• Title/Summary/Keyword: Propeller flap

Search Result 20, Processing Time 0.024 seconds

Perforator-Based Propeller Flap for Lower Extremity Reconstruction (천공지기저 프로펠러 피판술을 이용한 하지 재건)

  • Huh, Sung-Woo;Bae, Jae-Ho;Song, Joo-Hyoun;Lee, Joo-Yup
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.2
    • /
    • pp.111-117
    • /
    • 2012
  • Purpose: To report the clinical results of the perforated-based propeller flap for lower extremity soft tissue reconstruction. Materials and Methods: Between January 2010 and June 2012, a total of 16 defects in the lower extremities were covered with perforator-based propeller flaps. Retrospective data for location and size of the defect, flap dimension, pedicle artery, pedicle rotation, complications were obtained. Results: Peroneal artery-based perforator flap were used in eleven cases, posterior tibial artery-based perforator flap in two cases, anterior tibial artery-based perforator flap in one case and medial plantar artery-based perforator flap in two cases. The average size of the flaps was $63cm^2$. The marginal skin necrosis of the flaps as a complication was developed in two cases, one of which was covered with split-thickness skin graft. There were no functional deficits from the donor site. Conclusion: For the reconstruction of lower extremities, the perforator-based propeller flap could be a reasonable alternative as it is a simple, safe and versatile technique.

  • PDF

A propeller superficial transverse cervical artery perforator flap for defect coverage of the submental area: a case report

  • Choi, Jong Yun;Seo, Jeong Hwa;Cha, Won Jin;Seo, Bommie Florence;Jung, Sung-No
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.6
    • /
    • pp.341-344
    • /
    • 2021
  • Reconstruction of submental defects is a challenge that needs to be approached carefully, since many important anatomical structures are located in this small space. Both aesthetic and functional outcomes should be considered during reconstruction. In this report, we describe a case where a superficial branch of the transverse cervical artery (STCA) perforator propeller flap was applied for coverage of the submental area. An 85-year-old woman presented with a 3-cm ovoid mass on her submental area. We covered the large submental defect with a STCA rotational flap in a 180° propeller pattern. The flap survived well without any complications at 1 year of followup. A STCA propeller flap is a useful surgical option in reconstruction for defect coverage of the submental area.

How to Transform a Perforator Propeller Flap into a Keystone Flap in Case of Unsatisfying Perforator Vessel Local Perforator Flap Coverage in Limbs

  • Elena Ciucur;Hadj Boukhenouna;Benjamin Guena;I. Garrido-Stowhas;Christian Herlin;Benoit Chaput
    • Archives of Plastic Surgery
    • /
    • v.50 no.2
    • /
    • pp.194-199
    • /
    • 2023
  • Moderate soft-tissue defects need stable coverage, ideally with tissue of similar characteristics and low donor site morbidity. We propose a simple technique for the coverage of moderate skin defects in the limbs. It allows intraoperative transformation of a propeller perforator flap (PPF) into a keystone design perforator flap (KDPF) in cases of unsatisfying perforator vessel or in cases of unpredictable intraoperative events. Between March 2013 and July 2019, nine patients with moderate soft-tissue defects (mean defect size 4.5 × 7.6 cm) in the limbs (two on the upper limbs and seven on the lower limbs) were covered using this technique. We performed four PPFs and five KDPFs. The mean follow-up was 5 months. There was one complication, partial distal tip necrosis in a PPF located in the leg, which healed by secondary intention within 3 weeks. The donor site was closed directly in all cases. No functional impairments were noted regardless of the perforator flap utilized. This technique enables us to employ flexible surgical strategies and allows us to make adjustments based on the patient's vascular anatomy.

