• Title/Summary/Keyword: Prosthetic Implants

Search Result 218, Processing Time 0.021 seconds

Consideration on the esthetic problems from implant cases (임플란트 증례에서 발생하는 심미적 문제점들에 관한 고찰)

  • Lee, Dong-Hyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.39-48
    • /
    • 2015
  • The critical factors affecting the esthetics of anterior implants can be summarized as following: 1) Correct positioning of implant fixture, 2) Enough amount of alveolar bone, 3) Optimum volume of soft tissue. The position of implant is probably the most important factor in obtaining esthetic treatment outcome. The 3-dimensional orientation of implant is determined by the position on the alveolar ridge and its direction. Clinicians often try to mimic natural teeth when fabricating restorations. During the course of esthetic diagnosis and treatment, however, one should not forget to consider the correlation between facial pattern, lips, gingiva, alveolar ridge, as well as remaining dentition. Since anterior region is biologically unfavorable when compared with posterior region, one minor discrepancy in positioning of implant can cause esthetically undesirable treatment outcome. If one understands the biological and prosthetic meaning of implant' s 3-dimensional position, he or she can achieve superior esthetic outcome in anterior region.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF METAL-CERAMIC VERSUS COMPOSITE RESIN-VENEERED METAL CROWNS IN CEMENT-RETAINED IMPLANT-SUPPORTED CROWNS UNDER VERTICAL COMPRESSIVE LOAD

  • Pae, Ahran;Jeon, Kyung-A;Kim, Myung-Rae;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.295-302
    • /
    • 2007
  • Statement of problem. Fracture of the tooth-colored superstructure material is one of the main prosthetic complications in implant-supported prostheses. Purpose. The purpose of this in vitro study was to compare the fracture strength between the cement-retained implant-supported metal-ceramic crowns and the indirect composite resinveneered metal crowns under the vertical compressive load. Material and methods. Standard implants of external type (AVANA IFR 415 Pre-mount; Osstem Co., Busan, Korea) were embedded in stainless steel blocks perpendicular to their long axis. Customized abutments were fabricated using plastic UCLA abutments (Esthetic plastic cylinder; Osstem Co., Busan, Korea). Thirty standardized copings were cast with non-precious metal (Rexillium III, Pentron, Walling ford, Conn., USA). Copings were divided into two groups of 15 specimens each (n = 15). For Group I specimens, metal-ceramic crowns were fabricated. For Group II specimens, composite resin-veneered (Sinfony, 3M-ESPE, St. Paul, MN, USA) metal crowns (Sinfony-veneered crowns) were fabricated according to manufacturer's instructions. All crowns were temporary cemented and vertically loaded with an Instron universal testing machine (Instron 3366, Instron Corp., Norwood, MA, USA). The maximum load value (N) at the moment of complete failure was recorded and all data were statistically analyzed by independent sample t-test at the significance level of 0.05. The modes of failure were also investigated with visual analysis. Results. The fracture strength of Sinfony-veneered crowns ($2292.7{\pm}576.0N$) was significantly greater than that of metal-ceramic crowns ($1150.6{\pm}268.2N$) (P < 0.05). With regard to the failure mode, Sinfony-veneered crowns exhibited adhesive failure, while metal-ceramic crowns tended to fracture in a manner that resulted in combined failure. Conclusion. Sinfony-veneered crowns demonstrated a significantly higher fracture strength than that of metal-ceramic crowns in cement-retained implant-supported prostheses.

Full mouth rehabilitation of severely worn dentition using posterior implants: a clinical report (심하게 마모된 치열의 구치부 임플란트 식립을 통한 전악 수복 증례)

  • Kang, Hyun-Sun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.255-262
    • /
    • 2016
  • This clinical report focuses on the treatment of a patient with esthetic and functional impairments due to severe worn dentition. Absence of posterior support for a prolonged period require comprehensive prosthetic restoration. Accurate clinical and radiographic examinations, diagnostic wax-up, and occlusal vertical dimension evaluation were performed and the degree of patient adaptability was evaluated using an interim restoration. After 8 weeks of stabilization with interim restoration and confirmation of absence of any abnormal findings, definitive prostheses were fabricated. Satisfactory functional and esthetic outcomes were observed after 6 months of follow-up.

