• Title/Summary/Keyword: Profile measurements

Search Result 541, Processing Time 0.022 seconds

Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator (CLINAC 1800 선형가속기의 15 MV X-선의 특성)

  • Kim, Kye-Jun;Lee, Jong-Young;Park, Kyung-Ran
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.131-141
    • /
    • 1991
  • A comprehensive set of dosimetric measurements has been made on the Varian Clinac 1800 15 MV photon beam. Beam quality, percentage depth dose, dose in the build up region, output, symmetry and flatness, transmission through iead (Cerrobend), tray attenuation, isodose curves for the open and wedged fields were measured using 3 dimensional water phantom dosimetry system (including film densitometer system) and polystyrene phantoms. These dosimetric measurements sufficiently characterized the beam to permit clinical use. The depth dose characteristics of photon beam is $d_{max}$ of 3.0 cm and percentage depth dose of $76.8\%$ at 10 cm,100 cm source-surface distance, field size of $10\times10\;cm^2$ for 15 MV X-ray beam. The Output factors ranged 0.927 for $4\times4\;cm^2$ field to 1,087 for $35\times35\;cm^2$ field. The build-up level of maximum dose was at 3.0 cm and surface dose was approximately $15.5\%$ for a field size $10\times10\;cm^2$ The stability of output is $within\pm1\%$ and flatness and symmetry are $within\pm3\%$. The half value thickness (HVL) of lead is 13 mm, which corresponds to an attenuation coefficient of $0.053\;mm^{-1}$. These figures compare facorably with the manufacturesr`s specifications.

  • PDF

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

Development of Gated Myocardial SPECT Analysis Software and Evaluation of Left Ventricular Contraction Function (게이트 심근 SPECT 분석 소프트웨어의 개발과 좌심실 수축 기능 평가)

  • Lee, Byeong-Il;Lee, Dong-Soo;Lee, Jae-Sung;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.73-82
    • /
    • 2003
  • Objectives: A new software (Cardiac SPECT Analyzer: CSA) was developed for quantification of volumes and election fraction on gated myocardial SPECT. Volumes and ejection fraction by CSA were validated by comparing with those quantified by Quantitative Gated SPECT (QGS) software. Materials and Methods: Gated myocardial SPECT was peformed in 40 patients with ejection fraction from 15% to 85%. In 26 patients, gated myocardial SPECT was acquired again with the patients in situ. A cylinder model was used to eliminate noise semi-automatically and profile data was extracted using Gaussian fitting after smoothing. The boundary points of endo- and epicardium were found using an iterative learning algorithm. Enddiastolic (EDV) and endsystolic volumes (ESV) and election fraction (EF) were calculated. These values were compared with those calculated by QGS and the same gated SPECT data was repeatedly quantified by CSA and variation of the values on sequential measurements of the same patients on the repeated acquisition. Results: From the 40 patient data, EF, EDV and ESV by CSA were correlated with those by QGS with the correlation coefficients of 0.97, 0.92, 0.96. Two standard deviation (SD) of EF on Bland Altman plot was 10.1%. Repeated measurements of EF, EDV, and ESV by CSA were correlated with each other with the coefficients of 0.96, 0.99, and 0.99 for EF, EDV and ESV respectively. On repeated acquisition, reproducibility was also excellent with correlation coefficients of 0.89, 0.97, 0.98, and coefficient of variation of 8.2%, 5.4mL, 8.5mL and 2SD of 10.6%, 21.2mL, and 16.4mL on Bland Altman plot for EF, EDV and ESV. Conclusion: We developed the software of CSA for quantification of volumes and ejection fraction on gated myocardial SPECT. Volumes and ejection fraction quantified using this software was found valid for its correctness and precision.

