• Title/Summary/Keyword: Protection Relay

Search Result 343, Processing Time 0.028 seconds

Multi-Agent System having Adaptive Over Current Protection Function for Power Distribution Systems (멀티 에이전트 시스템 (Multi-Agent System)을 이용한 배전계통의 적응 과전류보호)

  • Chang, Choong-Koo;Lee, Seung-Jae;Lim, Dong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.8
    • /
    • pp.365-372
    • /
    • 2001
  • This paper presents a new protection concept to achieve the adaptive optimal function by introducing the multi-agent system technology. Making each relay an agent which consists of relay agent module and coordinator module, each agent works autonomously to improve protection capability by cooperating with other agents. It is applied to the overcurrent protection system of the industrial power system in order to show the feasibility of the proposed methodology.

  • PDF

A Study on the Digital DC Protection Relay through with Field Adoption Test in the DC Distribution System (직류급전시스템 시험적용 사례를 통한 디지털 직류 보호계전기에 관한 연구)

  • Ko, In-Suk;Cha, Kwang-Seok;Min, Byung-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.12
    • /
    • pp.646-652
    • /
    • 2006
  • This study identifies the comparison of Technical specification and Characteristics of DC Protection Relay(ETCPU200) used in DC Distribution System in Korea. ETCPU200 has completed Field Test and approved its capability by finding out causes of recent operations through lately developed digital DC protection relay in parallel operation at Maebong-Substation, Sangbong-Substation, Nakseongdae-Substation, Euljirosaga-Substation, Jegi-Substation and Chongyangri T/P area. It also examines additional features for efficient System Analysis and Operations.

Setting Method of a Percentage Current Differential Relay for Transformer Protection (변압기 보호용 전류비율차동 계전기의 동작영역 설정방법)

  • Kim, Su-Hwan;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.8-13
    • /
    • 2011
  • A percentage current differential relay is widely used for transformer protection. Because many percentage current differential relays recently use modified methods instead of conventional methods for deciding the operating characteristics of the large current region, in this paper, the operating region of a percentage current differential relay is analyzed in input-output current domain instead of operating-restraint current domain. An effective method to set the operating region when a CT is saturated is proposed with a series of investigations comparing a conventional method with the proposed modified method. The performance of the proposed method is evaluated for internal and external faults of a power transformer having the voltage rating of 345/154kV. EMTP-RV is used for the relaying data collection.

Examination with Transmission Line Distance Relay Setting Rule Considering Error (오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰)

  • Cho, Seong-Jin;Choi, Myeong-Song;Hyun, Seung-Ho;Kim, Joung-Wook;Lee, Joo-Wang;Cho, Bum-Sub;Yoo, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

Modified Current Differential Relay for Y-$\Delta$ Transformer Protection (Y-$\Delta$ 변압기 보호용 수정 전류차동 계전기)

  • Kang, Yong-Cheol;Jin, En-Shu;Lee, Byung-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.9-13
    • /
    • 2004
  • This paper proposes a modified current differential relay for Y-$\Delta$ transformer protection. The relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. A method to estimate the circulating component of the delta winding current is proposed. To cope with the remanent flux, before saturation, the core-loss current is calculated and used to modify the measured differential current. When the core then enters saturation, the initial value of the flux is obtained by inserting the modified differential current at the start of saturation into the magnetization cure. Thereafter, the core flux is then derived and used in conjunction with the magnetization curve to calculate the magnetizing current. A modified differential current is then derived that compensates for the core-loss and magnetizing currents. The performance of the proposed differential relay was compared against a conventional differential relay. Test results indicate that the modified relay remained stable during severe magnetic inrush and over-excitation because the exciting current was successfully compensated. The relay correctly discriminates magnetic inrush and over-excitation from an internal fault and is not affected by the level of remanent flux.

  • PDF

A Derivation of Comprehensive Protection Ratio and Its Applications for Microwave Relay System Networks

  • Suh Kyoung-Whoan
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.2
    • /
    • pp.103-109
    • /
    • 2006
  • This paper suggests an efficient and comprehensive algorithm of the protection ratio derivation and illustrates some calculated results applicable to the initial planning of frequency coordination in the fixed wireless access networks. The net filter discrimination associated with Tx spectrum mask and overall Rx filter characteristic has been also examined to show the effect of the adjacent channel interference. The calculations for co-channel and adjacent channel protection ratios are performed for the current microwave frequency band of 6.7 GHz including Tx spectrum mask and Rx filter response. According to results, fade margin and co-channel protection ratio reveal 41.4 and 75.2 dB, respectively, for 64-QAM and 60 km at BER $10^{-6}$. It is shown that the net filter discrimination with 40 MHz channel bandwidth provides 28.9 dB at the first adjacent channel, which yields 46.3 dB of adjacent channel protection ratio. In addition, the protection ratio of 38 GHz radio relay system is also reviewed for millimeter wave band applications. The proposed method gives some advantages of an easy and systematic extension for protection ratio calculation and is also applied to frequency coordination in fixed millimeter wave networks.

