• Title/Summary/Keyword: Propriety

Search Result 659, Processing Time 0.026 seconds

Development of the Smart Concrete Appling Cross Stitch (크로스 스티치를 응용한 스마트 콘크리트의 개발)

  • Kim Ie-Sung;Kim Wha-Jung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.168-171
    • /
    • 2004
  • If a research trend present in and outside the country is often seen, the structure measurement method of having used PZT and the optical fiber (FBG) will be the actual condition which has accomplished the stock. In order to manage such cracks, time, efforts and expense are required. Such a method has many difficulties in application of a structure by the difficult problem of the measurement range, and the expensive sensor price. Progressive cracks were generated by fracture of glass pipe sensor. Moreover, the experiment which can detect damage propriety by external Light Emitting Diode by damaging a glass pipe by load change with the application of switch using strain gage of a glass pipe was conducted.

  • PDF

Load Characteristic Identification and Transient Stability Analysis Using Neural Network (신경회로망에 의한 부하식별과 과도안정도 해석)

  • Lee, Jong-Pil;Kim, Tae-Eung;Ji, Pyeong-Shik;Nam, Sang-Cheon;Lim, Jae-Yoon;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1127-1129
    • /
    • 1997
  • In this paper, we developed to artificial neural network for load characteristic identification of power system. We can acquire active power and reactive power of individual load depending on the variation of voltage and frequency from the experimentation of a dynamic characteristic of load. The data of the experimental results were be used in learning of ANN. A proposed ANN model is applied to analyze the transient stability. To demonstrate the propriety of the power system transient stability with load model using ANN, the simulation of the two-machine five-bus system is carried out.

  • PDF

A Study on Reduction Method of Electromagnetic Noise of PCB for Vehicle Cluster (자동차 클러스터용 PCB의 전자기 노이즈 저감 방안 연구)

  • Kim, Byeong-Woo;Hur, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1336-1341
    • /
    • 2009
  • In this paper, an EMI reduction effects using an EMC chamber is described and reduction methods is proposed. In the case of general electronic components a working frequency is low. But in this paper the vehicle cluster works 75MHz in the main clock frequency, becoming weak by noise because of being attached in TFT LCD. As the outer case installed in the vehicle is made up of plastic materials, the noise is radiated if not protecting noise in the PCB itself. Therefore, This paper will explain the theoretical basis and propriety with respect to the discussion and need about the guide for PCB design considering EMC, through the reduction of PCB noise.

Regional Grouping of the interconnected network system through Sequential Clustering (순차적 클러스터링을 이용한 지역별 그룹핑)

  • Kim, Hyun-Hong;Song, Hyoung-Yong;Kim, Jin-Ho;Park, Jong-Bae;Shin, Jung-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.252-254
    • /
    • 2007
  • This paper introduces the method of sequential clustering as a tool for the effective clustering of mass unit electrical systems. The interconnected network system retains information about the location of each line. With this information, this paper aims to carry out initial clustering through the transmission usage rate, compare the results of similarity measures for regional information with similarity measures for regional price, and introduce the technicalities of the clustering method. This transmission usage rate used power flow based on congestion costs and modified similarity measurements using the FCM algorithm. This paper also aims to prove the propriety of the proposed clustering method by comparing it with existing clustering methods that use the similarity measurement system. The proposed algorithm is demonstrated through the IEEE 39-bus RTS.

  • PDF

The Design of Lens for Power LEDs Spot Light (고출력 LED를 이용한 스포트라이트용 렌즈설계)

  • Shin, Kyung-Ho;Song, Sang-Bin;Yeo, In-Seon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.145-150
    • /
    • 2004
  • The LED lighting used spot-light illuminate the limited surface. So it is a key-point to condense wide emission angle of high power light emitting diodes (LEDs) to narrow that angle. In this paper, the secondary optics was designed by lens-makers formula for concentration rays of LED into specific region. So, it simulated the optics that designed by lens makers-formula in the optical design program, LightTools. And then, show the p propriety of lens design utilizing simulation result, luminous intensity, emission angle.

