• 제목/요약/키워드: Protection System

검색결과 5,901건 처리시간 0.037초

HVDC시스템의 직류측 보호 모델 개발 (The Assessment and Development of Protection Models in HVDC DC side)

  • 이성두;김찬기
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1754-1760
    • /
    • 2010
  • The HVDC system consists of ac side and dc side through thyristor valve. ac side protection is similar to conventional ac system protection schemes but dc side protection is different from ac side of HVDC system. AC system don't have controller but HVDC system has controller that controls and protects system from faults and disturbance. This paper show protectional function of HVDC dc side such as asymmetry protection, ac/dc differential protection, dc overvoltage, dc overcurrent protection. Protection models is developed using RTDS software and assessment of protection models is also performed by RTDS system.

Space shuttle의 Thermal Protection System의 설계 목표 (Design Golas for the Space Shuttle's Thermal Protection System)

  • 김선규
    • Journal of Astronomy and Space Sciences
    • /
    • 제1권1호
    • /
    • pp.35-39
    • /
    • 1984
  • Space Shuttle의 성공적인 비행을 가능케한 요인중의 하나가 Silica Tile을 사용한 재사용 할 수 있는 Thermal Protection System의 설계이었다. 이러한 Thermal Protection System의 기본 설계 개념을 밝히고 또한 Silica Tile의 생산 공정과 Tile System의 구조를 서술하였다.

  • PDF

이산 마코프 모델을 이용한 보호 시스템의 고장 비율 추정 (Estimating the Failure Rate of Protection System Using a Discrete Markov Model)

  • 신정진;이희태;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.385-387
    • /
    • 2008
  • When a fault occurs in the distribution system, it is detected by protection system, then protection system is opened and de-energises the feeder where the fault exists. in this paper, the failure rate of protection system will estimate that using a discrete markov approach with failure data of protection system in order to improve the reliability of protection system.

  • PDF

분산전원이 연계된 배전계통의 고장특성을 고려한 방향성 보호계전 방식 적용 연구 (Application of Directional Over Current Protection Schemes Considering the Fault Characteristics in the Distribution System with Dispersed Generation)

  • 정원욱;이학주;권성철;채우규
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.97-107
    • /
    • 2010
  • Penetration of distributed generator(DG) to power distribution system can cause malfunction of existing protection schemes. Because grid interconnected DG can contribute fault currents and make bidirectional current flows on the system, fault contributions from DG can cause an interference of protection relay operation. Therefore, over current protection device of the distribution system with DGs need directional protection schemes. In this paper, improved directional protection algorithms are proposed for the distribution system with DG considering their fault characteristics. And than, these directional protection algorithms are tested and validated in various fault conditions. From the simulation results, it can be seen that the proposed directional protection algorithms are practically efficient for the radial distribution system with DG.

화재 수신기용 과도현상 보호시스템 개발에 관한 연구 (A Study on the Transient Phenomenon Protection System Development for Fire Alarm System Control Unit)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제23권2호
    • /
    • pp.55-61
    • /
    • 2009
  • 본 연구에서는 서지나 순간 과전압 등에 의한 과도현상으로부터 보호될 수 있는 높은 신뢰성의 화재수신기가 될 수 있도록 과도현상 보호시스템의 개발에 대한 연구를 수행하였고, 보호시스템의 성능을 시험으로 입증함으로써 과도현상 보호시스템을 개발할 수 있는 기틀을 마련하였다. 과도현상 보호시스템의 개발을 위한 프로세스 정립과 이론을 바탕으로 과도현상으로부터 보호될 수 있는 1단계 및 2단계 보호시스템을 개발하였고, 소방법 및 관련규정에서 제시하는 제반 성능조건으로 시험하고 만족스런 결과를 얻음으로써, 과도현상 보호시스템을 개발할 수 있는 엔지니어링 데이터 구축과 원천기술을 확립하였다.

