• Title/Summary/Keyword: Prong

Search Result 20, Processing Time 0.029 seconds

Method for Manufacturing Single Prong Pendant Jewelry Using Trench Process (트렌치 공정을 이용한 단발난집 펜던트 주얼리의 개발)

  • 송오성;김익환;이하연
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.7-10
    • /
    • 2001
  • Recently, most jewelry design employ multiple prongs that grasp the front surface of the jewel to the metal frame To keep up with recent trends in fashion. jewelry manufacturers need to produce single-prong neckalces and earings constructed with non-precious metals. In responce to this demand, Ameth Development Division and The University of Seoul researched jointly and developed a technique for setting the jewel safely using a single prong with less weight. The setting process consists of making a small trench through the jewel at the mounting point and using a low melting point tin solder, to fill the trench and bonding with the prong. The application or this technology in the setting of a natural amethyst to a single 18K gold prong resulted in a 40% reduction in cost and weight and improvement of feeling for wearing.

  • PDF

Effects of Extranasal Molding after Primary Cleft Lip Nasal Repair: Photogrammetric Analysis (구순열비교정술 후 외비주형술(Extranasal molding): 비주길이의 사진계측학적 분석)

  • Han, Ki Hwan;Paik, Dae Hyang;Son, Hyung Bin;Kim, Jun Hyung;Son, Dae Gu
    • Archives of Plastic Surgery
    • /
    • v.33 no.5
    • /
    • pp.563-569
    • /
    • 2006
  • Purpose: In the correction of cleft lip, there have been various methods to minimize recurrence of the nasal deformity after primary nasal surgery. After cheiloplasty and primary nasal surgery, we tried to elongate the columella of the cleft side, to stretch the vestibular lining of cleft side, and to elevate the alar cartilage of the cleft side with a molding prong. Methods: We had fifteen cleft lip patients; 12 unilateral cases(6.3-8.2 months), and 3 bilateral cases(3 - 7.5 months). Immediately after primary repair of the cleft lip, the toboggan shaped molding prong was located to deep inside of vestibular web of the cleft side. It was persistently suspended by a silicone tube which was connected to the prong and the frontal scalp. The results were analyzed with $Photoshop^{(R)}$ photogrammetrically for 6 - 48 months with on average of 20.6 months. We measured the proportion index of columellar length-interalar distance for three times(preoperation, immediate postoperation, and postoperation) on the nasal base views. Results: In unilateral, the index had a significant increase statistically between preoperation(10.73) and immediate postoperation(23.96). It is supposed that columellar length was reconstructed to 105.80% of normal side. But, it was decreased to maintain 87.7% of normal side in postoperation(20.54). The results were similar in bilateral. The linear scars by suture penetrating nose skin were not discernable. Conclusion: In summary, placement of the molding prong could elongate the reconstructed columella with some relapse postoperatively.

Enhance of Dissolved Oxygen Rate using a 3-prong Nozzle (3구 노즐을 이용한 산소의 용존율 향상)

  • Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.24 no.7
    • /
    • pp.947-954
    • /
    • 2015
  • Dielectric barrier discharge plasma is a new technique in water pollutant degradation, which that is characterized by the production of chemically active species such as hydroxyl radicals, ozone, hydrogen peroxide, etc. If dissolving of plasma gas generated in the plasma reaction has increased, it is possible to increase the contaminant removal capacity. In this study, the improvement on the dissolving performance of plasma gas was evaluated by the indirect method measuring the overall oxygen transfer coefficient. Experiments were conducted to examine the effects of nozzle type, distance from water surface, air supply rate and liquid circulation rate. The experimental results showed that the $K_{La}$ value of the 3-prong nozzle is 2.67 times higher than the diffuser. The order of $K_{La}$ value with nozzle type ranked in the following order: 3-prong nozzle (inner diameter, less 1 mm) > circular nozzle (inner diameter, 1.5 mm) > ellipse nozzle (short diameter 1 mm, long diameter 2.5 mm) > circular nozzle (inner diameter, 3 mm). Optimal liquid circulation rate was appeared to be 1.7 L/min, the value of $K_{La}$ was 0.510 1/min. The value of $K_{La}$ with increasing air supply rate was revealed in the form of an exponential such as $K_{La}=0.3581e^{0.2919^*air\;flow\;rate}$.

