• Title/Summary/Keyword: Protection Rate

Search Result 1,733, Processing Time 0.032 seconds

The effect of inhibitors affecting to corrosion behaviors and hydrogen embrittlement behaviors due to over-propection of a 4340 steel in 3% NaCl solution (3% NaCl용액중에 있어서 4340강의 부식거동과 과방식에 의한 수소포화거동에 미치는 인히비타의 영향)

  • 문경만;백태실;이상태
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.54-62
    • /
    • 1989
  • When some kinds of inhibitors, i.e. $1{\times}10{-3}mol/l$ arsenic trioxide, 0.2 mol/l 2-mercaptoethanol, 0.2mol/l thiourea were added to 3% NaCl solution, there were some considererable effects to decrease corrosion current density in natural potential condition and the effect fo solution temperature increasing corrosion rate was smaller than that of no addition to 3% NaCl solution. However the susceptibility of hydrogen embrittlement due to over-protection in case of cathodic protection was much greater than that of no addition, especially was the greatest in case of addition of 2-mercaptoethanol. Therefore adding inhibitors for anti-corrosion effect, it is suggested that selection of the optimum protection potential is important from the view point of prevention against hydrogen embrittlement due to over-protection in case of cathodic protection.

  • PDF

Cathodic Protection Behavior of Coastal Bridge Structure with Sacrificial Anode Cathodic Protection System (희생양극식 음극방식이 적용된 해안 교량 구조물의 방식거동)

  • Ha, Ji-Myung;Jin, Chung-Kuk;Jeong, Jin-A
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.242-246
    • /
    • 2012
  • This measurement represents the effectiveness of sacrificial anode cathodic protection (SACP) system in a coastal bridge structure. To verify the cathodic protection (CP) effect, the monitoring sensor (DMS-100) that could measure potential, corrosion rate, current, concrete resistivity, and temperature was embedded. The measurement conducted for three years after CP system was installed. Specifically, due to the fact that fresh water and sea water was repeated in the bridge structure, this bridge structure presented special CP behavior. Measurement factors were CP potential, CP current, concrete resistivity, and depolarization potential. In addition, visual inspection was also carried out. As a result of current and depolarization measurement, CP system was well activated in most piers.

Investigation on optimum protection potential of high-strength Al alloy(5456-H116) for application in ships (선박용 고강도 Al합금(5456-H116)의 최적 방식 전위결정에 관한 연구)

  • Kim Sung-Jong;Ko Jae-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.157-168
    • /
    • 2006
  • Recently, interest in using Al alloys in ship construction instead of fiber-reinforced plastic (FRP) has increased because of the advantages of A) alloy ships over FRP ships, including high speed, increased load capacity. and ease of recycling. This paper investigated the mechanical and electrochemical properties of Al alloys in a slow strain rate test under various potential conditions. These results will provide reference data for ship design by determining the optimum protection potential regarding hydrogen embrittlement and stress corrosion cracking. In general, Al and Al alloys do not corrode on formation of a film that has resistance to corrosion in neutral solutions. In seawater, however, $Cl^-$ ions lead to the formation and destruction of a Passive film. In a potentiostatic experiment. the current density after 1200 sec in the Potential range of $-0.68\~-1.5\;V$ was low. This low current density indicates the protection potential range. Elongation at an applied potential of 0 V was high in this SSRT. However, corrosion protection under these conditions is impossible because the mechanical properties are worse owing to decreased strength resulting from the active dissolution reaction in parallel parts of the specimen. A film composed of $CaCO_3\;and\;Mg(OH)_2$ confers corrosion resistance. However, at potentials below -1.6 V forms non-uniform electrodeposition coating, since there is too little time to form a coating. Therefore, we concluded that the mechanical properties are poor because the effect of hydrogen gas generation exceeds that of electrodeposition. Comparison of the maximum tensile strength, elongation, and time to fracture indicated that the optimum protection potential range was from -1.45 to -0.9 V (SSCE).

