• 제목/요약/키워드: Prosthesis type

검색결과 250건 처리시간 0.029초

Rehabilitation of Partial Edentulism with a Crown-type Implant-assisted Removable Partial Denture through Guided Implant Surgery: A Case Report with a 12-month Follow-up

  • Jun, Ji Hoon;Oh, Kyung Chul;Li, Jiayi;Moon, Hong Seok
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.75-83
    • /
    • 2022
  • Crown-type implant-assisted removable partial dentures (CIRPDs) can be a feasible treatment option for partially edentulous patients. Here we report a case with remaining unilateral mandibular teeth. Two implants were placed in the posterior portion of the mandible using a surgical guide, and a distal-extension removable partial denture with implant-supported surveyed crowns was fabricated. After 12 months, both the abutment teeth and implants were in good condition. The treatment outcomes were satisfactory in terms of masticatory function and esthetics. The advantages of CIRPDs and considerations for obtaining successful clinical outcomes with these dentures are also discussed.

종양 대치물을 이용한 사지 구제술의 방사선학적 평가 (Radiologic Evaluation of Limb Salvage Operation with Tumor Prosthesis)

  • 문상호;이상훈;김한수;오주한;고병원;구기형;이재학;황정수;이한구
    • 대한골관절종양학회지
    • /
    • 제6권4호
    • /
    • pp.152-162
    • /
    • 2000
  • 목적 : 악성 골종양의 종양 대치물을 이용한 사지 구제술에서 방사선학적 변화를 평가하는 데 목적이 있다. 대상 및 방법 : 종양 대치물로써 사지 구제술을 받은 69례를 대상으로 하였고 평균 추시 기간은 4년 9개월이었다. International Symposium On Limb Salvage(ISOLS)에서 제창한 방사선학적 대치물 평가 체계(Radiological Implants Evaluation System)를 사용하여 평가하였으며 술후 1년 및 최종 추시로 나누어 시행하였다. 우수, 양호, 보통, 불량을 각각 통계분석을 위해 4, 3, 2, 1로 변환하여 분석하였고 평가 결과를 시멘트 사용 여부, 병변의 위치, 종양의 종류, 종양 대치물의 종류 및 나이(<20세 vs ${\geq}$20세)에 따라 나누어 T-test 및 ANOVA를 사용하여 비교 분석하였다. 결과 : 최종 추시에서 시멘트군이 무시멘트군보다 골 재형성 및 접촉면 항목에서 우수했으나 고정 항목(anchorage)에서는 무시멘트군이 우수했다. 병변의 위치 상 근위 대퇴부 및 원위 경골부가 다른 부위보다 골 재형성면에서 불리하였으며 골육종군이 비골육종군보다 고정 및 관절면에서 불리하였다. 대치물의 종류 및 연령에 따른 유의한 차이는 없었다. 결론 : 방사선학적 중기 추시상, 시멘트를 이용한 재건술이 골 흡수 및 해리에서 더 우수하였고 무시멘트 술식은 고정(anchorage) 면에서 우수하였다. 원위 대퇴골 및 근위 경골이 골 흡수면에서 유리한 해부학적 위치였으며 골육종군은 화학요법으로 인해 고정 및 관절면에서 불리하였다고 생각한다.

  • PDF

임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구 (Strains of abutment and bones on implant overdentures)

  • 김명석;허성주;곽재영;김성균
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.222-231
    • /
    • 2009
  • 연구목적: 임플란트 피개의치에서 연결고정형과 비연결고정형 보철물 지대주와 골의 변형률을 비교하고 임플란트 식립 경사에 따른 변형률을 비교 분석하고자 하였다. 연구 재료 및 방법: 2개의 아크릴릭 레진 모형의 좌측과 우측 견치 부위에 2개의 외부연결형 임플란트를 각각의 모형에 식립하였다. 한 모형에는 두 개의 임플란트를 평행하게 식립하였고, 다른 모형에는 순측과 설측으로 10도의 이개도(divergence)를 가지게 임플란트를 식립하였다. 모형에서 바를 이용한 연결고정형 지대주와 볼을 이용한 비연결고정형 지대주를 고정체에 번갈아 연결하고, 각각의 경우 대응하는 유지장치가 부착된 피개의치를 제작하여 지대주 상에 안착시켰다. 전기저항 스트레인 게이지(strain gauge)를 이용하여 피개의치에 100 N에서 200 N의 부하를 가하였을 때 지대주와 가상골 표면의 변형률(strain)을 측정하였다. 결과 및 결론: 측정된 값들을 통계분석하여 얻은 결과는 다음과 같다. 바를 이용한 연결고정형 보철물은 비연결형 보철물 보다 높은 변형률 값을 보였다. 그러나 방향은 주로 압축력이었으며 부하는 분산되었다(P<.05). 볼을 이용한 비연결고정형 보철물은 연결고정형보다 낮은 변형률 값을 보였다(P<.05). 순측경사된 임플란트에서는 비연결고정형 보철물이 연결고정형 보철물보다 더 높은 변형률 값을 보였다. 설측경사된 임플란트는 순측경사된 임플란트보다 낮은 변형률을 보였다(P<.05). 임플란트가 평행하게 식립된 경우보다 평행하지 않게 식립된 경우 지대주와 가상골의 변형률 값이 더 높았다(P<.05).

