• Title/Summary/Keyword: Profile angle

Search Result 614, Processing Time 0.034 seconds

Measurement of Velocity Profile in Liquid Metal Flow Using Electromagnetic Tomography (전자기 토모그래피를 이용한 액체 금속 속도장 측정)

  • Choi, Sang-Ho;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1749-1754
    • /
    • 2004
  • In order to measure non-intrusively velocity profile in liquid metal flow, a modified electromagnetic flowmeter was designed, which was based on electromagnetic tomography technique. Under the assumption that flow is fully-developed, axisymmetric and rectilinear, the velocity profile was reconstructed after the flowmeter equation, the first kind of Fredholm integration equation, was linearized. In reconstruction process Tikhonov regularization method with regularization parameter was used. The reconstructed velocity profile had the nearly same as turbulent flow profile which was approximately represented as log law. In addition, flowmeter output for a fixed magnet rotation angle was linearly proportional to flow rate. When magnet rotation angle was $54^{\circ}$, axisymmetric weight function was nearly uniform so that the flowmeter gives a constant signal for any fully-developed, axisymmetric and rectilinear profile with a constant flow rate.

  • PDF

Numerical Study on the Effects of Velocity Profile Distortion and Swirl on Pressure Difference of Orifice Flowmeter Due to Pipe structure (배관구조에 따른 속도분포 변형과 선회가 오리피스 유량계의 압력차에 미치는 영향에 대한 수치적 연구)

  • Kim, Hong-Min;Kim, Kwang-Yong;Her, Jae-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1450-1456
    • /
    • 2003
  • Three-dimensional pipe flows with elbows, tees and headers in three different pipe systems are calculated to estimate the effect of asymmetry of axial velocity profile and swirl on measuring accuracy of an orifice flowmeter. It is evaluated how the pressure difference across the orifice is dependent on the upstream straight pipe length and how swirl intensity, swirl angle, and axial velocity distribution affect the measuring error of the orifice flowmeter. From the results, it is found that variation of the pressure difference across the orifice is negligible in case that maximum swirl angle is less than 2$^{\circ}$, and also that the pressure difference across the orifice is more sensitive to the asymmetry of axial velocity profile rather than the swirl intensity.

Predictors of favorable soft tissue profile outcomes following Class II Twin-block treatment

  • Kim, Ji-Eun;Mah, Su-Jung;Kim, Tae-Woo;Kim, Su-Jung;Park, Ki-Ho;Kang, Yoon-Goo
    • The korean journal of orthodontics
    • /
    • v.48 no.1
    • /
    • pp.11-22
    • /
    • 2018
  • Objective: The aim of this study was to determine cephalometric factors that help predict favorable soft-tissue profile outcomes following treatment with the Class II Twin-block appliance. Methods: Pre- and post-treatment lateral cephalograms of 45 patients treated with the Class II Twin-block appliance were retrospectively analyzed. Profile silhouettes were drawn from the cephalograms and evaluated by three orthodontists in order to determine the extent of improvement. Samples were divided into a favorable group (upper 30% of visual analogue scale [VAS] scores, n = 14) and an unfavorable group (lower 30% of VAS scores, n = 14). Skeletal and soft-tissue measurements were performed on the cephalograms and an intergroup comparison was conducted. Results: An independent t-test revealed that the following pre-treatment values were lower in the favorable group compared to the unfavorable group: lower incisor to mandibular plane angle, lower incisor to pogonion distance, point A-nasion-point B angle, sella-nasion line (SN) to maxillary plane angle, SN to mandibular plane angle, gonial angle, and symphysis inclination. The favorable group had a larger incisor inclination to occlusal plane. Moreover, the favorable group showed larger post-treatment changes in gonial angle, B point projection, and pogonion projection than did the unfavorable group. Conclusions: Class II malocclusion patients with a low divergent skeletal pattern and reduced lower incisor protrusions are likely to show more improvement in soft-tissue profile outcomes following Class II Twin-block treatment.