Immediate implant placement and provisionalization of single implant in the esthetic region : Cases report (심미적 영역에서 즉시 임플란트 식립 및 임시 수복을 통한 단일치의 수복에 대한 증례 보고)

  • Lee, Song-Bea;Park, Yu-Seon;Kim, Byoung-Heon;Lee, Bo-Ah;Choi, Seong-Ho;Kim, Young-Taek
    • The Journal of the Korean dental association
    • /
    • v.58 no.2
    • /
    • pp.83-92
    • /
    • 2020
  • In the anterior maxillary area, dental implants for tooth replacement are challenging due to the need to satisfy high esthetic level as well as functionality. Immediate implant placement and provisionalization can dramatically reduce the edentulous period, and then fulfill patient's demand for esthetics. The aim of present case report is to demonstrate two cases that successfully restored single tooth with immediate implant placement and provisionalization in the anterior maxillary area. A 47 years old female was scheduled to replace her maxillary right central incisor due to crown-root fracture by trauma. Another 54-year-old female was planned to place dental implant following tooth extraction of maxillary right lateral incisor owing to continuous pus discharge despite repetitive treatments including apicoectomy. In these two cases, surgical and prosthetic procedures progressed in a similar way. After minimal flap elevation, atraumatic tooth extraction was performed. Implant was placed in proper 3-dimensional position and angulation with primary stability. Bone graft or guided bone regeneration for peri-implant bone defect was conducted simultaneously. Provisionalization without occlusal loading was carried out at the same day. Each definitive crown was delivered at 7 and 5 months after the surgery. Two cases have been followed uneventfully for 2 to 5 years of loading time. In conclusion, Immediate implant placement and provisionalization could lead to esthetic outcome for single tooth replacement with dental implant under proper case selection.

  • PDF

Multidisciplinary approach of the problem of unaesthetic implants in the maxillary anterior dentition (비심미적 임플란트의 심미성 회복을 위한 다각적 접근법)

  • Joo, Ji-Young;Choi, Jeomil;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.126-133
    • /
    • 2015
  • Periodontal tissue destroyed by inflammation is difficult to achieve regeneration of the tissue and esthetic restorations only by surgical methods. In particular, improvement of esthetics is more difficult if the problem is related to the implant. A 23 year old woman suffered from unesthetic anterior implant prosthesis. According to her dental history, a repeated bone graft and soft tissue graft failed at a local dental clinic. It was needed to resolve the inflammation and to improve the esthetics. A free gingival graft and ridge augmentation accompanied by guided bone regeneration and a vascularized interpositional periosteal connective tissue graft was performed. Instead of implant prosthesis, a conventional fixed bridge was adopted for better esthetic result. The patient was satisfied with the esthetic conventional fixed prosthesis. This case report introduces esthetic rehabilitation of unesthetic implant prosthetics in the maxillary anterior dentition by a combination of surgical and prosthetic approaches.

Prosthetic treatment for patient with anterior overbite and partial edentulism using maxillary hybrid telescopic double crown RPD and mandibular fixed prostheses: A 11-yr follow-up (전치부 과개교합을 가진 상하악 부분 무치악 환자에서의 상악 하이브리드 텔레스코픽 이중관 국소의치와 하악 고정성 보철물을 이용한 치료의 11년 경과관찰 증례)

  • Choi, Hyunsuk;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.415-421
    • /
    • 2021
  • The biomechanical prognosis of conventional removable partial denture is questionable in case of patient with few remaining teeth or periodontally compromised teeth. In this case, hybrid telescopic double crown RPD may be a successful treatment alternative. Hybrid telescopic double crown RPD has following advantages over conventional RPD: secondary splinting effect between abutments, more vertical stress direction and more convenient in repairing the denture after extraction of abutment tooth. In this clinical case, patient had deep overbite in anteriors and partially edentulous. The maxilla was restored with hybrid telescopic double crown RPD and the mandible was restored with implants and fixed prostheses. Long-term follow-up and supportive periodontal treatment were performed, and satisfactory results were achieved in terms of function and aesthetics.