공간정보를 활용한 소방시설의 관리방안 연구 (A Study on the Management Plan of Fire Protection System Utilizing Urban Spatial Information)

  • 방창훈
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.98-104
    • /
    • 2019
  • 본 연구는 공간정보를 활용하여 소방시설의 효율적인 관리 방안을 연구하고 관련 소방산업 발전을 위한 기초자료 구축을 목적으로 한다. 소방시설 관리의 오동작과 관리부실 등의 문제점을 극복하는 방안으로 공간정보를 소방시설 분야에 도입하고자 관련 법규와 소방시설의 공간정보 구축방안을 논의하였다. 소방시설의 효율적인 관리를 위하여 공간정보 기술을 포함하는 소방시설 관련 법률의 개정과 소방시설 공간정보의 표준화와 유효성, 일관성을 유지하는 것이 필요하다.

저압계통 연계형 마이크로그리드의 보호감시 시스템 (Supervisory Protection System of Microgird Interconnected to Low Voltage Grids)

  • 정태영;백영식
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.36-42
    • /
    • 2011
  • This paper mainly proposes the protective coordination scheme of the microgrid system. The microgrid protection is identical to the conventional protection system separating the normal part and contingency part to reduce damage when the contingency occur at power cables, facilities. But they are different in the protection type. The conventional protection system only considers unidirectional current. However the microgrid protection should be considered not only unidirectional current but also backfeed current because various microsources and loads are installed in the microgrid system. In case the contingency occurs in microsource, when microgrid is interconnected to grid, the protection system should be configured to not separate microgrid from grid before the microsource is isolated to microgrid. And in case of fault occur in power system, the microsources should not isolated to microgrid before the static switch at PCC is tripped to separate from power system. Considering these characteristic of microgird, this paper proposes the protective coordination scheme of microgrid and implemented the on-line real time monitoring system. Especially in case the microgrid is connected to low voltage distribution system with 220/380V voltage level, the proposed protection method with power IT technology can solve the problems when the existing protective devices only applied to the microgrid system.

Analysis of Stability of PV System using the Eigenvalue according to the Frequency Variation and Requirements of Frequency Protection

  • Seo, Hun-Chul;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권4호
    • /
    • pp.480-485
    • /
    • 2012
  • Use of photovoltaic (PV) power generation system will become more widespread in the future due to anticipated cost reduction in PV technology. As the capacity of PV systems increases, a variation of power system frequency may prevent the stable output of PV system. However, the standard for the frequency protection of distributed generation in Korea Electric Power Corporation (KEPCO)'s rule does not include the setting of frequency protection. Therefore, this paper analyzes the correlation between the frequency protection requirements and the stability of grid-connected PV system for the adjustable operating setting of frequency protection. The distribution system interconnected with 3 MW PV system is modeled by Matlab/Simulink. The various values of frequency are simulated. For studied cases, the stability of PV system is analyzed. It is concluded that the setting of frequency protection is necessary to consider the stability of PV system.

Advanced Real Time Simulation Platform for Control and Protection Studies of LSIS 80kV 60MW Jeju HVDC System

  • Iwa, Kartiwa;Lee, Kyung-Bin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.85-86
    • /
    • 2013
  • This paper describes the physical configuration and features of the advanced control and protection devices, and operation control and monitoring system that are connected to a real time simulator for LS Industrial System 80kV 60 MW Jeju HVDC Pilot Project. Highlight of simulation result are provided to demonstrate the control and protection functionality.

  • PDF

발전기보호반을 위한 IED의 설계에 관한 연구 (A Study on Design of IED for Generator Protection Panel)

  • 박철원;박성완
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.133-138
    • /
    • 2013
  • A large generator is an important role in transferring an electric power to power system. The IEDs of large generator often use microprocessor technology to obtain a digital relay system with a wide range of measuring, protection, control, monitoring, and communication functions. However, all generator protection and control systems in Korea imported from abroad and are being operated. In order to reduce the large expense and improve the reliable operation, development of generator protection and control system by domestic technology is required. This paper deals with the design of the IED of generator protection panel for development of generator protection and control system. The major emphasis of the paper will be on the description of hardware and signal processing test results and measurement accuracy of the prototype IED. By developing of generator IED based on DSP and microprocessor, replacement of the generator protection panel imports are expected to be effective.