Follicular Unit Classification Method Using Angle Variation of Boundary Vector for Automatic Hair Implant System

  • Kim, Hwi Gang;Bae, Tae Wuk;Kim, Kyu Hyung;Lee, Hyung Soo;Lee, Soo In
    • ETRI Journal
    • /
    • v.38 no.1
    • /
    • pp.195-205
    • /
    • 2016
  • This paper presents a novel follicular unit (FU) classification method based on an angle variation of a boundary vector according to the number of hairs in several FU images. The recently developed robotic FU harvest system, ARTAS, classifies through digital imaging the FU type based on the number of hairs with defects in the contour and outline profile of the FU of interest. However, this method has a drawback in that the FU classification is inaccurate because it causes unintended defects in the outline profile of the FU. To overcome this drawback, the proposed method classifies the FU's type by the number of variation points that are calculated using an angle variation a boundary vector. The experimental results show that the proposed method is robust and accurate for various FU shapes, compared to the contour-outline profile FU classification method of the ARTAS system.

A ROENTGENOCEPHALOMETRIC STUDY OF THE BONY STRUCTURE AND ITS PROFILE (두부방사선규격사진법에 의한 측모의 경조직과 연조직에 관한 연구)

  • Kang, Hong Koo
    • The korean journal of orthodontics
    • /
    • v.6 no.1
    • /
    • pp.17-24
    • /
    • 1976
  • The primary objective of this study was to define the differences that exist. between different sexes on the dentoskeletal framework and the soft tissue profile around the mouth. For the purpose of this study, cephalometric radiographs were obtained from the centric occlusion with closed lip position, through the research on each 42 males and females aged from 17 to 22 years with normal occlusion and acceptable facial appearence. The results were as follows: 1. Maxillary to mandibular relationships. Among the angles formed by the long axis of the maxillary and mandibular anterior teeth, the maxillary and mandibular anterior alveolar bone, and the lower and upper lips (Fig.2), only the angle formed by the lips was more acute in males than in females. The males have a more rounded profile, and the females have a flatter profile in the lower third of the face. The differences is statistically significant for the angle formed by the lips. The fact that the lips have a difference greater than that of teeth or the alveolar bone indicates that the lip position is not entirely due to tooth and bony support. Possibly the thickness of the lips has an influence. 2. Occlusal plane. The occlusal plane was related to the anterior tooth inclination, anterior alveolar bone profile, and the lip contour, both maxillary and mandibular (Fig.3). Only the angle related to lower lip was statistically significant. The females again had the more obtuse angle, indicating a flatter profile than that of the males. 3.Skeletal planes. The angles formed by the anterior maxillary lips, teeth, and alveolar bone with the Frankfort plane and the angles of the mandibular lips, teeth, and, alveolar bone and the mandibular plane were investigated (Fig.4). Results were similar to those from maxillary to mandibular relationships. The results were statistically significant for the upper lip and the lower lip, only. 4. Esthetics. The facial line and the mandibular plane were compared with the esthetic line. These angles were different for the different sexes, but only the latter was statistically significant. This difference may be due to the profile contour of the nose.

  • PDF

Measurement of velocity Pronto in Liquid Metal Flow Using Electromagnetic Tomography (전자기 토모그래피를 이용한 액체 금속 속도장 측정)

  • Ahn Yeh-Chan;Kim Moo Hwan;Choi Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1271-1278
    • /
    • 2004
  • In order to measure non-intrusively velocity profile in liquid metal flow, a modified electromagnetic flowmeter was designed, which was based on electromagnetic tomography technique. Under the assumption that flow is fully-developed, axisymmetric and rectilinear, the velocity profile was reconstructed after the flowmeter equation, the first kind of Fredholm integration equation, was linearized. In reconstruction process Tikhonov regularization method with regularization parameter was used. The reconstructed velocity profile had the nearly same as turbulent flow profile which was approximately represented as log law. In addition, flowmeter output fur a fixed magnet rotation angle was linearly proportional to flow rate. When magnet rotation angle was 54$^{\circ}$, axisymmetric weight function was nearly uniform so that the flowmeter gives a constant signal for any fully-developed, axisymmetric and rectilinear profile with a constant flow rate.

