• 제목/요약/키워드: Profile fitting

검색결과 113건 처리시간 0.027초

Gas dynamics and star formation in dwarf galaxies: the case of DDO 210

  • Oh, Se-Heon;Zheng, Yun;Wang, Jing
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.75.4-75.4
    • /
    • 2019
  • We present a quantitative analysis of the relationship between the gas dynamics and star formation history of DDO 210 which is an irregular dwarf galaxy in the local Universe. We perform profile analysis of an high-resolution neutral hydrogen (HI) data cube of the galaxy taken with the large Very Large Array (VLA) survey, LITTLE THINGS using newly developed algorithm based on a Bayesian Markov Chain Monte Carlo (MCMC) technique. The complex HI structure and kinematics of the galaxy are decomposed into multiple kinematic components in a quantitative way like 1) bulk motions which are most likely to follow the underlying circular rotation of the disk, 2) non-circular motions deviating from the bulk motions, and 3) kinematically cold and warm components with narrower and wider velocity dispersion. The decomposed kinematic components are then spatially correlated with the distribution of stellar populations obtained from the color-magnitude diagram (CMD) fitting method. The cold and warm gas components show negative and positive correlations between their velocity dispersions and the surface star formation rates of the populations with ages of < 40 Myr and 100~400 Myr, respectively. The cold gas is most likely to be associated with the young stellar populations. Then the stellar feedback of the young populations could influence the warm gas. The age difference between the populations which show the correlations indicates the time delay of the stellar feedback.

  • PDF

Inference of Chromospheric Plasma Parameters on the Sun from Strong Absorption Lines

  • Chae, Jongchul;Madjarska, Maria S.;Kwak, Hannah;Cho, Kyuhyoun
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.44.4-45
    • /
    • 2020
  • The solar chromosphere can be observed well through strong absorption lines. We infer the physical parameters of chromospheric plasmas from these lines using a multilayer spectral inversion. This is a new technique of spectral inversion. We assume that the atmosphere consists of a finite number of layers. In each layer the absorption profile is constant and the source function is allowed to vary with optical depth. Specifically, we consider a three-layer model of radiative transfer where the lowest layer is identified with the photosphere and the two upper layers are identified with the chromosphere. This three-layer model is fully specified by 13 parameters. Four parameters can be fixed to prescribed values, and one parameter can be determined from the analysis of a satellite photospheric line. The remaining eight parameters are determined from a constrained least-squares fitting. We applied the multilayer spectral inversion to the spectral data of the Hα and the Ca II 854.21 nm lines taken in a quiet region by the Fast Imaging Solar Spectrograph (FISS) of the Goode Solar Telescope (GST). We find that our model successfully fits most of the observed profiles and produces regular maps of the model parameters. We conclude that our multilayer inversion is useful to infer chromospheric plasma parameters on the Sun.

  • PDF

java Based Magnetic Resonance User Interface의 Advanced Method for Accurate, Robust, and Efficient Spectral Fitting 분석방법의 관찰자 변동 요소 (Observer Variation Factor on Advanced Method for Accurate, Robust, and Efficient Spectral Fitting of java Based Magnetic Resonance User Interface for MRS data analysis)

  • 이석준;유승만
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.143-148
    • /
    • 2016
  • 본 연구에서는 MRS 정량적 분석 중 jMRUI AMARES방법의 관찰자의 의존적 원인 요소를 숙련자와 비숙련자의 측정을 통하여 파악하고 하였다. 실험용 10주령 수컷 쥐의 간 부분을 3T MRI 장치를 활용하여 point resolved spectroscopy 펄스시퀀스를 이용하여 자기공명분광 데이터를 획득하였다. 획득된 데이터는 기준 값으로 사용하기 위해서 LCModel software 이용하여 1.3 ppm의 메틸렌 양성자와 4.7 ppm의 물 분자 양성자의 정량 비를 계산하였다. 7명의 비숙련 관찰자는 jMRUI AMARES 방법으로 총 지질을 1, 2주 간격으로 측정한 후 측정된 값을 SPSS를 이용하여 interclass correlation coefficient를 시행하였다. 관찰자 사이 간 측정치의 일관성의 신뢰도 분석을 표현한 크논바 알파 계수는 0.1 미만으로 나타났다. 1주차 데이터 값과 2주차 데이터 값의 평균값은 $0.096{\pm}0.038$로 LCModel의 분석 값보다 0.048로 50% 높게 관찰되었다. jMRUI AMARES분석 방법이 LCModel과 동일한 결과를 얻기 위해서는 정확한 대사물질의 개요를 숙지하고 획득된 그래프의 형태를 잘 파악하여 잔존 대사물질를 최소화 하여야 한다.