Simple fiber tip assembly with flexible Quality factor (유연한 Quality factor가 가능한 단순한 광섬유 팁 공진 구조물)

  • 나경필;권오대
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.11a
    • /
    • pp.260-261
    • /
    • 2002
  • For Near-field Scanning Optical Microscopy measurements, the fiber tip is glued on the side of one of the tuning fork prongs vertically to its extended direction. Higher Q-factor is attainable in this geometry than in the arrangement with the fiber tip parallel to the prong. A simple mechanical design is applied to hold the fiber tip above the gluing point. The overall tuning fork-fiber tip assembly gives another advantage of the flexible Q-factor enhancement. With this treatment, Q-factor higher than 3000 is easily achievable. As an operating instance, a grating is scanned for its one dimensional topographical image.

  • PDF

A study on the application of urban railway DC electric power for electric car charging system (전기차 충전시스템을 위한 도시철도 DC 전력의 활용방안 연구)

  • Kang, Hyun-Il;Kin, Youn-Sik;Sim, Jae-Suk;Im, Hyeong-Gil;Ryu, Ki-Seon;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1855-1860
    • /
    • 2010
  • Electric vehicles have reached a new level of development with introductions by Chrysler, Ford, Honda and Toyota. Today's charging technology includes conductive and inductive charging systems. There are three standardized charging levels: Level 1: charging can be done from a standard, grounded AC 120V, 3-prong outlet available in all homes; Level 2: charging is at AC 240V, 40 amp charging station with special consumer features to make it easy and convenient to plug in and charge EVs at home or at an EV charging station; Level 3: a high-powered charging "fast charge" technology currently under development that will provide a charge in less than 15 minutes. The incoming AC power is converted to DC and stored in the vehicle's batteries. In this paper, we investigated the application of urban railway DC electric power for electric car charging system.

  • PDF

Quantitative Doppler echocardiography during Dobutamine stress test in canine mitral regurgitant model

  • Choi, Hojung;Won, Sungjun;Lee, Kichang;Choi, Mincheol;Yoon, Junghee
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.2
    • /
    • pp.317-322
    • /
    • 2004
  • This study was performed to evaluate echocardiographic parameters in dogs with experimental mitral regurgitation subjected to dobutamine stress testing. In 8 beagle dogs, a 4-prong grasping forceps was inserted into the left ventricle through the carotid artery with fluoroscopic guidance. The disruption of chordae or mitral valve leaflet was performed. Echocardiographic protocols included quantitative Doppler echocardiography and M-mode measurement for evaluating left ventricle function. After all measurement was obtained at rest, dobutamine was infused incrementally. In stress testing, all measurement also was performed at rest as the same method. In stress Doppler echocardiography, regurgitant fraction and aortic stroke volume was increased significantly (P<0.001). Effective regurgitant orifice and regurgitant volume was not changed. In M-mode examination, fractional shortening was increased significantly at stress test (P<0.001). From the results obtained in this study, it could be suggested that dobutamine stress echocardiography increase left ventricle performance in non-functional mitral regurgitation and quantitative Doppler echocardiography is non-invasive, accurate method in valvular regurgitation.

Dithering Sample Stage Based Near-field Scanning Optical Microscope

  • Park, Gyeong-Deok;Jeong, Mun-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.559-559
    • /
    • 2012
  • We developed a new scheme for the highly sensitive near-field scanning optical microscope (NSOM) by using a dithering sample stage rather than a dithering probe. In the proposed scheme, the sample is directly loaded on one prong surface of a dithering bare tuning fork. Gap control between probe and sample is performed by detecting the shear force between an immobile fiber probe and the dithering sample. In a conventional NSOM, the Q factor drastically decreases from 7783 to 1000 or even to 100 by attaching a probe to the tuning fork. In our proposed NSOM, on the contrary, the Q factor does not change significantly, 7783 to 7480, when the sample is loaded directly to the tuning fork instead of attaching a probe. Consequently, the graphene sheets that cannot be observed by a conventional NSOM were clearly observed by the proposed method with sub-nanometer vertical resolution due to the extremely high Q factor.

