• Title/Summary/Keyword: Profile measurements

Search Result 541, Processing Time 0.03 seconds

Studies on Ntrient Intake, Blood Lipids, and Body Fat Distribution in Diabetics (당뇨병 환자의 영양소 섭취량과 혈청 지질 및 체지방 분포)

  • 최미자;김미경
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.5 no.3
    • /
    • pp.223-232
    • /
    • 1995
  • This study was an attempt to compare the energy, nutrient intake, blood lipids, and body fat distribution of diabetics with those of normal control subjects. Daily energy and nutrient intake were measured by convenient method. The following anthropometric measurements were made on all participants : weight, height, and waist and hip circumference. We matched 31 pairs with diabetics and nondiabetic control subjects by sex, age, body weight and height, and made comparisons between two groups to observe the effect of diabetes in lipid profiles. Aslo the effect of exercise in diabetes was investigated. The results obtained were as follows : 1.The average of daily energy intake of diabetics was 1, 927 kcal and that of nondiabetics was 2, 159 kcal. Percentage of energy in diabetics is that carbohydrate : protein : fat = 69:13:18 2. When diabetics were divided into obese and nonobese group according to RBW, 33% of diabetics were obese and energy intake was not significantly different between the two groups, but VLDL - cholesterol concentration was significantly higher in the obese group. 3. Energy intake, BMI, RBW and total cholesterol level of upper obesity group were significantly higher than those of lower body obesity group in male diabetic subjects. 4. When matching 31 pairs of diabetics and nondiabetics according to sex, age, body weight and height triglyceride concentration and WHR of diabetics were measured to be significantly higher than those of nondiabetics. 5. Although energy intake was not significantly different between exercise and nonexercise groups, triglyceride, blood glucose, RBW, BMI were significantly lower in the exercise and nonexercise groups, triglyceride, blood glucose, RBW, BMI were significantly lower in the exercise group than the nonexercis group in diabetics. 6. BMI and RBW were not correlated with cholesterol or triglyceride, but WHR correlated significantly with both cholesterol and triglyceride. In conclusion, diabetics had higher triglyceride concentration and WHR than nondiabetics. WHR may be better than BMI or RBW for predicting alteration in lipid profile and exercise seems beneficial for controlling blood glucose and lipids in diabetics.

  • PDF

OPTICAL AND NEAR-INFRARED IMAGING OF THE IRAS 1-JY SAMPLE OF ULTRALUMINOUS INFRARED GALAXIES

  • KIM D.-C.
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.159-165
    • /
    • 2003
  • Optical (R) and near-infrared (K') images of the IRAS 1-Jy sample of 118 ultraluminous infrared galaxies have been studied. All but one object in the 1-Jy sample show signs of strong tidal interaction/merger. Most of them harbor a single disturbed nucleus and are therefore in the later stages of a merger event. Single-nucleus ULIGs show a broad distribution in host magnitudes with significant overlap with those of quasars. The same statement applies to R - K' colors in ULIG and quasar hosts. An analysis of the surface brightness profiles of the host galaxies in single-nucleus sources reveals that about $35\%$ of the Rand K' surface brightness profiles are well fit by an elliptical-like $R^{1/4}$-law, while only $2\%$ are well fit by an exponential disk. Another $38\%$ of the single-nucleus systems are fit equally well with an exponential or de Vaucouleurs profile. Elliptical-like hosts are most common among merger remnants with Seyfert 1 nuclei ($83\%$) and Seyfert 2 optical characteristics ($69\%$). The mean effective radius of these ULIGs is 4.80 $\pm$ 1.37 kpc at Rand 3.48 $\pm$ 1.39 kpc at K'. These values are in excellent agreement with recent quasar measurements obtained at H with HST. The hosts of elliptical-like 1-Jy systems follow with some scatter the same ${\mu}e - r_e$ relation, giving credence to the idea that some of these objects may eventually become elliptical galaxies if they get rid of their excess gas or transform this gas into stars.