경구투여에 의한 양식산 넙치내 Erythromycin의 약물동태학적 특성 분석 (The Pharmacokinetics of Erythromycin in Cultured Paralichthys olivaceus after Oral administration)

  • 서정수;전은지;정승희;박명애;김나영
    • 수산해양교육연구
    • /
    • 제26권2호
    • /
    • pp.316-321
    • /
    • 2014
  • The pharmacokinetics of erythromycin (EM) after oral administration was studied in the cultured olive flounder, Paralichthys olivaceus, using LC/MS/MS. After single- or multiple-dose administration of EM (50, 100, 200 mg/kg body weight and 50 mg/kg for 5 days) by oral route in olive flounder ($350{\pm}40g$, $22{\pm}0.5^{\circ}C$), the concentration in the serum was determined at 1, 3, 6, 9, 24, 72, 120, 168, 264, 360, 504 and 720 h post-dose. The kinetic profile of absorption, distribution and elimination of EM in serum were analyzed fitting to a two-compartment model by WinNonlin program. The area under the concentration-time curve (AUC), maximum concentration ($C_{max}$), time for maximum concentration ($T_{max}$) following oral administration of 50, 100 and 200 mg/kg b.w. and 50 mg for 5 days. EM was $165.3hr^*{\mu}g/m{\ell}$ ($C_{max}$, $34.63{\mu}g/m{\ell}$; $T_{max}$, 1.56 hr), $212.8hr^*{\mu}g/m{\ell}$ ($C_{max}$, $60.38{\mu}g/m{\ell}$; $T_{max}$, 3.99 hr), and $592.37hr^*{\mu}g/m{\ell}$ ($C_{max}$, $63.01{\mu}g/m{\ell}$; $T_{max}$, 4 hr), respectively. The results of this study related to dosage and ${\mu}{\cdot}$withdrawal times could be used for prescription of EM in field for the treatment of bacterial diseases in olive flounder.

Far-ultraviolet Observations of the Comet C/2001 Q4 (NEAT)

  • Lim, Yeo-Myeong;Min, Kyoung-Wook;Seon, K.I.;Han, W.;Edelstein, J.
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2011년도 한국우주과학회보 제20권1호
    • /
    • pp.20.1-20.1
    • /
    • 2011
  • We present the results of far-ultraviolet (FUV) observations of comet C/2001 Q4 (NEAT) obtained with Far-ultraviolet Imaging Spectrograph (FIMS) on board the Korean microsatellite STSAT-1, which operated at an altitude of 700 km in a sun-synchronous orbit. FIMS is a dual-channel imaging spectrograph (S channel 900-1150 ${\AA}$, L channel 1350-1750 ${\AA}$, ${\lambda}/{\Box}{\lambda}$ ~ 550) with large image fields of view (S: $4^{\circ}.0{\times}4'.6$, L: $7^{\circ}.5{\times}4'.3$, angular resolution 5'-10') optimized for the observation of diffuse emission of astrophysical radiation. Comet C/2001 Q4 (NEAT) was observed with a scanning survey mode when it was located around the perihelion between 8 and 15 May 2004. Several important emission lines were detected including S I (1425, 1474 ${\AA}$), C I (1561, 1657 ${\AA}$) and several emission lines of CO $A1{\cap}-X1{\sum}+$ system in the L channel. We estimated QCO = ($2.58\;{\pm}\;0.64)\;{\times}\;1028$ s-1 from the production rate of CO 1510 ${\AA}$. We obtained L-channel image which have map size of $5^{\circ}{\times}5^{\circ}$. The image was constructed for the wavelength band of L-channel (1350-1750 ${\AA}$).We also obtained radial profile of S I, C I, CO with line fitting from central coma.