Thoracodorsal artery flaps for breast reconstruction-the variants and its approach

  • Thomsen, Jorn Bo;Rindom, Mikkel Borsen;Rancati, Alberto;Angrigiani, Claudio
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.15-25
    • /
    • 2021
  • Thoracodorsal artery (TDA) flaps, ranging from the vascular-pedicled thoracodorsal artery perforator (TDAP) flap, the propeller TDAP flap, and the muscle-sparing latissimus dorsi (MSLD) flap to the conventional latissimus dorsi (LD) flap and the extended LD flap, can all be used for breast reconstruction. The aim of this paper and review is to share our experiences and recommendations for procedure selection when applying TDA-based flaps for breast reconstruction. We describe the different surgical techniques and our thoughts and experience regarding indications and selection between these procedures for individual patients who opt for breast reconstruction. We have performed 574 TDA flaps in 491 patients: 60 extended LD flaps, 122 conventional LD flaps, two MSLD flaps, 233 propeller TDAP flaps, 122 TDAP flaps, and 35 free contralateral TDAP flaps for stacked TDAP breast reconstruction. All the TDA flaps are important flaps for reconstruction of the breast. The LD flap is still an option, although we prefer flaps without muscle when possible. The vascular-pedicled TDAP flap is an option for experienced surgeons, and the propeller TDAP flap can be used in most reconstructive cases of the breast, although a secondary procedure is often necessary for correction of the pedicle bulk. The extended LD flap is an option for women with a substantial body mass index, although it is associated with the highest morbidity of all the TDA flaps. The MSLD flap can be used if the perforators are small or if dissection of the perforators is assessed to be hazardous.

Peroneal Artery Perforator-Based Propeller Flaps for Reconstruction of Soft Tissue Defect around the Ankle Joint: A Report of Four Cases (비골 동맥 천공지 기저 프로펠러 피판술을 이용한 족관절 주위 연부조직 결손의 재건술: 4예 보고)

  • Cho, Byung-Ki;Park, Ji-Kang;Park, Kyoung-Jin;Chong, Suri
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.4
    • /
    • pp.222-226
    • /
    • 2014
  • Four patients with soft tissue defects around the ankle joint were covered with peroneal artery perforator-based propeller flaps. Using color Doppler sonography, the flap was designed by considering the location of the perforator and soft tissue defects. The procedure was then performed by rotating the flap by $180^{\circ}$. Additional skin graft was required in a patient due to partial necrosis, and delayed wound repair was performed in another patient with poor blood circulation at the distal part of the flap. The remaining patients did not have any complications and results were considered excellent. Good outcomes were eventually obtained for all patients.

Role of the Gastrocnemius Musculocutaneous with a Propeller Style Skin Flap in Knee Region Reconstruction: Indications and Pitfalls

  • Gianluca Sapino;Rik Osinga;Michele Maruccia;Martino Guiotto;Martin Clauss;Olivier Borens;David Guillier;Pietro Giovanni di Summa
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.593-600
    • /
    • 2023
  • Background Soft tissue reconstruction around the knee area is still an open question, particularly in persistent infections and multiple reoperations scenario. Flap coverage should guarantee jointmobility and protection, even when foreign materials are implanted. The chimeric harvesting of the musculocutaneous gastrocnemius flap, based on the sural artery perforators, can extend its applicability in soft tissue reconstruction of the upper leg, overcoming the drawbacks of the alternative pedicled flaps. Methods A multicenter retrospective study was conducted enrolling patients who underwent to a pedicled, chimeric gastrocnemius musculocutaneous-medial sural artery perforator (GM-MSAP) or lateral sural artery perforator (GM-LSAP) flap for knee coverage in total knee arthroplasty (TKA) recurrent infections and oncological or traumatic defects of the upper leg from 2018 to 2021. Outcomes evaluated were the successful soft tissue reconstruction and flap complications. Surgical timing, reconstruction planning, technique, and rehabilitation protocols were discussed. Results Twenty-one patients were included in the study. Nineteen GM-MSAPs and 2 GM-LSAPs were performed (soft tissue reconstruction in infected TKA [12], in infected hardware [4], and in oncological patients [5]). Donor site was closed primarily in 9 cases, whereas a skin graft was required in 12. Flap wound dehiscence (1), distal flap necrosis (1), distal necrosis of the skin paddle (1), and donor site infection (1) were the encountered complications. Flap reraise associated to implant exchange or extensive debridement was successful without requiring any further flap surgery. Conclusion The propeller-perforator GM-MSAP offers qualitative defect coverage and easiness of multiple flap reraise due to skin availability and its laxity.