Error Analysis for Electromagnetic Surface Velocity and Discharge Measurement in Rapid Mountain Stream Flow (산지하천의 전자파 표면유속 측정에 기반한 유량 및 유속 관측 오차 분석)

  • Kim, Dong-Su;Yang, Sung-Kee;Jung, Woo-Yul
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.543-552
    • /
    • 2014
  • Fixed Electromagnetic Wave Surface Velocimetry (Fixed EWSV) has been started to be used to measure flood discharge in the mountain stream, since it has various advantages such that it works well to continuously measure stream discharge even in the night time as well as very strong weather. On the contrary, the Fixed EWSV only measures single point surface velocity, thus it does not consider varying feature of the transverse velocity profile in the given stream cross-section. In addition, a conventional value of 0.85 was generally used as the ratio for converting the measured surface velocity into the depth-averaged velocity. These aspects could bring in error for accurately measuring the stream discharge. The capacity of the EWSV for capturing rapid flow velocity was also not properly validated. This study aims at conducting error analysis of using the EWSV by: 1) measuring transverse velocity at multiple points along the cross-section to assess an error driven by the single point measurement; 2) figuring out ratio between surface velocity and the depth-averaged velocity based on the concurrent ADCP measurements; 3) validating the capacity of the EWSV for capturing rapid flow velocity. As results, the velocity measured near the center by the fixed EWSV overestimated about 15% of the cross-sectional mean velocity. The converting ratio from the surface velocity to the depth-averaged velocity was 0.8 rather than 0.85 of a conventional ratio. Finally, the EWSV revealed unstable velocity output when the flow velocity was higher than 2 m/s.

Framework of Conceptual Estimation Model for BIM based Internal Finishes of High-rise Building Project (BIM기반의 초고층 빌딩 내부마감 개략견적 코스트모델 개발)

  • Chung, Suwan;Kwon, Soonwook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.2
    • /
    • pp.53-61
    • /
    • 2014
  • Previous studies reveal the need for a tool to cost estimation of building design in early design stages. This paper proposes an internal finishes cost model tool to address this need. The tool allows users to evaluate the functionality, economics and quality of finishes concurrently with high-rise building design. Lack of information in the early stages of the project enables a relatively accurate estimates of work to raise up. Measurements are automatically extracted from simple design information and profile driven estimates are revised in real-time. The data model uses a flexible unit rate system that can easily be extended to other estimate dimensions such as mix-use building surcharge rate estimation. The approach illustrated in this paper is applicable to BIM tool conceptual estimation that support for massing purposes other than the one chosen for this study.

Relationship between atrial pressures and the interventricular pressure in the moving actuator type total artificial heart (심실간 공간 압력을 이용한 이동작동기형 완전이식 인공심장에서의 좌, 우심방압 추정)

  • Jo, Y.H.;Choi, W.W.;Park, S.K.;Choi, J.S.;Lee, J.J.;Om, K.S.;Kim, H.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.88-90
    • /
    • 1996
  • The right and left atrial pressures are important parameters in automatic control of a total artificial heart (TAH) within normal physiological ranges. Our TAH is composed of a moving actuator, right and left ventricles and the interventricular space enclosed by a semi-rigid housing. During operation of the TAH, the jnterventpicular space's volume is changed dynamically by the difference between the ejection volume of one ventricle and the inflow volume of the other. Therefore, the changes in pressure of the interventricular space is related to both atrial pressures. We measured the interventricular pressure (IVP) waveform using a pressure sensor and attempted to indirectly estimate the changes of atrial pressures. This method has an advantage that the sensor does not contact the blood directly. Furthermore, the IVP waveforms have its zero baseline in each pump cycle, thus the pressure measurements are free from the transducer drift problems by measuring the peak pressure from these baseline values. From the In vitro experiments, we found that the IVP waveform contained several useful parameters such as negative peak, dP/dT on the initial break, the area enclosed by the profile in each stroke, which are associated with atrial pressures and the filling conditions of the ventricles. The measured atrial pressures were linearly related to the negative peak of the interventricular pressure.

  • PDF

Multiple-Point-Diffraction Interferometer : Error Analysis and Calibration (거친 표면 형상측정을 위한 점광원 절대간섭계의 오차해석과 시스템 변수의 보)

  • Kim, Byoung-Chang;Kim, Seung-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.361-365
    • /
    • 2005
  • An absolute interferometer system with multiple point-sources is devised for tile 3-D measurement of rough surface profiles. The positions of the point sources are determined to be the system parameters that influence the measurement accuracy, so they are calibrated precisely prior to performing actual measurements. For the calibration, a CCD camera composed of a two-dimensional array of photo-detectors was used. Performing optimization of the cost function constructed with phase values measured at each pixel on the CCD camera, the position coordinates of each point source is precisely determined. Measurement results after calibration performed for the warpage inspection of chip scale packages (CSPs) demonstrate that the maximum discrepancy is 9.8 mm with a standard deviation o( 1.5 mm in comparison with the test results obtained by using a Form Taly Surf instrument.

