Real-time Geometric Correction System for Digital Image Projection onto Deformable Surface (변형 가능한 곡면에서의 디지털 영상 투영을 위한 실시간 기하 보정 시스템)

  • Lee, Young-Bo;Han, Sang-Hun;Kim, Jung-Hoon;Lee, Dong-Hoon;Yun, Tae-Soo
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.39-44
    • /
    • 2008
  • This paper proposes a real-time geometric correction system based on a projector to project digital images onto deformable surface. Markers use to trace lots of corresponding points would spoil the projected image when the projector projects a digital image onto the surface because they leave marks on the surface. In addition, it is difficult to build a real-time geometric correction system since bottlenecks occur through the process of the geometric correction for projecting images. In this paper, we use invisible infrared markers and a vertex shader of GPU using Cg TookKit of NVIDIA in order to eliminate disadvantage and bottlenecks in the process of markers recognition so that it is possible to project natural correction images in real-time. As a result, this system overlays an interactive virtual texture onto the real paper by using the geometric transformation. Therefore, it is possible to develop variation of AR(Augmented Reality) based on digital contents systems.

  • PDF

Fast 3-dimensional profifle measurement using slit-ray projection method

  • Ishimatsu, T.;Kawasue, K.;Kumon, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.786-790
    • /
    • 1987
  • This paper describes a systein which enables a fast 3 -dimensional profile measurement using a slit-ray projection method. One distinctive feature of this system is that a real-time video is processor is employed in order to reduce the amount of image data to be processed without eliminating essential information. Experimental results show that a calibrating method presented for the TV camera and the slit-ray projector is convenient and enables sufficient accurate measurements.

  • PDF

Development of Camera Controller with Pointer Tracking Unit (카메라 컨트롤러를 이용한 포인터 추적 장치 개발)

  • Lee, Yong-hwan;Ju, Hyun-woong;Song, Sung-hae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.3
    • /
    • pp.111-117
    • /
    • 2008
  • Presentation with a projector and a laser pointer is widely used in seminar or conference. The function of a laser pointer in the presentation is just indicating a certain object. In this paper, to give a mouse-like function to a laser pointer, we implement a system that locates the track of a laser pointer. The system contains a FPGA that implements camera interface and noise filter. A software for ARM processor is programmed to analyze the spectrum of the captured image and track the pattern of a laser pointer with previously stored image. As a result, the tracking system could locate the position correctly most of time within 20m with 98% accuracy.

  • PDF

Development of Peripheral Devices on the Endoscopic Surgery System (내시경 수술시스템의 주변장치 개발)

  • Lee, Young-Mook;Song, Chul-Gyu;Lee, Sang-Min;Kim, Won-Ky
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.164-166
    • /
    • 1995
  • The objectives of study are to develop a peripheral device on the endoscopic surgery system. These systems are consist of the following units. They are a color monitor of high resolution, light source, computer system and endoscopic camera with a C-mount head, irrigator, color video printer, Super VHS recorder and a system rack. The color monitor is a NTSC monitor for monitoring the image projected of the surgical section. The lightsource is necessary to irradiate the interior of a body via an optic fiber, The light projector will adapt the brightness in accordance with changing distance from the object. A miniature camera using a color CCD chip and computer system is used to capture and control an image of the surgical section[1]. The video printer is a 300 DPI resolution using thermal sublimation methods, which is developed by Samsung Electronics Co., Ltd. The specification of the endoscopic data management system is consist of storage of a captured image and pathological database of patients [2-4].

  • PDF

Issues in Control of a Robotic Spatial Augmented Reality System (로보틱 공간증강현실 시스템의 제어의 문제)

  • Lee, Joo-Haeng;Kim, Hyun;Suh, Young-Ho;Kim, Hyung-Sun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.6
    • /
    • pp.437-448
    • /
    • 2011
  • A robotic spatial augmented reality (RSAR) system combines a robotics technology with a spatial augmented reality system (SAR) where cameras are used to recognize real objects and projectors augment information and user interface directly on the surface of the recognized objects, rather than relying on handheld display devices. Moreover, a robotic module is actively used to discover and utilize the context of users and environments. The control of a RSAR system involves several issues from different technical fields such as classical inverse kinematics of motors where projector-camera pairs are mounted, inverse projection problems to find appropriate internal/external parameters of projectors and cameras, and image warping in graphics pipeline to compensate the kinematic constraints. In this paper, we investigate various control issues related to a RSAR system and propose basic approaches to handle them, specially focused on the prototype RSAR system developed in ETRI.