THE ANTERIOR-POSTERIOR AND VERTICAL RELATIONSHIP OF THE GROWING CHILDREN WITH CLASS III MALOCCLUSION BY LATERAL CEPHALOMETRIC MEASUREMENT (측모두부방사선 사진을 이용한 성장기 III급 부정교합아동의 전후방적, 수직적 악골관계에 대한 연구)

  • Yang, Ku-Ho;Choi, Nam-Ki;Kim, Seong-Nam
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.291-297
    • /
    • 2003
  • While making diagnosis and the treatment plan for the growing children who visited at Chonnam National University Hospital for orthodontic treatment, authors obtained 8 lateral cephalometric measurements in antero-posterior and vertical relationship such as APDI, WITS, ANB, SN-MP, ODI, PFH/AFH, Y-axis, SUM for children aged 7 to 9 with class III malocclusion and compared them with these of 73 children of elementary school aged 7 to 9 with proper profile and normal occlusion in Gwangju. The results were as follows: 1. Between normal occlusion and class III malocclusion, ANB, SN-MP, ODI, SUM, except PFH/AFH and Y-axis showed statistically significant differences(p<0.05). 2. Between mesurements to describe skeletal disorder of antero-posterior relationship such as APDI, WITS, ANB and skeletal disorder of vertical relationship such as SN-MP, ODI, PFH/AFH, Y-axis, SUM, all of them in both normal occlusion and Class III malocclusion showed significant correlation, except Y-axis, SUM correlation(p<0.01). 3. Wald' statistics of WITS, ANB and APDI expressing skeletal disorder of antero-posterior relationship showed 7.118, 5.148, 0.741, respectively and Wald' statistics of ODI, Y-axis, PFH/AFH, SN-MP, SUM were presented 28.348, 2.238, 1.376, 0.090, 0.089, respectively. Therefore, WITS and ODI could be considered as useful diagnotic measurements for class III malocclusion.

  • PDF

Comparison of Enhanced Dynamic Wedge with Physical Metal Wedge based on the Basic Dosimetric Parameters (선량계측인자에 따른 기능강화동적쐐기와 금속쐐기의 비교)

  • Lee Jeong-Woo;Hong Semie;Choi Kyoung-Sik;Chung Jin-Beom;Choe Bo-Young;Jang Hong Seok;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.70-76
    • /
    • 2005
  • For clinical implementation of Enhanced Dynamic Wedge (EDW), it is necessary to adequately analyze and commission its dosimetric properties in comparison to common physical metal wedge (MTW). This study was implemented with the essential measurements of parameters for clinical application, such as percentage depth dose, peripheral dose, surface dose, effective wedge factor, and wedge profile. In addition, through the comparison study of EDW with open and MTW, the analysis was performed to characterize the EDW. We also compared EDW dose profiles of measured values using chamber array 24 (CA24) with calculated values using radiation treatment planning system. PDDs of EDW showed good agreements between $0.2\~0.5\%$ of open beam, but $2\%$ differences with MTW. In the result of the measurements of peripheral dose, it was shown that MTW was about $1\%$ higher than open field and EDW. The surface doses of $60^{\circ}$ MTW showed 10% lower than the others. We found that effective wedge factor of EDW had linear relationships according to Y jaw sizes and was independent of X jaw sizes and was independent of X jaw sizes and asymmetric Y jaw opening. In comparison with measured values and calculate values from Golden-STT based radiation treatment planning system (RTP system), it showed very good agreement within difference of $1\%$. It could be concluded that EDW is a very reliable and useful tool as a beam modification substitute for conventional MTW.

  • PDF

The Eating-Related Characteristics Questionnaire and Its Correlations with Anthropometry, Nutrient Intakes, Depression, and Personality Dimensions : the Validity of Its Use on Korean College Students (대학생을 대상으로 한 섭식특성 질문지의 타당성 연구 - 체격, 영양소 섭취, 우울 및 성격차원과의 상관성에 의한 -)