A Protection Ratio with Composite Fade Margin for Detailed Frequency Coordination in Microwave Relay System Network

  • Suh, Kyoung-Whoan
    • Journal of electromagnetic engineering and science
    • /
    • v.7 no.2
    • /
    • pp.83-90
    • /
    • 2007
  • In this paper, the formulation of the protection ratio based upon a composite fade margin and availability is newly presented for the detailed planning of frequency coordination in the microwave relay system network, and computed results for co-channel and adjacent channel protection ratios are illustrated over an actual system with 6.2 GHz. It is shown that the protection ratio to assure a quality of service can be expressed in terms of the composite fade margin, noise-to-interference ratio, net filter discrimination, and system parameters. In addition, the net filter discrimination, depending upon the transmitter spectrum mask and the overall receiver filter characteristic, has been examined to investigate the effect of the adjacent channel protection ratio caused by the adjacent channel interference. Regarding simulated results for 6.2 GHz, 60 km, 64-QAM, and N/I=6 dB at the bit error rate of $10^{-6}$, composite fade margin and co-channel protection ratio yield 25.14 and 50.3 dB, respectively. Also, the net filter discrimination of 26.5 dB and the adjacent channel protection ratio of 23.8 dB are obtained at the first adjacent channel of 30 MHz. The proposed method provides some merits in view of a comprehensive and practical application with more detailed and various system parameters needed to access the criteria for making the proper frequency coordination.

The Study of Fast Frequency Measurement Technique for Protection Relay (계전기를 위한 고속의 주교수 계측 알고리즘)

  • Kim, Beung-Jin;Lee, Chang-Ho;Park, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.211-213
    • /
    • 2005
  • In this paper, the frequency compensator for digital protective relay is introduced. Due to sudden appearance of generation-load or fault in power system, the frequency can deviate from its nominal value. The Orthogonal filter adopted to digital protective relay is exposed to the problem. Therefore, the frequency variation makes a difficult to protective function and power measurement in digital protective relay. The essential property of the proposed algorithm presented is its outstanding immunity to both signal orthogonal component magnitudes and DFT filter gain variations which ensures below 0.05Hz accuracy of estimation. Additionally, the proposed method has excellent characteristics with low signal sampling rate. Based on the frequency estimation, author design under frequency protection relay for generator and verifies its performance with several experimental tests.

  • PDF

Power Monitoring and Distributed Control by Digital Relay (디지털 계전기를 이용한 전력감시 및 분산제어)

  • Lee, Sung-Hwan;Park, Sang-Bae;Ahn, Ihn-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.263-266
    • /
    • 2001
  • In this paper, intelligent methods using digital protection relay in power SCADA system is developed in order to protect power systems by means of timely fault detection during operation and control at starting for induction motor which have various load environments and capacities in power systems. The digital protective relay was designed with DSP CPU(TMS320C31) to protect and measure more quickly and precisely. The test result on the basis of KEMC 1120 and IEC60255, show that the operation time error of the digital motor protection relay is improved within ${\pm}5%$. Also, we can control motors at starting according to starting types with simple method as programmable sequence editor. So we can improve the demerits of high cost and much manhour for rework.

  • PDF

A Study on Protection system to the Load Characteristics on the AC Feeder System (부하 특성에 따른 교류 급전시스템에서의 보호방식 연구)

  • Jung Ho-Sung;Han Moon-Seob;Lee Chang-Mu;Kim joorak
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1370-1372
    • /
    • 2004
  • At present. distance relay and ${\Delta}I$ current increment relay are used as primary and secondary protection in the AC feeder system. However. electric railway vehicles according to power electronic's development had developed resistance control, thyristor phase control and PWM control system. and operation of train is increasing in a feeder section. Therefore this paper analyzes the load characteristics and situation of relay's maloperation caused by load current increase, harmonics, regenerative braking current and operation of the different vehicles in same feeder section. Based on this analysis. this paper proposes consideration items for relay correction and advanced adaptive relay that can change operation area according to load current.

  • PDF