• 제목/요약/키워드: Prostheses

검색결과 703건 처리시간 0.024초

대전 시민의 심미보철에 대한 만족도 및 인식도 연구 (A study on satisfaction with and recognition of aesthetic dental prostheses among citizens in Daejeon)

  • 지민경;신민우
    • 한국치위생학회지
    • /
    • 제8권1호
    • /
    • pp.147-161
    • /
    • 2008
  • The present writer conducted this study in order to seek desirable directions to enhance right recognition of aesthetic dental prostheses and maximize the aesthetic effect of dental prostheses, by investigating satisfaction with and recognition of aesthetic prostheses among citizens in Daejeon, the writer carried out a self-administered survey with a questionnaire, reaching the following conclusions. 1. It was revealed that 54.4% of them had previous knowledge of aesthetic prostheses while 45.6% had not, and among people with the knowledge, 20.8% acquired it from the dental clinic interested. 2. It was revealed that 58.9% were not satisfied with their front teeth, and among them 24.8% were discontented with their teeth color most. 3. In general characteristics according to whether or not they have previous knowledge aesthetic prosthesis, among people with the knowledge 58.8% were female while 41.2% were male, showing a statistically significant difference (pM0.002). 4. In terms of levels of satisfaction with aesthetic dental prostheses by age, in the case of dissatisfaction people over 30 were most with 14.1%. 5. In terms of levels of recognition of aesthetic prostheses according to whether or not they have previous knowledge of those, among people with the knowledge, 55.8% reported that aesthetic prostheses are necessary (pM0.000). 6. In terms of levels of recognition of aesthetic prostheses according to whether or not they have aesthetic prostheses, among people with knowledge of the kinds of aesthetic prostheses, 87.2%(pM0.000). It was thought that in order to create accurate recognition of and enhance satisfaction with aesthetic dental prostheses, dental care expenses should be adjusted reasonably and also dentists should perform public relations actively with accurate information and provide related education.

  • PDF

골유착성 임플랜트 지지 고정성 보철물과 자연치의 최대교합력 비교 (COMPARISON OF MAXIMUM OCCLUSAL FORCES ON OSSEOINTEGRATED IMPLANT SUPPORTED FIXED PROSTHESES AND NATURAL TEETH)

  • 권영숙;황선홍;한동후
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.498-510
    • /
    • 2005
  • Purpose: The purpose of this study was to compare the maximum occlusal force implant prostheses to natural teeth. Material and Method: Fifty nine patients treated either with $Br{\aa}anemark$ implants and ITI implants during the recent ten years were involved in this study. The maximum occlusal force were measured with unilateral bite force recorder and dental prescale system. Results: 1. The maximum occlusal forces of the implant prostheses and natural teeth were not significantly different where measured with unilateral bite force recorder and dental prescale system. 2. The maximum occlusal forces were not significantly different between $Br{\aa}nemark$ implant and ITI implant prostheses. 3. The maximum occlusal forces of the implant prostheses had lower when compared with natural teeth during 1-6 months functional periods when measured with the unilareral bite force recorder(P<0.05) and 1-12 months functional periods when measured with the dental prescale system(P<0.05). After these periods there was not statistical significant difference between the implant prostheses and natural teeth. 4. The maximum occlusal forces of the wide diameter implant prostheses were higher than the maximum occlusal forces of the regular diameter implant prostheses when measured with dental prescale system(P<0.05), but there was no significant difference between the wide diameter and the regular diameter implant prostheses when measured with unilateral bite force recorder. 5. The maximum occlusal forces of the single implant prostheses were not significantly different with the splinting implants prostheses. 6. The maximum occlusal forces of the implant prostheses were not significantly different by age and sex. 7. There was significantly different between maximum occlusal forces measured with unilateral bite force recorder and dental prescale system(P<0.0001) but there was positive correlation(r=0.52. P<0.05). Conclusion: The maximum occlusal forces of the implant prostheses were not significantly different to natural teeth during clenching and unilateral maximum biting.