무봉합 혈관내 인조이식혈관을 이용한 박리성 대동맥류의 수술요법 (Surgical Treatment for Dissecting Aneurysm of the Aorta using Sutureless Intraluminal graft)

  • 이재원
    • Journal of Chest Surgery
    • /
    • 제18권2호
    • /
    • pp.305-313
    • /
    • 1985
  • Surgical therapy for dissection of the aorta has had a high mortality. One contributing factor has been hemorrhage from the prosthesis and the suture lines. Recently, a new method of treatment with an intraluminal graft that requires no end-to-end anastomosis has been developed. Of the four patients with dissecting aneurysm of the aorta treated by inserting sutureless ringed intraluminal graft at the Department of Thoracic and Cardiovascular Surgery, S.N.U.H., three were DeBakey type I [one with associated aortic insufficiency] and the other was DeBakey type III. Suspected etiology of the dissection was Marfan`s syndrome in one and hypertension in the others. Total cardiopulmonary bypass was utilized in repairing dissecting aneurysms of the ascending aorta [type A] and simple aortic crossclamping was used for the patient with dissecting aneurysm of the descending aorta. The basic technique consists of inserting the whole ringed graft into the true lumen of the dissected aorta and circumferentially ligating the aorta against the groove in the rings. The proximal ring of the graft effectively stabilized the flail aortic valve in patient with aortic insufficiency associated with dissection of the ascending aorta. There were no hospital deaths and one patient with type III dissecting aneurysm developed postoperative paraparesis and renal insufficiency which was resolved. Follow-up has been from 1 month to 16 months with no evidence of prosthetic problems, such as erosion, migration, or thrombosis.

  • PDF

Surgical Experience of Persistent Type 2 Endoleaks with Aneurysmal Sac Enlargement after Endovascular Aneurysm Repair

  • Bang, Seung Ho;Park, Jae Bum;Chee, Hyun Keun;Kim, Jun Seok;Jang, Il Soo
    • Journal of Chest Surgery
    • /
    • 제47권2호
    • /
    • pp.167-170
    • /
    • 2014
  • Herein, we present a case of a successful treatment of persistent type 2 endoleaks associated with aneurysmal sac enlargement after endovascular aneurysm repair in an elderly patient. We confirmed the diagnosis by abdominal computed tomography and selective angiography revealing an 11.0-cm aneurysm sac with type 2 endoleaks. An attempt for the endovascular embolization of collateral arteries was unsuccessful due to anatomic variations and their multiple complex communications. Instead, transperitoneal sacotomy and direct suturing on the feeding target vessels was successfully performed without any endograft damage. In conclusion, sacotomy appears to be a feasible therapeutic substitute where endovascular or other techniques have a high risk of failure and lead to unsuccessful results.