  • 신동순;조옥귀
    • Journal of Nutrition and Health
    • /
    • v.35 no.4
    • /
    • pp.489-497
    • /
    • 2002
  • This study was conducted to determine if Mehrabian's eating-related characteristics questionnaire could be effectively applied in predicting obesity and eating disorders among Korean college students by examining the correlations between eating-related characteristics and anthropometry, nutrient intakes, psychological aspects of depression, and personality dimensions. The data were collected from 151 female students in classes of nutrition or psychology in Kyungnam University. Measurements of height, weight and triceps skinfold thickness (TSf) were made by well-trained interviewers, and BMI was calculated. Daily nutrient intakes were obtained from the self-reported three-day dietary records for the kinds and the amounts of foods consumed by the student subjects. The students were also asked to complete three questionnaires : Mehrabian's eating-related characteristics questionnaire, Eysenck Personality Questionnaire, and the Berk Depression Inventory. The results of the study were as follows : 1) Reliability of factored homogeneous item dimensions (FHIDS) of the translated version of the eating-related characteristics questionnaire showed a similar profile compared with the original. Moreover, the loading values of Cronbach-$\alpha$ for some FHIDs, which were excluded in order to constitute primary-level factors (for example, 'predisposition to obesity' etc) with a high reliability, were much lower than Mehrabian's. Therefore the eating-related characteristics questionnaire could be effectively used for Korean students for predicting predisposition to obesity and eating disorders. 2) With regard to the relationship between anthropometric indices and eating-related characteristics, BMI measurements showed a high and a positive correlation with 'predisposition to obesity' and 'uncontrollable urges to eat', and a negative correlation with a 'predisposition to anorexia'. The heavier body weight and the more fat mass that the subjects had, the higher the probability that the subjects were overeating. 3) The intakes of some minerals (Fe, K, Na) and Vitamin C showed significantly negative correlations with a 'predisposition to obesity' and a 'predisposition to anorexia'. But the intakes of vitamin B$_2$, niacin, and retinol were positively correlated with'uncontrollable urges to eat'. 4) Among personality dimensions, neuroticism had a positive correlation with a 'predisposition to obesity', 'uncontrollable urges to eat', and 'predisposition to anorexia'. 5) Neuroticism was negatively correlated with intakes of calories, carbohydrates, K, Fe, Vitamin C, etc. On the contrary, all personality dimensions were positively correlated with intakes of retinol. In conclusion, the translated version of Mehrabian's eating-related characteristics questionnaire appears to be effective for nutritional or psychological assessments of any predisposition to eating disorders among Korean college students.

Effects of Regular Walking Exercise on Health-Related Parameters in Persons with Chronic Diseases (규칙적인 걷기운동이 질환별 노인의 건강변인에 미치는 효과)

  • Lim, Hwe-Jin;Kim, Yu-Sik;Cho, Hyeong-Suk;Kim, Chang-Hee;Lim, Hee-Jung;Jeong, Hee-Seong;Im, Jee-Aee;Yoon, Byung-Kon;Paik, Il-Young;Suh, Sang-Hoon
    • Journal of Life Science
    • /
    • v.19 no.12
    • /
    • pp.1750-1757
    • /
    • 2009
  • The purpose of this study was to investigate the effects of regular walking exercise on health-related parameters in the elderly with chronic diseases - apoplexy, overweight, impaired fasting glucose, and overweight + impaired fasting glucose. A total of 85 subjects, 27, 17, 21 and 20 in apoplexy (A), overweight (O), impaired fasting glucose (IFG), overweight + impaired fasting glucose group (O_IFG), respectively, completed a 12-week walking exercise. The health-related parameters were measured before and at the completion of the exercise program including anthropometric measurements, functional physical fitness levels, blood pressure, fasting glucose, blood lipid profiles and chronic inflammatory markers (CRPs). Significant improvements in body weight, BMI, %body fat, blood pressure, all blood lipid measurements and all measured physical fitness items were shown in A; those in %body fat, TC, HDL-C and LDL-C in O; those in body weight, BMI, %body fat, fasting glucose, TC, TG and HDL-C in IFG; and those in body weight, HDL-C and LDL-C in O_IFG (p<0.05). The results of the present study demonstrated that a 12-week walking exercise brought positive effects on body weight, bloody lipid profiles, fasting glucose and functional physical fitness levels in the elderly with chronic diseases. In conclusion, this study suggested that walking regularly is very effective in lowering the risks of developing chronic diseases.