비접촉식 구강외 스캐너와 비디오방식 구강내 스캐너를 이용하여 제작된 보철물의 내면정확도 비교 (Comparison of the Internal Fitness of Prostheses Fabricated with Non-Contact Extra-Oral Scanner and Intra-Oral Video Scanner)

  • 박진영;김지환;정일도;이광영;김원수
    • 대한치과기공학회지
    • /
    • 제41권4호
    • /
    • pp.263-269
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the internal fitness of prostheses fabricated with non-contact extra-oral scanner and those fabricated with intra-oral video scanner, with a comparative accuracy analyses of their precision and trueness. Methods: A polymethyl methacrylate (PMMA) model was fabricated by replicating a master model. The prostheses in the first group were fabricated based on the PMMA model with an intra-oral video scanner (IVS group). Following the fabrication of work models with Type IV Stone that were based on the PMMA model, the prostheses in the second group were fabricated with a non-contact extra-oral scanner (ENB group). The precision and trueness of the prostheses were calculated from comparisons of the three-dimensional images of the internal surfaces of the prostheses and those of the master model. Kruskal-Wallis tests were used to determine the statistical significance, with the level of type 1 error set at 0.05. Results: Trueness (P < 0.009) and precision (P < 0.001) did not differ significantly between the ENB and IVS groups. The IVS group exhibited lower trueness values and larger precision values than the ENB group. Conclusion: Although no significant differences were found in the internal fitness of the prostheses that were fabricated by the two different scanners, the intraoral video scanner-fabricated prostheses had better trueness, whereas the non-contact extra-oral scanner-fabricated prostheses had better precision.

한국 노인의 치과보철 상태에 따른 건강 관련 삶의 질에 관한 연구 (A study of the EQ-5D index according to the dental prostheses status of the elderly in Korea)

  • 황홍구;이종화
    • 대한치과기공학회지
    • /
    • 제43권1호
    • /
    • pp.19-28
    • /
    • 2021
  • Purpose: This study aimed to obtain basic data on oral health improvement by investigating the EQ-5D index according to the oral prosthesis status of elderly persons aged 65 years or older in Korea using the Seventh Korea National Health and Nutrition Examination Survey. Methods: In this study, 3,426 elderly persons aged 65 years or older were included to analyze the relationship between the dental prostheses status and EQ-5D index in the collected data. Results: Compared to the "complete denture" in oral prosthesis, EQ in case of no dental prostheses or fixed dental prostheses is comparable to removable prosthetics such as "no dental prostheses," "one fixed bridge," and "two or more fixed bridges." Removable partial denture and complete denture required for the maxillary and mandibular EQ-5D index were significantly higher in "not necessary" than in "complete denture necessary" in all the elderly persons. Conclusion: The condition of the dental prosthesis and the need for a removable partial denture and complete denture for the elderly's EQ-5D index were confirmed, and it was found that the fixed dental prostheses were more effective than the removable dental prostheses. Therefore, oral health education programs for the elderly should be developed to promote dental function and oral health maintenance.

'The design concepts of Kudo Total Elbow Prosthesis, and some of the technical considerations for its use'

  • Kudo Hiroshi
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 2002년도 아시아견관절학술대회
    • /
    • pp.177-179
    • /
    • 2002
  • Total elbow prostheses which are now available in clinical use can generally be classified into two major categories ; one bing linked prostheses, another being unlinked prostheses. Of those two categories I am dealing here only with the problems of the unlinked type prosthesis, particularly with those of non-constrained, surface-replacement prostheses. Furthermore, my presentations this time may have to be narrowed down only to the topics regrading the particular features and some of the technical problems with Kudo Elbow Prosthesis, due to the time limit assigned for this presentation.

  • PDF

고정성 보철물과 연관된 합병증과 실패에 관한 조사 (Complication and Failure Analysis of Fixed Restorations)

