced.

Application of Fault Current Limiter in 22.9kV KEPCO power distribution line (22.9kV 지중선로용 한류기 한전 실계통 시범적용)

  • Kim, Min Jee;Park, Kyungwon;Ahn, Kil-Young;Kim, Young-keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1034-1035
    • /
    • 2015
  • Watertight 25.8 kV/600 A/12.5 kA fault current limiters (FCLs) have successfully installed in five areas (Incheon, Seoul, Gyeong-gi, Daejeon, Suwon) on KEPCO power distribution line for the purpose of commercial demonstrations. The fault current limiting operation of this FCL, which includes functions of sensing, commutation, and reduction of fault currents, is perfectly completed within 1 cycle immediately after fault occurs. The performance of FCL was verified by short circuit test, impedance test, insulation test, temperature-rise test, and control test, etc at PT&T in LS industrial systems, which is the official certification institute in Korea. In 2013, and also the FCL field test was performed in order to test the protection coordination between conventional relays and FCL, on the 1.5 kA and 5.0 kA faults, which were made by connecting the Artificial Fault Generator (AFG) to the distribution line in test grid at KEPCO Power Testing Center. The next step of this project is to check the FCL conditions caused by real external environment, and acquire the various data from five regions installed with FCL. In this paper, we intend to explain the FCL specifications and performance characteristics, and check the expected effect by application of FCL to power distribution line based on the power system analysis of an application site.

  • PDF

Sustainable Development of Palm Oil: Synthesis and Electrochemical Performance of Corrosion Inhibitors

  • Porcayo-Calderon, J.;Rivera-Munoz, E.M.;Peza-Ledesma, C.;Casales-Diaz, M.;de la Escalera, L.M. Martinez;Canto, J.;Martinez-Gomez, L.
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.133-145
    • /
    • 2017
  • Palm oil production is among the highest worldwide, and it has been mainly used in the food industry and other commodities. Currently, a lot of palm oil production has been destined for the synthesis of biodiesel; however, its use in applications other than the food industry has been questioned. Thereby for a sustainable development, in this paper the use of palm oil of low quality for corrosion inhibitors synthesis is proposed. The performance of the synthesized inhibitors was evaluated by using electrochemical techniques such as open circuit potential measurements, linear polarization resistance and electrochemical impedance spectroscopy. The results indicate that the fatty amides from palm oil are excellent corrosion inhibitors with protection efficiencies greater than 98%. Fatty amides molecules act as cathodic inhibitors decreasing the anodic dissolution of iron. When fatty amides are added, a rapid decrease in the corrosion rate occurs due to the rapid formation of a molecular film onto carbon steel surface. During the adsorption process of the inhibitor a self-organization of the hydrocarbon chains takes place forming a tightly packed hydrophobic film. These results demonstrate that the use of palm oil for the production of green inhibitors promises to be an excellent alternative for a sustainable use of the palm oil production.

A Study on Explosion and Fire Risk of Lithium-Ion and Lithium-Polymer Battery (리튬이온 및 리튬폴리머 배터리의 폭발과 화재 위험성에 관한 연구)

  • Lee, Bum Joo;Choi, Gyeong Joo;Lee, Sang Ho;Jeong, Yeon Man;Park, Young;Cho, Dong Uk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.855-863
    • /
    • 2017
  • Because Li-ion battery and Li-Polymer battery have high-energy storage density, they are used for various electronic devices such as electronic cigarette, electronic bicycle, drone, second battery, even golf cart and electronic car. Recently, however, battery explosion is sometimes occurring on electronic devices using Li-ion battery and is becoming serious as bodily harm is breaking out due to explosion. For this, this paper described the Li-ion Battery's operating principles and verified the cause of explosion by overload tests caused by the high-energy storage density. According to the these experiments, we conducted a study to develope scanning techniques of fire and safety measures.

Pro-environmental Maintenance and Management of Tour Cave : The Currents, Problems and Alternatives in Korea (관광동굴의 환경친화적 관리 방안에 관한 연구)

  • 유영준;이경호
    • Journal of the Speleological Society of Korea
    • /
    • v.59
    • /
    • pp.21-36
    • /
    • 1999
  • Most scholars calssify caves into natural resource, but caves possess values of natural and human resource, mix up the features of natural resources and human resources. Now, caves are distributed 260 in Korea. Seongryu Cave is showed in 1967 for the first time, till 1997 12 caves is opened to tourist. But since 1996 the 12 show caves of all is not launched the safety and environment-protection check-up adduced reason for IMF. Then caves must maintain environment of the normal temperature, humidity and dark. But the environment of caves are destroyed by tourism development. Thus to maintain environment of caves, it used to consider the counterplan as follows in restraint of the environmental change. Firstly, in case of development work to open caves, it must keep up with the prototype. Secondly, it must establish a freight depositary to prevent the influence of the caves's stain and damage due to tourist's objects. Thirdly, to maintain the normal temperature and humidity, it must install artificial poultice equipment of the inner parts of caves. Fourthly, in order to prevent the occurrence of $CO_2$, it must assessment of the optimum number of the greatest stayer. Fifthly, the control of closure for a given period of time is useful of the restoration to the cave's original state. Sixthly, by means of make narrow entrance, it should not influence the outer's air on the inner parts on caves. Seventhly, to keep the temperature of the inner part of caves, the lightening should be maintained moderately considering the convenience of a tour. Eightly, when water-proof cables for the lightening bulbs are connected each other, silicon tape is suitable and circuit breakers should be installed at the diverging points of the cables. Ninthly, the direction and angle of the lightening must be changed periodically to prevent green-pollution at the lightening spot. Lastly, when facilities and arrangements are equipped, corrosive materials should be excluded if circumstances allow.

