• Title/Summary/Keyword: Protection circuit

Search Result 634, Processing Time 0.024 seconds

Development of PC-based Auto Inspection System for Smart Battery Protection Circuit Module (PC기반의 스마트 배터리 보호모듈 자동 검사 시스템 개발)

  • Yoon, Tae-Sung;Jang, Gi-Won;Park, Ju-No;Lee, Jeong-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.275-277
    • /
    • 2005
  • In a lithium-ion battery which is being used in many portable electronic goods, electrolyte is disaggregated and then the gas is happened when electric charging volt is over the 4.5V. So, the pressure on the safety valve is increased and electrolyte is leaked out in the cell. It leads to the risk of explosion. On the other hand, in the case which the battery is discharged excessively, the negative pole is damaged and the performance of the battery is deteriorated. The protection module of a lithium-ion battery is used for preventing such risk and the inspection system is needed to check the performance of such protection module. In this research, a PC-based auto inspection system is developed for the inspection of a battery protection module using Dallas chipset. In the inspection system, AVRl28 chip is used as a controller and the communication protocol is developed for the data communication between the protection module and the AVR128 chip. And GPIB interface is used for the control of measuring devices. Also, MMI environment is developed using LabView for convenient monitoring by the tester.

  • PDF

A Study on a New ESD Protection Circuit with Parasitic PNP BJT Insertion Type with High Robustness Characteristics Based on SCR (SCR 기반 고감내 특성을 갖는 기생 PNP BJT 삽입형 새로운 ESD 보호회로에 관한 연구)

  • Chae, Hee-Guk;Do, Kyoung-Il;Seo, Jeong-Yun;Seo, Jeong-Ju;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.22 no.1
    • /
    • pp.80-86
    • /
    • 2018
  • In this paper, we propose a new PNP bipolar insertion type ESD protection circuit with improved electrical characteristics than the existing ESD protection circuits SCR and LVTSCR. The proposed circuit has 8.59V trigger voltage which is about 9V lower than that of the conventional SCR, and the parasitic PNP has one more operation and high robustness characteristics. For the practical design of the proposed ESD protection circuit, the holding voltage was increased by increasing the base length of the parasitic PNP while increasing the variable L. To verify the electrical characteristics of the proposed device, Synopsys T-CAD simulator was used.

Design of a Low Drop-out Regulator with a UVLO Protection Function (UVLO 보호기능이 추가된 LDO 레귤레이터 설계)

  • Park, Won Kyeong;Lee, Su Jin;Park, Yong Su;Song, Han Jung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.239-244
    • /
    • 2013
  • This paper presents a design of the CMOS LDO regulator with a UVLO protection function for a high speed PMIC. Proposed LDO regulator circuit consists of a BGR reference circuit, an error amplifier and a power transistor and so on. UVLO block between the power transistor and the power supply is added for a low input protection function. Also, UVLO block showed normal operation with turn-off voltage of 2.7V and turn-on voltage of 4 V in condition of 5 V power supply. Proposed circuit generated fixed 3.3 V from a supply of 5V. From SPICE simulation results using a $1{\mu}m$ high voltage CMOS technology, simulation results were 5.88 mV/V line regulation and 27.5 uV/mA load regulation with load current 0 mA to 200 mA.

A Study on ESD Protection Circuit with Bidirectional Structure with Latch-up Immunity due to High Holding Voltage (높은 홀딩 전압으로 인한 래치업 면역을 갖는 양방향 구조의 ESD 보호회로에 관한 연구)

  • Jung, Jang-Han;Do, Kyung-Il;Jin, Seung-Hoo;Go, Kyung-Jin;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.376-380
    • /
    • 2021
  • In this paper, we propose a novel ESD protection device with Latch-up immunity properties due to high holding voltages by improving the structure of a typical SCR. To verify the characteristics of the proposed ESD circuit, simulations were conducted using Synopsys TCAD and presented compared to existing ESD protection circuits. Furthermore, the variation of electrical properties was verified using the design variable D1. Simulation results confirm that the proposed ESD protective circuit has higher holding voltage properties and bidirectional discharge properties compared to conventional ESD protective circuits. We validate the electrical properties with post-design TLP measurements using Samsung's 0.13um BCD process. And we verify that the proposed ESD protection circuit in this paper is well suited for high voltage applications in that it has a latch-up immunity due to improved holding voltage through optimization of design variables.