  • 윤미정
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.149-159
    • /
    • 2011
  • 고정성 보철물의 장기적 예후를 보장하고자 하는 많은 노력에도 불구하고, 아직도 임상에서는 부적절한 제작 및 유지 관리로 인한 다양한 고정성 보철물의 합병증이 관찰되고 있다. 이에 본 연구에서는 고정성 보철물의 임상적 상태를 조사하여 보철 진료의 임상적 참고 자료와 연구의 기초 자료로 도움이 되고자하였다. 2009년 1월에서 2009년 12월까지 12개월간 부산대학교병원 치과 보철과에 내원한 환자 중 기존의 고정성 보철물을 철거하고 치료를 시행한 환자를 대상으로 고정성 보철물과 지대치에 연관된 임상적 상태를 조사 평가하여 다음과 같은 결과를 얻었다. 1. 전체 고정성 보철물의 추정 수명은 10.0년이었고, 평균 장착 기간은 $10.3{\pm}5.5$년이었다. 2. 악골에 따른 수명의 차이는 없었으나 (P>.05), 전후방 위치에서는 전치부 또는 구치부에 비해 전치부와 구치부를 포함하는 보철물의 수명이 가장 길었다 (P<.05). 3. 고정성 보철물의 재료별 수명은 금속관이 가장 길었고 (P<.05), 다른 재료들 간에는 유의한 차이가 없었다 (P>.05). 4. 고정성 보철물의 크기는 보철물 수명에 영향을 미치지 않았다 (P>.05). 5. 대합치 조건별 고정성 보철물의 수명은 자연치와 고정성 보철물, 가철성 국소 의치, 총의치 순으로 길었다 (P<.05). 6. 고정성 보철물의 생물학적 합병증은 치주 질환 (37.5%), 치아 우식증 (19.0%), 그리고 치수 질환 (10.8%) 순이었고, 기계적 문제점은 변연 결함 (18.4%), 보철물 파절(4.2%), 유지력 상실 (3.9%), 치아 파절 (3.6%), 그리고 식편 압입 (2.6%) 순이었다. 보철물을 철거한 후 치대치의 33.1%는 재수복이 불가능한 상태였다.

치과 임플랜트 보철 장착자의 구강 감각 기능에 관한 연구 (A STUDY ON ORAL SENSORY FUNCTION IN THE IMPLANT-SUPPORTED PROSTHESES WEARERS)

  • 장경수;김영수
    • 대한치과보철학회지
    • /
    • 제29권1호
    • /
    • pp.215-232
    • /
    • 1991
  • In this study, oral sensory function in the osseointegrated root form implant-supported prostheses wearers was estimated by measuring occlusal tactile perception threshold of thickness and sensibility threshold against lateral static loading, and comparing with normal dentition subjects and complete denture wearers group. Osseointegrated root form implants seemed to be restored in the sensation to some extent, and so, dental implants restored edentulous patients in a wide meaning. Conclusions were summarized as following. 1. Occlusal tactile perception threshold of thickness was highest in complete denture wearers group, following by implant-supported prostheses wearers group, normal dentition subjects group. 2. In the implant-supported prostheses wearers group, occlusal tactile perception threshold of opposing artificial teeth case was higher than of opposing natural or opposing implantsupported teeth case. 3. Sensibility threshold against lateral loading of complete denture wearers and implantsupported prostheses wearers group was higher than that of normal dentition subject group. 4. In the implant-supported prostheses group, sensibility threshold against lateral loading was not significantly different between upper and lower jaws. 5. In occlusal tactile perception threshold of thickness and sensibility threshold against lateral loading test, there was no regularity among values of each tooth, and no significant difference between anterior and posterior teeth as well.

  • PDF

임플란트-지지 고정성 보철물의 임상적 상태에 대한 평가 (Clinical Evaluation of Implant-Supported Fixed Prostheses)

  • 박찬용;윤미정;허중보;정창모;전영찬
    • 구강회복응용과학지
    • /
    • 제29권4호
    • /
    • pp.317-326
    • /
    • 2013
  • 임플란트-지지 고정성 보철물의 누적 생존율을 구하고, 생존율에 영향을 미치는 요소와 요소 간 상관관계를 평가하여, 임플란트-지지 고정성 보철물의 예후를 예측하는 데 도움을 주고자 한다. 2000년에서 2007년까지 부산대학교 치과병원에 내원한 환자 중 임플란트를 식립하고 임플란트-지지 고정성 보철물을 제작한 환자를 대상으로 임플란트-지지 고정성 보철물과 관련한 종합적인 임상적 상태를 조사 평가하여 다음과 같은 결과를 얻었다. 1. 전체 임플란트-지지 고정성 보철물의 추정 수명은 11.7년이었고, 고정성 보철물에 문제가 발생되는 추정 시점은 9.5년이었다. 2. 나이와 성별에 따른 수명의 차이는 나타나지 않았다(P>.05). 3. 치아 발거 원인은 임플란트-지지 고정성 보철물의 수명에 영향을 미쳤다(P<.05). 치아 우식증의 경우 고정성 보철물의 수명은 10.0년, 치주 질환의 경우 9.0년이었다. 4. 악골에 따른 수명의 차이는 나타나지 않았으나(P>.05), 전후방 위치에서는 소구치부 보철물의 수명이 11.0년으로 수명이 길었고, 대구치 부위 보철물의 수명이 8.8년으로 짧았다(P<.05). 5. 임플란트-지지 고정성 보철물의 크기는 보철물의 수명에 영향을 미치지 않았다(P>.05). 6. 대합치 조건별 임플란트-지지 고정성 보철물의 수명은 차이가 없었다(P>.05). 7. 임플란트-지지 고정성 보철물의 합병증은 식편 압입(40.5%), 도재 파절(25.8%), 나사 풀림(23.6%) 순이었다. 식편 압입은 임플란트 위치와 상관관계를 보였고, 나사와 관련된 문제는 임플란트 위치와 보철물 종류에 영향을 받았다(P>.05).