Design Method of Test Road Profile for Vehicle Accelerated Durability Test (차량의 가속내구시험을 위한 TEST ROAD PROFILE 설계방법)

  • Min, B.H.;Jung, W.W.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.1
    • /
    • pp.128-141
    • /
    • 1994
  • This roport explain the basic theory of desinging the accelerating durability test road and the role of each factors contributing to test road surface profile. Also this road is designed by considering the charactors of vehicle suspension system and condition of driving. In test road, the factors affecting to the vehicle Structural durability are correlation among surface shape of road profile, frequency of vehicle suspension system, distribution of axletwist angle and vibration profile height Road PSD magnitude and frequency delay is used to control these factors relation.

  • PDF

The Results of the First Ray Forefoot Osteotomy Using Low Profile Wedge Plate without a Bone Grafting for Pes Planus Correction (제 1열 전족부 절골술을 통한 평발 교정에 있어 골이식 없이 사용한 소형 쐐기형 금속판의 치료 결과)

  • Choi, Jun Young;Shin, Myung Jin;Suh, Jin Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.1
    • /
    • pp.7-11
    • /
    • 2017
  • Purpose: We retrospectively analyzed the radiographic and clinical results after the first ray of forefoot osteotomy using low profile wedge plate without additional cancellous bone grafting for pes planus correction. Materials and Methods: Twenty-four patients were enrolled in this study. Medial cuneiform opening wedge osteotomy was performed in 12 patients (Cotton osteotomy, group C) and first metatarsal base osteotomy was performed in 12 patients (group MT). Results: On average, the wedge size was 5.61 mm (5~6 mm). The mean time to radiographic union was 3.18 and 3.27 months in groups C and MT, respectively. Postoperative talonavicular coverage angle, talo-first metatarsal angle (anteroposterior), talo-first metatarsal angle (lateral), talo-calcaneal angle (lateral), medial cuneiform height, and American orthopaedic foot, as well as ankle society midfoot scale were significantly improved in both groups. Nonunion, delayed union or fixation failure was not presented in our series. Conclusion: We have shown that low profile wedge plate was effective in the case of first ray forefoot osteotomy for pes planus correction without any additional cancellous bone grafting.

A study on design of spherical hob for internal gear hobbing (내접치차 가공용 구형 호브의 설계에 관한 연구)

  • 박천경;박동삼
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.6
    • /
    • pp.1312-1319
    • /
    • 1988
  • Internal gear is the important part of the planetary reduction gear system. This study aims at developing the numerical analysis method for design of spherical hob to manufacture internal gear. Methods of calculation of hob tooth profile, generating tooth profile and tooth profile errors such as the errors of pressure angle, tooth thickness and pitch of spherical hob must be made smaller than those of standard tooth profile. And, the smaller the pressure angle and the number of equivalent pinion tooth become, the larger the tooth profile errors are. One design example of spherical hob is proposed.

Angle-sensitive Pixels Based on Subwavelength Compound Gratings

  • Meng, Yunlong;Hu, Xuemei;Yang, Cheng;Shen, Xinyu;Cao, Xueyun;Lin, Lankun;Yan, Feng;Yue, Tao
    • Current Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.359-366
    • /
    • 2022
  • In this paper, we present a new design for angle-sensitive pixels (ASPs). The proposed ASPs take advantage of subwavelength compound gratings to capture the light angle, which enables pixel size to reach the wavelength scale of 0.7 ㎛ × 0.7 ㎛. The subwavelength compound gratings are implemented by the wires of the readout circuit inherent to the standard complementary metal-oxide-semiconductor manufacturing process, thus avoiding additional off-chip optics or post-processing. This technique allows the use of two pixels for horizontal or vertical angle detection, and can determine the light's angle in the range from -45° to +45°. The proposed sensor enables surface-profile reconstruction of microscale samples using a lensless imaging system.