A Study of Hydrogen Embrittlement Limit Potential of Cu-Containing High Strength Low Alloy Steel for Marine Structure by Potentiostatic SSRT Method (정전위 SSRT법에 의한 해양구조물용 Cu함유 고장력저합금강의 수소취성한계전위 규명에 관한 연구)

  • 김성종;박태원;심인옥;김종호;김영식;문경만
    • Journal of Welding and Joining
    • /
    • v.19 no.2
    • /
    • pp.182-190
    • /
    • 2001
  • A marine structural material was well known to have high tensile strength, good weldability and proper corrosion resistance. Cu-containing high strength low alloy(HSLA) steel was recently developed for their purposes mentioned above. And the steel is free about preheating for welding, therefore it is reported that shipbuilding cost by using it can be saved more or less. However the marine structural materials like Cu-containing HSLA steel are being generally adopted with cathodic protection method in severe corrosive environment like natural sea water but the high strength steel may give rise to Hydrogen Embrittlement due to over protection at high cathodic current density for cathodic protection. In this study Cu-containing HSLA steel using well for marine atructure was investigated about the susceptibility of Hydrogen Embrittlement as functions of tensile strength, strain ratio, fracture time, and fracture mode, etc. and an optimum cathodic protection potential by slow strain rate test(SSRT) method as well as corrosion properties in natural sea water. And its corrosion resistance was superior to SS400 steel, but Hydrogen Embrittlement susceptibility of Cu-containing HSLA steel was higer than that of SS400 steel. However Hydrogen Embrittlement of its steel by SSRT method was showed with pheonomena such as decreasing of fracture time, strain ratio and fracture mode of QC(quasi-cleavage). Eventually it is suggested that an optimum cathodic protection potential not presenting Hydrogen Embrittlement of Cu-containing of HSLA steel by SSRT method was from-770mv(SCE) to - 900mV(SCE)under natural sea water.

  • PDF

An Analysis of Recognition on Personal Information Protection among Healthcare Administration Students in the Information Society (정보사회에서 보건행정 전공 대학생들의 개인정보보호에 대한 인지 분석)

  • Kim, Ji-On;Park, Ji-Kyeong
    • Journal of Digital Convergence
    • /
    • v.12 no.5
    • /
    • pp.325-334
    • /
    • 2014
  • The purpose of this study was to examine the recognition of health administration students on personal information protection in an effort to be of use for raising awareness of personal information protection in students and for having them practice it in the right way. The subjects in this study were 687 college students who majored in health administration. A survey was conducted from December 3, 2012, to June 21, 2013. As a result, it's found that just 17.2 percent were cognizant of the personal information protection act. As for recognition and practice of personal information protection domain, the students who were aware of the personal information protection act significantly excelled the others who weren't in every area of recognition and practice, and there was a positive correlation between the level of practice, as better recognition led to better practice. The awareness rate of information for a personal identification stood at 57.0 percent, and the awareness rate of personal information to be managed stood at 53.7 percent, which were both at an intermediate level. To raise awareness of the personal information protection act in health administration students, a course that can deal with this act should separately be offered so that they could have the right understanding of personal information protection and practice it properly.

Symbol Error Rate of 16-APSK Modulation (DVB-S2의 16-APSK 성능 분석)

  • Son, Jae-Seung;Lee, Yu-Sung;Park, Hyun-Cheol
    • Proceedings of the IEEK Conference
    • /
    • 2004.06a
    • /
    • pp.11-14
    • /
    • 2004
  • Digital Video Broadcasting - Satellite (DVB-S) [1] (EN 300 421(bibliography)) was introduced as a standard in 1994. However, by combing with higher order modulation, promise more powerful alternatives to the DVB-S / DVB-DSNG coding and modulation schemes. Variable rate coding and modulation (VCM) may employed to provide different levels of error protection to different service components. Adaptive coding and modulation (ACM) provides more exact channel protection and dynamic link adaptation to propagation conditions, targeting each individual receiving terminal. By these reasons, DVB-S2 introduced. This paper derives exact symbol error rate(SER) of 16-Amplitude Phase Shift Keying(APSK) modulation by using Craig's formula. 16-APSK modulation is used in DVB-S2. The difference between Union Bound and Craig's formula is 1.26dB in low SNR and 0.1dB in high SNR.