Load response of the natural tooth and dental implant: A comparative biomechanics study

  • Robinson, Dale;Aguilar, Luis;Gatti, Andrea;Abduo, Jaafar;Lee, Peter Vee Sin;Ackland, David
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.3
    • /
    • pp.169-178
    • /
    • 2019
  • PURPOSE. While dental implants have displayed high success rates, poor mechanical fixation is a common complication, and their biomechanical response to occlusal loading remains poorly understood. This study aimed to develop and validate a computational model of a natural first premolar and a dental implant with matching crown morphology, and quantify their mechanical response to loading at the occlusal surface. MATERIALS AND METHODS. A finite-element model of the stomatognathic system comprising the mandible, first premolar and periodontal ligament (PDL) was developed based on a natural human tooth, and a model of a dental implant of identical occlusal geometry was also created. Occlusal loading was simulated using point forces applied at seven landmarks on each crown. Model predictions were validated using strain gauge measurements acquired during loading of matched physical models of the tooth and implant assemblies. RESULTS. For the natural tooth, the maximum vonMises stress (6.4 MPa) and maximal principal strains at the mandible ($1.8m{\varepsilon}$, $-1.7m{\varepsilon}$) were lower than those observed at the prosthetic tooth (12.5 MPa, $3.2m{\varepsilon}$, and $-4.4m{\varepsilon}$, respectively). As occlusal load was applied more bucally relative to the tooth central axis, stress and strain magnitudes increased. CONCLUSION. Occlusal loading of the natural tooth results in lower stress-strain magnitudes in the underlying alveolar bone than those associated with a dental implant of matched occlusal anatomy. The PDL may function to mitigate axial and bending stress intensities resulting from off-centered occlusal loads. The findings may be useful in dental implant design, restoration material selection, and surgical planning.

3-D Finite element stress analysis in screw-type, cement-type, and combined-type implant fixed partial denture designs (임플란트 상부보철물의 유지형태에 따른 3차원 유한요소 응력분석)

  • Lee, Sung-Chun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.365-375
    • /
    • 2009
  • Statement of problems: Stress analysis on implant components of the combined screw- and cement-retained implant prosthesis has not investigated yet. Purpose: The purpose of this study was to assess the load distribution characteristics of implant prostheses with the different prosthodontic retention types, such as cement-type, screw-type and combined type by using 3-dimensional finite element analysis. Material and methods: A 3-dimensional finite element model was created in which two SS II implants (Osstem Co. Ltd.) were placed in the areas of the first premolar and the first molar in the mandible, and three-unit fixed partial dentures with four different retention types were fabricated on the two SS II implants. Model 1 was a cement-retained implant restoration made on two cement-retained type abutments (Comocta abutment; Osstem Co. Ltd.), and Model 2 was a screw-retained implant restoration made on the screw-retained type abutments (Octa abutment; Osstem Co. Ltd.). Model 3 was a combined type implant restoration made on the cement-retained type abutment (Comocta abutment) for the first molar and the screw-retained type abutment (Octa abutment) for the first premolar. Lastly, Model 4 was a combined type implant restoration made on the screw-retained type abutment (Octa abutment) for the first molar and the cement-retained type abutment (Comocta abutment) for the first premolar. Average masticatory force was applied on the central fossa in a vertical direction, and on the buccal cusp in a vertical and oblique direction for each model. Von-Mises stress patterns on alveolar bone, implant body, abutment, abutment screw, and prosthetic screw around implant prostheses were evaluated through 3-dimensional finite element analysis. Results: Model 2 showed the lowest von Mises stress. In all models, the von Mises stress distribution of cortical bone, cancellous bone and implant body showed the similar pattern. Regardless of loading conditions and type of abutment system, the stress of bone was concentrated on the cortical bone. The von-Mises stress on abutment, abutment screw, and prosthetic screw showed the lower values for the screw-retained type abutment than for the cement-retained type abutment regardless of the model type. There was little reciprocal effect of the abutment system between the molar and the premolar position. For all models, buccal cusp oblique loading caused the largest stress, followed by buccal cusp vertical loading and center vertical loading. Conclusion: Within the limitation of the FEA study, the combined type implant prosthesis did not demonstrate more stress around implant components than the cement type implant prosthesis. Under the assumption of ideal passive fit, the screw-type implant prosthesis showed the east stress around implant components.

