• 제목/요약/키워드: Protection against lightning surges

검색결과 16건 처리시간 0.023초

A Study on Lightning Surges in Underground Distribution Systems

  • Jung Chae-Kyun;Kim Sang-Kuk;Lee Jong-Beom
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.171-176
    • /
    • 2005
  • The effects of surge arresters for the protection of transmission systems against direct lightning strokes have already been reviewed by many researchers. However, their studies have not encompassed underground cable systems. Therefore, in this paper we investigate the 22.9kV combined distribution systems that have arresters and ground wires. In addition, we analyze the overvoltages on underground distribution cable sections when direct lightning strokes contact the overhead ground wire using EMTP. Finally, we discuss the effect of lightning strokes according to the change of cable length and installation of arresters. This study provides insulation coordination methods for reasonable system design in 22.9kV underground distribution cable systems.

뇌임펄스전압에 대한 30[A]용 고감도형 누전 차단기의 오동작에 대한 특성의 해석 (Analysis of Malfunction Characteristics of High Sensitivity Type Earth Leakage Circuit Breaker for 30[A] due to Lightning Impulse Voltages)

  • 이복희;이승칠;김찬오
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권6호
    • /
    • pp.96-103
    • /
    • 1997
  • 본 논문은 뇌임펄스전압에 대한 누전 차단기의 오동작 특성에 관한 것으로 한국공업규격 KS C 4613의 규정과 서지보호장치를 갖는 모의회로의 조건에서 누전차단기의 부동작 특성을 실험적으로 조사하고 검토하였다. 실험 결과, 본 연구에 사용한 30[A]용 고감도형 누전 차단기인 모든 시료는 증폭회로의 전원부에 설치된 서지보호장치에 의해 입사되는 차동모드의 뇌임펄스전압에 차단되는 성능을 가지고 있었다. 4종의 시료는 KS C 4613에 정의된 뇌임펄스 부동작시험조건을 만족시키지 못하였으며, 그때의 오동작을 유발한 전압은 약 5∼6.5[kV]로 비교적 높았다. 서지보호장치가 설치된 경우를 모의한 시험조건에서는 3종의 누전차단기가 오동작하였으며, 누전차단기가 오동작을 일으키는 전압도 약 3∼5[kV] 정도로 비교적 낮았다.

  • PDF

발전소내 스위치야드 및 주변압기간 연결선로의 적정 피뢰기 위치 선정 (A STUDY ON EFFECTIVE APPLICATION OF SURGE ARRESTER BETWEEN THE SWITCHYARD AND MAIN TRANSFORMER IN POWER PLANT)

  • 이흥찬;함영수;정기수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.503-505
    • /
    • 1995
  • The surge arrester plays a vital role in the protection of substation against transient overvoltages resulting from lightning surges and system switching operations. The proper selection and application of the surge arrester is an integral part of the process of substation equipment insulation level selection. The paper outlines the basic consideration in modeling the lightning stroke, the surge arrester, and the system to be protected. The paper discusses the results of various cases simulated using the alternative transient computer program to evaluate the separation effects.

  • PDF

수분함유량에 따른 토양의 저항률 및 비유전율의 주파수의존성 (Frequency-Dependent Resistivity and Relative Dielectric Constant of Soil on Water Content)

  • 최종혁;차응석;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.98-104
    • /
    • 2010
  • 고주파수성분을 포함하는 뇌격전류나 또는 고장전류에 대한 접지시스템의 성능을 평가하기 위해 접지저항보다는 접지임피던스에 대한 고려가 필요하다. 접지임피던스를 평가하기 위해서는 토양의 저항률과 비유전율의 주파수의존성이 규명되어야 한다. 본 논문은 3가지 다른 토양에 대하여 수분함유량에 따른 저항률과 비유전율의 주파수의존성을 나타낸다. 결론적으로 토양의 저항률은 수분함유량이 증가함에 따라서 작아지게 되고, 1[MHz]보다 낮은 주파수에서 거의 변화하지 않으며 1[MHz]이상의 주파수에서는 감소한다. 반면에 비유전율은 1[MHz]이하의 주파수에서 매우 급격하게 감소하며, 1[MHz]이상의 주파수에서는 거의 변화하지 않는 것으로 나타났다. 본 실험 결과로 부터 낙뢰 또는 개폐서지에 대한 보호를 목적으로하는 접지시스템의 설계시 토양의 저항률과 비유전율을 고려하는 것이 바람직한 것으로 밝혀졌다.

모래의 수분함유량에 따른 비저항 및 비유전율의 주파수 의존성 (Frequency Dependent Resistivity and Relative Dielectric Constant with the Water Contents in Sand)

  • 이복희;차응석;최종혁;최영철;유양우;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.348-351
    • /
    • 2009
  • In order to evaluate the performance of a grounding system against lightning or fault currents including high frequency components, the grounding impedance should be considered rather than its ground resistance. Recently, some researches on the evaluation and modeling of the grounding impedances have been carried out but the results have not been yet sufficient. This paper deals with the frequency dependence of the resistivity and relative dielectric constant of sand associated with water contents. As a result, the resistivity of sand is getting lower with increasing water content and it is nearly independent on the frequency in the range of less than 1MHz, and is decreased over the frequency range of above 1MHz. Also, the relative dielectric constant is rapidly decreased with the frequency in the range of less than 10kHz, but it is nearly not dependent on the frequency over the frequency range of 10kHz. It was found from this work that the frequency dependance of resistivity and relative dielectric constant of soil should be considered in designing the grounding systems for protection against lightning or surges.

  • PDF

원전낙뢰보호 및 접지계통에 대한 규제기술연구 (A Study on the Regulatory Technology for Lightning Protection and Grounding System in Nuclear Power Plants)

  • 이재도;주운표;이상근;김대식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.66-68
    • /
    • 2007
  • The regulatory guide, RG-1.204 and its underlying or confirmatory research, NUREG/CR-6866 were studied for Korean application to LPGS of NPPs. However they excluded the application to that of NPPs. So US-NRC approved selectively industrial standards to that of NPPs on Nov 2005. It is necessary to understand the basis of regulatory technology related regulatory positions on LPGS and important to implement the guidance on LPGS as a resonable standard. The paper is examined what and how state of the art of relevant technology applied to the LPGS as well as the trip-out events related to electrical system were involved with LPGS. We reviewed the relevant standards applicable to Korean NPPs. Following are concluded to recommend. (1) IEEE 510-1050 is recommended as a guide for I&C grounding against EMI and lighting transients (2) IEEE Std-665, 510-666, Std-C62.23 for electrical grounding against voltage surges and lighting transients (3) Inspection should be thoroughly be implemented a frequency of 3-5 year period according to NFPA780 or KSC-IEC 61024.

  • PDF