The Change of Bone and Soft Tissue Profile after Sagittal Split Osteotomy of Ramus (하악골후방이동술 후 골격구조와 연부조직의 변화)

  • Hwang, Jee Hoon;Seul, Chul Hwan;Park, Beyoung Yun
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.547-554
    • /
    • 2005
  • Orthognathic surgery for Class III malocclusion requires an elaborate preoperative planning using cephalometries or Mock surgery models which enable the surgeon to anticipate postoperative skeletal changes of maxilla and mandible as well as dentition. After surgery, patient's satisfaction is greatly influenced by appearance of soft tissue change. Therefore, it is imperative to predict a relatively accurate soft tissue change prior to surgery. A 5 year retrospective study was designed to evaluate the soft tissue change after sagittal split osteotomy of ramus(SSRO) for class III malocclusion. Analyses of preoperative and postoperative anthropometric measurements were performed. Patients who were treated only by SSRO for class III malocclusion and could follow up for 6 months were studied. Among them, the patients who had history of cleft palate and lip or hemifacial microsomia were excluded. Soft tissue changes were estimated by using the frontal and lateral photographs. Skeletal changes were observed by measuring amount of set back and angular changes of mandible to the reference line by using cephalometries. Relapses were also measured 6 months after the operation. We could observe skeletal changes were more profound than soft tissue changes concerning amount of set back, but soft tissue changes were also profound in angle. Relapse was more profound in skeleton than soft tissue but the amount was not significant. In spite of the variables which may affect proper assessment of the soft tissue change after skeletal relocation, this study can serve as a guide for exact prediction of the postoperative change of soft tissue and skeleton.

Turbulent Couette Flow between Coaxial Cylinders with Inner Cylinder Rotating (내측원관이 회전하는 동심이중원관 사이의 난류 쿠에트 유동에 관한 연구)

  • 김광용;김진욱;조용철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.540-546
    • /
    • 1992
  • Turbulent Couette flow between coaxial cylinders with inner one rotating has been investigated experimentally and numerically. The radius ratio of the coaxial cylinders is 0.43. Mean velocity and turbulent stresses have been measured by hot-wire anemometer in the range of Reynolds number based on the velocity at rotating wall and the radial distance between walls, 60,900-187,000. For the numerical computation, the Reynolds stress model has been used as a turbulence closure model. Measurements of mean velocity show that the velocity profile of wall layer largely deviates from universal logarithmic law due to the effect of streamline curvature, especially in the region near the stationary outer cylinder. The results computed with the Reynolds stress model agree well with the experimental data in the prediction of circumferential intensity of turbulent fluctuations. However, the computed level of radial intensity is much higher than the measurement. Curvature-corrected versions of the Reynolds stress model improves the prediction of turbulent intensities, but the results are not fully satisfactory.

Experimental investigation on the heat transfer characteristics of an oscillatory pipe flow (원관 내 왕복유동에 따른 열전달특성의 실험적 연구)

  • Park, Sang-Jin;Lee, Dae-Yeong;No, Seung-Tak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.6
    • /
    • pp.1959-1970
    • /
    • 1996
  • Effects of oscillatory flow upon heat transfer characteristics have been studied experimentally for oscillating flow in a circular tube. The experimental apparatus was designed to simulate the heat exchangers of the Stirling or Vuilleumier cycle machines and the test section consists of heater and cooler. Measurements were presented of heat flux, axial wall temperature distribution, and radial temperature profile of the working fluid for several cases of oscillation frequency and swept distance ratio. The influences of two main parameters, frequency and tidal displacement of the oscillation were investigated. Then the heat transfer coefficient at the heater is obtained. The carried by the authors with a assumption of oscillatory laminar slug flow.

Estimating the shear velocity profile of Quaternary silts using microtremor array (SPAC) measurements (Microtremor 배열 (SPAC) 측정을 이용한 제4기 실트층의 S파 속도구조 추정)

  • Roberts James;Asten Michael
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.34-40
    • /
    • 2005
  • We have used the microtremor method, with arrays of up to 96 m diameter, to carry out non-invasive estimation of shear-wave velocity profiles to a depth of 30 to 50 m in unconsolidated Quaternary Yarra Delta sediments. Two silt units (Coode Island Silt, and Fishermans Bend Silt) dominate our interpretation; the method yields shear velocities for these units with precision of $5\%$, and differentiates between the former, softer unit ($V_s$=130 m/sec) and the latter, firmer unit ($V_s$=235 m/sec). Below these silts, the method resolves a firm unit correlating with known gravels ($V_s$ 500 to 650 m/sec). Using surface traverses with the single-station H/V spectral ratio method, we show that the variation in thickness of the softer silt can be mapped rapidly but only qualitatively. The complexity of the geological section requires that array methods be used when quantitative shear-wave velocity profiles are desired.