Three dimensional data acquisition system using structured light and image processing (구조화 조명과 영상 처리를 이용한 3차원 데이터 획득 시스템)

  • 전희성;박제홍;고문석
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.5
    • /
    • pp.83-93
    • /
    • 1998
  • Three dimensional data acquisition system based on the structured light is developed in this work. The system is composed of a CCD camera, slide projector, and various image processing programs. Calibration procedures and several image processing steps which are necessary to get the rnage data are described. A new grid labeling technique and a grid pattern are devised to improve the accuracy of th eobtained data. Preliminary experimental result shows that the developed system may be used as a simple and cheap 3D data acquisition system. Severla suggestions are included for further research.

  • PDF

Depth Evaluation from Pattern Projection Optimized for Automated Electronics Assembling Robots

  • Park, Jong-Rul;Cho, Jun Dong
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.4
    • /
    • pp.195-204
    • /
    • 2014
  • This paper presents the depth evaluation for object detection by automated assembling robots. Pattern distortion analysis from a structured light system identifies an object with the greatest depth from its background. An automated assembling robot should prior select and pick an object with the greatest depth to reduce the physical harm during the picking action of the robot arm. Object detection is then combined with a depth evaluation to provide contour, showing the edges of an object with the greatest depth. The contour provides shape information to an automated assembling robot, which equips the laser based proxy sensor, for picking up and placing an object in the intended place. The depth evaluation process using structured light for an automated electronics assembling robot is accelerated for an image frame to be used for computation using the simplest experimental set, which consists of a single camera and projector. The experiments for the depth evaluation process required 31 ms to 32 ms, which were optimized for the robot vision system that equips a 30-frames-per-second camera.

Development of 3D Scanner Based on Laser Structured-light Image (레이저 구조광 영상기반 3차원 스캐너 개발)

  • Ko, Young-Jun;Yi, Soo-Yeong;Lee, Jun-O
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.3
    • /
    • pp.186-191
    • /
    • 2016
  • This paper addresses the development of 3D data acquisition system (3D scanner) based laser structured-light image. The 3D scanner consists of a stripe laser generator, a conventional camera, and a rotation table. The stripe laser onto an object has distortion according to 3D shape of an object. By analyzing the distortion of the laser stripe in a camera image, the scanner obtains a group of 3D point data of the object. A simple semiconductor stripe laser diode is adopted instead of an expensive LCD projector for complex structured-light pattern. The camera has an optical filter to remove illumination noise and improve the performance of the distance measurement. Experimental results show the 3D data acquisition performance of the scanner with less than 0.2mm measurement error in 2 minutes. It is possible to reconstruct a 3D shape of an object and to reproduce the object by a commercially available 3D printer.

Development of a Noncontact Three Dimensional Foot Form Measurement System with Optical Triangulation (광삼각법을 이용한 비접촉 3차원 족형 측정 시스템 설계)

  • 박인덕;안형회;송강석;이희만;김시경
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.5
    • /
    • pp.368-373
    • /
    • 2003
  • This paper presents a cost-effective 3D foot scanner system that provides the 3-dimensional point cloud foot data to design the custom footwear. To measure the 3-dimensional point cloud data of the foot, a CCD camera, a Non-Gaussian laser line projector and optical triangulation method are employed. Furthermore, the integrated system employs a measurement base, a frame grabber, a CCD moving cart, a stepping motor and a computer. The measurement result is saved as 3D dxf format and it could be converted to 2D essential data fer a shoe design. The experimental results demonstrate that the proposed system have the decent resolution of 1mm which is enough for last and shoe design.

Application of 3-D Scanner to Analysis of Functional Instability of the Ankle

  • Han, Cheng-Chun;Kubo, Masakazu;Matsusaka, Nobuou;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1971-1975
    • /
    • 2003
  • This paper describes a technique, which analyzes the functional instability of the ankle using three-dimensional scanner. The technique is based on the structured light pattern projection method, which is performed by using one digital still camera and one LCD projector. This system can be easily realized with the low cost. The measuring result has high accuracy. The measuring error is about 0.2 mm or less. Using this technique the three-dimensional posture of the leg and foot of the target person are measured and analyzed.

  • PDF