수지접합 수복물용 합금의 피착면처리에 따른 결합력에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE BOND STRENGTH OF ETCHED CAST RESTORATION USING DIFFERENT METAL SURFACE TREATMENTS)

  • 이근우
    • 대한치과보철학회지
    • /
    • 제29권1호
    • /
    • pp.13-22
    • /
    • 1991
  • This study investigated the effects of surface treatment on the tensile bond strength of resinbonded prosthesis. The Rexillium III specimens were treated with $50{\mu}m\;Al_2O_3$ blasting. Type IV gold alloy specimens were treated with $400^{\circ}C$ heating and tin plating method. All specimens were bonded with MBAS composite resin cement and followed by immersion test into the $37^{\circ}C$ water bath for 7 days. The specimens were debonded in tension with an Instron machine and observed with SEM. The modes of failure were recorded also. The following conclusions were obtained : 1. The tensile bond strength decreased in following order. $50{\mu}m\;Al_2O_3$ basted Resillium III group, Type IV gold alloy group treated with $400^{\circ}C$ heat and tin plating type IV gold alloy group, and statistical significant differences were observed(p<0.05). 2. The tensile bond strength decreased in all groups after 7 days immersion test, but statistical significant differences were observed in Rexillium III specimens only. 3. The sharp and irregular surface were observed in Rexillium III, but $400^{\circ}C$ heat treated and tin plated groups had round and broad surface in SEM. 4. The models of bond failure were cohesive-adhesive failure mainly.

  • PDF

치과용 지르코니아 A3 착색제에 따른 색상 및 반투명도 차이 (Difference in color and translucency according to dental zirconia A3 colorant)

  • 이주희;박진영
    • 대한치과기공학회지
    • /
    • 제44권4호
    • /
    • pp.118-125
    • /
    • 2022
  • Purpose: The color of dental zirconia is very important in terms of aesthetics. To reproduce the color tone, a colorant is applied to zirconia to express the color tone. I would like to point out that the color, brightness, and saturation of the colorant used to express the color A3 may vary depending on the manufacturer. Methods: Each zirconia block received a total of 25 circular specimens for the experiment. The zirconia specimen was then deposited by colorant type to reproduce the color tone. Color differences and translucency were measured using a spectrophotometer. To compare and analyze the zirconia color according to the type of colorant, one-way ANOVA was used. Results: For each type of zirconia colorant, there was no statistically significant difference in translucency or b* (p>0.05). There was a statistical difference in L* and a* (p<0.05). Conclusion: The ΔE*ab (D65) value is less than 5.5 or less, and the color difference is within an acceptable range.

구치부 임플란트 고정성 수복물에서의 지대주 나사 풀림 현상과 이에 영향을 미치는 요인 (The incidence of the abutment screw loosening and its affecting factors in posterior implant restorations)

  • 홍수정;배정윤;김현희
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.212-217
    • /
    • 2018
  • 목적: 본 연구의 목적은 구치부 식립 임플란트에서 지대주 나사 풀림의 발생 빈도 및 지대주 나사 풀림에 영향을 주는 다양한 요인들을 후향적 연구를 통하여 평가하는 것이다. 대상 및 방법: 2013년 1월부터 2016년 1월까지 208명의 환자에서 구치부에 식립한 391개의 임플란트를 대상으로 하였다. 모든 수복물은 고정성으로 단일 혹은 연결 크라운, 브릿지로 제작되었으며, 임시 시멘트로 합착하였다. 전체 수복물 중 지대주 나사 풀림의 발생 빈도를 조사하였고, 성별, 보철물의 위치, 대합치, 보철물의 유형, 지대주 연결 유형, 매식체의 지름이 지대주 나사 풀림에 미치는 영향을 평가하였다. 결과: 2 - 5년의 관찰 결과, 총 29개(7.4%)의 임플란트에서 지대주 나사 풀림이 발생하였다. 최종 수복 후 지대주 나사 풀림이 발생하기까지 소요된 기간은 3개월부터 48개월(평균19.5개월)까지 다양하게 나타났으며, 이 중 3개의 임플란트에서 매식체의 파절이 발생되었다. 고려 요인들 중, 임플란트의 식립 위치에 따라 대구치(9.4%)와 소구치(2.6%)에서 통계적으로 유의한 차이를 보였으며(P < .019), 대합치에 따라 자연치(9.9%), 임플란트(1.0%), 가철성 보철물(0%)에서 유의한 차이를 보였다(P < .018). 다른 고려 요인에 따른 지대주 나사 풀림 발생 빈도는 통계적 유의성이 없었다. 결론: 구치부 임플란트 수복물에서 지대주 나사 풀림의 발생 빈도는 7.4%로 나타났다. 소구치보다 대구치에서 유의하게 높은 발생 빈도를 보였으며, 대합치에 따라서는 임플란트, 가철성 보철물과 비교 시 자연치에서 유의하게 높은 발생 빈도를 보였다.

