• Title/Summary/Keyword: Proof construction

Search Result 180, Processing Time 0.024 seconds

A Study on the Proof Education in the Middle School Geometry - Focused on the Theory of van Hiele and Freudenthal - (중학교 기하의 증명 지도에 관한 소고 - van Hiele와 Freudenthal의 이론을 중심으로 -)

  • 나귀수
    • Journal of Educational Research in Mathematics
    • /
    • v.8 no.1
    • /
    • pp.291-298
    • /
    • 1998
  • This study deals with the problem of proof education in the middle school geometry bby examining van Hiele#s geometric thought level theory and Freudenthal#s mathematization teaching theory. The implications that have been revealed by examining the theory of van Hie이 and Freudenthal are as follows. First of all, the proof education at present that follows the order of #definition-theorem-proof#should be reconsidered. This order of proof-teaching may have the danger that fix the proof education poorly and formally by imposing the ready-made mathematics as the mere record of proof on students rather than suggesting the proof as the real thought activity. Hence we should encourage students in reinventing #proving#as the means of organization and mathematization. Second, proof-learning can not start by introducing the term of proof only. We should recognize proof-learning as a gradual process which forms with understanding the meaning of proof on the basic of the various activities, such as observation of geometric figures, analysis of the properties of geometric figures and construction of the relationship among those properties. Moreover students should be given this natural ground of proof.

  • PDF

Study on Suggestion of Smoke-proof System Using a Restroom for a Refuge Space (화장실 이용 피난공간의 방연시스템 제안 및 실규모 실험)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.61-66
    • /
    • 2012
  • In restroom on high-rise building, exhaust system comprising the blower and duct is installed to discharge the odor and the water is suppled. Thus the restroom with fire and flame protection system may be used as refuge area in a fire situation. The study presents the smoke-proof system which operates such that the exhaust system to discharge the odor is converted to air supply system and appropriate pressure difference between the restroom and the accommodation is maintained. Also real-scale test facilities of smoke-proof system for refuge space using a restroom are installed on 5-story smoke control test building and experiments for evaluating the operational performance of smoke-proof system are carried out.

Constructional Properties and Evaluation Methods of the Non-Incendive Type of Explosion-Proof Electrical Apparatus (비점화(非點火)(Non-Incendive)형(型) 방폭(防爆) 전기기기(電氣機器)의 구조특성(構造特性) 및 평가방법(評價方法))

  • Choi, Sang-Won;Lee, Gwan-Hyung;Moon, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.110-113
    • /
    • 1994
  • In the hazardous areas where explosive substances in the form of gases, vapor or mists exist, electrical apparatus and installations must be of explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, six types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, and special types. If electrical apparatus are made of explosion-proof construction in a way other than five above-mentioned types, and their performance is tested and approved by the reponsible authorities, they may be categorized as special type apparatus. In this paper, we introduced a special type of explosion-proof electrical apparatus, called non-incendive type, and presented its constructional requirements. We also investigated evaluation methods of non-incendive type apparatus to assure the explosion-proof performance, and proposed a new classification method of hazardous areas using probabilistic concept.

  • PDF

A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Crack Repairing Material using in Wet Environment Structure (습윤 환경 구조물에 적용하는 누수균열 보수용 방수씰의 성능평가 방법에 관한 연구)

  • 강효진;우영제;강호경;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.43-48
    • /
    • 2002
  • Since the basement building like the communication hole and etc. is built under the ground where it is pressed by the water, the leakage happens due to the dried-shrinking crack, the sinking crack, the creation of the work-joint of the building and etc. caused by the character of the material and construction way of the reinforced concrete building. Especially, a lot of repair for the leakage cannot help but being taken in temporary way without any noticeable countermeasure. Therefore, this kind of repair is socially criticized many times that this is defective construction even if this costs a lot. The fundamental reason of the above mentioned symptoms can be found in the creation of the work-joint caused by the character of the concrete building, the limitation of the physical performance of the existing water-proof and repair material, the limitation of the construction, the limitation of the physical sustaining performance of the concrete building, the limitation(heat-injury, deterioration) of the constancy of the durability caused by aging and etc. Therefore, in this study, we would like to present the better understanding on the water-proof seal relating to the application at the spot and its test evaluation related data since the necessity of the establishment of the quality control standard and the performance testing way on the relevant water-proof seal is rising a lot to regulate the water-proof technology and the leakage repair technology in accordance with the growth of the demand on the facility.

  • PDF

A Research on the Manufacture of Eco-Friendly Weed-Proof Mortar using Industrial Byproducts (산업부산물(産業副産物)을 혼입(混入)한 친환경성(親環境性) 방초(防草) 모르타르의 제조(製造)에 관(關)한 기초적(基礎的) 연구(硏究))

  • Kim, Nam Wook;Ko, Young Zoo
    • Resources Recycling
    • /
    • v.21 no.6
    • /
    • pp.23-31
    • /
    • 2012
  • Removal work about weeds that grow naturally on road and industrial complex is attaining ordinary times but is suffering difficulty in weeding work by strong self-generation power. In the meantime, going side by side with these manual processing and weeding work through construction of weed-proof seat is attaining, but economic performance, limitation of application region and withdrawal processing problem are being blamed for shortcoming. The scope of this study is about the manufacture of weed-proof mortar using eco-friendly industrial byproducts characterized by an economic and simplicity for not limited to loss of function as a product recovered after treatment. After the carried out the various experiments and actual construction for the selection of mixing materials and derivation of appropriate mix, through the comparison and analysis of results, it was investigated the research results of weed-proof mortar for fundamental development.