Design of CT used Protection Relay by Electromagnetic Field Analysis (전자장 해석을 통한 보호 개전기용 CT 설계)

  • Sohn, Jong-Mahn;Song, Hee-Chan;Choe, Jong-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.155-158
    • /
    • 1997
  • In design of current transformer, equivalent circuit parameters is obtained by electromagnetic analysis and used circuit simulation. Precise core secton area and turns of coil can be determined by circuit analysis. Therefore exact design of current transformer is possible by field and circuit analysis.

  • PDF

Crowbar Circuit for the Overvoltage Protection Using GTO (GTO를 이용한 과전압 억제용 크로바 회로)

  • Ryu, Ho-Seon;Lim, Ick-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.343-345
    • /
    • 1996
  • In the case of synchronous machines, certain power system disturbances cause current to assume negative values when no static converter is present. But the converter prevents negative current from flowing, so that overvoltages occur. The overvoltages can be effectively limited as crowbar circuit using GTO. The crowbar circuit with current limiting resistor absorbs energy when overvoltage comes from power system repeatedly. The newly proposed circuit is verified through simulation and experiment

  • PDF

Study on the LED BLU Driving Circuit with a Local-dimming Structure (다분할 디밍구조를 갖는 LED BLU 구동회로에 관한 연구)

  • Park, Yu-Cheol;Kim, Hee-Jun;Chae, Gyun;Baek, Ju-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.292-300
    • /
    • 2009
  • This paper presents an LED BLU driving circuit with a local-dimming structure. The efficiency of the proposed LED driver has been improved by parallel driving 8 serial-connected LED arrays. It employed the soft-switching boost converter topology to reduce the switching power loss of the hard switching boost converter. Soft- and hard-switching converters have the same structure except that the free-wheeling diode in the hard-switching converter is replaced with the n-channel MOSFET in the soft-switching one. The proposed boost converter was compared with the hard switching converter. The soft-switching converter reveals superior ripple and efficiency. A smaller inductance can be used for the soft-switching converter contrasting to the hard-switching one. We also studied on an over-voltage protection circuit of the output of the driver at the no load condition. The protection circuit was applied to the proposed driver, and its operation was confirmed by experiment. Using a local-dimming technique, power consumption of LCD BLUs can be reduced as low as possible according to the brightness of its image.

Analysis of An Improved Short-circuit Protection for Multilevel PWM ac/dc Converter (멀티레벨 PWM ac/dc 컨버터의 향상된 단락보호기법 해석)

  • Kang S. K.;Nho E. C.;Kim I. D.;Joe C. J.;Chun T. W.;Kim H. G.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.193-196
    • /
    • 2001
  • This paper describes an improved short-circuit protection for a multilevel ac/dc power converter The output do power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. Once the fault has been cleared the dc power is reapplied to the load. The rising time of the do load voltage is as small as several hundred microseconds, and there is no overshoot of the dc voltage because the do output capacitors hold undischarged state. Therefore, the proposed converter can be used for a power supply, which requires a rapid disconnection of the load from the power supply in the case of a short circuit, as well as a rapid connection the load to the power supply after the clearance of the short circuit condition.

  • PDF

Study on the Explosion and Fire Risks of Lithium Batteries Due to High Temperature and Short Circuit Current (고온 및 단락전류에 따른 리튬배터리의 폭발 및 화재 위험성에 관한 연구)

  • Sim, Sang-Bo;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.114-122
    • /
    • 2016
  • This study is to analyze the explosion and fire risks due to high temperature and short circuit current of Lithium batteries. This study selected the typical types of Li-polymer batteries and Li-ion batteries as the test samples. The result of explosion risk assessment due to the high temperature showed that, while a Li-polymer battery had $170^{\circ}C$ explosion on average, a Li-ion battery had $187^{\circ}C$ explosion. The measurement result of temperature increase due to short circuit current revealed that, in case that protection circuit module (PCM) was normally working, there was little of temperature increase due to over-current limitation. However, in case that PCM was out of order, the temperature of a Li-polymer battery increased up to an average of $115.7^{\circ}C$ and the temperature of a Li-ion battery increased up to an average of $80.5^{\circ}C$, which showed the higher risks of fire and burn.