Circulating Current Control of MMC-HVDC System based on Vector PI Controllers under Unbalanced Grid Voltage Conditions (불평형 전압 조건에서 Vector PI 제어기를 적용한 MMC-HVDC 시스템의 순환전류 제어)

  • Lee, June-Sun;Kim, Si-Hwan;Kim, Rae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.7-8
    • /
    • 2016
  • 본 논문에서는 모듈형 멀티레벨 컨버터 (Modular Multilevel Converter ; MMC) 고압 직류 송전 (High Voltage Direct Current ; HVDC) 시스템의 순환전류 성분을 제어하기 위해 VPI (Vector Proportional Integral) 제어기를 적용한 순환전류 제어 기법을 제안하였다. 제안한 방식은 기존의 준공진 (Quasi-Resonant) 제어기를 적용한 방식과 비교하여 계통 주파수 변동에 강인하고 넓은 공진 대역폭 선정이 용이한 장점을 갖는다. 제안한 순환전류 제어기의 성능은 기존의 준공진 제어기를 적용한 기법과 계통 전압 단상지락 및 계통 주파수 변동 상황에서 시뮬레이션을 통하여 비교 검증하였다.

  • PDF

Analysis of Current Controllers of Grid-connected PCS for Distributed Resource (분산전원용 계통연계형 PCS의 전류제어기 해석)

  • Han, Sang Hyup;Jo, Teak-Hyun;Park, Jong Hyung;Kim, Heung-Geun;Chun, Tae-Won;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.11-12
    • /
    • 2010
  • 본 논문은 LCL필터를 이용한 분산전원용 계통연계형 PCS의 전류제어기를 비교 분석하였다.주요 비교대상은 PI(Proporional-intergral)제어,PR(Proportional-Resonant),제어기, DeadBeat (DB)제어기 등의 선형 제어기 이며, 각 제어기의 과도상태 응답특성과 정상상태 응답특성을 시뮬레이션으로 비교하였다. 또한 DSP의 특성에 의한 1 주기 지연, 리액턴스와 저항 변화 등에 강인한 DB제어기 관하여 논의 하겠다.

  • PDF

Seamless Mode Transfer of Indirect Current Controlled Parallel Grid-Connected Inverters (간접전류제어방식 병렬형 계통연계 인버터의 무순단 모드절환)

  • Song, Injong;Choi, Junsoo;Lim, Kyungbae;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.5
    • /
    • pp.334-341
    • /
    • 2019
  • This study proposes the control strategy for the seamless mode transfer of indirect current controlled parallel grid-connected inverters. Under the abnormal grid condition, the grid-connected inverter can convert the operation mode from grid-connected to stand-alone mode to supply power to the local load. For a seamless mode transfer, the time delay problems caused by the accumulated control variable error must be solved, and the indirect current control method has been applied as one of the solutions. In this study, the design of control parameters for the proportional-resonant-based triple-loop indirect current controller and the control strategy for the seamless mode transfer of parallel grid-connected inverters are described and analyzed. The validity of the proposed mode transfer method is verified by the PSiM simulation results.

Correlation between Storm Waves and Far-Infra-Gravity Waves Observed in kkye Harbor (옥계항에서 관측된 폭풍파와 저중력파의 상호관계)

  • 정원무;채장원;박우선;이광수;서경덕
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.3
    • /
    • pp.209-229
    • /
    • 2001
  • Simultaneous field measurements of short-period and long-period waves were made at five stations inside or outside Okkye Harbor, which is located in the east coast of Korea. Based on the measured data, spacial and temporal variations of the long-period wave energy were examined. Three smoothing methods were examined for the spectral estimates: fixed interval averaging method, incremental interval averaging method, and moving averaging method. It was shown that a proper smoothing method should be chosen depending on the period of first resonant mode and the length of data being used. By comparing the results obtained using the long-term data with those obtained using two-day data, we showed that it is necessary to analyze the data of calm seas and storm seas separately. The Helmholtz resonant period in Okkye Harbor was found to be about 9.6 minutes with its relative amplification ratio of 9 to 10, and local amplifications were apparent at the periods of 1.2 to 1.3 minutes and 0.7 minute. During calm seas, both at the harbor entrance and inside the harbor the energy of the waves of 9 minutes or longer period was larger than the infra-gravity wave energy by more than 100 times. However, during storm seas the energy level was very high all over the period band, and local amplification was larger than that during calm seas by more than 100 times, especially inside the harbor, Finally it was shown that the energies of the Helmholtz resonant mode and the infra-gravity waves of 1 to 2 minutes are proportional to the storm wave height.