NUMERICAL STUDY OF PROPELLER AND HIGH LIFT DEVICE AERODYNAMIC INTERFERENCES (프로펠러와 고양력 장치와의 공력간섭에 대한 수치해석 연구)

  • Park, Y.M.;Kim, C.W.;Chung, J.D.;Lee, H.C.
    • Journal of computational fluids engineering
    • /
    • v.16 no.4
    • /
    • pp.47-54
    • /
    • 2011
  • A rotating propeller of turboprop aircraft gives much effect on the aerodynamic characteristics of wing such as lift, moment and stall. Specially propeller effect on the wing surface is much more dominant when aircrafts are in landing or take-off conditions. In the present paper, three dimensional Navier-Stokes simulations for the interaction of propeller and wing were carried out for medium sized turboprop aircraft. For rotating propeller, unsteady sliding mesh method was used to simulate a relative motion between moving and static bodies. For the power effect analysis in landing and take off configurations, double slotted flap was also considered and the aerodynamic characteristics were investigated. It was shown that the propeller slipstream enhanced the lift slope including maximum lift by eliminating local flow separation region and this enhancement was more dominant with high lift device.

Numerical Simulation of Propeller Slipstream Effect on Wing Aerodynamic Characteristics (프로펠러 후류 효과로 인한 날개의 공력 특성 수치해석)

  • Park, Y.M.;Kim, C.W.;Chung, J.D.;Lee, H.C.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.202-205
    • /
    • 2011
  • A rotating propeller of turboprop aircraft gives much effect on the aerodynamic characteristics of wing such as lift, moment and stall. Specially, a rotating propeller changes the lift and moment characteristics when aircrafts are in landing or take-off condition. In the present paper, 3-dimensional Navier-Stokes simulations for the interaction of propeller and wing were carried out. For rotating propeller, unsteady sliding mesh method was used to simulate a relative motion. For the power effect analysis in landing and take off configurations, double slotted flap was also considered and the aerodynamic characteristics were investigated. It was shown that the propeller slipstream enhanced the lift slope including maximum lift and this enhancement was more dominant with high lift device.

  • PDF

The flip-flap puzzle flap: Another recycling option

  • Gandolfi, Silvia;Carloni, Raphael;Gilleron, Matthieu;Bonmarchand, Albane;Auquit-Auckbur, Isabelle
    • Archives of Plastic Surgery
    • /
    • v.46 no.2
    • /
    • pp.176-180
    • /
    • 2019
  • Post-traumatic soft tissue defects sometimes require sequential flap coverage to achieve complete healing. In the era of propeller flaps, which were developed to reduce donor site morbidity, Feng et al. introduced the concept of the free-style puzzle flap, in which a previously harvested flap becomes its own donor site by recycling the perforator. However, when a perforator cannot be found with a Doppler device, we suggest performing a new type of flap, the flip-flap puzzle flap, which combines two concepts: the free-style puzzle flap and the flip-flap flap described by Voche et al. in the 1990s. We present the cases of three patients who achieved complete healing through this procedure.

The Keystone Flap in Greater Trochanter Pressure Sore

  • Byun, Il Hwan;Kwon, Soon Sung;Chung, Seum;Baek, Woo Yeol
    • Archives of Reconstructive Microsurgery
    • /
    • v.25 no.2
    • /
    • pp.72-74
    • /
    • 2016
  • The keystone flap is a fascia-based island flap with two conjoined V-Y flaps. Here, we report a case of successful treatment of a trochanter pressure sore patient with the traditional keystone flap. A 50-year-old male patient visited our department with a $3{\times}5cm$ pressure sore (grade III) to the left of the greater trochanter that was covered with eschar. Debridement was done and the defect size increased to $5{\times}8cm$ in an elliptical shape. Doppler ultrasound was then used to locate the inferior gluteal artery perforator near the wound. The keystone flap was designed to the medial side. The perforator based keystone island flap covered the defect without resistance. The site remained clean, and no dehiscence, infection, hematoma, or seroma developed. In general, greater trochanter pressure sores are covered with a perforator based propeller flap or fascia lata flap. However, these flaps have the risk of pedicle kinking and require a large operation site. For the first time, we successfully applied the keystone flap to treat a greater trochanter pressure sore patient. Our design was also favorable with the relaxation skin tension lines. We conclude that the keystone flap including a perforator is a reliable option to reconstruct trochanteric pressure sores.