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

Accuracy Analysis of ADCP Stationary Discharge Measurement for Unmeasured Regions (ADCP 정지법 측정 시 미계측 영역의 유량 산정 정확도 분석)

  • Kim, Jongmin;Kim, Seojun;Son, Geunsoo;Kim, Dongsu
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.553-566
    • /
    • 2015
  • Acoustic Doppler Current Profilers(ADCPs) have capability to concurrently capitalize three-dimensional velocity vector and bathymetry with highly efficient and rapid manner, and thereby enabling ADCPs to document the hydrodynamic and morphologic data in very high spatial and temporal resolution better than other contemporary instruments. However, ADCPs are also limited in terms of the inevitable unmeasured regions near bottom, surface, and edges of a given cross-section. The velocity in those unmeasured regions are usually extrapolated or assumed for calculating flow discharge, which definitely affects the accuracy in the discharge assessment. This study aimed at scrutinizing a conventional extrapolation method(i.e., the 1/6 power law) for estimating the unmeasured regions to figure out the accuracy in ADCP discharge measurements. For the comparative analysis, we collected spatially dense velocity data using ADV as well as stationary ADCP in a real-scale straight river channel, and applied the 1/6 power law for testing its applicability in conjunction with the logarithmic law which is another representative velocity law. As results, the logarithmic law fitted better with actual velocity measurement than the 1/6 power law. In particular, the 1/6 power law showed a tendency to underestimate the velocity in the near surface region and overestimate in the near bottom region. This finding indicated that the 1/6 power law could be unsatisfactory to follow actual flow regime, thus that resulted discharge estimates in both unmeasured top and bottom region can give rise to discharge bias. Therefore, the logarithmic law should be considered as an alternative especially for the stationary ADCP discharge measurement. In addition, it was found that ADCP should be operated in at least more than 0.6 m of water depth in the left and right edges for better estimate edge discharges. In the future, similar comparative analysis might be required for the moving boat ADCP discharge measurement method, which has been more widely used in the field.

Decrease of the Activation and Carbamylation of Rubisco by High CO2 in Kidney Bean (KidneyBean에서의 고 CO2 농도에 의한 Rubisco의 Activation과 Carbamylation의 감소)

  • 노광수;김재기
    • KSBB Journal
    • /
    • v.11 no.3
    • /
    • pp.295-302
    • /
    • 1996
  • The measurements of rubisco parameters are important in photosynthetic studies. In this experiment, we used photometric assay method to detect these major parameters, such as activity, carbamylation and amount of rubisco. The main advantages of this method are very simple and as sensitive as conventional methods which usually produce radioactive waste. In this study, with kidney bean (Phaseolus vulgatis L.) leaves grown at normal $CO_2$ (350ppm) and high $CO_2$ (650 ppm), we investigated the effect of $CO_2$ concentration on activation and carbamylation of rubisco by measuring the rubisco activity, carbamylation rate and amount of rubisco using a dual beam (334nm and 405nm) spectrophotometer, and analyzed the polypeptide profiles of rubisco by SDS-PAGE. When $CO_2$ concentration was raised from 350ppm to 650ppm, all parameters of rubisco were decreased : $41.2{\mu}M/m^2/s and 52.2{\mu}M/m^2/s$ to $27.4{\mu}M/m^2/s and 46.1{\mu}M/m^2/s$ for initial and total rubisco activity, respectively ; from 79% to 58.9% for carbamylation rate ; from $1.94 {\mu}M/m^2$ to 1.58{\mu}M/m^2$ for amount of rubisco. These results suggests that the decrease in rubisco activity at high $CO_2$ was caused by carbamylation. The analysis of the preparation by SDS-PAGE showed two major polypeptides at 50 and 14.5 kD which were identified as the large and the small subunits of rubisco. There were no differences in the intensity compared high $CO_2$ to normal $CO_2$ in both 50 kD and 14.5 kD bands. We also found that these inhibitory effects of $CO_2$ were reversible. When high $CO_2$ was switched to normal $CO_2$, the parameters of rubisco changed were almost the same as normal rubisco parameters. These data provide an evidence that activity of rubisco was recovered by $CO_2$ concentration of 350 ppm.

  • PDF