  • PDF

Control and Analysis of an Integrated Bidirectional DC/AC and DC/DC Converters for Plug-In Hybrid Electric Vehicle Applications

  • Hegazy, Omar;Van Mierlo, Joeri;Lataire, Philippe
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.408-417
    • /
    • 2011
  • The plug-in hybrid electric vehicles (PHEVs) are specialized hybrid electric vehicles that have the potential to obtain enough energy for average daily commuting from batteries. The PHEV battery would be recharged from the power grid at home or at work and would thus allow for a reduction in the overall fuel consumption. This paper proposes an integrated power electronics interface for PHEVs, which consists of a novel Eight-Switch Inverter (ESI) and an interleaved DC/DC converter, in order to reduce the cost, the mass and the size of the power electronics unit (PEU) with high performance at any operating mode. In the proposed configuration, a novel Eight-Switch Inverter (ESI) is able to function as a bidirectional single-phase AC/DC battery charger/ vehicle to grid (V2G) and to transfer electrical energy between the DC-link (connected to the battery) and the electric traction system as DC/AC inverter. In addition, a bidirectional-interleaved DC/DC converter with dual-loop controller is proposed for interfacing the ESI to a low-voltage battery pack in order to minimize the ripple of the battery current and to improve the efficiency of the DC system with lower inductor size. To validate the performance of the proposed configuration, the indirect field-oriented control (IFOC) based on particle swarm optimization (PSO) is proposed to optimize the efficiency of the AC drive system in PHEVs. The maximum efficiency of the motor is obtained by the evaluation of optimal rotor flux at any operating point, where the PSO is applied to evaluate the optimal flux. Moreover, an improved AC/DC controller based Proportional-Resonant Control (PRC) is proposed in order to reduce the THD of the input current in charger/V2G modes. The proposed configuration is analyzed and its performance is validated using simulated results obtained in MATLAB/ SIMULINK. Furthermore, it is experimentally validated with results obtained from the prototypes that have been developed and built in the laboratory based on TMS320F2808 DSP.

Stationary Frame Current Control Evaluations for Three-Phase Grid-Connected Inverters with PVR-based Active Damped LCL Filters

  • Han, Yang;Shen, Pan;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.297-309
    • /
    • 2016
  • Grid-connected inverters (GCIs) with an LCL output filter have the ability of attenuating high-frequency (HF) switching ripples. However, by using only grid-current control, the system is prone to resonances if it is not properly damped, and the current distortion is amplified significantly under highly distorted grid conditions. This paper proposes a synchronous reference frame equivalent proportional-integral (SRF-EPI) controller in the αβ stationary frame using the parallel virtual resistance-based active damping (PVR-AD) strategy for grid-interfaced distributed generation (DG) systems to suppress LCL resonance. Although both a proportional-resonant (PR) controller in the αβ stationary frame and a PI controller in the dq synchronous frame achieve zero steady-state error, the amplitude- and phase-frequency characteristics differ greatly from each other except for the reference tracking at the fundamental frequency. Therefore, an accurate SRF-EPI controller in the αβ stationary frame is established to achieve precise tracking accuracy. Moreover, the robustness, the harmonic rejection capability, and the influence of the control delay are investigated by the Nyquist stability criterion when the PVR-based AD method is adopted. Furthermore, grid voltage feed-forward and multiple PR controllers are integrated into the current loop to mitigate the current distortion introduced by the grid background distortion. In addition, the parameters design guidelines are presented to show the effectiveness of the proposed strategy. Finally, simulation and experimental results are provided to validate the feasibility of the proposed control approach.