  • PDF

Clinical Test of prototype Oxygen Concentrator (국산 산소농축기 시제품의 임상시험)

  • Kim, Seung-Chul;Sung, Sook-Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.1
    • /
    • pp.44-52
    • /
    • 2001
  • Background : Oxygen concentrators are convenient to operate and economical for patients with chronic obstructive pulmonary disease (COPD). However, oxygen concentrators are not manufactured domestically and the COPD patients are currently treated with imported oxygen concentrators. To evaluate the efficacy and safety of domestically developed prototype oxygen concentrator before clinical application, the efficacy and safety of the domestic oxygen concentrator were evaluate by comparing with the imported one. Material and Methods : The clinical tests were performed on 36 hyperhydrosis patients from April 1999 to August 1999. Domestic and imported oxygen concentrators were in turn applied to the same patient, who inspired oxygen for 60 minutes at a rate of 3 liters per minute through nasal prong. The oxygen concentrator, which was applied first, was randomly allocated. The arterial partial oxygen pressure ($PaO_2$) was estimated to compare the efficacy; and the carboxy hemoglobin(COHb), pH, arterial $CO_2$ partial pressure, pulse rate, blood pressure, and respiration rate to compare the safety before and after applying each oxygen concentrator. A student t-test was used to analyze the results. Result : In respect to efficacy, the difference in the change of $PaO_2$ before and after the application between two concentrators was not statistically significant. In respect to safety, the differences in the changes of COHb, pH, partial pressure of arterial $CO_2$, pulse rate, blood pressure, respiration rate between two concentrators were also not statistically significant. Conclusion : The domestically developed oxygen concentrator, showed satisfactory efficacy and safety when compared with the imported one.

  • PDF

Analysis of residual drying stress in Larix Kaempferi wood used as glulam laminar (집성재 라미나용 낙엽송 재내 잔류 건조응력 변화 분석)

  • Han, Yeonjung;Chang, Yoon-Seong;Park, Yonggun;Jeong, Gi-Young;Hong, Jung-Pyo;Lee, Jun-Jae;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.535-543
    • /
    • 2013
  • The objective of this study was to analyse the residual stress in Larix kaempferi board during and after kiln-drying. The boards were primarily intended for using as laminar of cross laminated timber (CLT). In this study, the equivalence of moisture content by equalizing treatment was proved and reduction of residual stress by conditioning treatment was quantified. Prong test and slice test were carried out to analyse the residual stress in wood during drying. Transverse casehardening was measured immediately after making prong sample. Residual stress of four parts in wood from surface to center was analyzed quantitatively based on elastic deformation after just cutting slices from board. Tensile stress and compressive stress on the surface of board during drying did not exceed 2.2 MPa when boards were dried by kiln-drying schedule of T10-C4 and T12-D5. Because the tensile strength and compressive strength of transverse direction of Larix kaempferi lumber are 2.65 MPa and 4.60 MPa, application of more severe drying schedule can be recommended. Cup and twist were reduced by about 40% by equalizing and conditioning treatments after drying.

Study of Potential Future Occupations in the Environmental Industry - Focusing on Delphi Survey - (환경산업의 유망직업 추출에 관한 연구 - 델파이 조사를 중심으로 -)

  • Han, Sang-Geun;Park Jong-Sung;Kim, Na-Ra
    • Hwankyungkyoyuk
    • /
    • v.17 no.1
    • /
    • pp.154-169
    • /
    • 2004
  • This research presents an analysis of some of the occupations associated with Korea‘s national strategic industries. Therefore, the objectives of this paper can be summarized as follows: By classifying existing occupations and identifying potential future ones, this paper will strive to present a systematic analysis of environmental related occupations. In order to achieve the objectives of this research, related literature was examined, a Delphi Survey was conducted. In order to select potential future occupations, this research used a qualitative method that involved interviews with specialists. More specifically, a Delphi Survey was used to collect the specialists' opinions. The potential occupations were selected using a three-prong procedure involving an analysis of related literature and materials, a Delphi Survey, as well the holding of conferences with specialists and visits to those in the actual field. Through this process, 33 different potential future occupations were selected.

  • PDF