The Explosion-proof Performance of HPFRCC According to Fiber Combination and Mixing Ratio (섬유조합 및 혼입율 변화에 따른 HPFRCC의 방폭성능)

  • Lee, Jea-Hyeon;Lee, Jong-Tae;Jung, Woung-Seon;Jo, Sung-Jun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.88-89
    • /
    • 2017
  • Due to the increase in the usage of explosive materials and terrorism, the interest towards the superior explosion protective HPFRCC has risen. In existing research, the optimum ratio for solving the problematic problems such as the optimum fiber incorporation rate and the self-shrinkage crack of HPFRCC had been derived. However, there had been few or even no research upon how effective HPFRCC would perform protective explosion-proof in actual explosion. Therefore, this research compared the explosion-proof performance of HPFRCC according to fiber commination and mixing ratio. As a result, the combination of steel fiber and organic fiber showed excellent flow and strength, and it also improved the explosion resistance.

  • PDF

Explosion Proof of Fiber Reinforced Cement Composite Panel subjected to Contact Explosion (접촉폭발에 의한 섬유보강 시멘트 복합체의 방폭성능)

  • Kim, Yun-Hwan;Kim, Gyu-Yong;Kim, Hong-Seop;Lee, Bo-Kyeong;Lee, Sang-Gyu;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.128-129
    • /
    • 2016
  • This paper evaluates experimentally the explosion proof of fiber reinforced cement composite(FRCC) panels with various fibers of 2 % volume fraction subjected to contact explosions using an emulsion explosive. As a results, the proportion of the total damage in FRCC panels is not biased scabbing on the rear side with contrast to plain panels, which means that the local damage of FRCC panels was significantly controlled. The experimental results presented useful information for prediction of limited thickness on the local damage subjected to contact explosions through comparison with existing damage evaluation prediction equations.

  • PDF

Tests of Fire and Flame Retardant Performance for Membrane Materials (막재료의 난연 및 방염성능 실험에 대한 연구)

  • Kim, Gee-Cheol;Choi, Kwang-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.55-60
    • /
    • 2016
  • The Membrane structure has a number of problems in the application of a fireproof code based on general buildings codes. Thus, the fireproof code of membrane structure is necessary to activate the construction of the membrane structure. Because it requires a systematic classification of fire retardant and flame proof performance of membrane material. Fire retardant and flame proof tests are conducted on membrane materials mostly used in current construction to propose the fire and flame retardant performance criteria of membrane materials. Fire and flame retardant tests results, PTFE membrane material with the glass fiber fabric have a limit-combustible performance. PVDF membrane material with the polyester fabric does not ensure the fire retardant performance, but this membrane material has the flame retardant performance of a thick fabric. Also, ETFE does not ensure the fire retardant performance, but this membrane material has the flame retardant of a thin fabric.

A Study on the Light Weight Hand Lamp for Explosion-Proof Type (휴대형 방폭등의 경량화 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • For lighting of dark and hazardous workplace such as compartment of ships under construction, workers should use hand lamps of explosion-proof type. However, the heavy weight of such lamps has prevented most impatient workers from using such types of lamps extensively. In this paper, we developed a light weight hand lamp of intrinsic safety type which reduced the weight a lot while maintaining or improving the lighting and explosion-proof function. We made a prototype which consisted of lamp fixture and high frequency power supply. Testing results show that the hand lamp meets well all the explosion-proof testing requirements of the Korea Occupational Safety and Health Agency. And more, we surveyed the explosion protection technology of a light weight hand lamp, and suggested the advantage/disadvantage to apply lighting of hand lamp about economical aspect.

Explosion-proof Properties of High Strength Steel Fiber Reinforced Concrete made with Contents of Steel Fiber (섬유혼입율 변화에 따른 고강도 섬유보강 콘크리트의 방폭특성)

  • Han, Cheon-Goo;Kim, Seong-Soo;Park, Goo-Byeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.3
    • /
    • pp.129-136
    • /
    • 2000
  • In the side of military purpose, the explosion proof concrete, which contributes to protect the military facilities from damages due to the explosion of bomb and to maintain their shapes, is required to develop, Therefore. in this paper, mechanical and explosion-proof properties of concrete are tested under various steel fiber contents and member size. According to the experimental results, compressive, tensile and flexural strength gain higher levels with an increase in fiber contents. It shows that energy bearing capacities are higher with an increase in fiber contents. Especially. it is confirmed that slurry infiltrated fiber concrete(SIFCON) gains high strength and has high energy bearing capacities. SIFCON is expected to be applied in the construction of explosion proof structures.

  • PDF