  • PDF

개인 맞춤형 운전면허 학습시스템 설계 (VA Design of Personalized e-Learning System for the Driver's License Test in Korea)

  • 오용선
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1055-1060
    • /
    • 2009
  • 본 논문에서는 인터넷을 통한 운전면허 학과시험 학습시스템을 설계한다. 문항반응이론에 의거하여 학습자 능력모수를 정확히 측정하고, 측정된 학습자의 능력에 따라 최적의 평가문제와 학습콘텐츠를 동적으로 제공함으로써, 짧은 시간에 효과적으로 합격에 도달할 수 있도록 하는 개인 맞춤형 이러닝 시스템을 제안한다. 본 학습시스템은 콘텐츠 데이터베이스에 저장된 개념 단위 오브젝트 형태의 운전면허 학과시험용 학습콘텐츠들과 문제은행 데이터베이스에 저장된 운전면허 학과시험용 평가문제들을 연계하여, 학습자의 문항반응에 따라 최적의 문항과 콘텐츠를 제공할 수 있도록 설계된다. 각 문항들은 난이도, 변별도, 추측도의 문항모수를 보유한다. 또한 사용자 프로파일 데이터베이스에는 학습자들의 상태정보, 운전면허 학과시험용 평가문제들에 대한 피험자들의 문항반응을 유지 관리하고, 피험자들의 문항반응을 기초로 학습자 능력모수를 저장한다. 이들 데이터베이스는 인터페이스 에이전트, 콘텐츠 문항선택 & 피드백 에이전트 및 오프라인 추정기로 구성된 동작구조에 의하여 온라인 혹은 오프라인 형태의 동적 맞춤형 학습방식을 제공하여 최적의 학습과정을 제공한다.

  • PDF

주파수 위상 간섭계를 이용한 펨토초 레이저 펄스의 시간적 특성연구 (Temporal characterization of femtosecond laser pulses using spectral phase interferometry for direct electric-field reconstuction)

  • 강용훈;홍경한;남창희
    • 한국광학회지
    • /
    • 제12권3호
    • /
    • pp.219-224
    • /
    • 2001
  • 주파수 위상 간섭계를 이용한 전기장 재구성 방법(SPIDER)을 이용하여 Kerr 렌즈 모드록킹된 티타늄 사파이어 레이저 공진기에서 생성된 펨토초 영역의 극초단 펄스의 펄스폭과 위상을 측정하였다. 8cm 길이의 SF10 매질과 마이켈슨형의 시간지연암(arm)을사용하여 주파수 층밀림(shearing)을 구현하고 제2종 BBO결정으로 합주파수 발생을 시켜 SPIDER 장치를 구성 하였다 얻어진 층밀림 주파수 간섭 신호로부터 SPIDER 알고리즘을 이용하여 펄스의 전기장을 복원하였다 SPIDER의 정확도를 확인하기 위해 SPIDER에서 얻은 펄스로 재구성한 간섭형 자체상솬신호를 직접 측정한 간섭형 자체상관 신호와 비교하였다. SPIDER를 티타늄 사파이어 레이저 공진기에 적용하여 19fs의 펄스폭을 얻었으며 sech$^2$나 가우시안으로 가정한 간섭형 자체상관의 결과는 이보다 작은 값으로 나타나서 펨토초 레이저의 정확한 펄스폭 측정을 위해서는 펄스모양의 가정이 필요없는 SPIDER 방법이 필요함을 알 수 있었다.

  • PDF

Florfenicol의 어류 병원성 세균에 대한 항균 효과와 경구 투여후 넙치 혈액에서의 약물동태학적 특성 (Antimicrobial Activity of Florfenicol Against Fish Pathogenic Bacteria and Pharmacokinetics in Blood of Cultured Olive Flounder by Oral Administration)