  • PDF

The Optimization Grounding Analysis for Soil Resistivity (대지저항률에 따른 최적화 접지 해석)

  • Jung, Yeon-Ha;Jang, Tae-Jun;Kwak, Hee-Ro;Roh, Young-Su;Shong, Kil-Mok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.241-245
    • /
    • 2004
  • The electric safety tends to be more important according to electric facilities's increase and its use in these days. This paper analyzes soil resistivity of two areas in the country using CDEGS(Current Distribution, Electromagnetic Interference, Grounding and Soil Structure, Canada). We designed rod and mesh grounding system and made a comparative study of ground resistance, GPR(Main Electrode Potential Rin), step voltage and touch voltage. Then we could analyz only the safety but also economical efficiency in elocution of grounding. As a result of simulation, ground resistance, GPR(Main Electrode Potential Rise), step voltage and touch voltage became higher in proportion to soil resistivity. Therefore we expect to estimate the propriety of grounding system design through accumulation and analysis of data in consideration of characteristics of soil.

  • PDF

Suppression of high frequency leakage current in PWM Inverter-Fed Induction Motor Drives using Active Common Mode Voltage Damper (능동형 커먼 모드 전압 감쇄기를 통한 유도 전동기의 고주파 누설전류 억제)

  • 홍순일
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.186-190
    • /
    • 2000
  • This paper propose a "Active common-mode voltage damper circuit" that capable of a suppression of a common-mode voltage produced in the PWM VSI. The four level half-bridge PWM inverter circuit and common-mode transformer are incorporated into the "Active common-mode voltage damper" the design method of which is presented Effect of "Active common-mode voltage damper" in this paper verifies a propriety and effectiveness in 2.2[kW] induction motor drive using IGBT inverter. Experimental results show that "common-mode voltage damper" makes contributions to reducing a high frequency leakage current and common-mode voltage.leakage current and common-mode voltage.

  • PDF

A Study on the Prediction of Performance due to Cycle Simulation Model in Spark Ignition Engine (SI 기관에 있어서 사이클 시뮬레이션에 의한 성능예측에 관한 연구)

  • 한영출;이원일
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.91-101
    • /
    • 1986
  • Relations of each factor affected by emissions and the prediction of performance have been analyzed numerically by cycle simulation in the Spark Ignition Engine. Through theoretical analysis and experiments, the results are obtained as below. The calculated results and the experimental ones are almost highly agreeable on cycle simulation model, exhaust gas analysis and efficiency for processes in cylinder. Therefore this model is proved appropriate and can be useful for optimum design of Spark Ignition Engines on parametric studies. It is reaffirmed that the Wiebe's function is suitable for predicting Combustion Ration in Spark Ignition Engines. On parametric studies, it is found that optimum conditions whose density of emissions are lower and efficiency is maximum within propriety value are crankangle ATDC $15^\circ-20^\circ$, 2400 rpm. A/F=16 in this experiment.

  • PDF

Analysis of Characteristics in Low-shrinkage Cement Treated Base (저수축 시멘트 안정처리 기층의 특성분석)

  • Lee, Seung-Woo;Jeon, Beom-Jun;Kim, Jong-Won
    • International Journal of Highway Engineering
    • /
    • v.6 no.2 s.20
    • /
    • pp.61-70
    • /
    • 2004
  • Cement treated Soil has superior characteristics as pavement-base including strength, curability, hardness, freezing resistance. However drying shrinkage of Cement treated base has been indicated as disadvantage, since reflection crack of surface layer is induced from drying shrinkage of cement treated base. This study propriety about low-shrinkage cement treated base that can control shrinkage of cement and control reflection crack at asphalt overlay & concrete slab.

  • PDF

Goodness of Link Tests for Binary Response Data

  • Yeo, In-Kwon
    • Communications for Statistical Applications and Methods
    • /
    • v.8 no.2
    • /
    • pp.357-366
    • /
    • 2001
  • The present paper develops a method to check the propriety of link functions for binary data. In order to parameterize a certain type of goodness of the link, a family of link functions indexed by a shape parameter is proposed. I first investigate the maximum likelihood estimation of the shape parameter as well as regression parameters and then derive their large sample behaviors of the estimators. A score test is considered to evaluate the goodness of the current link function. For illustration, I employ two families of power transformations, the modulus transformation by John and Draper (1980) and the extended power transformation by Yeo and Johnson (2000), which are appropriate to detect symmetric and asymmetric inadequacy of the selected link function. respectively.

  • PDF