  • PDF

Determination of Environmental Radiation Dose Rate in the Southeastern Korea (우리나라 남동지방(南東地方)의 환경방사선(環境放射線) 선량율(線量率)의 결정(決定)(1980년도(年度)))

  • Rho, Chae-Shik;Lee, Hyun-Duk
    • Journal of Radiation Protection and Research
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 1980
  • A portable count-ratemeter and a thermoluminescent detector ($CaSO_4:Dy$) have been used to obtain total gamma dose rates at approximately 50 locations during the course of several survey trips in the southeastern Korea. The purposes of these measurement were to provide a future reference data and to establish the approximate range of population exposure to the natural environmental radiation. The natural levels encountered ranged from a low of 14.6 microroentgen per hour to a high of 18.9 microroentgen per hour with a mean of $16.3{\pm}1.0$ microroentgen per hour. Among these results are the relatively high natural dose rate levels in the Masan area and Yangsan-Tongdosa area with the relatively low natural dose rate levels in the Gyeongsan-Cheongdo area and the Samrangjin-Jinyeong-Gimhae area.

  • PDF

Dyeing of Natural Fibers with Extract of Ginkgo biloba Bark(II) - Fastness and Functional Characteristics of Dyed Fabrics - (은행나무 수피 추출액에 의한 천연섬유의 염색(II) -염색물의 견뢰성 및 기능성-)

  • 최순화;조용석
    • Textile Coloration and Finishing
    • /
    • v.13 no.6
    • /
    • pp.359-366
    • /
    • 2001
  • In this study, wool, silk and cotton fabrics were dyed with natural dyes derived from Ginkgo biloba bark using various mordants, and their dyeabilities were discussed. Additionally the fastness to washing, perspiration, light, rubbing, and drycleaning were investigated. And the effects of bacteria reduction and UV-B protection rate were also checked. The optimum dyeing condition of the colorants extracted from the Ginkgo biloba bark was three repeated dyeing at$95^\circ{C}$ for 1 hr. by using post mordanting. Mordanting improved the fastness to washing, Perspiration and drycleaning, but the fastness to light and rubbing were not increased. The bacteria reduction rate of the wool fabric increased drastically by dyeing with extract of Ginkgo biloba bark and its effect maintained after repeated washing and drycleaning. UV-B protection rate of the natural fibers increased by dyeing with extract of Ginkgo biloba bark and the dyed wool fabric was the best of the three fabrics.

  • PDF

Dyeing of Natural Fibers with Extract of Ginkgo biloba Bark(Ⅱ) - Fastness and Functional Characteristics of Dyed Fabrics - (은행나무 수피 추출액에 의한 천연섬유의 염색(Ⅱ) - 염색물의 견뢰성 및 기능성 -)

  • Choe, Sun Hwa;Jo, Yong Seok
    • Textile Coloration and Finishing
    • /
    • v.13 no.6
    • /
    • pp.1-1
    • /
    • 2001
  • In this study, wool, silk and cotton fabrics were dyed with natural dyes derived from Ginkgo biloba bark using various mordants, and their dyeabilities were discussed. Additionally the fastness to washing, perspiration, light, rubbing, and drycleaning were investigated. And the effects of bacteria reduction and UV-B protection rate were also checked. The optimum dyeing condition of the colorants extracted from the Ginkgo biloba bark was three repeated dyeing at 95℃ for 1 hr. by using post mordanting. Mordanting improved the fastness to washing, Perspiration and drycleaning, but the fastness to light and rubbing were not increased. The bacteria reduction rate of the wool fabric increased drastically by dyeing with extract of Ginkgo biloba bark and its effect maintained after repeated washing and drycleaning. UV-B protection rate of the natural fibers increased by dyeing with extract of Ginkgo biloba bark and the dyed wool fabric was the best of the three fabrics.

A Study on the Information Disclosure of Financial services Using Content Analsysis (금융상품정보제공 실태파악을 위한 금융상품팜플렛 내용분석)

  • 허은영;최현자
    • Journal of the Korean Home Economics Association
    • /
    • v.38 no.11
    • /
    • pp.63-75
    • /
    • 2000
  • To identify the actual situation of financial information disclosure, a content analysis was performed on pamphlets of a time deposit and a new reserve trust offered by banks and other financial institutes. Although consumers required information on interest rate, tax favor, loan service, protection of brink depositors and bank security to select a financial service account, informations offered on pamphlets are not sufficient. Therefore concrete way of information offer system shoed be developed. In offering interest rate, interest rate after tax deduction or payment at maturity should be also mentioned. Information on tax favor, protection of bank depositors and bank security should be contained in pamphlets as well. Use of easy terms and notes are recommended for developing pamphlets for financial products.

  • PDF