제1대구치 위치에 식립된 단일 임플란트의 지대주 연결 유형에 따른 임플란트 주위골 흡수 (Marginal bone loss between internal- and external- abutment connection type implants placed in the first molar area)

  • 이석현;이은우;정하나;김옥수
    • 구강회복응용과학지
    • /
    • 제39권1호
    • /
    • pp.32-44
    • /
    • 2023
  • 목적: 이번 연구는 상·하악 제1대구치 부위에 식립 된 단일 임플란트를 통해 임플란트-지대주 연결 유형이 임플란트의 변연골 소실 (MBL)에 영향을 주는지, 그리고 MBL에 영향을 끼치는 요인들을 알아보기 위해 분석하였다. 연구 재료 및 방법: 5년 이상의 추적 기간 동안, 상·하악 제1대구치 부위에 단일 임플란트를 식립하여 수복한 68명의 환자(남: 38명, 여: 30명)의 87 임플란트(external connection type (EC) 임플란트: 57개, internal connection type (IC) 임플란트: 30개)를 대상으로 추적 조사하였다. 최대 5년 후의 구내 방사선 영상에서 MBL과 보철물의 출현 각도(EA)를 측정하였다. 60 - 79세에 해당하는 환자의 비율이 52.9%로 가장 높았고 상악 구치부에 임플란트가 가장 많이 식립되었다. 결과: GBR을 하지 않은 경우 EC (-0.065 ± 0.859 mm)와 IC (-0.627 ± 0.639 mm)에서 유의한 차이가 있었고, 또한 당뇨병이 없는 환자들 사이에서 EC (-0.131 ± 1.002 mm)와 IC (-0.792 ± 0.762 mm)에서 유의한 차이가 존재하였다. 임플란트 매식체의 직경, 길이, 보철물 연결 방법, 임플란트 제조업체, 보철물의 emergence angle (EA)로 구분하였을 때 각군 간에 유의미한 차이가 없었다. 다중회귀분석을 이용하여 MBL에 영향을 주는 요인분석 결과 회귀계수의 유의성 검증에서 임플란트-지대주 체결 방식(β = -0.303), 당뇨병의 유무(β = -0.113), EA의 차이(β = -0.234), 나이(β = -0.776)에서 MBL에 통계학적으로 유의한 음의 상관관계를 보였다. 결론: IC가 EC보다 GBR을 하지 않은 경우와 당뇨병이 없는 환자들 사이에서 MBL이 작다는 것을 알 수 있었다. 또한 보철물의 EA가 30°보다 큰 보철물의 형태를 가진 임플란트가 30°보다 작은 보철물의 형태를 가진 임플란트 보다 MBL이 컸으며 나이가 많을수록 MBL이 크다는 것을 알 수 있었다. 임플란트의 MBL을 최소화하고 임플란트 안정성을 확보하기 위해서 임플란트 보철물의 EA와 임플란트-지대주 연결 유형을 세심하게 고려해야 할 것이다.

상악 완전 무치악 환자에서 CM LOC® Pekkton® attachment를 이용한 임플란트 유지 피개의치 수복 증례 (Implant-retained overdenture with CM LOC® Pekkton® in maxillary edentulous patient)

  • 홍문기;신수연
    • 구강회복응용과학지
    • /
    • 제33권4호
    • /
    • pp.321-328
    • /
    • 2017
  • 무치악은 총의치나 임플란트 보철물로 수복이 가능하며 임플란트를 이용한 피개의치는 총의치보다 유지와 안정이 우수하고, 임플란트 고정성 보철물에 비해 저렴하고 심미적이다. CM $LOC^{(R)}$ $Pekkton^{(R)}$ 어태치먼트는 여자부가 poly-ether-ketone-ketone으로 마모저항성이 뛰어나다. 한편, SR Ivocap system은 가압주사성형법으로 의치의 수직고경 변화가 적고 강도가 우수하다. 본 증례에서 상악은 4개의 임플란트 식립 후 CM $LOC^{(R)}$ $Pekkton^{(R)}$ 어태치먼트와 SR Ivocap system을 이용한 임플란트 유지 피개의치를, 하악은 가철성 국소의치를 제작하였고 심미적 및 기능적으로 만족스러운 결과를 얻었기에 이를 보고하는 바이다.