악안면 보철의 임상적 고찰;골내 매식술을 통한 보철적 회복에 관하여 (CLINICAL STUDY OF MAXILLOFACIAL PROSTHESES;OSSEOINTEGRATED IMPLANTS FOR MAXILLOFACIAL PROSTHESES)

  • 민승기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제23권5호
    • /
    • pp.406-414
    • /
    • 2001
  • 현재 악안면 보철 제작에 있어 재료로 실리콘이 제일 많이 사용되고 있으나 이 재료는 시간이 지남에 따라 점차 굳어져 가고 탄력성을 잃으며 원래의 색도 노랗게 변색되어 간다는 단점이 있다. 이러한 재료의 화학적 구성 단점 때문에 보철 생명력을 유지하기 위하여 환자들은 매 3년마다 새로운 보철물을 재 제작하여야 한다. 그렇다면 복잡했던 악안면 기공 과정을 다시 반복해야 하는 시간적, 물질적 손실을 감수해야 했다. 이러한 단점들을 보완하고 환자 피부색과 적합이 잘 되는 다양한 색의 실리콘 개발과 아울러 눈동자를 깜빡일 수 있는 인공 눈동자의 개발 등이 필요하며, 눈동자를 만드는데 사용되는 인공 수정체의 발전이 향후 악안면 보철 분야의 큰 과제라 할 수 있다.

  • PDF

부분무치악 환자에서 기능하중노출이 골유착성 임플란트 주위의 치조골 소실에 미치는 영향에 관한 방사선학적 연구 (RADIOGRAPHIC EVALUATION OF BONE CHANCE AROUND OSSEOINTEGRATED IMPLANTS IN PARTIALLY EDENTULOUS JAWS WITH FIXED TISSUE-INTEGRATED PROSTHESES)

  • 양순봉;한동후;양자호
    • 대한치과보철학회지
    • /
    • 제34권1호
    • /
    • pp.70-84
    • /
    • 1996
  • This paper reports marginal bone loss around osseointegrated implants after loading in partially edentulous patients in dental hospital, Yonsei University. Two types of implants($Br{\aa}nemark^{TM},\;IMZ^{TM}$) were used. Through the digital measurement on periapical radiograph around 37 implants in human subjects, marginal bone loss was observed for 24 months after delivery of prostheses. The results were as follows; 1. According to experimental periods marginal bone loss in total implants was 1.775 mm at 12 months, 1.921 mm at 24 months after delivery of prostheses(p<0.05). 2. Marginal bone loss in the $Br{\aa}nemark$ implants was 1.831 mm at 12 months, 1.833 mm at 24 months after delivery of prostheses(p<0.05). 3. Marginal bone loss in the IMZ implants was 1.578 mm at 12 months, 2.907 mm at 23 months after delivery of prostheses(p<0.05). 4. During the first year after loading, the IMZ implants showed less marginal bone loss than the $Br{\aa}nemark$ implants but, during the next the $Br{\aa}nemark$ implants showed less than the IMZ implants(p>0.05). These results indicate that marginal bone loss around osseointegrated implants occurs within the first 12 months after delivery of prostheses and stabilizes thereafter, so it is necessary to be careful of using dental implants for the first year after delivery of prostheses.

  • PDF