  • 정승희;서정수
    • 수산해양교육연구
    • /
    • 제25권5호
    • /
    • pp.1079-1087
    • /
    • 2013
  • Florfenicol(FF)을 넙치(평균체중 $700{\pm}50$ g, $23{\pm}1.5^{\circ}C$)에 1일 1회 경구(20 mg/kg BW) 투여한 다음, 경시적(1시간~168시간)으로 혈청 내 FF의 잔류량을 HPLC로써 분석하였다. FF의 경구 투여에 따른 넙치 체내 약물 혈중농도 측정결과를 바탕으로 two-compartment model로 WinNonlin program을 이용하여 FF의 흡수, 배설, 반감기 등 약물동태학적 매개변수(parameter)를 조사하였다. 혈청중 농도-시간곡선하 면적(AUC)은 22.51 ${\mu}g{\cdot}h/mL$, 혈중최고농도($C_{max}$)는 0.84 ${\mu}L/mL$, 혈중최고농도에 도달하는 시간($T_{max}$)은 8.62 시간, 약물이 혈중에서 완전히 0이 되는 시점인 예상소실시간(Et)은 447 계산되었다. 본 연구에서 얻어진 결과는 넙치에 FF를 처방하여 치료 계획을 수립할 때 유용하게 활용될 것으로 여겨진다.

Different Types of Active Region EUV Bright Points by Hinode/EIS

  • 이경선;문용재;김수진
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.28.2-28.2
    • /
    • 2010
  • We have investigated seven Extreme-Ultraviolet (EUV) bright points in the active region (AR 10926) on 2006 December 2 by the EUV imaging spectrometer (EIS) onboard Hinode spacecraft. We determined their Doppler velocities and non-thermal velocities from 15 EUV spectral lines (log T=4.7-7.2) by fitting each line profile to a Gaussian function. We present the Doppler velocity map as a function of temperature which corresponds to a different height. As a result, these active region bright points show two different types of characteristics. Type 1 bright point shows a systematic increase of Doppler velocity from -68 km/s (blue shift) at log T=4.7 to 27 km/s (red shift) at log T=6.7, while type 2 bright points have Doppler velocities in the range of -20 km/s and 20 km/s. Using MDI magnetograms, we found that only type 1 bright point was associated with the canceling magnetic feature at the rate of $2.4{\times}10^{18}$ Mx/hour. When assuming that these bright points are caused by magnetic reconnection and the Doppler shift indicates reconnection out flow, the pattern of the Doppler shift implies that type 1 bright point should be related to low atmosphere magnetic reconnection. We also determined electron densities from line ratio as well as temperatures from emission measure loci using CHIANTI atomic database. The electron densities of all bright points are comparable to typical values of active regions (log Ne=9.9-10.4). For the temperature analysis, the emission loci plots indicate that these bright points should not be isothermal though background is isothermal. The DEM analysis also show that while the background has a single peak distribution (isothermal), the EUV bright points, double peak distributions.

  • PDF

Air puff에 의한 각막 변형의 주파수 영역 분석 (A Frequency Domain Analysis of Corneal Deformation by Air Puff)

  • 황호식;이병하;이창수
    • 전기전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.240-247
    • /
    • 2014
  • 안압의 측정은 각막에 air puff 후 각막의 변형 즉, 각막의 두께나 변위 등 생역학적 성질을 관찰함으로써 이루어진다. 본 논문에서는 녹내장이나 라식의 진단을 위하여 사용되는 안압계의 air puff에 의한 각막의 변형을 주파수 영역에서 분석하였다. Air puff 후 각막의 중심부 주변의 변위에 대한 진동 주파수를 측정함으로써 환자와 정상인을 구별한다. 동영상으로부터 이진 영상을 구하고, 상하 변위 데이터와 곡선 정합의 차를 구하여 시간에 따른 각막 상하 진동 프로파일 데이터를 추출하였다. Fourier 변환으로 비정상인의 진동 주파수는 479.2Hz를 얻었고 정상인의 경우 단단함으로 인하여 702.8Hz의 고주파 성분을 볼 수 있었다. 또한 Hilbert-Huang 변환의 EMD 방법을 이용, 고유 모드 함수로 분해하여 국소적, 비선형, 비정상성을 가지는 데이터를 얻고 주파수와 전력을 분석하였다. 마지막으로 특정 고유 모드 함수에 대한 환자와 정상인의 전력비가 6배 이상 차이가 나는 것을 확인하였다.