  • PDF

Application of Police Video Equipment for Fighting Crime and Legal Trends (범죄 대응을 위한 경찰 영상장비의 활용과 법 동향)

  • Lee, Hoon;Lee, Won-Sang
    • Informatization Policy
    • /
    • v.25 no.2
    • /
    • pp.3-19
    • /
    • 2018
  • With the introduction of video cameras into law enforcement, a great deal of police organizations have adopted the technology in their routine crime prevention activities. The up-to-date systems of ambient surveillance energized by CCTV, police wearable cameras, drones, and thermal imaging devices enable the police to thoroughly monitor public spaces as well as to rigorously arrest on-scene criminals. These efforts to improve the level of surveillance are often met with public resistance raising concerns over citizens' rights to privacy. Recent studies on the use of police video equipment have constantly raised the issues related to the lack of applicable legal provisions, risk of personal information and privacy infringement as well as security vulnerabilities. In this regard, the present study attempted to review the public surveillance methods currently used by law enforcement agencies worldwide within the context of public safety and individual rights to privacy. Furthermore, the present study also discussed the legal boundaries of police use of video equipment to address public concerns over privacy issues.

Pulse 2 kW RF Limiter at S-band (S-대역 펄스 2 kW RF 리미터)

  • Jeong, Myung-Deuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.7
    • /
    • pp.791-796
    • /
    • 2012
  • A RF limiter is a component to protect the receiver front end from undesired signal. A RF limiter is a key component whose output is constant level for all inputs above a critical value. A RF limiter use a diode to pass signals of low power while attenuating those above some threshold. A RF limiter for receiver protection in modern radar systems is playing a vital role in order to meet challenges of new interference threats and complicated electromagnetic environments. This paper proposed a new circuit for high power RF limiter whose structure is the combination of the PIN diode and Limit diode. PIN diode take a use of its isolation characteristics which act as a switch does. A 2 kW RF limiter with 200 us pulse width at S-band was developed. It shows good agreements between estimated value and measured results.

Discharging Voltage Control with Error Detecting for Search light of Ship (선박용 탐사조명 전원장치의 방전개시전압 제어와 조명 이상검출)

  • Park, Noh-Sik;Kwon, Soon-Jae;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.8-17
    • /
    • 2008
  • This paper presents a stable lighting method for HID lamp for ship from initial discharging current limit with discharging voltage control. The output voltage of the proposed control scheme is boosted for ignition, and the charging voltage is decreased by the resistor discharging. The proposed controller fires the initial discharge at the designed discharging voltage to limit the discharge current. After the discharging, constant current controller is used for brightness in steady state. The proposed control scheme can limit the initial discharge current using the starting point control without a complex voltage controller. so it can improve the life-time of HID lamp and get a stable discharge from restricted the initial discharge current. In order to improve the protection of the system, a simple instantaneous error detecting circuit for open state and short state of HID lamp is used. The proposed error detecting of HID lamp can protect the power system of lamp control. The effectiveness of the proposed controller is verified from the experiments of practical 2.5[kW] HID search light for ship.

High Power Density Open-frame Type DC-DC Converter Module with Constant Current Control (정전류 제어 기능이 부가된 고전력밀도의 개방형 DC-DC 컨버터 모듈)

  • Lee Darl-Woo;Ahn Tae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.380-387
    • /
    • 2005
  • We report the performance of an open-frame type low-voltage high-current DC-DC converter module developed using an active clamp forward converter circuit and single ended rectifier. The converter module is designed with the specifications of an 3.3V output voltage, 30A output current, 100W output power and 36-75V input voltage. The synchronous rectifier is used to reduce the conduction loss at high current level and constant current control using precision PCB resistance is adapted to enhance the over current protection function in the system configuration. A prototype converter module is successfully implemented within 8mm height and quarter brick size (58x37mm) and recorded an $95W/in^3$ power density, 90.6$\%$ efficiency and 0.07$\%$ voltage regulation for the entire Input voltage range, thereby demonstrating its application potentials to future telecommunication electronics.