Adsorption of Aromatic Compounds on a QCM System Coated with Polymer Films (고분자 필름이 코팅된 QCM 시스템에 의한 방향족 화합물의 흡착)

  • Hwang, Min-Jin;Shim, Wang-Geun;Moon, Hee
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.233-239
    • /
    • 2013
  • A quartz crystal microbalance (QCM) system coated with poly (isobutylene), polystyrene, and poly (methyl methacrylate) has been prepared to measure the adsorption amounts of benzene, toluene, and p-xylene at very low pressures. The resonant frequency shift of the QCM system is proportional to the increase in pressure in all experiments. The Henry's constants for all adsorbates on the polymer films are obtained from experimental data and compared with the minimum adsorption potential energies between adsorbates and the polymer films. In general, there is an explicit correlation between adsorption amount and the minimum adsorption potential energy.

A DVR Control for Compensating Unbalanced Voltage Dips of a DFIG System using Zero Sequence Components

  • Thinh, Quach Ngoc;Ko, Ji-Han;Kim, Dong-Wan;Kim, Eel-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.62-68
    • /
    • 2013
  • The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generators based on doubly-fed induction generator (DFIG) that is operated under unbalanced voltage dip conditions. The compensating voltages of the DVR depend on the voltage dips and on the influence of the zero sequence component. The zero sequence component results in high insulation costs and asymmetry in terminal voltages. This paper proposes the use of a proportional-resonant controller in stationary reference frames for controlling zero sequence components in the DVR to protect the DFIG during unbalanced voltage dips. To enhance the proposed control method, a comparison is carried out between two cases: with and without using the control of a zero sequence component. Simulation results are presented to verify the effectiveness of the proposed control method by using the Psim simulation program.

Limit of equivalence ratio on mixing enhancement in rich flames. (과농 예혼합화염의 혼합촉진에 대한 당량비 한계)

  • Kim, Jin-Kook;Shin, Hyun-Dong
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.1
    • /
    • pp.51-55
    • /
    • 1996
  • An experimental investigation has been made with the objective of studying the limits of equivalence ratio on mixing enhancement in a tone excited jet flame. The jet is pulsed by means of a loudspeaker-driven cavity and rich flames(${\phi}>1.5$) are used. The excitation frequency is chosen for the resonant frequency identified as a pipe resonance due to acoustic excitation. Methane, propane and butane are used to examine the effect of mixture property on the limit of equivalence ratio. Mixing is always enhanced in a methane/air flame as the excitation intensity increases. Constant lower limits of equivalence ratio for mixing enhancement are present in cases of propane/air and butane/air flames irrespective of mean mixture velocities. The equivalence ratio limits are also found to be related to the flame instability ; the lower Le, the higher the limit of equivalence ratio. Under the equivalence ratio limits, cellular flames are generated as the excitation intensity increases. The amplitude of oscillating velocity for generating a cellular flame in the equivalence ratio limit is proportional to a mean mixture velocity irrespective of fuels.

  • PDF

A Study on Current Ripple Reduction Due to Offset Error and Dead-time Effect of Single-phase Grid-connected Inverters Based on PR Controller (비례공진 제어기를 이용한 단상 계통연계형 인버터의 데드타임 영향과 옵셋 오차로 인한 전류맥동 저감에 관한 연구)

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.201-208
    • /
    • 2015
  • The effects of dead-time and offset error, which cause output current distortion in single-phase grid-connected inverters are investigated this paper. Offset error is typically generated by measuring phase current, including the voltage unbalance of analog devices and non-ideal characteristics in current measurement paths. Dead-time inevitably occurs during generation of the gate signal for controlling power semiconductor switches. Hence, the performance of the grid-connected inverter is significantly degraded because of the current ripples. The current and voltage, including ripple components on the synchronous reference frame and stationary reference frame, are analyzed in detail. An algorithm, which has the proportional resonant controller, is also proposed to reduce current ripple components in the synchronous PI current regulator. As a result, computational complexity of the proposed algorithm is greatly simplified, and the magnitude of the current ripples is significantly decreased. The simulation and experimental results are presented to verify the usefulness of the proposed current ripple reduction algorithm.