Relationship of Oral Health Status and Oral Health Care to the Quality of Life in Patients of Dental Hospitals and Clinics (치과내원 환자들의 구강건강상태와 구강건강관리 행태에 따른 삶의 질)

  • Yoon, Hyun-Seo
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.594-602
    • /
    • 2015
  • The purpose of this study was to examine the relationship of oral health status and oral health care to life. The subjects in this study were the patients who visited dental hospitals and clinics in several regions for seven months from March 2013. They got dental checkups, and a survey was conducted. The patients who received general treatment scored highest in Oral Health Impact Profile-14. Among the subfactors, the patients who received general treatment scored higher in functional limitation (8.27), physical pain (7.24), physical restrictions (7.90), social restrictions (7.79), physical limitations (8.14) and social difficulties (8.24). The patients who received orthodontic treatment scored higher in handicap (8.78). All the differences were statistically significant. As for gender gaps, the men scored higher in every factor. By age group, the older patients led a worse quality of life. By occupation, the homemakers mostly led a worse quality of life, and the patients who had no systemic diseases lived a better quality of life. All the differences were significant. Concerning self-rated health status and self-rated oral health state, the patients who found themselves to be in better health and in better oral health led a better quality of life. The differences were significant. Regarding oral health care, the patients who didn't get regular dental checkups and who could visit a dental clinic whenever they had a pain lived a better quality of life. The differences were significant. In terms of oral health status, a higher quality of life was found among the patients who had sound teeth, whose teeth received no sealant treatment, whose teeth received no filling therapy, who had no missing tooth, whose teeth received no prosthetic treatment and who had no dental implants teeth.

Functional and Radiological Results of Intermediate-term Follow Up in $MUTARS^{(R)}$ Tumor Endoprostheses ($MUTARS^{(R)}$ 종양 대치물을 이용한 사지 구제술의 기능적 및 방사선학적 중기 추시 결과)

  • Kang, Dong-Joon;Kim, Jeung-Il;Oh, Jong-Seok;Moon, Tae-Yong;Lee, In-Sook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • Purpose: This study was designed to verify intermediate-term functional and radiological results of limb salvage operation using endoprosthetic replacement system ($MUTARS^{(R)}$) used in patients with a malignant bone tumor. Materials and Methods: Thirty one cases which used $MUTARS^{(R)}$ tumor prosthesis were reviewed. The mean age of the patients was 49.2 years and the mean follow up was 39.8 months. We retrospectively reviewed complications, and evaluated functionally and radiologically by Enneking functional score, ISOLS radiological implants evaluation system at last follow-up. Results: 3 patients had died of disease, distant metastasis was seen in 4 patients and local recurrence was seen in 1 patients. Complications were developed in 12 patients. (infection 6, leg length discrepancy 2, aseptic loosening 2, periprosthetic femoral fracture 1, screw loosening 1) Mean value of total functional scores were 81.2% in proximal femur, 77.4% in distal femur, 78.1% in proximal tibia, and 80.2% in proximal humerus. The overall radiological result was relatively satisfactory. Conclusion: Our results suggest limb salvage with the $MUTARS^{(R)}$ endoprosthesis is successful with good functional and radiological results. But we should be careful with complications such as infection.